Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploration of non-resonant divertor features on the Compact Toroidal Hybrid

Abstract Non-resonant divertors (NRDs) separate the confined plasma from the surrounding plasma facing components (PFCs). The resulting striking field line intersection pattern on these PFCs is insensitive to plasma equilibrium effects. However, a complex scrape-off layer (SOL), created by chaotic magnetic topology in the plasma edge, connects the core plasma to the PFCs through varying magnetic flux tubes. The Compact Toroidal Hybrid (CTH) serves as a test-bed to study this by scanning across its inductive current. Simulations observe a significant change of the chaotic edge structure and an effective distance between the confined plasma and the instrumented wall targets. The intersection pattern is observed to be a narrow helical band, which we claim is a resilient strike line pattern. However, signatures of finger-like structures, defined as heteroclinic tangles in chaotic domains, within the plasma edge connect the island chains to this resilient pattern. The dominant connection length field lines intersecting the targets are observed via heat flux modeling with EMC3-EIRENE. At low inductive current levels, the excursion of the field lines resembles a limited plasma wall scenario. At high currents, a private flux region is created in the area where the helical strike line pattern splits into two bands. These bands are divertor legs with distinct SOL parallel particle flow channels. The results demonstrate the NRD strike line pattern resiliency within CTH, but also show the underlying chaotic edge structure determining if the configuration is diverted or limited. This work supports future design efforts for a mechanical structure for the NRD.

Physics↗

Pumped Thermal Energy Storage Using Low-Cost Particles and a Fluid Bed Heat Exchanger for Maximum Power Efficiency

Robust, efficient, cost-effective long-duration electricity storage (LDES) solutions can enhance grid resiliency, support existing transmission and distribution infrastructure, and enable a greater share of low-cost, variable alternative energy sources to penetrate the market. To meet this need, the project team at the National Renewable Energy Laboratory developed a transformative LDES system based on pumped thermal energy storage (TES) using low-cost particles and a fluid bed heat exchanger for maximum power efficiency (PUMP). The PUMP system is composed of high-temperature, low-cost particle TES coupled with an advanced pressurized fluid bed heat exchanger (PFB HX) that supports a high-efficiency pumped thermal energy storage (PTES) system integrated with concentrating solar thermal power (CSP). The PUMP project developed and de-risked a PFB HX and particle CSP system intended to be integrated with reversible turbomachinery and a modeling tool to assess PTES cost and performance.

14 SOLAR ENERGY↗

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump↗

Solar cell module assembly jig

The invention relates to the manufacture of solar cell modules and more particularly to a jig for assembling, positioning and maintaining the components under resilient pressure, while the entire assembly and the jig is subjected to heat for simultaneously soldering all of the various circuit connections; as well as structurally bonding the layers into a strong light weight structure which minimizes the tendency of the solar cells to crack and the other components and electrical connections to fracture.

Ofarrell, H. W.↗

Portland Urban Development: Quantifying and Visualizing Urban Heat with Compounding Vulnerabilities to Support Community Depaving Initiatives

Urban heat is a pressing concern in Portland, Oregon as climate change induced heat waves increase. Cities experience higher temperatures due to the urban heat island effect (UHI), and environmental injustice and disenfranchisement in minority communities expose low-income and Black, Indigenous, and People of Color (BIPOC) residents to more extreme and debilitating heat events. Our team identified Portland’s communities on the frontlines of urban heat impacts by overlapping environmental and social vulnerabilities using NASA Earth observations. We partnered with Depave, a Portland-based nonprofit that works alongside communities to replace pavement with greenspace in historically disenfranchised areas. Using Landsat 8 Thermal Infrared Sensor (TIRS) imagery, we mapped Land Surface Temperature (LST) and developed a heat-specific Social Vulnerability Index (SVI) through a Principal Component Analysis (PCA) to identify Portland’s communities with the highest potential heat vulnerability. Then, we calculated the temperature change of depaving in six case studies to quantify Depave's efforts in heat mitigation and environmental justice. Our analysis demonstrated that, throughout Portland, there are frontline communities experiencing high potential social vulnerability to extreme temperatures due to environmental injustices and over-pavement. Finally, Depave’s impact on urban heat is observable and quantifiable using remote-sensing data and tools, with an average of 1ºF LST decrease across the six case studies. We illustrated the significance of local urban heat mitigation efforts and propose next steps for conducting inclusive and intentional research that highlights the lived experiences and resilience of frontline communities.

Environmental justice↗

Solarize Fairbanks BRITE: Facilitating Efficient, Resilient Homes in Cold Climates

Solarize Fairbanks began an annual Solarize campaign in the Interior Alaska city in 2020, located in IECC climate zone 8, with a goal to increase the number of solar PV panels in the community. The campaign provides peer support, education, bulk purchase discounts, and simplified installation of solar PV technologies for homes, businesses, and nonprofits. In 2021, the campaign began offering energy audits to building and homeowners with a bulk discount; however, building owners were responsible for pursuing next steps on their own. In 2022, a diverse team of local, state, and federal partners formed a team to create a process to further facilitate energy efficiency improvements alongside solar PV technology. The resulting project, Solarize Fairbanks - Building Resilience for the Interior (BRITE) aims to build out an efficiency component over 3 years. If implemented, it will be the first efficiency add-on to a solarize campaign in Alaska. In year one, the team conducted energy audits of four nonprofits located in the cold climate of Interior Alaska and is providing technical assistance and fundraising for the nonprofits to pursue the recommended retrofits. These audits provided insights on the types of retrofits that could be expected to increase efficiency, comfort, and resiliency of buildings, including LED lighting retrofits, increased envelope insulation, improved building controls, and air source heat pump technology. A pre- and post-retrofit analysis will provide further insight on the energy savings and other benefits of the retrofits. It will also inform the offerings in the following years of the BRITE add-on to Solarize campaigns. In this presentation, program implementers will review the past campaigns of Solarize Fairbanks, summarize the energy efficiency and resiliency analyses of the nonprofit buildings, cover future plans for Solarize Fairbanks BRITE, and provide recommendations for other communities pursuing similar programs.

Alaska↗

Nuclear-Driven Integrated Energy Systems: A State-of-the-Art Review

Because of the growing concerns regarding climate change and energy sustainability, a transition toward a modern energy sector that reduces environmental effects while promoting social and economic growth has gained traction in recent years. Sustainable energy solutions, which include renewable and low-carbon sources such as nuclear energy and natural gas, could minimize emissions of greenhouse gases, enhance air and water quality, and encourage energy independence. Yet, the shift to a sustainable energy industry is fraught with difficulties, including governmental and regulatory obstacles, technological and economic limits, and societal acceptability hurdles. Addressing these issues would necessitate the development of long-term, durable, and cost-effective energy systems containing nuclear energy and associated with the generation of both electricity and other by-products required by industry. Integrated energy systems (IES) are a novel way to maximize the use of various energy resources and technologies in order to deliver dependable, efficient, and sustainable energy services. IES entail the integration of various energy systems, such as electricity, heating, cooling, and transportation, in respect to energy sustainability and a system’s resilience and flexibility. Their development and implementation require the cooperation of several parties, including energy providers and policymakers. This study provides a state-of-the-art literature review of the most creative nuclear-driven hybrid energy system applications and methodologies, from which the research challenges and prospects for effective IES implementation emerge.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

North Carolina Water Utility Builds Resilience with Distributed Energy Resources

As the frequency and duration of grid outages increase, backup power systems are becoming more important for ensuring that critical infrastructure continues to provide essential services. Most facilities rely on diesel generators, which may be ineffective during long outages owing to limited fuel supplies and high generator failure rates. Distributed energy resources such as solar, storage, and combined-heat-and-power systems, coupled with on-site biofuel production, offer an alternative source of on-site generation that can provide both cost savings and resilience (i.e., the ability to respond to catastrophic events with longer-term consequences). A mixed-integer linear program minimizes costs and maximizes resilience at a wastewater treatment plant in Wilmington, North Carolina. We find that the plant can reduce life-cycle energy costs by 3.1% through the installation of a hybrid combined-heat-and-power, photovoltaic, and storage system. When paired with existing diesel generators, this system can sustain full load for seven days while saving $664,000 over 25 years and reducing diesel fuel use by 48% compared with the diesel-only solution. This analysis informed a decision by the Cape Fear Public Utility Authority to allocate funds for the implementation of a combined-heat-and-power system at the wastewater treatment plant in fiscal year 2023. Finally, the benefits of deploying hybrid combined-heat-and-power technologies and the utilization of on-site biofuel production extend, on a national scale, to thousands of wastewater treatment facilities and other types of critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Klickitat Valley Health Central Utility Plant Modernization

This project replaced legacy heating and cooling equipment at Klickitat Valley Health (KVH), a rural hospital in Goldendale, Washington. Work included constructing a new chiller building, installing modern hydronic piping systems, replacing the main Emergency Department air handler (Air Handlining Unit (AHU-1)), upgrading electrical systems, and converting the Emergency Department wing from electric reheat to hydronic heating and cooling. Commissioning, testing, adjusting, and balancing were completed under this grant. These upgrades improve energy efficiency, operational resilience, and system reliability while preparing the campus for future electrification and renewable energy integration. They also support growth in healthcare services for a rural population. The project directly reduces energy costs and provides a foundation for future decarbonization measures, including a FEMA-funded microgrid and a large-scale ground source heat pump (GSHP) project. These follow-on initiatives would not have been possible without the hydronic backbone built through this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Structured large-pore foams improve thermal performance of LiMIT-style liquid lithium PFC

As magnetically confined fusion devices improve, the conditions at the walls become increasingly intense. Plasma facing components (PFCs) must withstand these extreme heat and particle loads without damage or degradation. Liquid lithium PFCs are known to be quite resilient, and the presence of lithium also serves to improve plasma properties. The liquid metal infused trench (LiMIT) concept is an open surface liquid lithium PFC design that has been tested extensively at the University of Illinois and in fusion devices around the world. LiMIT utilizes thermoelectric magnetohydrodynamics (TEMHD) to passively drive liquid lithium flow. This work demonstrates an extension of the LiMIT trench geometry to three dimensions. Additively manufactured large pore metallic foams maintain TEMHD drive while drastically improving heat flux handling and resistance to lithium dryout, a phenomenon where locally high TEMHD forces depresses the lithium level and exposes underlying solid structure. COMSOL multiphysics modeling of the system yields insight into the forces at play in dryout development, and shows the 3D structures can eliminate dryout. Here, low heat proof-of-concept experimental testing of the system matches computational results, and high heat flux electron beam tests more than double the proven operational range of a LiMIT-style PFC, to 6.8 MW m –2 , with no indications of dryout or impending damage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating agrivoltaics into smallholder farming systems to enhance food production and irrigation efficiency under climate stress

Smallholder agricultural growers and entrepreneurs (SAGE) have a crucial role in sustaining food security; their cultivation accounts for roughly 30% of global crop production and contributes substantially to the diversity and nutritional value of food systems. Despite their awareness of and flexibility to adapt to productivity challenges, SAGE communities remain highly vulnerable to heat and drought stress, which threatens both livelihoods and local food availability. While intensification and adaptive farm practices offer partial resilience, their capacity to buffer sudden climatic extremes remains limited. Agrivoltaics, the dual use of land for solar electricity generation and crop cultivation, has emerged as a promising strategy to enhance agricultural productivity and its resilience to climate extremes by altering microclimatic conditions. Although proven effective in hot and arid regions, the benefits of agrivoltaics for temperate climates and small-scale farms remain minimally explored. To address this gap, we evaluated the performance of a small-scale agrivoltaics system in a temperate climate for high-value crops, including leafy vegetables and garlic. We investigate whether the system can (i) protect crops during extreme heat events and (ii) enhance productivity and reduce irrigation requirements during hot and dry periods unsuitable for conventional production. Our findings provide evidence that agrivoltaics is a climate-resilient farming strategy under current and projected climate scenarios, capable of improving yields (by +43% to +127% for the leafy vegetables grown) and reducing water consumption, while creating complementary economic opportunities through decentralized energy generation systems. This work supports the integration of agrivoltaics into small-scale agricultural systems as an innovative pathway to strengthen food security, bolster farmer livelihoods, and enable multiple co-benefits from broader solar energy adoption.

14 SOLAR ENERGY↗

Household energy resilience in extreme weather events: An investigation of energy service importance, HVAC usage behaviors, and willingness to pay

Household energy resilience, particularly maintaining essential energy services within an acceptable and affordable level, is critical during extreme weather events (e.g., winter storms, heat waves) with power shortages or outages. However, the research on the importance and acceptable compromise levels of energy services, HVAC usage behavior changes, and willingness to pay (WTP) for energy services during disasters is limited. Therefore, this study investigates the importance and compromise of household energy services, HVAC usage behaviors, and WTP, as three key dimensions of household energy resilience, in both normal days and disaster scenarios through surveys (n=485). First, 12 common residential end-uses are grouped into high, mid, and low-priority services using hierarchical clustering, in which high-priority services (perceived as important and un-compromisable) include food cooking and storage (refrigerator and freezer) and thermal comfort (space heating and cooling), mid-priority services involve water heating and lighting, while low-priority services are mostly related to entertainment and housework (e.g., TV, laundry). Also, HVAC use patterns demonstrate that occupants become more energy conservative during disasters, e.g., reducing durations of running HVAC and adjusting temperature setpoints to save energy. In terms of energy cost, approximately 60% of respondents are willing to pay more to maintain energy services during disasters, although only 13% are prepared to pay over double the normal energy prices. The regression models further reveal that household energy resilience varies across different sociodemographic groups (e.g., age, income, family size) and is impacted by disaster experience and beliefs in clean energy and climate. In conclusion, these research findings provide important perspectives to understand household energy resilience and inform measures for disaster adaptation of households in extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anticipating water distribution service outages from increasing temperatures

With projected temperature increases and extreme events due to climate change for many regions of the world, characterizing the impacts of these emerging hazards on water distribution systems is necessary to identify and prioritize adaptation strategies for ensuring reliability. To aid decision-making, new insights are needed into how water distribution system reliability to climate-driven heat will change, and the proactive maintenance strategies available to combat failures. To this end, we present the model Perses, a framework that joins a water distribution network hydraulic solver with reliability models of physical assets or components to estimate temperature increase-driven failures and resulting service outages in the long term. A theoretical case study is developed using Phoenix, Arizona temperature profiles, a city with extreme temperatures and a rapidly expanding infrastructure. By end-of-century under hotter futures there are projected to be 1%–5% more pump failures, 2%–5% more PVC pipe failures, and 3%–7% more iron pipe failures (RCP 4.5–8.5) than a baseline historical temperature profile. Service outages, which constitute inadequate pressure for domestic and commercial use are projected to increase by 16%–26% above the baseline under maximum temperature conditions. The exceedance of baseline failures, when compounded across a large metro region, reveals potential challenges for budgeting, management, and maintenance. An exploration of the mitigation potential of adaptation strategies shows that expedited repair times are capable of offsetting the additional outages from climate change, but will come with a cost.

54 ENVIRONMENTAL SCIENCES↗

A trait-based framework for linking microbial communities with carbon transformations under precipitation change

Droughts are common throughout the world. As the climate changes, droughts may become more frequent and intense. Still, scientists are uncertain about how drought will affect the natural world, particularly the bacteria, fungi, and other microbes that live in soils. These tiny life forms are crucial because they control the Earth’s flows of carbon and essential nutrients. Researchers at the University of California, Irvine, and Lawrence Berkeley National Laboratory teamed up to study how the microbiome, or collection of bacteria and fungi in the soil, deals with drought. Since 2007, the researchers have used shelters with retractable roofs to prevent nearly half of normal rainfall from reaching grass and shrub ecosystems, and their soil microbiomes, in Southern California. The study team discovered that microbes have some clever tricks up their sleeve for surviving drought. When growing on dead grass as a food source, microbes ramp up production of specialized chemicals called osmolytes that keep their cells from drying out. But microbes growing on dead shrubs face another problem. Unlike grass, shrub leaves are a lousy food source. To digest and consume shrub leaves, microbes have to exude more enzymes, which act like biochemical chef knives that chop complex leaf molecules into bite-sized pieces. Carbon is the coin of the microbial realm, earned via enzyme action or slurping up dead plant juices. Microbes growing under normal conditions on tasty dead grass have it easy: they can spend most of their carbon currency on growth. With drought, life gets harder as microbes need to pay up for osmolytes and ramp down their growth. It gets worse with shrub leaves because microbes have to multi-task among growth, enzyme secretion, and osmolyte production. When drought hits, microbes on shrub leaves forgo the osmolytes, probably because losing the carbon revenue from enzyme investment would be a deal-breaker for survival. The next question tackled by the researchers asked how the genes controlling microbial lifestyles sort out across the tree of life. Most microbiologists thought these lifestyles would correspond to rather large branches on the tree. But the study team found that in fact, very closely related microbes differ in important and interesting ways. For example, bacteria that have nearly identical housekeeping genes respond distinctively to warming, rainfall, and plant chemistry. As a result, soil microbiomes are much richer in diversity than originally thought. And studying microbial diversity in much greater detail could open up many more possibilities for how microbial life deals with changing environmental conditions. Trying to understand microbial life without the fine details of genetic diversity is like trying to stream Netflix on a dial-up connection. By looking across the landscape, the researchers revealed that microbial diversity is absolutely critical for maintaining the planet’s flows of carbon and nutrients. The study team designed a new technology—microbial cages—for transplanting intact microbiomes. With the cages, the researchers could move microbiomes to novel environments and compare their ability to cycle carbon and nutrients. In some cases, performance tailed off when microbiomes found themselves in a new environment, but in other cases, performance rivaled or even exceeded that of the resident microbiome. And even the low performers eventually caught up to the native microbiomes if given sufficient time. These findings mean that microbiomes—at least in Southern California—may be resilient to climate shifts due to a high diversity of microbial lifestyles. Coping with heat and drought may literally be in their DNA. The last piece of the research puzzle, and a “Holy Grail” for microbial ecologists, is to forecast the behavior of diverse microbiomes. To meet this challenge, the study team developed new theory and computer models. For the first time, these models account for hundreds of different microbes and how their intricate lifestyles cope with drought. The models are starting to connect the tiniest microbes with the global cycles that sustain Earth’s farms, fields, and forests. With that connection, it will be easier for society to plan for a world with more droughts and other climate disruptions.

54 ENVIRONMENTAL SCIENCES↗

Energy Efficient, Cost-Effective Power and Co-Generation Technologies: Techno-Environmental Analysis

Development of energy solutions for addressing grid resiliency and energy efficiency while lowering greenhouse gas emissions is critical in today’s energy scenario. Chemical energy provides on demand power. Cogeneration technologies offer numerous benefits in meeting the growing energy demand while lowering the impact on environment. Utilization of waste heat from prime movers in conjunction with energy efficient heat pumps and renewable photovoltaics is an attractive approach. Efficient utilization of available resources to support current and future building energy needs targeting grid resiliency, energy and environmental security via co-generation approaches is the focus of this study. A detailed techno-environmental analysis of hybrid system configurations consisting of conventional and emerging technologies utilizing natural gas, electric grid, and renewable power resources along with heat recovery systems and heat pump technologies are analyzed and presented. The key objective is to present integrated system configurations and thermodynamic analysis of various co-generation systems suitable for providing building energy. Design solutions targeting low carbon footprint and high energy efficiency are presented.

Cheekatamarla, Praveen↗