Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT REGULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Collaborative Research: Unveiling the Interplay Between Magnetic Reconnection and Turbulence — Theory and Modeling

This is the final technical report for the project "Collaborative Research: Unveiling the Interplay Between Magnetic Reconnection and Turbulence — Theory and Modeling." This project investigated the interplay between two fundamental plasma processes — turbulence and magnetic reconnection — and the associated heating and particle acceleration. In particular, we focused on a new regime where the plasmoid instability mediates the turbulent energy cascade. In this new regime, reconnecting current sheets are disrupted by the growth of plasmoids/flux ropes on time scales shorter than the typical turnover times of eddies, speeding up the energy cascade and steepening the turbulence energy spectrum. This project addressed the following outstanding open questions: (1) What are the fundamental differences between plasmoid‐mediated turbulence cascade in three dimensions (3D) and two dimensions (2D)? (2) What are the essential features of plasmoid‐mediated turbulence in weakly collisional or collisionless regimes beyond resistive MHD? (3) How does the interplay of turbulence and reconnection regulate the energy release and dissipation in space and astrophysical plasmas? To address these questions, we have carried out three investigations: (1) Three-dimensional plasmoid-mediated turbulence energy cascade; (2) plasmoid-mediated reconnection and turbulence in three-dimensional Hall MHD; (3) reconnection and heating in coronal loops. This technical report summarizes the key findings of these investigations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A review of regulatory standard test methods for residential wood heaters and recommendations for their advancement

In many regions, residential wood heaters are a leading source of harmful air pollution but only satisfy a small portion of local heating demands. In response, standardized laboratory test methods have been developed to characterize and limit wood heater emissions. While these test methods are a key tool for advancing both wood heater technology and environmental regulations, many of the experimental procedures are outdated and provide few actionable insights for improving heater performance. Furthermore, these test methods vary widely around the world and may not adequately capture the performance of wood heaters operating in residences. This study presents a comprehensive review of standardized wood heater test methods to identify fundamental experimental objectives and regulated performance metrics. Using the results of this review, recommendations are provided to make the test methods more accessible and representative of residential performance, while generating actionable data to motivate heater design improvements. This study elucidates the current state of standard test methods, and the developments needed to advance clean wood heater technologies and public policies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shape‐Stabilization of Phase Change Materials with Carbon‐Conscious Poly(hydroxy)Urethane Foams

Thermal energy regulation is a significant challenge, contributing to over 30% of annual greenhouse gas emission (GHG) emissions. Phase change materials (PCMs) offer a promising solution by storing thermal energy, which can enable the reuse of waste heat for heating and cooling; however, developing materials for shape-stabilized PCMs remains crucial. This work investigates a self-foaming poly(hydroxy)urethane (PHU), derived from a non-isocyanate polyurethane (NIPU), as a porous support for shape-stabilizing paraffinic and salt hydrate PCMs. PHU-encapsulated paraffinic PCMs exhibited excellent thermal stability over repeated cycles. Thermal stability with salt hydrate PCMs, specifically calcium chloride hexahydrate (CaCl 2 •6H 2 O), is achieved by the incorporation of 5 wt.% barium carbonate (BaCO 3 ) into the PHU foam. This enabled stable cycling for over 48 cycles with desirable thermal properties, i.e., a melting point ≈30 °C, high enthalpy (ca. 138 J g −1 per cycle), and a consistent freezing point ≈20 °C, making it suitable for applications in buildings and electric vehicle battery insulation. Also, incorporating graphite (1.5–10 wt.%) into the foam enhanced the thermal conductivity of shape-stabilized CaCl 2 •6H 2 O during heating and cooling cycles. Overall, the approach detailed here offers a carbon-conscious and chemically tunable material for thermal energy storage.

25 ENERGY STORAGE↗

Hardware-Based Demonstration of Temperature Control Functions for Reactor Systems

Establishing autonomy in reactor control systems has become essential for the expansion of nuclear technologies. Thermal regulation in particular remains crucial for maintaining stable operation and ensuring the integrity of fuel. To alleviate public skepticism of the safety of nuclear reactors, demonstrating control over this key factor is pivotal. Utilizing electric heat pads to simulate the heat released in a reactor core, thermocouples for temperature monitoring, and an Arduino micro programmable logic controller (PLC) for control, a hardware-based demonstration of a reactor heating system validates the efficacy of reactor control over this key parameter. To improve precision, a proportional-integral-derivative (PID) algorithm was implemented in the heating control loop to ensure meticulous control of reactor functions. In addition, the integration of this physical system with a digital simulator tool such as RELAP5-3D establishes a foundation for a comprehensive testing environment. This allows for a refinement of temperature control under various simulated reactor conditions, bringing another layer of reliability to the operation of the system. By facilitating a physical demonstration of reactor thermal management and control strategies, this project provides a foundation for expanded testing and educational outreach. Ultimately, this system advances the broader goal of demonstrating the safety and viability of autonomous reactor operations, contributing to public trust and future reactor deployment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Divertor-safe nonlinear burn control based on a SOLPS parameterized core-edge model for ITER

Abstract For ITER operations, the range of desirable burning-plasma regimes with high fusion power output will be restricted by various operational constraints. These constraints include the saturation of ITER’s various heating and fueling actuators such as the neutral beam injectors, the ion and electron cyclotron heating systems, the gas puffing system, and the deuterium–tritium pellet injectors. In addition to these actuator constraints, the H-mode power threshold, divertor detachment, and the heat load on the divertor targets may apply limitations to ITER’s operational space. In this work, Plasma Operation Contour (POPCON) plots that map the aforementioned constraints to the temperature-density space are used to investigate which constraints are most limiting towards accessing regimes with high fusion power output. The presented POPCON plots are based on a control-oriented core-edge model that couples the nonlinear density and energy response models for the core-plasma region with SOLPS4.3 parameterizations for conditions in the edge-plasma regions (scrape-off-layer and divertor). Using this control-oriented core-edge model, a nonlinear burn controller, which aims to regulate the plasma temperature and density in the core-plasma region, is constructed in this work. This controller is augmented with an online optimization scheme that governs the control references such that the plasma can be guided towards regimes with high fusion powers while protecting the divertor targets from dangerously high heat loads. A closed-loop simulation study illustrates the capability of this burn control scheme.

Physics↗

The Adaptive Potential of the Middle Domain of Yeast Hsp90

Abstract The distribution of fitness effects (DFEs) of new mutations across different environments quantifies the potential for adaptation in a given environment and its cost in others. So far, results regarding the cost of adaptation across environments have been mixed, and most studies have sampled random mutations across different genes. Here, we quantify systematically how costs of adaptation vary along a large stretch of protein sequence by studying the distribution of fitness effects of the same ≈2,300 amino-acid changing mutations obtained from deep mutational scanning of 119 amino acids in the middle domain of the heat shock protein Hsp90 in five environments. This region is known to be important for client binding, stabilization of the Hsp90 dimer, stabilization of the N-terminal-Middle and Middle-C-terminal interdomains, and regulation of ATPase–chaperone activity. Interestingly, we find that fitness correlates well across diverse stressful environments, with the exception of one environment, diamide. Consistent with this result, we find little cost of adaptation; on average only one in seven beneficial mutations is deleterious in another environment. We identify a hotspot of beneficial mutations in a region of the protein that is located within an allosteric center. The identified protein regions that are enriched in beneficial, deleterious, and costly mutations coincide with residues that are involved in the stabilization of Hsp90 interdomains and stabilization of client-binding interfaces, or residues that are involved in ATPase–chaperone activity of Hsp90. Thus, our study yields information regarding the role and adaptive potential of a protein sequence that complements and extends known structural information.

Cote-Hammarlof, Pamela A.↗

Project Presentation: Hardware-Based Demonstration of Temperature Control Functions for Reactor Systems

Autonomous thermal regulation in nuclear reactors remains crucial for maintaining stable operation and ensuring the integrity of fuel. To alleviate public skepticism of the safety of nuclear reactors, demonstrating control over this key factor is pivotal. Utilizing electric heat pads to simulate the heat released in a reactor core, thermocouples for temperature monitoring, and an Arduino micro programmable logic controller (PLC) with an embedded proportional-integral-derivative (PID) algorithm for control, a hardware-based demonstration of a reactor heating system will validate the efficacy of reactor control over this key parameter. This report covers internship project presentation as well as relevant experience with nuclear and proposal for project upgrade.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Poster: Hardware-Based Demonstration of Temperature Control Functions for Reactor Systems

Autonomous thermal regulation in nuclear reactors remains crucial for maintaining stable operation and ensuring the integrity of fuel. To alleviate public skepticism of the safety of nuclear reactors, demonstrating control over this key factor is pivotal. Utilizing electric heat pads to simulate the heat released in a reactor core, thermocouples for temperature monitoring, and an Arduino micro programmable logic controller (PLC) with an embedded proportional-integral-derivative (PID) algorithm for control, a hardware-based demonstration of a reactor heating system will validate the efficacy of reactor control over this key parameter.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Effect of Wettability Gradient on the Scale Formation in Falling Film Flow

Mitigation of scale formation and performance degradation remains a vital challenge for falling film evaporators in various industries. In this work, an experimental study of falling film flow on a horizontal tube is conducted to investigate the effects of wettability gradients on thermal, hydraulic, and fouling behavior. It is revealed that certain hydrophobic coating patterns, such as strip, ring, and grid patterns, lead to unwetted heat transfer area, which results in decreased heat transfer compared to fully wetted plain tube. By adjusting the geometry and position of the wettability gradient, the hybrid coating demonstrates improved heat transfer performance. Based on the characteristics of horizontal tube falling film flow, impinging jet, thin film flow, and liquid retention at the tube bottom, a hybrid coating pattern is developed to improve surface wetting and mitigate the scaling coverage. It is revealed that scale deposition is regulated by wettability gradient. Crystals tend to be dense and compact in hydrophilic areas, while they appear scattered or even absent in hydrophobic regions, depending on the dimension of the hydrophobic area. While at the hydrophilic/hydrophobic boundary, a noticeable scale thickness step is observed, which raises the potential for self-cleaning. Furthermore, the balance of minimization of scaling layer coverage and maximization of wetting area requires an optimal design in coating dimensions, for which a systemic study of both flow dynamics and fouling characteristics on the falling film is necessary in the future.

42 ENGINEERING↗

Nonlinearity of the post-spinel transition and its expression in slabs and plumes worldwide

Phase transitions in the mantle control its internal dynamics and structure. The post-spinel transition marks the upper–lower mantle boundary, where ringwoodite dissociates into bridgmanite plus ferropericlase, and its Clapeyron slope regulates mantle flow across it. This interaction has previously been assumed to have no lateral spatial variations, based on the assumption of a linear post-spinel boundary in pressure and temperature. Here we present laser-heated diamond anvil cell experiments with synchrotron X-ray diffraction to better constrain this boundary, especially at higher temperatures. Combining our data with results from the literature, and using a global analysis based on machine learning, we find a pronounced nonlinearity in the post-spinel boundary, with its slope ranging from –4 MPa/K at 2100 K, to –2 MPa/K at 1950 K, and to 0 MPa/K at 1600 K. Changes in temperature over time and space can therefore cause the post-spinel transition to have variable effects on mantle convection and the movement of subducting slabs and upwelling plumes.

58 GEOSCIENCES↗

Unlocking load growth at the grid edge: Practices for managing, recovering, and allocating distribution system investments

Utilities and utility regulators are preparing to make significant investments in the electricity distribution system driven by expected load growth in coming years and decades. Regulators will be tasked with vetting investment proposals and implementing cost recovery and allocation mechanisms. In particular, state regulators are anticipating the need to make proactive distribution system investments, building the capability to serve new load in advance of demand. This report focuses on load growth from homes and businesses that adopt electric vehicles and heat pump heating technologies. Through a review of legislation and regulatory dockets in a subset of states, we provide insights into emerging utility and regulatory practices to recover and allocate costs of electrification-driven distribution system investments necessary to accommodate these technologies. Our review focused on utility electrification programs, line extension policies, and proactive investments. Our report is largely descriptive, offering detailed information about approaches different state commissions and utilities have implemented to inform future decision-making.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mastering morphology of non-fullerene acceptors towards long-term stable organic solar cells

Despite the rapid progress of organic solar cells based on non-fullerene acceptors, simultaneously achieving high power conversion efficiency and long-term stability for commercialization requires sustainable research effort. Here, we demonstrate stable devices by integrating a wide bandgap electron-donating polymer (namely PTzBI-dF) and two acceptors (namely L8BO and Y6) that feature similar structures yet different thermal and morphological properties. The organic solar cell based on PTzBI-dF:L8BO:Y6 could achieve a promising efficiency of 18.26% in the conventional device structure. In the inverted structure, excellent long-term thermal stability over 1400 h under 85 °C continuous heating is obtained. The improved performance can be ascribed to suppressed charge recombination along with appropriate charge transport. We find that the morphological features in terms of crystalline coherence length of fresh and aged films can be gradually regulated by the weight ratio of L8BO:Y6. Additionally, the occurrence of melting point decrease and reduced enthalpy in PTzBI-dF:L8BO:Y6 films could prohibit the amorphous phase to cluster, and consequently overcome the energetic traps accumulation aroused by thermal stress, which is a critical issue in high efficiency non-fullerene acceptors-based devices. This work provides insight into understanding non-fullerene acceptors-based organic solar cells for improved efficiency and stability.

14 SOLAR ENERGY↗

Production efficiencies of sound waves in the intracluster medium driven by AGN jets

Feedback from active galactic nuclei (AGNs) is believed to be the most promising solution to the cooling flow problem in cool-core clusters. Dissipation of sound waves is considered as one of the possible heating mechanisms; however, its relative contribution to heating remains unclear. To estimate the energy budget for heating, we perform 3D hydrodynamic simulations of AGN jet injections in a Perseus-like cluster and quantify the amount of energy stored in the forms of weak shocks and waves. For this work, e find that, for a single jet injection with typical parameters in cool-core clusters, ${\sim}9{{\ \rm per\ cent}}$ of the total jet energy is stored in compressional waves (including both shocks and waves). However, due to the destructive effects among randomly phased waves as well as the dissipation of shock energies, in our simulations including self-regulated AGN feedback, no more than $3{{\ \rm per\ cent}}$ of the total injected energy goes into compressional waves. We further separate the energy contribution from shocks and waves and find that, for a single outburst, the shocks can only contribute to ${\sim}20{-}30{{\ \rm per\ cent}}$ of the total compressional energy in the inner radii and quickly dissipate away. In the self-regulated case where shocks are repeatedly generated, shocks completely dominate over sound waves in the inner region and can still provide ${\sim}40{-}50{{\ \rm per\ cent}}$ of the total compressional energy at outer radii. Our results suggest that the production of sound waves is not as efficient as what was previously found, and thus sound wave dissipation may be a subdominant source of heating in cool-core clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unraveling the Hsp70-ROS-autophagy axis in pentachlorophenol-challenged lung and liver epithelial cells

Pentachlorophenol (PCP) was extensively utilized as an organochlorine pesticide and wood preservative in the United States from the 1930s until the Environmental Protection Agency (EPA) imposed restrictions due to concerns about its toxicity and potential carcinogenic properties. Although it is no longer widely used, PCP remains a concern due to its environmental persistence and potential for long-term health effects. Significant occupational and environmental exposures have likely occurred, with the health and economic costs of PCP exposure potentially being substantial given its known toxicity. Notably, PCP exhibits rapid absorption through both the skin and respiratory system and has been shown to cause hepatotoxicity, developmental toxicity, immunotoxicity, irritation, and carcinogenicity in laboratory animal studies. PCP exposure induces oxidative stress, a key mechanism underlying its inflammatory and toxic effects, which can activate cellular stress responses including upregulation of heat shock protein 70 (Hsp70). Previous studies in lung and liver epithelial cells have shown that Hsp70 and oxidative stress play pivotal roles in triggering autophagy. This study establishes the critical role of the Hsp70-reactive oxygen species (ROS)-autophagy axis in regulating cellular responses to PCP exposure in human alveolar (A549) and liver carcinoma (HepG2) epithelial cells. Our research elucidated the molecular mechanisms underlying PCP's cellular effects, demonstrating that its exposure resulted in increased expression of autophagy-related proteins (Beclin-1, LC3B, ATG12, and ATG16), subunits of NADPH oxidase (NCF-1, NCF-2, NOX2, and Rac), and antioxidant proteins (SOD and GPx) in both lung and liver cell types. Notably, PCP augmented the interaction between Hsp70 and the autophagy regulator Beclin-1. Pretreatment with the ROS inhibitor N-acetylcysteine or Hsp70 knockdown markedly reversed PCP-induced responses. Our in-silico protein–protein docking analysis and molecular dynamics simulation studies revealed enhanced interactions and/or stable confirmations maintained throughout the simulations for TLR4-Hsp70 and Hsp70-Beclin-1 complexes in the presence of PCP. These findings provide a strong foundation for future studies, employing in vivo experimental models and human populations to identify promising targets for PCP-induced toxicity and cellular injury. As a result, these findings may have far-reaching implications for public health and environmental policy, ultimately leading to the identification of biomarkers and the development of more effective interventions for environmentally induced toxicity and diseases.

97 MATHEMATICS AND COMPUTING↗

Model Validation and Uncertainty Quantification on the KRUSTY Microreactor Design Using GRIFFIN Neutron Transport Code [Poster]

Argonne National Laboratory (ANL) and INL have developed a GRIFFIN steady state neutronics model for the multiphysics simulations of the Kilopower Reactor Using Sterling TechnologY (KRUSTY) microreactor in the Multiphysics Object Oriented Simulation Environment (MOOSE). The reliability of such deterministic neutronics models can be validated by comparing with computations from Monte Carlo codes (e.g. MCNP, SERPENT, OpenMC, Shift, etc). Furthermore, potential modeling/design improvements can be identified by incorporating uncertainty quantification (UQ), which can be performed by MOOSE’s Stochastic Tools Module (STM). KRUSTY is a prototype for a 5-kW thermal nuclear-powered space reactor. Its primary components consist of nuclear fuel, heat pipes, a control rod, a reflector, and the shielding. The fuel consists of 3 stacked U-7.65Mo cylinders with a hole in the center for the control rod. 8 liquid sodium heat pipes transfer fission energy from the solid fuel block to the Sterling power conversion system where the energy is extracted, and the cooled sodium flows back to the core via capillary action . The movable Boron Carbide control rod regulates the neutron population during startup or when a reactor temperature boost is needed . The beryllium oxide reflector is in 3 places in the reactor; it surrounds the core axially, it lies beneath the core on a platen, and it is present in the shim. The axial and lower reflectors rest on an adjustable stainless-steel platen that moves upward to cover the fuel and help the reactor reach criticality. Lastly, radial stainless steel surrounds the core offering protection from radiation exposure .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY25 Report on Water NSTF Testing: Parametric and Accident Testing with Lower Tank Inlet

The Natural Convection Shutdown Heat Removal Test Facility (NSTF) at Argonne National Laboratory has continued to generate empirical validation data on the performance of water-based reactor cavity cooling system (RCCS) for seven years. This data is actively being used to support the development of passive decay heat removal systems for advanced reactors. Distinguishing this facility are 1) the large, ½ scale of the facility and 2) its governance under an NQA-1 qualified program for producing data of the highest pedigree for advanced reactor designers and regulators. In addition to the experimental activities discussed in this report, a computational modeling program continues to support the experimental program and further accuracy and understanding of the computational models. Together, the experimental and computational work create a mutually beneficial relationship integral to the overall program objective of advancing the understanding of the RCCS technology.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗