An open-source, automated, gas sampling peripheral for laboratory incubation experiments using cavity ring-down spectroscopy
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
An experimental study is conducted on the possibility and viability of performing spectrochemical analysis of carbon and other elements in trace amount in Mars, in particular, the clean detection of C, which is indispensible for tracking the sign of life in Mars. For this study, a nanosecond Nd-YAG laser is employed to generate plasma emission from a pure copper target in CO{sub 2} ambient gas of reduced pressure simulating the atmospheric condition of Mars. It is shown that the same shock wave excitation mechanism also works this case while exhibiting remarkably long cooling stage. The highest Cu emission intensities induced by 4 mJ laser ablation energy is attained in 600 Pa CO{sub 2} ambient gas. Meanwhile the considerably weaker carbon emission from the CO{sub 2} gas appears relatively featureless over the entire range of pressure variation, posing a serious problem for sensitive trace analysis of C contained in a solid sample. Our time resolved intensity measurement nevertheless reveals earlier appearance of C emission from the CO{sub 2} gas with a limited duration from 50 ns to 400 ns after the laser irradiation, well before the initial appearance of the long lasting C emission from the solid target at about 1 μs, due to the different C-releasing processes from their different host materials. The unwanted C emission from the ambient gas can thus be eliminated from the detected spectrum by a proper time gated detection window. The excellent spectra of carbon, aluminum, calcium, sodium, hydrogen, and oxygen obtained from an agate sample are presented to further demonstrate and verify merit of this special time gated LIBS using CO{sub 2} ambient gas and suggesting its viability for broad ranging in-situ applications in Mars.
This is the AmeriFlux version of the carbon flux data for the site US-Bsg Burns Sagebrush. Site Description - The site was established in 2012 and is part of a NOAA observation network for high precision measurements of carbon dioxide concentrations. It is located about 60 km southwest of Burns, Oregon in the Oregon High Desert. The vegetation in this area is dominated by sagebrush. The sampling inlets are at the heights of 18.5, 28.5, and 38.5 m. Gas analysis is performed with a Picarro 2302 Cavity Ringdown Spectrometer and a Li-Cor 7200 enclosed path IRGA. The tower is also equipped with a set of meteorological instruments, including an HMP sensor, radiation sensors (incoming and diffuse PAR, Net radiometer), and a CSAT3 sonic anemometer. This site is also part of the PhenoCam network operated by Harvard University and the University of New Hampshire.
New Composite Membranes for High Throughput Solid-Liquid Separations at the Savannah River Site R. Bhave (Oak Ridge National Laboratory. Oak Ridge, TN) and M. R. Poirier* (Savannah River National Laboratory, Aiken SC) Solid-liquid separation is the limiting step for many waste treatment processes at the Savannah River Site. SRNL researchers have identified the rotary microfilter as a technology to improve the rate of solid-liquid separation processes. SRNL is currently developing the rotary microfilter for radioactive service and plans to deploy the technology as part of the small column ion exchange process. The rotary microfilter can utilize any filter media that is available as a flat sheet. The current baseline membrane is a 0.5 micron (nominal) porous metal filter (Pall PMM050). Previous testing with tubular filters showed that filters composed of a ceramic membrane on top of a stainless steel support produce higher flux than filters composed only of porous metal. The authors are working to develop flat sheet filter media composed of a ceramic membrane and/or ceramic-metal composite on top of a porous stainless steel support that can be used with the rotary microfilter to substantially increase filter flux resulting in a more compact, energy efficient and cost-effective high level radioactive waste treatment system. Composite membranes with precisely controlled pore size distribution were fabricated on porous metal supports. High quality uniform porous metal (316SS) supports were fabricated to achieve high water permeability. Separative layers of several different materials such as ultrafine metal particles and ceramic oxides were used to fabricate composite membranes. The fabrication process involved several high temperature heat treatments followed by characterization of gas and liquid permeability measurements and membrane integrity analysis. The fabricated composite membrane samples were evaluated in a static test cell manufactured by SpinTek. The composite membranes were evaluated on several feed slurries: 1 wt. % strontium carbonate in deionized water, 1 wt. % monosodium titanate in simulated salt solution, and 1 wt. % simulated sludge in simulated salt solution and deionized water. Flux as a function of feed flow rate and transmembrane pressure was measured for each of the above described feed slurries. The authors will discuss the new membrane development efforts, waste slurry filtration performance evaluations and scale-up considerations.
The reaction between SiO(g) and CO(g) is a relevant intermediate reaction in the silicon production process. One of the products generated from this gas mixture is called by its color, brown condensate. In this paper, SiO(g) and CO(g) are produced from SiO{sub 2}-SiC pellets. The reaction between the two gases occurred on SiC particles. Inert gas was injected at different flows. The SiC particles were collected, and the brown condensate deposited on them was characterized by electron probe microanalysis, X-ray photoelectron spectroscopy, and focused ion beam preparation samples for transmission electron microscope analysis. The brown condensate consists of a mixture of Si spheres embedded in a SiO{sub 2} matrix. The compound generates in the temperature range from 1400 °C to 1780 °C (1673 K to 2053 K), and in the SiO(g) partial pressure range between 0.534 and 0.742, depending on the inert gas flow. SiC crystallites are located at the Si-SiO{sub 2} interface. Carbides are believed to generate from the reaction between liquid silicon and CO(g). Carbides may also precipitate from reaction between dissolved carbon and liquid silicon, but to a minor extent. Both mechanisms are believed to happen above the melting point of silicon and in the softening range of silica.
A rapid detection of heavy metals in soil was presented by the metal-assisted gas plasma method using specific characteristics of a pulsed, transversely excited atmospheric (TEA) CO{sub 2} laser. The soil particles were placed in a hole made of acrylic plate. The sample was covered by a to prevent the soil particles from being blown off. The mesh also functioned to initiate a luminous plasma. When a TEA CO{sub 2} laser (1500 mJ, 200 ns) was focused on the soil sample, passing through the metal mesh, some of the laser energy was used to generate the gas plasma on the mesh surface, and the remaining laser energy was employed to ablate the soil particles. The fine, ablated soil particles moved into the gas plasma region to be dissociated and excited. Using this technique, analysis can be made with reduced sample pretreatment, and therefore a rapid analysis can be performed efficiently. The results proved that the signal to noise ratio (S/N) of the emission spectral lines is much better for the case of the present method (mesh method) compared to the case of standard laser-induced breakdown spectroscopy using the pellet method. Rapid detection of heavy metal elements in soil has been successfully carried out. The detection limits of Cu and Hg in soil were estimated to be 3 and 10 mg/kg, respectively. The present method has good potential for rapid and sensitive detection of heavy metals in soil samples.
The main objective of the project was to develop a post-combustion CO 2 capture process based on the hybrid cold temperature membrane operation. The CO 2 in the flue gas from coal fired power plant is pre-concentrated to >60% CO 2 in the first stage membrane operation followed by further liquefaction of permeate stream to achieve >99% CO 2 purity. The aim of the project was based on DOE program goal of 90% CO 2 capture with >95% CO 2 purity from Pulverized Coal (PC) fired power plants with $40/tonne of carbon capture cost by 2025. The project moves the technology from TRL 4 to TRL 5. The project involved optimization of Air Liquide commercial 12” PI-1 bundle to improve the bundle productivity by >30% compared to the previous baseline (DE-FE0004278) using computational fluid dynamics (CFD) modeling and bundle testing with synthetic flue gas at 0.1 MWe bench scale skid located at Delaware Research and Technology Center (DRTC). In parallel, the next generation polyimide based novel PI-2 membrane was developed with 10 times CO 2 permeance compared to the commercial PI-1 membrane. The novel PI-2 membrane was scaled from mini-permeator to 1” permeator and 1” bundle for testing. Bundle development was conducted with a Development Spin Unit (DSU) installed at MEDAL. Air Liquide’s cold membrane technology was demonstrated with real coal fired flue gas at the National Carbon Capture Center (NCCC) with a 0.3 MWe field-test unit (FTU). The FTU was designed to incorporate testing of two PI-1 commercial membrane bundles (12” or 6” diameter) in parallel or series. A slip stream was sent to the next generation PI-2 membrane for testing with real flue gas. The system exceeded performance targets with stable PI-1 membrane operation for over 500 hours of single bundle, steady state testing. The 12” PI-1 bundle exceeded the productivity target by achieving ~600 Nm3/hr, where the target was set at ~455 Nm3/hr at 90% capture rate. The cost of 90% CO 2 capture from a 550 MWe net coal power plant was estimated between 40 and $45/tonne. A 6” PI-1 bundle exhibited superior bundle performance compared to the 12” PI-1 bundle. However, the carbon capture cost was not lower with the 6” PI-1 bundle due to the higher bundle installed cost. A 1” PI-1 bundle was tested to compare bundles with different length / diameter ratios. This bundle exhibited the lowest performance due to the different fiber winding pattern and increased bundle non-ideality. Several long-term and parametric tests were conducted with 3,200 hours of total run-time at NCCC. Finally, the new PI-2 membrane fiber was tested at a small scale (1” modules) in real flue gas and exhibited up to 10 times the CO 2 permeance and slightly lower CO 2 /N 2 selectivity as the commercial PI-1 fiber. This corresponded to a projected 4 - 5 times increase in the productivity per bundle and a potential cost reduction of $3/tonne for CO2 capture, as compared with PI-1. An analytical campaign was conducted to trace different impurities such as NOx, mercury, Arsenic, Selenium in gas and liquid samples through the carbon capture system. An Environmental, Health and Safety (EH&S) analysis was completed to estimate emissions from a 550 MWe net power plant with carbon capture using cold membrane. A preliminary design and cost analysis was completed for 550 tpd (~25 MWe) plant to assess the capital investment and carbon capture cost for PI-1 and PI-2 membrane solutions from coal fired flue gas. A comparison was made with an amine based solution with significant cost advantage for the membrane at this scale. Additional preliminary design and cost analysis was completed between coal, natural gas and SMR flue gas for carbon capture at 550 tpd (~25 MWe) plant.
A brief description of the results of joint analysis of data obtained in long-term measurements of krypton samples differing in {sup 78}Kr content is presented. Low-background high-pressure proportional gas counters were used as detectors. The comparative analysis of experimental data on single and double K -capture provided the first estimate of the probability of production of a double K -shell vacancy in the process of K -shell electron capture in {sup 81}Kr: P{sub KK}=[5.7±0.8 (stat.)±0.4 (syst.)]×10{sup −5}. A new result for the half-life of {sup 78}Kr with respect to the 2K(2ν)-mode was also obtained: T{sub 1/2}=[1.9{sub −0.7}{sup +1.3} (stat.)±0.3 (syst.)]×10{sup 22} years (90% CL).
Radiochemical diagnostic techniques such as gas-phase capsule debris analysis may prove to be successful methods for establishing the success or failure of ignition experiments at the National Ignition Facility (NIF). Samples in the gas phase offer the most direct method of collection by simply pumping out the large target chamber following a NIF shot. The target capsules will be prepared with dopants which will produce radioactive noble gas isotopes upon activation with neutrons. We have designed and constructed the Radchem Apparatus for Gas Sampling (RAGS) in order to collect post-shot gaseous samples for NIF capsule diagnostics. The design of RAGS incorporates multiple stages intended to purify, transfer, and count the radioactive decays from gaseous products synthesized in NIF experiments. At the moment the dopant of choice is {sup 124}Xe, which will undergo (n,{gamma}) and (n, 2n) reactions to produce {sup 125}Xe and {sup 123}Xe. The half-lives of each are on the order of multiple hours and are suitable for long-term gamma-counting. These isotopes and the rest of the gases evolved in a NIF shot will be drawn through the NIF turbo pumps, past the temporarily shuttered cryo pumps (to aid our collection efficiency), and towards the first main portion of the RAGS system: the pre-cleaner. The pre-cleaner will consist of a water removal system, a series of heated getter cartridges to remove most other impurities such as N{sub 2}, O{sub 2}, CO{sub 2}, etc., and a residual gas analyzer (RGA) to monitor vacuum quality. The noble gases will flow through the precleaner and into the second stage of the system: the cryo collector. This cryo collector consists of a main cryo head for noble gas collection which will operate for approximately five minutes post-shot. Afterwards a valve will close and isolate the pre-cleaner, while the cryo head warms to release the Xe gas to one of two locations - either a second cryo station for in-situ gamma counting, or to a small cooled gas bottle for removal and counting. Additional capabilities of the RAGS system include a noble gas calibration apparatus attached to the NIF target chamber, which will be operated hours pre-shot to determine collection efficiency through the whole RAGS system via the signal detected from the RGA. Also it is possible there will be the addition of a helium puff system to drive the Xe through the pre-cleaner and collection stations. It is also likely that multiple cryo collection stations will be built into the system in the future to fractionate and collect other noble gases such as Kr, Ar, and possibly Ne. A prototype pre-cleaner has been built at Lawrence Berkeley National Laboratory (LBNL) and is in the testing phases. The information learned in this testing will help collaborators at Sandia National Laboratory that are building and delivering the systems that will be deployed at NIF. The LBNL testing so far has demonstrated that radioactive fission gases can be flowed through the system with and without carrier gases of air and/or He, and the activity can be collected on an activated charcoal sample. Further testing in the upcoming months will hopefully yield more information about any presence of Xe in the water removed from the system, and commissioning of a small cryo cooler as well.
In order to estimate the shale gas in place and the eventual recovery during shale gas operations, one of the key requirements is to accurately characterize the shale’s petrophysical and transport properties such as porosity, permeability, diffusivity, and storage capacity. Despite the many efforts reported in the technical literature aiming to provide an improved understanding of the complex pore structures and the associated fluid flow in gas shales, complete characterization of organic-rich shale samples still poses a big challenge. Here, we have characterized mass transfer and sorption in shale at different length scales using Helium (He) and Argon (Ar) as probe gases. Thermogravimetric analysis (TGA) with a shale cube of ~1 cm 3 in size and gas expansion experiments with a full-diameter core (3.5” in diameter) were used to measure sorption kinetics/isotherms and mass transfer, respectively. Both samples are from the same depth/location in the Marcellus shale formation. The TGA steady-state technique was initially used to generate excess sorption isotherms for Ar, while dynamic TGA experiments were used to study its sorption kinetics. The TGA experiments demonstrate that Ar, which has a similar sorption potential as Methane, but is generally assumed to be inert, adsorbs onto the surfaces of the mesoporous and microporous regions of the shale samples according to a Langmuir-type behavior. Helium expansion experiments, on the full-diameter core, were used to measure the overall porosity, on the basis that He is a non-sorbing and inert gas as compared to Ar. The He expansion experiments, furthermore, allow us to delineate the mass transfer of gas across the inherent hierarchy of pore sizes, including macropores (macro- and microcracks), mesopores and micropores. Similar expansion experiments were also performed with Ar to study the combined impact of mass transfer and sorption. A triple-porosity model (TPM) was utilized to interpret the He expansion experiments with the shale core and to extract (estimate) relevant transport parameters. We report and compare here the diffusivities and permeabilities of the whole core for both He and Ar, as calculated from the modeling and fitting of the experimental data. On the premise that the shale cube is representative of the matrix region of the core, the Ar sorption kinetics from the cube experiments were subsequently combined with the transport parameters extracted from the He experiments to predict the behavior of the Ar expansion test with the full-diameter core. An excellent agreement is observed between the model predictions and the experimental data. The experimental observations and their interpretation indicate that one must be cautious when using Ar to estimate the true porosity and permeability of shales. In addition, we demonstrate that He and Ar probe gases, when used in tandem, can be employed effectively as a tool to characterize shales in terms of mass transfer and sorption dynamics across scales.
In this article, we present the preparation and characterization of a large sample of implanted noble gas targets for use in precision nuclear astrophysics measurements with intense proton beams. Tantalum and titanium backings were prepared using wet-acid etching, outgassed via resistive heating, and implanted with 20 Ne + beams from differing ion sources. These experimental targets were investigated using both nuclear reaction analysis techniques on the 1169-keV resonance in 20 Ne(p, $\gamma$) 21 Na and Rutherford backscattering spectrometry analysis with 2-MeV α-particle beams. Results from these analyses reveal small target-to-target variations in stoichiometry, while exhibiting excellent agreement independent of ion-beam analysis method. We also present a self-consistent validation of the nuclear reaction analysis results using ion transport simulations in TRIM-2013 that rely on input parameters from SIMNRA scattering-yield fits to Rutherford backscattering spectra. In addition to a complete description of the implantation profile, this analysis method provides an alternate solution for characterizing a large sample of implanted targets when no suitable resonances are available for nuclear reaction analysis.
A system is provided for testing the hermeticity of a package, such as a microelectromechanical systems package containing a sealed gas volume, with a sampling device that has the capability to isolate the package and breach the gas seal connected to a pulse valve that can controllably transmit small volumes down to 2 nanoliters to a gas chamber for analysis using gas chromatography/mass spectroscopy diagnostics.
As demand increases for an affordable energy source that is tied to an environmental obligation to reduce greenhouse gas emissions and water usage, there is a growing consideration in shale production utilizing processes such as 1) enhancing hydrocarbon recovery via carbon dioxide (CO 2 ) flooding, 2) using CO 2 as a fracturing agent to minimize water use, and 3) storing CO 2 in depleted shale formations to mitigate emissions to the atmosphere. Understanding the geochemical reactions and alterations that occur as shale is exposed to fluids and CO 2 is necessary to develop and optimize each of these processes for field applications. While the majority of shale formations are stimulated using traditional fracturing fluid, some may be fractured using CO 2 or other non-traditional means. We examine the effect fracturing fluid has on shale and how it behaves with secondary exposure to dry CO 2 or CO 2 -saturated water using in situ Fourier Transform infrared spectroscopy (FTIR), feature relocation scanning electron microscopy (SEM), and surface area and pore size analysis using volumetric gas sorption. These techniques were performed on Eagle Ford and Barnett shale samples that were exposed to fracturing fluid and unexposed (as received). Shales that have been exposed to traditional fracturing fluid experienced two reaction fronts. The first reaction front was formed during exposure to the fracturing fluid (pH of ~1.4). A secondary reaction front was formed as a result of CO 2 -saturated fluid exposure in the form of carbonic acid (pH ~5.6). These two different reaction mechanisms drove multiple dissolution and precipitation cycles which altered petrophysical properties of the shale and could lead to a significant impact on flow pathways. FTIR showed that equilibration of carbonate dissolution and precipitation cycles could take as long as 35 days. Samples exposed to fracturing fluid showed significantly less carbonate reactivity compared to those exposed to water. Pore size analysis results indicate exposure to fracturing fluid blocked small nanopores (10-15 nm) reducing BET surface area and total pore volume. SEM results show barite precipitated heavily during exposure to fracturing fluid. It appeared that carbonic acid was able to extract sulfur from organic matter to form gypsum evaporites. The mineralogical (barite precipitation and calcite dissolution/precipitation) and pore-scale alterations observed in these samples may lead to enhancement of flow pathways for injected CO 2 or produced hydrocarbons.
We present an analysis of results on absorption from Ca II, Ca I, K I, and the molecules CH{sup +}, CH, C{sub 2}, and CN that probes gas interacting with the supernova remnant IC 443. The 11 directions sample material across the visible nebula and beyond its eastern edge. Most of the neutral material, including the diatomic molecules, is associated with the ambient cloud detected via H I and CO emission. Analysis of excitation and chemistry yields gas densities that are typical of diffuse molecular gas. The low-density gas probed by Ca II extends over a large range in velocities, from -120 to +80 km s{sup -1} in the most extreme cases. This gas is distributed among several velocity components, unlike the situation for the shocked molecular clumps, whose emission occurs over much the same range but as very broad features. The extent of the high-velocity absorption suggests a shock velocity of 100 km s{sup -1} for the expanding nebula.
The performance of two conceptually-simple uncertainty quantification techniques are tested against the rigorous nested-loop sampling technique of Roy and Oberkampf (Comput Methods Appl Mech Eng, 200: 2131–2144, 2011) (herein called full-sampling) using two very small-scale DEM-based models of particulate flow (one gas-solid flow and one granular flow). The first simplified forward uncertainty propagation technique, reduced-sampling, uses a sensitivity analysis to eliminate uncertain inputs that have little impact on the model output prior to nested-loop sampling. The second technique, boundary-sampling, uses a sensitivity analysis to inform the selection of two bounding cases for each key model output. In conclusion, the uncertainties in the model outputs obtained via the reduced- and boundary-sampling methods agree well with those from full-sampling for both the gas-solid and granular flow models while yielding computational savings of 65–75% (reduced sampling) and 94–97% (boundary sampling).
Whether or not among the myriad tiny protogalaxies there exists a population with similarities to present-day galaxies is an open question. We show, using BlueTides, the first hydrodynamic simulation large enough to resolve the relevant scales, that the first massive galaxies to form are predicted to have extensive rotationally supported disks. Although their morphology resembles in some ways Milky Way types seen at much lower redshifts, these high-redshift galaxies are smaller, denser, and richer in gas than their low-redshift counterparts. From a kinematic analysis of a statistical sample of 216 galaxies at redshift z = 8–10, we have found that disk galaxies make up 70% of the population of galaxies with stellar mass 10{sup 10}M{sub ⊙} or greater. Cold dark matter cosmology therefore makes specific predictions for the population of large galaxies 500 million years after the Big Bang. We argue that wide-field satellite telescopes (e.g., WFIRST) will in the near future discover these first massive disk galaxies. The simplicity of their structure and formation history should make new tests of cosmology possible.
Aromatic hydrocarbons are associated with direct adverse human health effects and can have negative impacts on ecosystems due to their toxicity, as well as indirect negative effects through the formation of tropospheric ozone and secondary organic aerosol that affect human health, crop production and regional climate. Measurements were conducted at the Welgegund measurement station (South Africa) that is considered to be a regionally representative background site. However, the site is occasionally impacted by plumes from major anthropogenic source regions in the interior of South Africa, which include the western Bushveld Igneous Complex (e.g. platinum, base metal and ferrochrome smelters), the eastern Bushveld Igneous Complex (platinum and ferrochrome smelters), the Johannesburg-Pretoria metropolitan conurbation (>10 million people), the Vaal Triangle (e.g. petrochemical and industries), the Mpumalanga Highveld (e.g. coal-fired power plants and petrochemical industry) and also a region of anti-cyclonic recirculation of air mass over the interior of South Africa. The aromatic hydrocarbon measurements were conducted with an automated sampler on Tenax-TA and Carbopack-B adsorbent tubes with heated inlet for one year. Samples were collected twice a week for two hours during daytime and two hours 1 during night-time. A thermal desorption unit, connected to a gas chromatograph and a mass 2 selective detector was used for sample preparation and analysis. Results indicated that the 3 monthly median total aromatic hydrocarbon concentrations ranged between 0.01 to 3.1 ppb. 4 Benzene levels did not exceed local air quality standards. Toluene was the most abundant 5 species, with an annual median concentration of 0.63 ppb. No statistically significant 6 differences in the concentrations measured during daytime and night-time were found and no distinct seasonal patterns were observed. Air mass back trajectory analysis proved that the lack of seasonal cycles could be attributed to patterns determining the origin of the air masses sampled. Aromatic hydrocarbon concentrations were in general significantly higher in air masses that passed over anthropocentrically impacted regions. Interspecies correlations and ratios gave some indications of the possible sources for the different aromatic hydrocarbons in the source regions defined in the paper. The highest contribution of aromatic hydrocarbon concentrations to ozone formation potential was also observed in plumes passing over anthropocentrically impacted regions.
Optical spectrometer apparatus, systems, and methods for analysis of carbon-14 including a resonant optical cavity configured to accept a sample gas including carbon-14, an optical source configured to deliver optical radiation to the resonant optical cavity, an optical detector configured to detect optical radiation emitted from the resonant cavity and to provide a detector signal; and a processor configured to compute a carbon-14 concentration from the detector signal, wherein computing the carbon-14 concentration from the detector signal includes fitting a spectroscopic model to a measured spectrogram, wherein the spectroscopic model accounts for contributions from one or more interfering species that spectroscopically interfere with carbon-14.