Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

X-ray escape peaks in gamma-ray spectrum acquired by perovskite detector

The X-ray escape peaks are clearly visible in the high-resolution gamma spectra acquired by CsPbBr 3 , credit to the rapidly improving energy resolution of perovskite gamma detectors. But it also raises concerns. If this peak remains as significant as it is, perovskite gamma detectors would have very limited use in complex gamma spectrometry applications. This paper discusses the origin of the escape peaks in CsPbBr 3 detectors, benchmarked against Ge and CZT detectors. The Pb escape peak consists of four escape peaks that are merged together, while the Cs and Br escape peaks are hidden inside the photopeak of 137 Cs (662 keV). These combined effects either create a noticeable gamma peak observed to the left of the 662 keV photopeak when acquired using a high-resolution CsPbBr 3 detector or raise the left slope of the photopeak. We also explore potential methods to mitigate these peaks, such as applying anti-coincidence method. The height of the escape peaks diminishes as the detector volume increases but will not go away entirely. The relationship between the observed Pb escape peak and the detector's dimensions is demonstrated through Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron and proton activation measurements from Skylab

Radioactivity induced by high-energy protons and secondary neutrons (from nuclear interactions) in various samples returned from different locations in Skylab was measured directly by gamma-ray spectroscopy measurements of decay gamma rays from the samples. Incident fluxes were derived from the activation measurements, using known nuclear cross-section. Neutron and proton flux values were found to range from 0.2 to 5 particles/sq cm-sec, depending on the energy range and location in Skylab. The thermal neutron flux was less than 0.07 neutrons/sq cm-sec. The results are useful for data analysis and planning of future high-energy astronomy experiments.

Fishman, G. J.↗

Fission Product Quantification and Burnup Analysis via Gamma Spectrometry of the AGR-5/6/7 TRISO Fuel Experiment

Five capsules containing varying configurations of TRISO fuel compacts were irradiated in the most recent Advanced Gas Reactor (AGR) TRISO test campaign, AGR-5/6/7. As part of the post-irradiation examination (PIE) of this work all the fuel compacts and capsule graphite holders were measured with the Precision Gamma Scanner (PGS) to determine isotopic activities and locations using gamma spectrometry. Measuring the compacts allowed for the comparison of physics model depletion calculations with the measured compact activity to validate models. These measurements also are used to find compacts of interest with low fission product retention that may be tested in subsequent PIE. Measurements of the holders can confirm fission product distribution and migration. Of the isotopes measured, Cs-137 and Cs-134 were used to estimate location of failed particles as well as determine a measured burnup estimation. Results from Capsule 1 compacts and the holder indicate many fuel particle failures occurred. There are high amounts of cesium in the holder near Stack 9 of Capsule 1 that corresponds to low fractions?measured-to-calculated (M/C) ratio?of cesium remaining in those compacts. All other capsules had cesium retention ratios near 1. The isotope 110mAg had less consistent results. Capsule 2 compacts exhibited a M/C of 0.20, much lower than anticipated for the temperatures these compacts underwent. Capsule 3 experienced much higher temperatures, >1300C and had an average M/C of 0.75. These are the opposite results than what was predicted by past AGR experiments for the relationship between temperature and isotope retention. Capsule 4 and 5 showed good fission product retention and agreement with the physics model predictions. The burnup results from the PGS measurements showed strong agreement between the physics models and the measured values. Using a ratio of Cs-134/Cs-137 to calculate the burnup match closely with the physics models. Additionally, the Cs-137 burnup results were less accurate but extremely close to the model results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma-ray burst and spectroscopy instrumentation development at the Goddard Space Flight Center

This paper summarizes the activities that are specifically related to the development of instrumentation for gamma-ray astronomy. Three programs are described: (1) the Gamma-Ray Imaging Spectrometer (GRIS), a balloon-borne array of seven germanium detectors for high-resolution spectrographic studies of persistent gamma-ray sources; (2) the Transient Gamma-Ray Spectrometer (TGRS), a single radiatively-cooled germanium detector for the spectrographic study of gamma-ray bursts, and (3) the Rapidly Moving Telescope (RMT), a ground-based optical telescope for the detection and study of short-lived optical transients, particularly those that occur in coincidence with gamma-ray bursts.

Teegarden, B. J.↗

X-ray remote sensing and in-situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in-situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. A calibration facility is being constructed at Schlumberger-Doll Research for gamma and x ray detectors. With this facility the detector response can be determined in an invariant and reproducible fashion. Initial use of the facility is expected for the MARS94 detectors. Work is continuing to better understand the rare earth oxyorthosilicates and to define their characteristics. This will allow a better use of these scintillators for planetary missions. In a survey of scintillating materials two scintillators were identified as promising candidates besides GSO, LSO, and YSO. These are CdWO4 and CsI(Tl). It will be investigated if a detector with a better overall performance can be assembled with various photon converters. Considerable progress was achieved in photomultiplier design. The length of an 1 inch diameter PMT could be reduced from 4.2 to 2.5 inches without performance degradation. This technology is being employed in the gamma ray detector for the NEAR project. A further weight and size reduction of the detector package can be achieved with miniaturized integrated power supplies.

Mahdavi, M.↗

Contamination, Transportation or Transmutation in LENR Material Analyses

LENR experiments using various loading and triggering mechanisms rely on a variety of elemental and isotopic assays to determine LENR effects. These assays include optical microscopy, Scanning Electron Microscopy with Energy Dispersive X-Ray Analysis (SEM/EDX), X-Ray Photoelectron Spectroscopy (XPS) and Transmission Electron Microscopy (TEM). All of these methods observe the surface of a material. By dissolving or vaporizing the sample, Inductively Coupled Plasma Optical Element Spectroscopy (ICP-OES) can determine elemental composition (ppb) or with mass spectroscopy, isotopes (ICP/MS). One can use a focused ion beam (FIB) to cut open a sample and observe the “cut” with either SEM/EDX, or Time-of-Flight Secondary Ion Mass Spectroscopy (TOF-SIMS). High Purity Gamma Ray Spectroscopy (HPGe) and alpha/ beta Liquid Scintillator spectroscopy can be used. We’ve employed these assay methods in our NASA GRC research under both the Advanced Energy Conversion and Lattice Confinement Fusion Projects. However, there are limitations associated with each of these methods ranging from handling contamination, instrumental limitations including sensitivity and field of view, and sample preparation.

Low Energy Nuclear Reactions↗

Ultra-low-level measurements of airborne fission products from the Fukushima Daiichi reactor accident using high volume collection systems at Savannah River National Laboratory

For this study, ultra-low-level measurements of radionuclides in air have been conducted at the Savannah River National Laboratory (SRNL) to determine the atmospheric concentration of fission products released following the Fukushima Daiichi reactor accident on March 11, 2011. Air filter samples were acquired from two high-volume collection systems (a traditional filter-based system and an electrostatic precipitator-based system) to monitor airborne radionuclide concentrations in the period covering from 2 weeks to 3 years after the disaster. The world-wide spread of low-level concentrations of airborne fission products from the Fukushima event provided a unique opportunity to demonstrate SRNL's electrostatic particle collection technology and other improvements in environmental monitoring developed at the Savannah River Site (SRS). Detecting and analyzing the release allowed a comprehensive test of SRS systems for monitoring environmental radioactivity. Gamma-ray-emitting fission products ( 131,132 I, 134,136,137 Cs, and 129,132 Te) and cosmogenic isotopes ( 7 Be and 22 Na) in air were detected and quantified by high-resolution gamma-ray spectroscopy at concentrations as low as 0.07 μBq per standard cubic meter (SCM) (50 mBq total 137 Cs), while plutonium content was quantified by thermal ionization mass spectrometry (TIMS) at concentrations as low as 6.5 × 10 –21 g/SCM (3.0 fg 239+240 Pu). Isotope concentrations measured at SRNL from gamma-ray spectroscopy were compared to independent measurements from Chapel Hill, NC, located approximately 370 km (230 mi) NE of SRNL. Meteorological modeling was also used to predict radionuclide transport from the location of release to both measurement locations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Characterization of the degradation of gamma-irradiated elastomers using Raman spectroscopy

This report presents key findings from Raman spectroscopic analysis of gamma-irradiated rubber samples extracted from a laminated lead-damped rubber (LDR) seismic isolation device. The samples were exposed to gamma radiation from a 60Co source in a Foss Therapy Services gamma irradiator, reaching absorbed doses up to 1600 kGy. A distinct threshold near 400 kGy was identified, beyond which significant spectral changes were observed. Two Raman peaks - at approximately 425 cm-1 and 2440 cm-1 - were tracked as a function of dose using Gaussian fitting. The 425 cm-1 peak, attributed to sulfur–sulfur (S–S) bond stretching (resulting from vulcanization of the rubber), exhibited a dose-dependent upshift, indicating radiation-induced crosslinking within the sulfur-based polymer network. Conversely, the 2440 cm-1 peak, likely associated with vibrational modes of additives or impurities, showed a downward shift with increasing dose, suggesting chain scission and degradation of non-rubber constituents. These results provide first-of-a-kind insights into the microstructural evolution of elastomers under high-dose gamma irradiation and establish a preliminary dose threshold for significant degradation. Future work will incorporate multi-modal characterization—including Fourier Transform Infrared (FTIR) spectroscopy, scanning electrom microscopy (SEM) of the rubber surface morphology, thermogravimetric analysis (TGA) to determine changes in thermal stability, and mechanical testing—to correlate molecular-level changes with macroscopic performance of these elastomers as damping media in seismic isolation devices. These findings are expected to provide regulatory guidance and design criteria for qualifying low-damping rubber seismic isolators in advanced nuclear reactor applications.

36 - MATERIALS SCIENCE↗

In-beam γ-ray spectroscopy of 37–42 P

The level schemes of the neutron-rich 37-42 P isotopes are investigated via in-beam gamma-ray spectroscopy following the fragmentation of a 45 Cl projectile beam at intermediate beam energies. Information on gamma-gamma coincidence relationships complemented by comparisons to shell-model calculations in the sd-pf model space were used to construct excitation level schemes for these neutron-rich nuclei. For the odd-mass 37,39 P isotopes, a level scheme is presented that appears essentially complete at low energies and exhausts the states predicted by the SDPF-MU shell-model Hamiltonian. In conclusion, simple Nilsson configurations are proposed for the low-lying excited states of 38,39,40,41 P from an analysis of the E2 transition matrix elements and moments calculated within the shell model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel methodology for gamma-ray spectra dataset procurement over varying standoff distances and source activities

The adoption of machine learning approaches for gamma-ray spectroscopy has received considerable attention in the literature. Many studies have investigated the deployment of various algorithm architectures to a specific task. However, little attention has been afforded to the development of the datasets leveraged to train the models. Such training datasets typically span a set of environmental or detector parameters to encompass a problem space of interest to a user. Variations in these measurement parameters will also induce fluctuations in the detector response, including expected pile-up and ground scatter effects. Fundamental to this work is the understanding that 1) the underlying spectral shape varies as the measurement parameters change and 2) the statistical uncertainties associated with two spectra impact their level of similarity. While previous studies attribute some arbitrary discretization to the measurement parameters for the generation of their synthetic training data, this work introduces a principled methodology for efficient spectral-based discretization of a problem space. A signal-to-noise ratio (SNR) respective spectral comparison measure and a Gaussian Process Regression (GPR) model are used to predict the spectral similarity across a range of measurement parameters. This innovative approach effectively showcased its capability by dividing a problem space, ranging from 5 cm to 100 cm standoff distances and 5 μCi–100 μCi of 137 Cs, into three unique combinations of measurement parameters. The findings from this work will aid in creating more robust datasets, which incorporate many possible measurement scenarios, reduce the number of required experimental test set measurements, and possibly enable experimental training data collection for gamma-ray spectroscopy.

data science↗

Gamma-ray constraints on supernova nucleosynthesis

Gamma-ray spectroscopy holds great promise for probing nucleosynthesis in individual supernova explosions via short-lived radioactivity, and for measuring current global Galactic supernova nucleosynthesis with longer-lived radioactivity. It was somewhat surprising that the former case was realized first for a Type II supernova, when both Co-56 and Co-57 were detected in SN 1987A. These provide unprecedented constraints on models of Type II explosions and nucleosynthesis. Live Al-26 in the Galaxy might come from Type II supernovae, and if it is eventually shown to be so, can constrain massive star evolution, supernova nucleosynthesis, and the Galactic Type II supernova rate. Type Ia supernovae, thought to be thermonuclear explosions, have not yet been detected in gamma-rays. This is somewhat surprising given current models and recent Co-56 detection attempts. Ultimately, gamma-ray measurements can confirm their thermonuclear nature, probe the nuclear burning conditions, and help evaluate their contributions to Galactic nucleosynthesis. Type Ib/c supernovae are poorly understood. Whether they are core collapse or thermonuclear events might be ultimately settled by gamma-ray observations. Depending on details of the nuclear processing, any of these supernova types might contribute to a detectable diffuse glow of Fe-60 gamma-ray lines. Previous attempts at detection have come very close to expected emission levels. Remnants of any type of age less that a few centuries might be detectable as individual spots of Ti-44 gamma-ray line emission. It is in fact quite surprising that previous surveys have not discovered such spots, and the constraints on the combination of nucleosynthesis yields and supernova rates are very interesting. All of these interesting limits and possibilities mean that the next mission, International Gamma-Ray Astrophysics Laboratory (INTEGRAL), if it has sufficient sensitivity, is very likely to lead to the realization of much of the great potential of gamma-ray spectroscopy for understanding supernovae.

Leising, Mark D.↗

Optimization of an Energy Tuning Assembly for High Explosives Detection

The Portable Isotopic Neutron Spectroscopy (PINS) system, employs neutron-induced gamma-ray spectroscopy and provides a nondestructive method for high explosives detection. In standard operation it uses Californium-252 as a neutron source. Operating PINS with a deuterium-tritium (DT) neutron generator has some advantages over Cf-252, including lifetime and ability to produce high-energy inelastic scattering gamma rays. However, current systems using DT neutron generators suffer from a high environmental background and reduced ability to induce neutron capture, reducing spectral quality and limiting nitrogen sensitivity. Here, this study presents the development of an energy-tuning assembly (ETA) designed to optimize the DT neutron energy spectrum to increase nitrogen reaction rates in a target, thereby improving high explosive detection capabilities. A metaheuristic optimization framework, MultiGNOWEE, coupled with MCNP, was employed to generate two ETA configurations: a single-objective ETA, which maximizes nitrogen capture reactions, and a multi-objective ETA, which balances neutron capture and inelastic scattering. Simulations demonstrated the optimized configurations achieved up to a 10-fold improvement in nitrogen capture rates compared to the bare configuration. Experimental validation was conducted using a DT neutron generator and a high-purity germanium (HPGe) detector. Two prototype ETAs were constructed and assessed on a melamine simulant. Measurements demonstrated improved nitrogen detection for both prototype ETA configurations when compared to the standard system.

97 MATHEMATICS AND COMPUTING↗

The Spectral Properties of Gamma-ray Bursts: a Review of Recent Development

Developments in the spectroscopy of gamma ray bursts (GRB) are reviewed. The general question of the validity of the spectral results, particularly with regard to features in the spectrum, is discussed. Confirmations of these spectral features are summarized. Results from the KONUS experiments on Venera 13 and 14 are reviewed. The status of models of the continuum spectrum is summarized. A number of different radiation mechanisms appear capable of fitting the data. These include thermal bremsstrahlung, thermal synchrotron and inverse Compton. Rapid variability of the spectra shape on time scales 76] 0.25 sec. was reported. The characteristic energy of the spectrum was observed to vary over nearly an order of magnitude during individual events. A strong correlation between spectral hardness and luminosity was found. Low-energy (50 keV) absorption features and high-energy (400 keV) emission features continue to appear in GRB spectra. Understanding the origin of these lines in the context of the existing continuum models remains a difficult problem.

Teegarden, B. J.↗

HERMES-400 Microcalorimetry Measurements of Nuclear Fuel at Idaho National Laboratory

Microcalorimetry updates from HERMES-400 located at Idaho National Laboratory will be presented. In particular, the current outlook as well as future upgrades will be discussed. Data will be presented for Byron and TRISO particle fuel measurements highlighting improved energy resolution compared to traditional gamma-ray spectroscopy.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring Gamma-Ray and Neutron Spectroscopy Missions to Mars Caves [Slides]

In this work, we investigate the sensitivity of active neutron detector systems in Mars caves using MCNP6 to model neutron transport in different cave geometries, compositions, and detectors to determine if active neutron measurements can be used to identify the hydration of cave walls vs floor vs ceilings, and to perform a concept study for potential future Mars cave missions in search of hydration and habitable regions.

79 ASTRONOMY AND ASTROPHYSICS↗

High resolution spectroscopy of two gamma-ray bursts in November 1978

The first results from the ISSEE-3 radiatively colled germanium gamma ray burst spectrometer are presented. Spectra and time histories from two events on the 1978 November 4 and 1978 November 19 are given. A significant difference in the continuum spectra for the two events was observed. Evidence is presented for two spectral features in the features in the November 19 events, a broad one at approximately 420 key KeV and a narrower one at 740 KeV with a suggestion of an accompanying high energy tail.

Teegarden, B. J.↗

High-resolution spectroscopy of two gamma-ray bursts in 1978 November

The first results from the ISEE 3 radiatively cooled germanium gamma-ray burst spectrometer are presented. Spectra and time histories from two events on 1978 November 4 and 19 are given. A significant difference in the continuum spectra for the two events was observed. Evidence is presented for two spectral features in the November 19 event, a broad one at about 420 keV and a narrower one at about 740 keV with a suggestion of an accompanying high-energy tail.

Teegarden, B. J.↗

BATSE spectroscopy catalog of bright gamma-ray bursts

This paper presents comprehensive results on the spectra of 30 bright gamma ray bursts (GRBs) as observed by the Spectroscopy Detectors (SDs) of the Burst And Transient Source Experiment (BATSE). The data selection was strict in including only spectra that are of high reliability for continuum shape studies. This BATSE Spectroscopy Catalog presents fluences, model fits (for five spectral models for three energy ranges), and photon spectra in a standard manner for each burst. Complete information is provided to describe the data selection and analysis procedures. The catalog results are also presented in electronic format (from the Compton Observatory Science Support Center) and CD-ROM format (AAS CD-ROM series, Vol. 2). These electronic formats also present the count spectra and detector response matrices so as to allow for independent study and fitting by researchers outside the BATSE Team. This BATSE Spectroscopy Catalog complements the catalog from BATSE Large Area Detector (LAD) data by Fishman et al. (1994).

Schaefer, Bradley E.↗