Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Measurement of the Neutron Elastic Electromagnetic Form Factor Ratio at Large Momentum Transfer

Exploring nucleon structure is vital both for understanding its origin and existence as well as for the advancement of the sciences. It helps us answer key questions such as how quark and gluon dynamics create 99% of the nucleon mass. Electron- nucleon scattering has been widely used for precision studies of the nucleon and nuclear structure since the Nobel Prize winning investigations by Robert Hofstadter and collaborators in the 1950s. These studies provide information about the spatial charge and current densities of the nucleon in terms of the electromagnetic form factors. The form factors are functions of four momentum transfer squared (Q2). Extending the electromagnetic form factor measurements to higher Q2 plays a critical role in furthering the understanding of nucleon structure. This motivated the Super BigBite Spectrometer (SBS) program at Jefferson Lab. The open nature of the spectrometers and the direct line of sight from the target to the tracking detector locations in experimental setups such as SBS creates high levels of background at the detectors. This necessitates the use of tracking detectors with high rate capability and good position resolution. Gas Electron Multiplier (GEM) detectors are an excellent choice for tracking detectors in such experiments. Understanding the performance of the GEM detectors is important not just for SBS experiments but also for future high-luminosity experiments. This thesis reports the exploratory results from the measurement of the neutron elastic electromagnetic form factor ratio (Gn E/Gn M) at high momentum transfer. A longitudinally polarized electron beam was scattered off a polarized 3He target, used as an effective polarized neutron target. In this experiment, the polarized 3He target achieved a world record polarization weighted luminosity at a beam current of 45 µA. Double spin asymmetry of the scattered neutron events is used to extract the neutron form factor ratio. Measurements were taken at Q2 = 3.0, 6.8, 9.8 (GeV/c)2. The lowest Q2 measurement is in good agreement with the existing world data, and the higher-Q2 measurements extend the Q2 reach well beyond the existing world data and are expected to remain unmatched for a long time.

Gamage, Vimukthi Haththotuwa [Univ. of Virginia, C↗

Fire detector response in aircraft applications

Photoelectric, ionization, and gas sensors were used to detect the signatures from the radiant heat or flame of various aircraft materials. It was found that both ionization and photoelectric detectors are about equally capable of detecting products of pyrolysis and combustion of synthetic polymers, especially those containing fire-retardant additives. Ionization detectors alone appeared to be sensitive to combustion products of simple cellulosic materials. A gas sensor detector appeared to be insensitive to pyrolysis or combustion products of many of the materials.

Wiersma, S. J.↗

Electronics integration for the GE2/1 and ME0 GEM detector systems for the CMS phase-2 muon system upgrade

Abstract The Large Hadron Collider is currently undergoing its High Luminosity upgrade, which is set to increase the instantaneous luminosity by about a factor of five. Consequently, the Compact Muon Solenoid experiment is upgrading its muon spectrometer to cope with the increased muon flux in the forward region. The GE2/1 triple-gas electron multiplier detector, which has recently entered the mass production phase, and the ME0 triple-GEM detector system, which is in the late prototyping phase, are undergoing electronics integration. These proceedings briefly discuss the frontend electronics for the GE2/1 and ME0 detector systems, the electronics integration testing process, and the future plans for the frontend electronics of these two detector systems by the CMS GEM collaboration.

Instruments & Instrumentation↗

The Vacuum Cherenkov Detector (VCD) for γ-ray measurements in inertial confinement fusion experiments

Inertial confinement fusion experiments at both the National Ignition Facility (NIF) and the Laboratory for Laser Energetics OMEGA laser facility currently utilize Cherenkov detectors, with fused silica as the Cherenkov medium. At the NIF, the Quartz Cherenkov Detectors improve the precision of neutron time-of-flight measurements; and at OMEGA, the Diagnostic for Areal Density provides measurements of capsule shell areal densities. An inherent property of fused silica is the radiator’s relatively low energy threshold for Cherenkov photon production (E threshold < 1 MeV), making it advantageous over gas-based Cherenkov detectors for experiments requiring low-energy γ detection. The Vacuum Cherenkov Detector (VCD) has been specifically designed for efficient detection of low energy γ’s. Its primary use is in implosion experiments, which will study reactions relevant to stellar and big-bang nucleosynthesis, such as T( 4 He,γ) 7 Li, 4 He( 3 He,γ) 7 Be, and 12 C(p,γ) 13 N. Further, the VCD is compatible with LLE’s standard Ten-Inch Manipulator diagnostic insertion module. This work will outline the design and characterization of the VCD as well as provide results from recent experiments conducted at the OMEGA laser facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectroscopy in X-ray astronomy

Detailed features in cosmic X-ray sources and their associated temporal variation over a wide energy range were studied. Excess emission and absorption at approximately 6 to 7 kiloelectron volts in the spectra of supernova remnants, binary X-ray sources, and clusters of galaxies were observed. A gas scintillation proportional counter (GSPC) will be used as the detector system. In the gas scintillator the principal limitation is due to the statistics of the initial ionization process only.

Andresen, R.↗

Technical Assistance for RingIR Aerosol Penetration Study with RingIR

Sandia provided technical assistance to RingIR to test and evaluate of the RingIR molecular detector. The detector can identify gas phase species using molecular fingerprinting and has potential application for SARS-CoV-2 detection in near real time. As part of the development process Sandia will utilize the biological aerosol test bed deployed at the Aerosol Complex to evaluate the penetration of MS2 bacteriophage aerosol through the RingIR system. The objective of this project is to provide experimentally derived measurements of the RingIR molecular detector penetration efficiency, including external exhaust filter for mitigation of exhaust aerosol and operation using MS2 bacteriophage as a biological surrogate to the SARS-CoV-2 virus.

59 BASIC BIOLOGICAL SCIENCES↗

Real-Time Monitoring of Gas-Phase and Dissolved CO 2 Using a Mixed-Matrix Composite Integrated Fiber Optic Sensor for Carbon Storage Application

Novel chemical sensors that improve detection and quantification of CO 2 are critical to ensuring safe and cost-effective monitoring of carbon storage sites. Fiber optic (FO) based chemical sensor systems are promising field-deployable systems for real-time monitoring of CO 2 in geological formations for long-range distributed sensing. Here, a mixed-matrix composite integrated FO sensor system was developed with a purely optical readout that reliably operates as a detector for gas-phase and dissolved CO 2 . A mixed-matrix composite sensor coating consisting of plasmonic nanocrystals and hydrophobic zeolite embedded in a polymer matrix was integrated on the FO sensor. The mixed-matrix composite FO sensor showed excellent reversibility/stability in a high humidity environment and sensitivity to gas-phase CO 2 over a large concentration range. This remarkable sensing performance was enabled by using plasmonic nanocrystals to significantly enhance the sensitivity and a hydrophobic zeolite to effectively mitigate interference from water vapor. The sensor exhibited the ability to sense CO 2 in the presence of other geologically relevant gases, which is of importance for applications in geological formations. A prototype FO sensor configuration which possesses a robust sensing capability for monitoring dissolved CO 2 in natural water was demonstrated. Reproducibility was confirmed over many cycles, both in a laboratory setting and in the field. More importantly, we demonstrated on-line monitoring capabilities with a wireless telemetry system, which transferred the data from the field to a website. The combination of outstanding CO 2 sensing properties and facile coating processability makes this mixed-matrix composite FO sensor a good candidate suitable for practical carbon storage applications.

54 ENVIRONMENTAL SCIENCES↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

Novel infrared detector based on a tunneling displacement transducer

The paper describes the design, fabrication, and characteristics of a novel infrared detector based on the principle of Golay's (1947) pneumatic infrared detector, which uses the expansion of a gas to detect infrared radiation. The present detector is constructed entirely from micromachined silicon and uses an electron tunneling displacement transducer for the detection of gas expansion. The sensitivity of the new detector is competitive with the best commercial pyroelectric sensors and can be readily improved by an order of magnitude through the use of an optimized transducer.

Kenny, T. W.↗

Monolayer Sc 2 CF 2 as a Potential Selective and Sensitive NO 2 Sensor: Insight from First-Principles Calculations

Two-dimensional materials with excellent surface–volume ratios and massive reaction sites recently have been receiving attention for gas sensing. With first-principles calculations, we explored the performance of monolayer Sc 2 CF 2 as a gas sensor. We investigated how molecule adsorption affects its electronic structure and optical properties. It is found that a large charge transfer quantity happens between Sc 2 CF 2 and NO 2 , which results from the fact that the lowest unoccupied molecular orbital (LUMO) of NO 2 is below the valence band maximum (VBM) of Sc 2 CF 2 . Moreover, the MD simulation shows that NO 2 can adsorb on the Sc 2 CF 2 surface stably at room temperature. We explored the effect of biaxial strain on the adsorption energy and charge transfer quantity of each system, and the results show that the biaxial strain can enhance both the adsorption energy and charge transfer quantity of the NO 2 system and thus can improve the sensitivity of Sc 2 CF 2 in detecting the NO 2 molecule. Furthermore, we investigated the adsorption behavior and charge transfer of polar polyatomic molecules at the Sc 2 CF 2 surface with h-BN as a substrate, and the results demonstrate that the h-BN substrate can hardly modify the main results. Our result predicts that Sc 2 CF 2 can be a promising selective and sensitive sensor to detect the NO 2 molecule, and could also give a theoretical guide for other terminated MXenes used for gas sensors or detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fission Gas Monitoring System Efficiency Calibration Summary Report

The Fission Gas Monitoring System was designed to work in conjunction with the Fuel Accident Condition Simulator Furnace and is used to measure fission gas releases during post-irradiation fuel heating tests. A high-purity helium sweep gas is swept past the heated fuel sample in the furnace and routed to a fission gas monitoring system, which cryrogenically traps the krypton (Kr) and xenon (Xe) fission gases. As the radioactive species of the trapped gas decays, high-purity germanium detectors monitor the amount of fission gas in each trap. The primary fission product present in this test is 85Kr, which has a 10.76-year half-life. The presence of 85Kr indicates particle defects and iodine release. There is also the potential for re-irradiating the fuel compacts in the Neutron Radiography Reactor in the Hot Fuel Examination Facility basement. With re-irradiation, it is possible to have xenon fission gas present, specifically 133Xe, which has a 5.243-day half-life. Re-irradiation also produces 131I, which is important for design-basis accidents and regulatory licensing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RingIR AG-4000 Testing

The AG-4000 detector can identify gas phase species using molecular fingerprinting and has potential application for SARS-CoV-2 detection in near real time. As part of the development process Sandia will utilize the biological aerosol test bed deployed at the Aerosol Complex to evaluate the penetration of MS2 bacteriophage aerosol through the Ring IR system. The objective of this project is to provide experimentally derived measurements of the RingIR AG-4000 penetration efficiency, including external exhaust filter for mitigation of exhaust aerosol and operation using MS2 bacteriophage as a biological surrogate to the SARS-CoV-2 virus.

60 APPLIED LIFE SCIENCES↗

Chemical ionization mass spectrometry utilizing benzene cations for measurements of volatile organic compounds and nitric oxide

We evaluate the capability of chemical ionization mass spectrometry (CIMS) using benzene cations as reagent ions (benzene CIMS) for detecting atmospheric trace gases. We characterize the ionization pathways and product ion distributions for 27 analytes spanning diverse chemical classes. To interpret the complex ion chemistry involving two reagent ions (C 6 H$^{+}_{6}$ and (C 6 H 6 )$^{+}_{2}$) and multiple ionization pathways (charge transfer, proton transfer, adduct formation, and hydride abstraction), we introduce a thermodynamics-based framework that classifies analytes into three categories based on their ionization energy (IE), relative to those of benzene monomer (9.24 eV) and dimer (8.69 eV). Each class exhibits distinct ionization mechanisms and product ions. Analytes with IE smaller than 8.69 eV (low IE) undergo charge transfer with both reagent ions; analytes with IE between 8.69 and 9.24 eV (mid IE) undergo charge transfer with C 6 H$^{+}_{6}$ and potential adduct formation with (C 6 H 6 )$^{+}_{2}$; analytes with IE larger than 9.24 eV (high IE) could undergo adduct formation, proton transfer, or hydride abstraction. Analytes within each class also show similar sensitivity, enabling sensitivity estimation for compounds lacking calibration standards. In addition to volatile organic compounds (VOCs), benzene CIMS detects nitric oxide (NO) with a detection limit of 5 pptv for 1 min integration time, exceeding the performance of most commercial NOx analyzers. Field deployments in Chicago and St. Louis demonstrate good agreement with reference NO measurements. Isoprene measurements show good agreement with a co-located gas chromatography–photoionization detector (GC-PID) in St. Louis, but exhibit substantial positive bias in Chicago, likely due to interferences from anthropogenic VOCs in the polluted urban environment. These results highlight the potential of benzene CIMS for concurrent measurements of NO, VOCs, and their oxidation products using a single instrument, while also underscoring challenges in complex atmospheric conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Definition phase study of the grand tour missions

The research to define an energetic particle experiment for the OPTGT-MJS missions is reported. The studies reported include: (1) the use of silicon dectectors for low energy, low flux level measurements in the presence of RTG radiation and trapped electrons, (2) high energy proton damage of lithium-drifted and surface barrier silicon detectors, (3) the gas Cerenkov counter, (4) systems for detection of trapped high-energy protons in the presence of trapped electrons, and (5) reliability and redundancy.

Simpson, J. A.↗

Advances in solar and cosmic X-ray astronomy - A survey of experimental techniques and observational results.

The current status of X-ray astronomy is surveyed by reviewing observational results and theoretical conclusions gained within the past two years in areas dealing with the quiet-sun, slowly-varying, and burst components of solar X-radiation and with the features of cosmic X-ray sources. Thermal and nonthermal processes responsible for a wide variety of X-ray emission mechanisms in nature are explained, and characteristics of X radiation from specific solar structures are described. Attention is given to the effects of interstellar and intergalactic matter on cosmic X-rays; the properties of galactic and extragalactic X-ray sources; and the specifications of such instruments as gas-filled ionization detectors, proportional counters, Geiger counters, scintillation detectors, photoelectric detectors, polarimeters, collimators, spectrometers, and imaging systems.

Hoover, R. B.↗

Use of dew-point detection for quantitative measurement of sweating rate

A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

Brengelmann, G. L.↗

Sealed high-pressure x-ray detector

Detector is filled to pressure of 2 atm with mixture of 95% xenon and 5% methane for recording hard x-ray (50-to100-keV0 images with spatial resolution of about 1 mm. Being sealed, detector requires no gas purification or replenishment after initial fill. Potential areas of application include nuclear medicine, and x-ray or gamma-ray astronomy.

Gorenstein, P.↗