Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Rotating Unbalanced-Mass devices for scanning: Results from the proof-of-concept test

Rotating unbalanced-mass (RUM) devices are a new way to scan space-based, balloon-borne, and ground-based gimbaled payloads, like x-ray and gamma-ray telescopes. They can also be used to scan free-flying spacecraft. Circular scans, linear scans, and raster scans can be generated. A pair of RUM devices generates the basic scan motion and an auxiliary control system using torque motors, control moment gyros, or reaction wheels keeps the scan centered on the target and produces some complementary motion for raster scanning. Previous analyses and simulation results show that this approach offers significant power savings compared to scanning only with the auxiliary control system, especially with large payloads and high scan frequencies. However, these claims have never been proven until now. This paper describes a laboratory experiment which tests the concept of scanning a gimbaled payload with RUM devices. The test results are compared with those from a computer simulation model of the experiment and the differences are discussed.

Alhorn, Dean C.↗

The Effect Stacking Fault Segregation and Phase Transformations have on Creep Strength in Ni-based Superalloys

In this study, two commercially similar polycrystalline Ni-based disk superalloys (LSHR and ME3) were creep tested at 760C and 552MPa to approximately 0.3% plastic strain. LSHR consistently displayed superior creep properties at this stress/temperature regime even though the microstructural characteristics between the two alloys were comparable. High resolution structural and chemical analysis, however, revealed significant differences between the two alloys among active gamma prime shearing modes involving superlattice intrinsic and extrinsic stacking faults. In ME3, Co and Cr segregation and Ni and Al depletion were observed along the intrinsic faults - revealing a gamma prime -to- gamma phase transformation. Conversely in LSHR, an alloy with a higher W content, Co and W segregation was observed along the intrinsic faults. This observation combined with scanning transmission electron microscopy (STEM) simulations confirm a gamma prime-to-D019 phase transformation along the intrinsic faults in LSHR. Using experimental observations and density functional theory calculations, a novel local phase transformation strengthening mechanism is proposed that could be further utilized to improve the high temperature creep capabilities of Ni-base disk alloys.

Superalloy↗

Measurements of selected psi /3684/ branching ratios from a study of secondary lepton pairs

The measurements considered were made at the electron-positron storage ring at the Stanford Linear Accelerator Center. The apparatus used consists of two identical spectrometers mounted in a collinear configuration about the beam-interaction region. The energies of secondary electrons or positrons are measured with good resolution in large NaI(Tl) total-absorption detectors. Data accumulated without gamma-ray converters were examined for electron-positron pairs. The data taken with gamma-ray converters in place and at center-of-mass energies within 1 MeV of the resonance energy were scanned for evidence of either charged particles or converted gamma rays accompanying the detected muon pairs.

Hilger, E.↗

MO-F-CAMPUS-I-05: Radiation Dosimetry of 99mTc-IDA-D-[c(RGDfK)]2, a SPECT Agent for Angiogenesis Imaging

Purpose: Tc-99m labeled IDA-D-[c(RGDfK){sub 2} ( {sup 99m}Tc-RGD) is a recently developed radiotracer for gamma camera or single photon emission computed tomography (SPECT) imaging and promising agent for the visualization of angiogenesis. In this study, we investigated the internal radiation dosimetry of {sup 99m}Tc-RGD in humans. Methods: Six normal controls (F:M=4:2; 68.3±3.2 years; 56.5±10.7 kg) were participated in this study. Simultaneous anterior and posterior scans of whole-body were performed using dual head gamma camera system. Before the emission scan, transmission scan was performed just before injection of {sup 99m}Tc-RGD using Co-57 flood source. After an intravenous injection of 388.7±29.3 MBq of {sup 99m}Tc-RGD, six serial emission scans were performed at 0, 1, 2, 4, 8 and 24 hours post-injection. The anterior and posterior images were geometrically averaged and attenuation correction was applied using transmission scan image. Regions of interest (ROIs) were drawn on liver, gallbladder, kidneys, urinary bladder, spleen, brain, and large intestine. Time activity curves were obtained from serial emission scan and ROIs. The number of disintegrations per unit activity administered (residence time) were calculated from the area under the curve of time activity curves and injected dose of each patient. Finally, the radiation dose for each organ and effective doses were obtained using OLINDA/EXM 1.1 software and residence time. Results: High radiation doses were reported on renal and biliary excretion tracks such as urinary bladder wall, upper large intestine, kidneys, liver and gallbladder wall and their doses were 19.15±6.84, 19.28±4.78, 15.67±0.90, 9.13±1.71 and 9.09±2.03 µGy/MBq, respectively. The effective dose and effective dose equivalent were 5.08±0.53 and 7.11±0.58 µSv/MBq, respectively. Conclusion: We evaluated the radiation dose of 99mTc-RGD, which has an acceptable effective radiation dose compare to the other Tc-99m labeled radio-tracers.

60 APPLIED LIFE SCIENCES↗

Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding {sup 99m}Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for use in PET.

60 APPLIED LIFE SCIENCES↗

Spatial Distribution of -Crystals in Metallocene-Made Isotactic Polypropylene Crystallized under Combined Thermal and Flow Fields

The present Article reports the relationships between molecular orientation, formation, and spatial distribution of {gamma}-crystals in metallocene-made isotactic polypropylene (m-iPP) samples prepared by two industrial processes: conventional injection molding (CIM) and oscillatory shear injection molding (OSIM), in which combined thermal and flow fields typically exist. In particular, spatial distributions of crystallinity, fraction of {gamma}-crystal (f{gamma}) with respect to {alpha}-crystal, and lamella-branched shish-kebab structure in the shaped samples were characterized by synchrotron two-dimensional (2D) wide-angle X-ray diffraction (WAXD) and small-angle X-ray scattering (SAXS) techniques. The results showed that the crystallinity in any given region of OSIM samples was always higher than that of CIM samples. The value of f{gamma} increased monotonously from skin to core in CIM samples, whereas the corresponding f{gamma} increased nonmonotonically in OSIM samples. The spatial distribution of {gamma}-crystal in OSIM samples can be explained by the epitaxial arrangement between {gamma}- and {alpha}-crystal in a lamella-branched shish-kebab structure. In the proposed model, the parent lamellae of {alpha}-crystal provide secondary nucleation sites for daughter lamellae of {alpha}-crystal and {gamma}-crystal, and the different content of parent lamellae results in varying amounts of {gamma}-crystal. In OSIM samples, the smallest parent-daughter ratio ([R] = 1.38) in the core region led to the lowest fraction of {gamma}-crystal (0.57), but relatively higher {gamma}-crystal content (0.69) at 600 and 1200 {micro}m depth of the samples (corresponding to [R] of 4.5 and 5.8, respectively). This is consistent with the proposed model where more parent lamellae provide more nucleation sites for crystallization, thus resulting in higher content of {gamma}-crystal. The melting behavior of CIM and OSIM samples was studied by differential scanning calorimetery (DSC). The observed double-melting peaks could be explained by the melting of {gamma}- and {alpha}-crystal of the shaped samples. The f{gamma} distribution calculated from the relative areas of the peaks in the DSC scans was also consistent with the WAXD results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Verification of Gamma Knife extend system based fractionated treatment planning using EBT2 film

Purpose: This paper presents EBT2 film verification of fractionated treatment planning with the Gamma Knife (GK) extend system, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery.Methods: A human head shaped phantom simulated the verification process for fractionated Gamma Knife treatment. Phantom preparation for Extend Frame based treatment planning involved creating a dental impression, fitting the phantom to the frame system, and acquiring a stereotactic computed tomography (CT) scan. A CT scan (Siemens, Emotion 6) of the phantom was obtained with following parameters: Tube voltage—110 kV, tube current—280 mA, pixel size—0.5 × 0.5 and 1 mm slice thickness. A treatment plan with two 8 mm collimator shots and three sectors blocking in each shot was made. Dose prescription of 4 Gy at 100% was delivered for the first fraction out of the two fractions planned. Gafchromic EBT2 film (ISP Wayne, NJ) was used as 2D verification dosimeter in this process. Films were cut and placed inside the film insert of the phantom for treatment dose delivery. Meanwhile a set of films from the same batch were exposed from 0 to 12 Gy doses for calibration purposes. An EPSON (Expression 10000 XL) scanner was used for scanning the exposed films in transparency mode. Scanned films were analyzed with inhouse written MATLAB codes.Results: Gamma index analysis of film measurement in comparison with TPS calculated dose resulted in high pass rates >90% for tolerance criteria of 1%/1 mm. The isodose overlay and linear dose profiles of film measured and computed dose distribution on sagittal and coronal plane were in close agreement.Conclusions: Through this study, the authors propose treatment verification QA method for Extend frame based fractionated Gamma Knife radiosurgery using EBT2 film.

61 RADIATION PROTECTION AND DOSIMETRY↗

3D Gamma Source Mapping and Intervention Analysis - 19243

3D gamma source mapping and intervention analysis, through Transco Products, Inc.'s RadVision3D{sup R}, uses the N-Visage Scanner{sup TM} by Createc combining laser scanning, optical imaging, and CZT (Cadmium Zinc Telluride) technologies to capture plant geometry, images, and gamma radiation data. By capturing multiple scans in an area of interest a full 3D analysis can be performed using N-Visage Fusion{sup TM} software by Createc which develops a 3D model showing radioactive sources in the environment and allowing various interventions, such as shielding or source removal, to be modeled virtually. The output of a RadVision3D{sup R} project is a scaled virtual environment that the user can 'walk through' on a PC for training and work planning activities. Included in the viewer are dose planes for the as-scanned conditions as well as for each intervention, showing the dose rate at any point in the room. A virtual dosimeter is built into the viewer to allow users to be fully immersed in the environment in which they will be working, without being exposed to actual radiation or other hazardous conditions. This technology can help save dose at operating nuclear power plants when used for planning large work scopes in high radiation areas and is valuable as a characterization tool for decommissioning facilities. Adopters of 3D gamma source mapping and intervention analysis save time, money, and dose by evaluating options well in advance of the performance of any work, and optimizing interventions using accurate modelling techniques to plan work evolutions. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Gamma Spectrometry Examination of the AGR-3/4 Irradiation

The initial results from gamma spectrometry examination of the different components from the combined third and fourth US Advanced Gas Reactor Fuel Development TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail particles surrounded by two graphitic diffusion rings (inner and outer) and a graphite sink were irradiated in the Idaho National Laboratory’s Advanced Test Reactor. Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. Additionally, inner and outer rings were also examined by gamma spectrometry both to evaluate the fission product inventory and the distribution of gamma-emitting fission products within the rings using gamma emission computed tomography. The cesium inventory of the scanned rings compares acceptably well with the expected inventory from fission product transport modeling. The inventory of the graphite fission product sinks is also being evaluated by gamma spectrometry.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Gamma Spectrometry Examination of the AGR-3/4 Irradiation - 18594

The initial results from gamma spectrometry examination of the different components from the combined third and fourth US Advanced Gas Reactor Fuel Development TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail particles surrounded by two graphitic diffusion rings (inner and outer) and a graphite sink were irradiated in the Idaho National Laboratory s Advanced Test Reactor. Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. Additionally, inner and outer rings were also examined by gamma spectrometry both to evaluate the fission product inventory and the distribution of gamma-emitting fission products within the rings using gamma emission computed tomography. The cesium inventory of the scanned rings compares acceptably well with the expected inventory from fission product transport modeling. The inventory of the graphite fission product sinks is also being evaluated by gamma spectrometry. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation-induced DNA damage and the relative biological effectiveness of 18 F-FDG in wild-type mice

Clinically, the most commonly used positron emission tomography (PET) radiotracer is the glucose analog 2-[ 18 F] fluoro-2-deoxy-d-glucose ( 18 F-FDG), however little research has been conducted on the biological effects of 18 F-FDG injections. The induction and repair of DNA damage and the relative biological effectiveness (RBE) of radiation from 18 F-FDG relative to 662 keV γ-rays were investigated. The study also assessed whether low-dose radiation exposure from 18 F-FDG was capable of inducing an adaptive response. DNA damage to the bone marrow erythroblast population was measured using micronucleus formation and lymphocyte γH2A.X levels. To test the RBE of 18 F-FDG, mice were injected with a range of activities of 18 F-FDG (0–14.80 MBq) or irradiated with Cs-137 γ-rays (0–100 mGy). The adaptive response was investigated 24 h after the 18 F-FDG injection by 1 Gy in vivo challenge doses for micronucleated reticulocyte (MN-RET) formation or 1, 2 and 4 Gy in vitro challenges doses for γH2A.X formation. A significant increase in MN-RET formation above controls occurred following injection activities of 3.70, 7.40 or 14.80 MBq (P < 0.001) which correspond to bone marrow doses of ~35, 75 and 150 mGy, respectively. Per unit dose, the Cs-137 radiation exposure induced significantly more damage than the 18 F-FDG injections (RBE = 0.79 ± 0.04). A 20% reduction in γH2A.X fluorescence was observed in mice injected with a prior adapting low dose of 14.80 MBq 18 F-FDG relative to controls (P < 0.019). A 0.74 MBq 18 F-FDG injection, which gives mice a dose approximately equal to a typical human PET scan, did not cause a significant increase in DNA damage nor did it generate an adaptive response. Typical 18 F-FDG injection activities used in small animal imaging (14.80 MBq) resulted in a decrease in DNA damage, as measured by γH2A.X formation, below spontaneous levels observed in control mice. Lastly, the 18 F-FDG RBE was <1.0, indicating that the mixed radiation quality and/or low dose rate from PET scans is less damaging than equivalent doses of gamma radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The ultraviolet flux envelopes of main-sequence B stars

Flux envelopes on an absolute energy scale from 1100 to 6000 A prepared from OAO-2 scans and from published ground-based material are presented for gamma Leporis, B0.5 5 eta Ursae Majoris, B3 5, gamma Ursae Majoris, A0 5, and alpha Lyrae, A0 5, and for alpha Canis Majoris Al 5 from rocket scans. These, with already published flux envelopes for Zeta Draconis, B6 3, and alpha Leonis, B7 5 (Underhill 1972) are intercompared and compared with reference flux envelopes predicted by LTE theory from lightly line-blanketed model atmospheres. A considerable line blocking occurs at wavelengths shortward of 3000 A with respect to the theoretical continuous spectra. The line blocking may be as much as 50 per cent at 1500 A and between 1500 A and 2500 A it is comparable to that which exists in the sun between 3000 A and 4000 A. Although gamma Urase Majoris, alpha Lyrae and alpha Canis Majoris have very similar visible spectra when viewed at low resolution, their ultraviolet spectra are significantly different, in particular alpha Lyrae shows an ultraviolet excess.

Underhill, A. B.↗

Impact of gamma-ray irradiation on hardened white Portland cement pastes exposed to atmosphere

Samples of matured hardened cement paste were exposed to an environment with gamma-ray irradiation, which induces a natural carbonation process. After a dose of approximately 5 x 10{sup 4} kGy, the physical properties, microstructure, and phase composition of the irradiated hardened cement paste samples are compared with those of reference samples exposed to an identical environment without gamma-ray irradiation. Experiments confirm that aragonite and vaterite are preferentially formed under irradiation and that the bending strength is dramatically increased after gamma-ray irradiation. Based on field-emission scanning electron microscopy observations, X-ray scattering profiles, and water vapor sorption isotherm data, it is concluded that vaterite formed on C–S–H plays a role in strengthening the structure of C–S–H via pseudomorphs.

36 MATERIALS SCIENCE↗

Probing eV-scale axions with CAST

We have searched for solar axions or other pseudoscalar particles that couple to two photons by using the CERN Axion Solar Telescope (CAST) setup. Whereas we previously have reported results from CAST with evacuated magnet bores (Phase I), setting limits on lower mass axions, here we report results from CAST where the magnet bores were filled with {sup 4}He gas (Phase II) of variable pressure. The introduction of gas generates a refractive photon mass m{sub {gamma}}, thereby achieving the maximum possible conversion rate for those axion masses m{sub a} that match m{sub {gamma}}. With 160 different pressure settings we have scanned m{sub a} up to about 0.4 eV, taking approximately 2 h of data for each setting. From the absence of excess x-rays when the magnet was pointing to the Sun, we set a typical upper limit on the axion-photon coupling of g{sub a{gamma}}{approx}<2.2 Multiplication-Sign 10{sup -10} GeV{sup -1} at 95% CL for m{sub a}{approx}<0.4 eV, the exact result depending on the pressure setting. The excluded parameter range covers realistic axion models with a Peccei-Quinn scale in the neighborhood of f{sub a} {approx} 10{sup 7} GeV. Currently in the second part of CAST Phase II, we are searching for axions with masses up to about 1.2 eV using {sup 3}He as a buffer gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of Nanosilicates on Poly(vinylidene fluoride) Crystal Polymorphism: Part 1. Melt-crystallization at High Supercooling

Polymorphism of poly(vinylidene fluoride), PVDF, in the presence of Lucentite STN organically modified silicate (OMS) is investigated for PVDF nanocomposites melt-crystallized at high supercooling temperatures where neat PVDF crystallizes exclusively in the alpha crystalline phase. Nanocomposites were prepared from solution with 0-1.0 wt% OMS composition. Here we observed that clay addition promotes gamma phase formation in nanocomposites melt-crystallized at high supercooling (i.e., at low crystallization temperature), whereas previously we showed that even small amount of nanosilicates resulted in beta phase formation in cold-crystallized PVDF nanocomposites. Wide-angle X-ray scattering (WAXS), Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC) studies showed that {alpha}- and {gamma}-phases co-existed in nanocomposites containing up to 0.1 wt% OMS, and the amount of {alpha}-crystals substantially diminished for higher OMS content. Formation of {gamma}-crystal phase was confirmed with morphologic observation of spherulites of low-birefringence using polarizing optical and atomic force microscopies, and their crystalline structures were verified by FTIR and Raman microscopic spectroscopy. We also address in this work the ambiguities in assessing PVDF crystallographic phases, and correct the phase identification errors which have persisted up to this point in the literature based on melting point confusion. The crystal phase identification for PVDF nanocomposites is discussed and clarified, based on X-ray scattering, vibrational spectra, and thermal analysis. For reference, we provide a vibrational band list, indicating the close, or overlapping bands, of the three phases of PVDF: {alpha}, {beta} and {gamma}.

36 MATERIALS SCIENCE↗

Stereological characterization of {gamma}' phase precipitation in CMSX-6 monocrystalline nickel-base superalloy

The purpose of this investigation was to study in detail the means to quantitatively evaluate {gamma}' phase precipitation. Many of the mechanical properties of superalloys are directly influenced by the presence of the {gamma}' (gamma prime) precipitate phase dispersed in a {gamma} matrix phase. The {gamma}' precipitates act as effective barriers to dislocation motion and restrict plastic deformation, particularly at high temperatures. Due to this, it is essential to accurately quantify the {gamma}' precipitate size, volume fraction and distribution. Investigations based on quantitative metallography and image analysis were performed on a monocrystalline nickel-base superalloy taking into consideration various {gamma}' precipitate sizes present in that alloy microstructure. The authors of the present paper propose a new method of quantifying the total volume fraction of the {gamma}' phase applying images of the microstructure with {gamma}' phase precipitates registered using light microscopy, scanning electron microscopy (at two different magnifications) and scanning transmission electron microscopy.

36 MATERIALS SCIENCE↗

Development of a Precision Scanning Optical Pulser for Low-Temperature Particle Detectors

Gamma-ray spectroscopy using low-temperature microcalorimeter arrays has demonstrated breakthrough energy resolution, establishing an important new technique for the precise characterization of radioactive samples. However, the extraordinary dynamic range of these pixels, spanning tens of electronvolts to hundreds of kiloelectronvolts, places stringent requirements on the calibration accuracy of each pixel. In this paper, we describe the design, development, and initial reflectivity-map testing of a new optical pulser intended for the precise determination of energy calibrations of microcalorimeter pixels and pixel arrays. A high-resolution XYZ scanner combined with 3 K optics achieving a 3-μm focused spot permit in situ imaging and precise placement of the energy deposition on the detector. Lastly, absolute absorbed power can be calibrated via a precision measurement of detector thermal stand-off.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Independent Verification of the Building 3550 Slab at Oak Ridge National Laboratory Oak Ridge, Tennessee

The Oak Ridge Institute for Science and Education (ORISE) has completed the independent verification survey of the Building 3550 Slab. The results of this effort are provided. The objective of this verification survey is to provide independent review and field assessment of remediation actions conducted by Safety and Ecology Corporation (SEC) to document that the final radiological condition of the slab meets the release guidelines. Verification survey activities on the Building 3550 Slab that included scans, measurements, and the collection of smears. Scans for alpha, alpha plus beta, and gamma activity identified several areas that were investigated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗