Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEMODYNAMIC RESPONSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

193 records · Page 11

Use-dependent loss of active sympathetic neurogenic vasodilation after nitric oxide synthase inhibition in conscious rats. Evidence for the presence of preformed stores of nitric oxide-containing factors

In this study, we examined whether air-jet stress-induced active sympathetic hindlimb vasodilation in conscious rats involves the release of preformed stores of nitric oxide-containing factors. We determined the effects of repeated episodes of air-jet stress (six episodes given 5 minutes apart) on mean arterial pressure and vascular resistances in the mesenteric bed and intact and sympathetically denervated hindlimb beds of conscious rats treated with saline or the nitric oxide synthesis inhibitor N omega-nitro-L-arginine methyl ester (L-NAME, 25 mumol/kg IV). In saline-treated rats, air-jet stress produced alerting behavior, minor changes in blood pressure, pronounced mesenteric vaso-constriction, and immediate and marked vasodilation in the sympathetically intact hindlimb but a minor vasodilation in the sympathetically denervated hindlimb. Each air-jet stress produced virtually identical responses. In L-NAME-treated rats, the first air-jet stress produced vasodilator responses in the sympathetically intact and sympathetically denervated hindlimbs that were similar to those in the saline-treated rats. However, each subsequent air-jet stress produced progressively smaller vasodilator responses in the sympathetically intact but not the sympathetically denervated hindlimb. There was no loss of air-jet stress-induced alerting behavior or mesenteric vasoconstriction, suggesting that L-NAME did not interfere with the central processing of the air-jet or the resultant changes in autonomic nerve activity. The progressive diminution of air-jet stress-induced vasodilation in the intact hindlimb of L-NAME-treated rats may be due to the use-dependent depletion of preformed stores of nitric oxide-containing factors that cannot be replenished in the absence of nitric oxide synthesis.

NASA Discipline Regulatory Physiology↗

A computational model-based validation of Guyton's analysis of cardiac output and venous return curves

Guyton developed a popular approach for understanding the factors responsible for cardiac output (CO) regulation in which 1) the heart-lung unit and systemic circulation are independently characterized via CO and venous return (VR) curves, and 2) average CO and right atrial pressure (RAP) of the intact circulation are predicted by graphically intersecting the curves. However, this approach is virtually impossible to verify experimentally. We theoretically evaluated the approach with respect to a nonlinear, computational model of the pulsatile heart and circulation. We developed two sets of open circulation models to generate CO and VR curves, differing by the manner in which average RAP was varied. One set applied constant RAPs, while the other set applied pulsatile RAPs. Accurate prediction of intact, average CO and RAP was achieved only by intersecting the CO and VR curves generated with pulsatile RAPs because of the pulsatility and nonlinearity (e.g., systemic venous collapse) of the intact model. The CO and VR curves generated with pulsatile RAPs were also practically independent. This theoretical study therefore supports the validity of Guyton's graphical analysis.

NASA Discipline Cardiopulmonary↗

Right Ventricular Tissue Doppler Assessment in Space During Circulating Volume Modification using the Braslet-M Device

This joint U.S. - Russian work aims to establish a methodology for assessing cardiac function in microgravity in association with manipulation of central circulating volume. Russian Braslet-M occlusion cuffs were used to temporarily increase the volume of blood in the lower extremities, which effectively reduces the volume returning to the heart in the central circulation. A novel methodology was tested on the International Space Station (ISS) to assess the volume status of crewmembers by evaluating the responses to application and release of the Braslet-on-occlusion cuffs, as well as to modified Valsalva and Mueller maneuvers. Baseline echocardiographic tissue Doppler imaging (TDI) of the right ventricular free wall with no Braslet applied shows early diastolic E' (16 cm/sec), late diastolic A' (14 cm/sec), and systolic (12 cm/sec) velocities compatible with normal subjects on Earth. TDI of the RV free wall with Braslet applied shows that early diastolic E' decreased by 50% (8 cm/sec), late diastolic A' increased by 45%, and systolic S' remains unchanged. TDI of the RV free wall approximately 8 beats after the Braslet was released shows early diastolic E' (8 cm/sec), late diastolic A' (12 cm/sec), and systolic S' (13 cm/sec) velocities. During this portion of the release, early diastolic E' did not recover to baseline values but late diastolic A' and systolic S' recovered to pre-Braslet values. The pre-systolic cross-sectional area of the internal jugular vein with Braslet off was 1.07 cm(sup 2) and 1.13 cm(sup 2) 10 min after the Braslet was applied. The presystolic cross-sectional area of the common femoral vein with Braslet off was 0.50 cm(sup 2), and was 0.54 cm(sup 2) 10 min after the Braslet was applied. The right ventricular myocardial performance Tei index also was calculated for comparison with typical values found in healthy subjects on Earth. Baseline and Braslet-on values for Tei index were 0.25 and 0.22 respectively. Braslet Tei indices are within normal ranges found in healthy subjects and temporarily become greater than 0.4 during the dynamic Braslet release portion of this study. Tissue Doppler imaging of the right ventricle revealed that the Braslet influenced cardiac preload and that fluid was sequestered in the lower-extremity interstitial and vascular space after only 10 minutes of application. This report demonstrates that Braslet application affects right ventricular physiology in long-duration space flight based on TDI and that this effect is in part due to venous hemodynamics.

Hamilton, D. R.↗

Insight into mechanisms of reduced orthostatic performance after exposure to microgravity: comparison of ground-based and space flight data

Since the beginning of human spaceflight, the value of understanding mechanisms of physiological adaptation to microgravity became apparent to life scientists who were interested in maintining crew health and developing countermeasures agains adverse effects of the mission. However, several characteristics associated the the logistics of spaceflight presented significant limitations to the scientific study of human adaptation to microgravity. Because space missions are so infrequent and involve minimal numbers of crewmembers, meaninful statistical analysis of data are limited. Reproducibility of results from spaceflight experiments is difficult to assess since there are few repeated space missions involving the same crewmembers. Since the emphasis of space missions is placed on operations, experiments are compromised without adequate control over various factors (e.g., time, diet, physical activities, etc.) that can impact measured responses. With the mimimal opportunity to collect spaceflight data, there is a high risk of experiments that simultaneously interfere with other experiments by the increasing demand on the crewmembers to participate in mumerous experiments proposed by multiple investigators. The technology and ability to measure physiological functions necessary to test specific hypotheses can be severely limited by physical space and power constraints of the space enviroment. Finally, technical and logistical aspects of space missions such as launch delays, extended missions, and inflight operational emergencies can significantly compromise the timing and control of experiments. These limitations have stimulated scientists to develop ground-based analogs of microgravity in an effort to investigate the effects of spaceflight on physiological function in a controlled experimental setting. The purpose of this paper is to provide a selected comparison of data collected from ground-based experiments with those obtained from spaceflight in an effort to assess the adequacy of ground analogs of actual flight for the study of human physiological adaptation to microgravity. Specifically, results from ground and spaceflight will be used to provide insight into mechanisms underlying adaptations of blood pressure regulation and reduced orthostatic performance to the microgravity environment.

Non-NASA Center↗

Mechanisms of alpha 1-adrenergic vascular desensitization in conscious dogs

To investigate the mechanisms of alpha 1-adrenergic vascular desensitization, osmotic minipumps containing either saline (n = 9) or amidephrine mesylate (AMD) (n = 9), a selective alpha 1-adrenergic receptor agonist, were implanted subcutaneously in dogs with chronically implanted arterial and right atrial pressure catheters and aortic flow probes. After chronic alpha 1-adrenergic receptor stimulation, significant physiological desensitization to acute AMD challenges was observed, i.e., pressor and vasoconstrictor responses to the alpha 1-adrenergic agonist were significantly depressed (p < 0.01) compared with responses in the same dogs studied in the conscious state before pump implantation. However, physiological desensitization to acute challenges of the neurotransmitter norepinephrine (NE) (0.1 micrograms/kg per minute) in the presence of beta-adrenergic receptor blockade was not observed for either mean arterial pressure (MAP) (30 +/- 7 versus 28 +/- 5 mm Hg) or total peripheral resistance (TPR) (29.8 +/- 4.9 versus 28.9 +/- 7.3 mm Hg/l per minute). In the presence of beta-adrenergic receptor plus ganglionic blockade after AMD pump implantation, physiological desensitization to NE was unmasked since the control responses to NE (0.1 micrograms/kg per minute) before the AMD pumps were now greater (p < 0.01) than after chronic AMD administration for both MAP (66 +/- 5 versus 32 +/- 2 mm Hg) and TPR (42.6 +/- 10.3 versus 23.9 +/- 4.4 mm Hg/l per minute). In the presence of beta-adrenergic receptor, ganglionic, plus NE-uptake blockade after AMD pump implantation, desensitization was even more apparent, since NE (0.1 micrograms/kg per minute) induced even greater differences in MAP (33 +/- 5 versus 109 +/- 6 mm Hg) and TPR (28.1 +/- 1.8 versus 111.8 +/- 14.7 mm Hg/l per minute). The maximal force of contraction induced by NE in the presence or absence of endothelium was significantly decreased (p < 0.05) in vitro in mesenteric artery rings from AMD pump dogs compared with saline control dogs. Furthermore, alpha 1-adrenergic receptor density, as determined by [3H]prazosin binding in membrane preparations from vessels in the mesentery, was decreased (8.2 +/- 1.0 versus 18.4 +/- 1.4 fmol/mg protein, p < 0.001) without any change in Kd in the AMD pump dogs compared with the saline pump dogs.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

'Non-hypotensive' hypovolaemia reduces ascending aortic dimensions in humans

1. The notion that small, 'non-hypotensive' reductions of effective blood volume alter neither arterial pressure nor arterial baroreceptor activity is pervasive in the experimental literature. We tested two hypotheses: (a) that minute arterial pressure and cardiac autonomic outflow changes during hypovolaemia induced by lower body suction in humans are masked by alterations in breathing, and (b) that evidence for arterial baroreflex engagement might be obtained from measurements of thoracic aorta dimensions. 2. In two studies, responses to graded lower body suction at 0 (control), 5, 10, 15, 20 and 40 mmHg were examined in twelve and ten healthy young men, respectively. In the first, arterial pressure (photoplethysmograph), R-R interval, and respiratory sinus arrhythmia amplitude (complex demodulation) were measured during uncontrolled and controlled breathing (constant breathing frequency and tidal volume). In the second, cross-sectional areas of the ascending thoracic aorta were calculated from nuclear magnetic resonance images. 3. Lower body suction with controlled breathing resulted in an increased arterial pulse pressure at mild levels (5-20 mmHg; ANOVA, P < 0.05) and a decreased arterial pulse pressure at moderate levels (40 mmHg; ANOVA, P < 0.05). Both R-R intervals and respiratory sinus arrhythmia were negatively related to lower body suction level, whether group averages (general linear regression, r > 0.92) or individual subjects (orthogonal polynomials, 12 of 12 subjects) were assessed. 4. Aortic pulse area decreased progressively and significantly during mild lower body suction, with 47% of the total decline occurring by 5 mmHg. 5. These results suggest that small reductions of effective blood volume reduce aortic baroreceptive areas and trigger haemodynamic adjustments which are so efficient that alterations in arterial pressure escape detection by conventional means.

NASA Discipline Cardiopulmonary↗

Evaluation of transit-time and electromagnetic flow measurement in a chronically instrumented nonhuman primate model

The Physiology Research Branch at Brooks AFB conducts both human and nonhuman primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to identify the particular mechanisms that invoke these responses. Primary investigative efforts in our nonhuman primate model require the determination of total peripheral resistance, systemic arterial compliance, and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. This study evaluated accuracy, linearity, biocompatability, and anatomical features of commercially available electromagnetic (EMF) and transit-time flow measurement techniques. Five rhesus monkeys were instrumented with either EMF (3 subjects) or transit-time (2 subjects) flow sensors encircling the proximal ascending aorta. Cardiac outputs computed from these transducers taken over ranges of 0.5 to 2.0 L/min were compared to values obtained using thermodilution. In vivo experiments demonstrated that the EMF probe produced an average error of 15% (r = .896) and 8.6% average linearity per reading, and the transit-time flow probe produced an average error of 6% (r = .955) and 5.3% average linearity per reading. Postoperative performance and biocompatability of the probes were maintained throughout the study. The transit-time sensors provided the advantages of greater accuracy, smaller size, and lighter weight than the EMF probes. In conclusion, the characteristic features and performance of the transit-time sensors were superior to those of the EMF sensors in this study.

Non-NASA Center↗

Hindlimb unweighting affects rat vascular capacitance function

Microgravity is associated with an impaired stroke volume and, therefore, cardiac output response to orthostatic stress. We hypothesized that a decreased venous filling pressure due to increased venous compliance may be an important contributing factor in this response. We used a constant flow, constant right atrial pressure cardiopulmonary bypass procedure to measure total systemic vascular compliance (C(T)), arterial compliance (C(A)), and venous compliance (C(V)) in seven control and seven 21-day hindlimb unweighted (HLU) rats. These compliance values were calculated under baseline conditions and during an infusion of 0.2 microg*kg(-1)*min(-1) norepinephrine (NE). The change in reservoir volume, which reflects changes in unstressed vascular volume (DeltaV(0)) that occurred upon infusion of NE, was also measured. C(T) and C(V) were larger in HLU rats both at baseline and during the NE infusion (P < 0.05). Infusion of NE decreased C(T) and C(V) by ~20% in both HLU and control rats (P < 0.01). C(A) was also significantly decreased in both groups of rats by NE (P < 0.01), but values of C(A) were similar between HLU and control rats both at baseline and during the NE infusion. Additionally, the NE-induced DeltaV(0) was attenuated by 53% in HLU rats compared with control rats (P < 0.05). The larger C(V) and attenuated DeltaV(0) in HLU rats could contribute to a decreased filling pressure during orthostasis and thus may partially underlie the mechanism leading to the exaggerated fall in stroke volume and cardiac output seen in astronauts during an orthostatic stress after exposure to microgravity.

NASA Discipline Cardiopulmonary↗

Augmented catecholamine uptake by the heart during hemorrhage in the conscious dog

Changes in arterial and coronary sinus concentrations of norepinephrine (NE) and epinephrine (E) in response to hemorrhage were examined in conscious dogs. Hemorrhage (45 +/- 3.2 ml/kg) decreased mean arterial pressure by 47 +/- 6%, left ventricular (LV) dP/dt by 38 +/- 6%, and mean left circumflex coronary blood flow by 47 +/- 6%, while heart rate increased by 44 +/- 13%. Increases in concentrations of arterial NE (5,050 +/- 1,080 from 190 +/- 20 pg/ml) and E (12,700 +/- 3,280 from 110 +/- 20 pg/ml) were far greater than increases in coronary sinus NE (1,700 +/- 780 from 270 +/- 50 pg/ml) and E (4,300 +/- 2,590 from 90 +/- 10 pg/ml). Net release of NE from the heart at rest was converted to a fractional extraction of 66 +/- 9% after hemorrhage. Fractional extraction of E increased from 16 +/- 6% at rest to 73 +/- 8% after hemorrhage. In cardiac-denervated dogs, hemorrhage (46 +/- 2.8 ml/kg) decreased mean arterial pressure by 39 +/- 15%, LV dP/dt by 36 +/- 10%, and mean left circumflex coronary blood flow by 36 +/- 13%, while heart rate increased by 24 +/- 10%. Hemorrhage increased arterial NE (1,740 +/- 150 from 210 +/- 30 pg/ml) and E (3,050 +/- 880 from 140 +/- 20 pg/ml) more than it increased coronary sinus NE (460 +/- 50 from 150 +/- 30 pg/ml) and E (660 +/- 160 from 90 +/- 20 pg/ml) but significantly less (P less than 0.05) than observed in intact dogs. These experiments indicate that hemorrhage, unlike exercise and sympathetic nerve stimulation, does not induce net overflow of NE from the heart.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Effects of cholinergic and beta-adrenergic blockade on orthostatic tolerance in healthy subjects

Cardiovascular responses during a graded lower body negative pressure (LBNP) protocol were compared before and after atropine and propranolol administration to test the hypothesis that both sympathetic and parasympathetic control of cardio-acceleration are associated with syncopal predisposition to orthostatic stress in healthy subjects. Eleven men were categorized into two groups having high (HT, N = 6) or low (LT, N = 5) tolerance based on their total time before the onset of presyncopal symptoms. HT and LT groups were similar in physical characteristics, fitness, and baseline cardiovascular measurements. Atropine treatment had no effect on LBNP tolerance or mean arterial pressure at presyncope, despite an atropine-induced increase in heart rate. Propranolol treatment reduced (p<0.05) LBNP tolerance in both groups. Diminished LBNP tolerance after propranolol administration was associated with reductions in cardiac output, whereas increase in systemic peripheral resistance from baseline to presyncope was unaffected by propranolol. Reduction in cardiac output and LBNP tolerance after beta blockade reflected a chronotropic effect because lower LBNP tolerance for the HT (-50%) and LT (-39%) groups was associated with dramatic reductions (p <0.05) in the magnitude of LBNP-induced tachycardia without significant effects on stroke volume at presyncope. Absence of an atropine-induced difference in cardiac output and systemic peripheral resistance between HT and LT groups failed to support the notion that cardiac vagal withdrawal represents a predominant mechanism that could account for differences in orthostatic tolerance. Because a reduction in LBNP tolerance in both HT and LT groups after propranolol treatment was most closely associated with reduced tachycardia, the data suggest that a primary autonomically mediated mechanism for maintenance of mean arterial pressure and orthostatic tolerance in healthy subjects is beta adrenergic-induced tachycardia.

Non-NASA Center↗

Certain cardiovascular indices predict syncope in the postural tachycardia syndrome

Patients with postural tachycardia syndrome (POTS) represent a patient population with orthostatic intolerance; some are prone to syncope, others are not. The underlying neurocardiovascular mechanisms are not completely understood. The current study was undertaken to assess if certain cardiovascular indices are predictive of syncope in POTS. We compared the response to tilt-up and the Valsalva maneuver in four groups: POTS patients who fainted (POTS-f; n = 11;31 +/- 11 years): POTS patients who did not faint (POTS-nf; n = 9; 29 +/- 9 years); normal controls (NLS; n = 13; 39 +/- 11 years); patients with generalized autonomic failure with orthostatic hypotension and syncope (n = 10; 59 +/- 14 years). Beat-to-beat heart rate (HR), systolic arterial pressure, diastolic arterial pressure (DAP) and pulse pressure (PP) were monitored using Finapres. Cardiac output, stroke volume (SV) and end-diastolic volume (EDV), and calculated total peripheral resistance (TPR) were recorded using thoracic electrical bioimpedance. An autonomic reflex screen which quantitates the distribution and severity of autonomic failure was also done. With the patient supine, all POTS patients (POTS-nf; POTS-f) had increased HR (p < 0.001) and reduced SV/EDV (p < 0.001) when compared with NLS. On tilt-up, POTS-f patients were significantly different from both NLS and POTS-nf patients; the most consistent alteration was a fall instead of an increase in TPR; other changes were a greater reduction in PP, a reduction (instead of an increment) in DAP, and a different pattern of changes during the Valsalva maneuver (excessive early phase II, attenuated or absent late phase II). Our results suggest alpha-adrenergic impairment with increased pooling or hypovolemia in POTS-f patients. We conclude that it is possible to identify the mechanism of syncope in POTS patients, and perhaps other patients with orthostatic intolerance and an excessive liability to syncope.

NASA Discipline Number 14-10↗

Recent bed rest results and countermeasure development at NASA

Bedrest studies of normal subjects provide opportunities to understand physiologic responses to supine posture and inactivity. Furthermore, head-down tilt has been a valuable procedure to investigate adaptation to microgravity and development of countermeasures to maintain the health and well-being of humans during space-flight. Recent bedrest experiments at NASA have ranged in duration from a few hours to 17 weeks. Acute studies of 6 degrees head-down tilt indicate that elevation of capillary blood pressure from 28 to 34 mm Hg and increased capillary perfusion in tissues of the head cause facial and intracranial edema. Intracranial pressure increases from 2 to 17 mm Hg going from upright posture to 6 degrees head-down tilt. Microvessels of the head have a low capacity to constrict and diminish local perfusion. Elevation of blood and tissue fluid pressures/flow in the head may also explain the higher headward bone density associated with long-term head-down tilt. These mechanistic studies of head-down tilt, along with a better understanding of the relative stresses involved with upright posture and lower body negative pressure, have facilitated development of suitable physiologic countermeasures to maintain astronaut health during microgravity. Presently no exercise hardware is available to provide a blood pressure gradient from head to feet in space. However, recent studies in our laboratory suggest that treadmill exercise using a graded lower-body compression suit and 100 mmHg lower body negative pressure provides equivalent or greater physiologic stress than similar upright exercise on Earth. Therefore, exercise within a lower body negative pressure chamber may provide a cost-effective and simple countermeasure to maintain the cardiovascular and neuro-musculoskeletal systems of astronauts during long-duration flight.

manned↗

Numerical simulation of the influence of gravity and posture on cardiac performance

A numerical model of the cardiovascular system was used to quantify the influences on cardiac function of intrathoracic pressure and intravascular and intraventricular hydrostatic pressure, which are fundamental biomechanical stimuli for orthostatic response. The model included a detailed arterial circulation with lumped parameter models of the atria, ventricles, pulmonary circulation, and venous circulation. The venous circulation was divided into cranial, central, and caudal regions with nonlinear compliance. Changes in intrathoracic pressure and the effects of hydrostatic pressure were simulated in supine, launch, sitting, and standing postures for 0, 1, and 1.8 G. Increasing intrathoracic pressure experienced with increasing gravity caused 12% and 14% decreases in cardiac output for 1 and 1.8 G supine, respectively, compared to 0 G. Similar results were obtained for launch posture, in which the effects of changing intrathoracic pressure dominated those of hydrostatic pressure. Compared to 0 G, cardiac output decreased 0.9% for 1 G launch and 15% for 1.8 G launch. In sitting and standing, the position of the heart above the hydrostatic indifference level caused the effects of changing hydrostatic pressure to dominate those of intrathoracic pressure. Compared to 0 G, cardiac output decreased 13% for 1 G sitting and 23% for 1.8 G sitting, and decreased 17% for 1 G standing and 31% for 1.8 G standing. For a posture change from supine to standing in 1 G, cardiac output decreased, consistent with the trend necessary to explain orthostatic intolerance in some astronauts during postflight stand tests. Simulated lower body negative pressure (LBNP) in 0 G reduced cardiac output and mean aortic pressure similar to I G standing, suggesting that LBNP provides at least some cardiovascular stimuli that may be useful in preventing postflight orthostatic intolerance. A unifying concept, consistent with the Frank-Starling mechanism of the heart, was that cardiac output was proportional to cardiac diastolic transmural pressure for all postures and gravitational accelerations.

Non-NASA Center↗