Learning effective stochastic differential equations from microscopic simulations: Linking stochastic numerics to deep learning

We identify effective stochastic differential equations (SDEs) for coarse observables of fine-grained particle- or agent-based simulations; these SDEs then provide useful coarse surrogate models of the fine scale dynamics. We approximate the drift and diffusivity functions in these effective SDEs through neural networks, which can be thought of as effective stochastic ResNets. The loss function is inspired by, and embodies, the structure of established stochastic numerical integrators (here, Euler–Maruyama and Milstein); our approximations can thus benefit from backward error analysis of these underlying numerical schemes. They also lend themselves naturally to “physics-informed” gray-box identification when approximate coarse models, such as mean field equations, are available. Existing numerical integration schemes for Langevin-type equations and for stochastic partial differential equations can also be used for training; we demonstrate this on a stochastically forced oscillator and the stochastic wave equation. Our approach does not require long trajectories, works on scattered snapshot data, and is designed to naturally handle different time steps per snapshot. We consider both the case where the coarse collective observables are known in advance, as well as the case where they must be found in a data-driven manner.

97 MATHEMATICS AND COMPUTING↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI{sub 100} as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI{sub 100} is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, {sigma}. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI{sub 100} calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good agreement between the measured dose profile data and the fitted Gaussian functions. The solid-state detector had no energy dependence--within the energy range of interest--and the analytical model succeeded in reproducing the absolute dose values obtained with the pencil ion chamber. For the case of large cone-beam single axial scans, the quantity that better characterizes the total energy imparted to the patient is the weighted dose profile integral (DPI{sub w}). The DPI{sub w} can be easily determined from the two parameters that define the Gaussian functions: f(0) and {sigma}. The authors found that the DLP underestimated the total energy imparted to the patient by more than 20%. The authors also found that the calculated CT dosimetric quantities were higher than those displayed on the scanner console. Conclusions: The authors described and validated a method to assess radiation dose in large cone-beam single axial scans. This method offers a simple and more accurate estimation of the total energy imparted to the patient, thus offering the possibility to update the bridge between CT dosimetry and the estimation of the effective dose for cone-beam CT examinations in radiology, nuclear medicine, and radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗