At least 199 records · Page 11

Effects of atmospheric structure on radiative heating for Jupiter entry probe

New estimates of the radiative heat load to a Jupiter entry probe have been obtained for revised models of Jupiter's atmosphere based on the latest data from Pioneer 10 and 11 missions and earth-based experiments. The new estimates of the radiative heat load are compared with results obtained for the previous atmospheric models. The changes in Jupiter's atmospheric models cause a substantial reduction in the radiative heat load for the atmosphere denoted as 'cool', but only moderate reductions for the atmospheres denoted as 'nominal' and 'warm'. Results are also presented showing the effects of inertial entry angle for off-equatorial entries in the revised model atmospheres.

Sutton, K.↗

2025 Status Report - Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC

Fiberboard assemblies in the 9975 package were identified as susceptible to aging and degradation under long-term storage conditions. Thermal, mechanical, and physical properties have been measured on fiberboard samples aging for up to 20 years at accelerated conditions. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 containers in storage from 20 years to 40 years. These calculations addressed the potential for degraded fiberboard properties following 40 years in storage using degradation models. The 40 year storage evaluations assumed the degradation rates from initial values for density, dimensional, and thermal properties were 0.5% per year (i.e., after 40 years, the density, dimensional, and thermal properties of fiberboard were 80% of its initial values). The updated degradation models developed in this report were compared to the assumptions in those calculations, and the current results for fiberboard dimensions, density, axial and radial thermal conductivities, and energy absorption remain consistent with those calculations. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are purposely high to accelerate aging. These rates relate to environments that do not exist within KAC or are postulated to only occur as upset conditions that are unlikely to persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments (i.e., under 125 °F) used in this study. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 40 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 40 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next Generation Thermal Protection System for Outer Planet Probes and Orbiter

Saturn Probe and Ice Giant Orbiter along with in-situ Probe Missions continue to be very high priority mis-sions. A result of the advocacy by OPAG and other Analysis Groups, the 3D Woven, Dual-Layer HEEET thermal protection system, mature at TRL 6, has closed the TPS gap for extreme environment missions. A mid density follow on to DL HEEET, developed to meet earth entry requirements, is a Single Layer vari-ant of the 3D woven TPS, which provides a mass effi-cient single layer 3D Mid-Density TPS (3MDCP) that has been baselined as the heatshield for MSR EEV. Continued development of 3MDCP will elevate it to TRL 6 by 2025. Conformal-PICA (C-PICA) devel-opment was pursued to establish a more efficient and robust alternate to PICA, and it is at TRL 4+. Our rationale for the next generation of TPS de-velopment is based on the on the missions needs of the next decade Outer Planet missions that are unique and more demanding than any other destinations. Taking advantage of the recent planned development of sev-eral materials, the next generation of TPS offers a much more mass efficient option for small, medium, and large class Outer Planet missions. Saturn Probes: While mission designers are gen-erally interested in shallow entry to maintain the g-load during entry around 50g, the heat-load for shallow entry can range between (100 kJ/cm2 – 300 kJ/cm2), two orders of magnitude higher than Venus or Sample Return missions. TPS must not only offer protection but must be mass efficient to perform reasonable sci-ence. TPS mass can quickly become 50% or more of the mass of the entire entry system. Recent analysis performed shows Saturn Probe missions could signifi-cantly benefit from the single layer HEEET (SL-HEEET/3MDCP). A DL-HEEET based heatshield mass could be ~ (40% -50%), SL-HEEET can provide additional (30% - 50%) mass savings. At the same time, C-PICA can provide (30% - 50%) mass savings on the backshell. The combined mass savings can be significant enough to carry an additional probe, if de-sired. Ice Giant Aerocapture Missions: Aerocapture mission architectures can provide significant ad-vantage over traditional propulsive insertion missions in multiple ways. 1) Reduced trip time ~ (4- 6) years (30% -40%), 2) Enables placing the orbiter, probe, and lander, all together and 3) Allows for greater science mass (probes and landers) due to mass efficiency. The delivery of a probe from orbit makes it easier and eliminates mission design constraints by HEEET for direct entry [4] of probes and allows for more targeted in-situ science once the Orbiter is able to collect data. In the past 20 years, progress made in GN&C for lift-guided entry missions (MSL, Orion EFT1, Mars 2020) and the expertise in blunt body aerodynamics at large scale (~ 5m) has led the EDL community to conclude that aerocapture is a “go do” engineering activity. An aerocapture mission that will deplete the excess energy of a fast arrival mission will require a mass efficient TPS that can handle extreme heat-load, ~ (100 kJ/cm2 – 500 kJ/cm2). Hence TPS, feasibility as well as mass efficiency requires assessment. Utilizing the recent developments, a comprehensive, bounding analysis was done to establish the potential for SOA (HEEET) system as well as emerging new TPS such as SL-HEEET and C-PICA. In this proposed poster, we will outline the process by which we establish bounding aerocapture trajecto-ries for hyperbolic excess velocities ranging from 27 km/s to 35 km/s, for low L/D (~ 0.4) configurations and determine conservative/bounding estimate of aer-othermal environment by using a combination of CFD simulations and stagnation point heating estimates [7]. This engineering approach allows us to assess the TPS need vs. TPS capability and determine the applicability of existing TPS. Once an applicable suite of TPS is determined, the TPS thickness and mass are comput-ed. We show that the TPS mass fraction can be as low as 5% to as high as 20%, depending on the use of ad-vanced TPS, while HEEET is sufficient but will require 50% of the entry mass.

E Venkatapathy↗

Radiator heat rejection options for Shuttle payloads

The paper describes four separate advanced space radiator concepts that have been pursued in an integrated effort to develop multipayload use, low-cost heat rejection systems which can overcome the limitations of current radar systems. These four concepts are the following: (1) a wide heat load range, modularized space radiation system; (2) a heat rejection subsystem designed as a compact self-contained heat rejection module which provides a refrigeration cycle to accomodate a wide variation in payload heat loads and cooling temperature requirements; (3) a lightweight flexible fin radiator system with heat rejection capability; and (4) a radiator which does not require a circulating coolant on the radiator panel with heat pipes and thus particularly applies to very-long-duration free-flying payloads where long life reliability is an overriding design parameter. The Orbiter active thermal control system is briefly described.

Ellis, W. E.↗

Loading and heating of a large flat plate at Mach 7 in the Langley 8-foot high-temperature structures tunnel

Surface pressure and cold-wall heating rate distributions (wall-temperature to total-temperature ratio approximately 0.2) were obtained on a large, flat calibration panel at a nominal Mach number of 7 in an 8-foot high-temperature structures tunnel. Panel dimensions were 42.5 by 60.0 in. Test objectives were: (1) to map available flat-plate loading and heating provided by the facility and (2) to determine effectiveness of leading-edge bluntness, boundary-layer trips, and aerodynamic fences in generating a uniform, streamwise turbulent flow field over the test surface of a flat-sided panel holder.

Deveikis, W. D.↗

Evaluation of boundary layer transition criteria for space shuttle orbiter entry

A comparison was made of the effect of boundary layer transition on center-line heating in a conical and a normal-shock flow field. It was shown that the time of transition onset (and, hence, the heating parameter) is significantly influenced by the choice of transition criterion in the normal-shock flow but that this parameter is much less sensitive to the transition criterion in a conical flow field. An evaluation of the effects of boundary layer transition on center-line heating in the conical flow field has shown that the temperatures are less affected by the use of various transition crieria than are heat loads. This difference is due to the delay in the time of transition onset predicted by those criteria with high transition Reynolds numbers. The criteria which predict the most severe thermal environment are those of fully turbulent flow throughout the entry, because transition occurs early in the trajectory for each of these criteria, they tend to predict similar values of maximum temperature and total heat load especially at center-line locations aft of 0.6. Evaluation of center-line heating generated by various trajectory shaping approaches has shown that the maximum surface temperature distribution was not significantly affected by the shaping technique. However, the heat load distribution is influenced, particularly on the forward portion of the vehicle.

Helms, V. T., III↗

Space radiator trade studies for the 25 kW Power System

Advanced radiator designs which will survive the meteoroid hazard of near earth orbit for five years are evaluated for the 25 kW Power System. Weight comparisons of heat pipe radiators and pumped fluid radiators incorporating meteoroid bumpers are presented for the initial 25 kW Power System and growth versions to 250 kW. The heat pipe concept is enhanced by a new design of the thermal interface between the heat pipe and coolant loop. The results show small weight differences between the advanced heat pipe and pumped fluid concepts for heat loads up to about 50 kW. The heat pipe panels have a weight advantage for larger heat loads.

Howell, H. R.↗

The heating environment during Martian atmospheric descent

It has been shown that a vehicle with a lift/drag ratio of 2.3 entering the Martian atmosphere at parabolic speed of 5 km/sec, or from a low orbit at 3.5 km/sec, has a very large landing footprint. At the 5-km/sec entry speed, the trajectory exhibits large skipping motions; however, a lateral range of up to 3300 km is attainable. The entries from low satellite orbit yield a gliding lateral range of 2500 km. The distances correspond to latitude changes of 57 and 42 deg, respectively. The high-speed, skipping entries were accompanied by the most intense heating. The peak stagnation point convective rates varied from 59 W/sq cm to 88 W/sq cm for partially and fully catalytic walls, respectively; the corresponding equilibrium wall temperatures were 1900 K and 2100 K. The peak heating at a wing leading-edge point reached 50 W/sq cm because of the presence of a transitional boundary layer. The lower-speed, gliding entries experienced much milder heating with a peak stagnation point rate of about 14 W/sq cm, resulting in a wall temperature near 1300 K. However, the longer duration of the gliding entries resulted in comparable heat loads for both entry speeds. The highest heat loads approached values experienced by the Shuttle orbiter stagnation point during a typical entry.

Tauber, Michael E.↗

A Morphing Radiator for High-Turndown Thermal Control of Crewed Space Exploration Vehicles

Spacecraft designed for missions beyond low earth orbit (LEO) face a difficult thermal control challenge, particularly in the case of crewed vehicles where the thermal control system (TCS) must maintain a relatively constant internal environment temperature despite a vastly varying external thermal environment and despite heat rejection needs that are contrary to the potential of the environment. A thermal control system may be required to reject a higher heat load to warm environments and a lower heat load to cold environments, necessitating a relatively high turndown ratio. A modern thermal control system is capable of a turndown ratio of on the order of 12:1, but crew safety and environment compatibility have constrained these solutions to massive multi-loop fluid systems. This paper discusses the analysis of a unique radiator design that employs the behavior of shape memory alloys (SMAs) to vary the turndown of, and thus enable, a single-loop vehicle thermal control system for space exploration vehicles. This design, a morphing radiator, varies its shape in response to facesheet temperature to control view of space and primary surface emissivity. Because temperature dependence is inherent to SMA behavior, the design requires no accommodation for control, instrumentation, or power supply in order to operate. Thermal and radiation modeling of the morphing radiator predict a turndown ranging from 11.9:1 to 35:1 independent of TCS configuration. Coupled thermal-stress analyses predict that the desired morphing behavior of the concept is attainable. A system level mass analysis shows that by enabling a single loop architecture this design could reduce the TCS mass by between 139 kg and 225 kg. The concept has been demonstrated in proof-of-concept benchtop tests.

Cognata, Thomas J.↗

A Morphing Radiator for High-Turndown Thermal Control of Crewed Space Exploration Vehicles

Spacecraft designed for missions beyond low earth orbit (LEO) face a difficult thermal control challenge, particularly in the case of crewed vehicles where the thermal control system (TCS) must maintain a relatively constant internal environment temperature despite a vastly varying external thermal environment and despite heat rejection needs that are contrary to the potential of the environment. A thermal control system is in other words required to reject a higher heat load to warm environments and a lower heat load to cold environments, necessitating a quite high turndown ratio. A modern thermal control system is capable of a turndown ratio of on the order of 12:1, but for crew safety and environment compatibility these are massive multi-loop fluid systems. This paper discusses the analysis of a unique radiator design which employs the behavior of shape memory alloys (SMA) to vary the turndown of, and thus enable, a single-loop vehicle thermal control system for space exploration vehicles. This design, a morphing radiator, varies its shape in response to facesheet temperature to control view of space and primary surface emissivity. Because temperature dependence is inherent to SMA behavior, the design requires no accommodation for control, instrumentation, nor power supply in order to operate. Thermal and radiation modeling of the morphing radiator predict a turndown ranging from 11.9:1 to 35:1 independent of TCS configuration. Stress and deformation analyses predict the desired morphing behavior of the concept. A system level mass analysis shows that by enabling a single loop architecture this design could reduce the TCS mass by between 139 kg and 225 kg. The concept is demonstrated in proof-of-concept benchtop tests.

Cognata, Thomas J.↗

Superfluid helium 2 liquid-vapor phase separation: Technology assessment

A literature survey of helium 2 liquid vapor phase separation is presented. Currently, two types of He 2 phase separators are being investigated: porous, sintered metal plugs and the active phase separator. The permeability K(P) shows consistency in porous plug geometric characterization. Both the heat and mass fluxes increase with K(P). Downstream pressure regulation to adjust for varying heat loads and both temperatures is possible. For large dynamic heat loads, the active phase separator shows a maximum heat rejection rate of up to 2 W and bath temperature stability of 0.1 mK. Porous plug phase separation performance should be investigated for application to SIRTF and, in particular, that plugs of from 10 to the minus ninth square centimeters to 10 to the minus eighth square centimeters in conjunction with downstream pressure regulation be studied.

Lee, J. M.↗

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

Design and Analysis of High Heat Flux Plasma-Facing Components for NSTX Upgrade

The National Spherical Tokamak Experiment (NSTX) upgrade (NSTX-U) requirements lead to enhanced heat loads on plasma-facing components (PFCs) especially in the divertor regions, where normal heat flux density can reach up to 8 MW/m 2 . For these high heat flux (HHF) regions, the PFCs were redesigned, to use castellations which relieved the thermal stresses associated with high incident heat flux. Another design feature of HHF PFCs is the absence of front face mounting holes which create localized areas of high temperature and thermal stress concentrations. Optimized shaping of the front face of the HHF PFCs eliminates regions where the front face is perpendicular to the heat flux direction during normal helicity operation and spreads the heat load. A unique mechanism was designed to connect PFC tiles to the NSTX-U center stack casing using locking features accessible from the low heat flux regions. Isotropic graphite was selected as the HHF PFC tile material. Initial tile design parameters were accessed using analytical expressions for pulsed heat flux loading. A working prototype of the locking mechanism was created during the initial stages of the design to prove the concept performance. This article presents an overview of the divertor HHF PFC design and the results of the thermal and structural analyses performed using ANSYS software. The results of the analyses cover normal operating conditions and disruptions which impose electromagnetic (EM) loads from eddy and halo currents. The 3-D, transient, nonlinear analyses took into account the temperature-dependent properties of the materials, friction interfaces between the parts, and variable electric properties of the parts and interfaces. The results confirm that the HHF PFC tiles remain within the allowable limits for the loads defined by the NSTX-U Recovery Project. In addition, tolerance stack up analyses were performed to ensure tile performance in the worst possible assembly configuration. Finally, the design process was completed successfully, and the NSTX HHF PFC tiles are currently in the production phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transient Convection Due to Imposed Heat Flux: Application to Liquid-Acquisition Devices

A model problem is considered that addresses the effect of heat load from an ambient laboratory environment on the temperature rise of liquid nitrogen inside an enclosure. This model has applications to liquid acquisition devices inside the cryogenic storage tanks used to transport vapor-free propellant to the main engine. We show that heat loads from Q = 0.001 to 10 W, with corresponding Rayleigh numbers from Ra = 109 to 1013, yield a range of unsteady convective states and temperature rise in the liquid. The results show that Q = 1 to 10 W (Ra = 1012 to 1013) yield temperature distributions along the enclosure height that are similar in trend to experimental measurements. Unsteady convection, which shows selfsimilarity in its planforms, is predicted for the range of heat-load conditions. The onset of convection occurs from a free-convection-dominated base flow that becomes unstable against convective instability generated at the bottom of the enclosure while the top of the enclosure is convectively stable. A number of modes are generated with small-scale thermals at the bottom of the enclosure in which the flow selforganizes into two symmetric modes prior to the onset of the propagation of the instability. These symmetric vertical modes transition to asymmetric modes that propagate as a traveling-wave-type motion of convective modes and are representative of the asymptotic convective state of the flow field. Intense vorticity production is created in the core of the flow field due to the fact that there is shear instability between the vertical and horizontal modes. For the higher Rayleigh numbers, 1012 to 1013, there is a transition from a stationary to a nonstationary response time signal of the flow and temperature fields with a mean value that increases with time over various time bands and regions of the enclosure.

Duval, Walter M. B.↗

Capillary Pumped Loop 3 Flight Experiment Overview

The Capillary Pumped Loop 3 (CAPL 3) Experiment is a follow on to the CAPL 1 and CAPL 2 experiments which flew on STS-60 (2/94) and STS-69 (9/95), respectively. CAPL 3 is tentatively scheduled to fly on the Space Shuttle in late 2000 as part of the Hitchhiker Experiments Advancing Technology (HEAT) payload. The experiment is a joint Naval Research Laboratory (NRL)/Goddard Space Flight Center (GSFC) payload which will meet technology objectives for both the Department of Defense and NASA. The primary objective of CAPL 3 is to demonstrate in space a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and at least 50% heat load sharing with hardware for a deployable radiator. CAPL 3 is a full scale CPL system with four parallel capillary evaporators. The loop also contains a capillary starter pump, 8 parallel direct condensation condensers with associated flow regulators, a back pressure regulator, a two-phase reservoir, and various headers and transport tubing. A variable conductance heat pipe is located between one of the evaporators and the experiment radiator to provide a cooling source for the demonstration of heat load sharing. The experiment has an operating power range of 100 W to approximately 1400 W. The experiment ammonia charge will cause it to transition to a fixed conductance mode of operation if the radiator usage reaches 85%. Ambient functional tests have been performed on the experiment. Tests performed included start-up, low power, power cycles, high power, heat load sharing, variable/fixed conductance transition, saturation temperature changes, and pressure primes while the system was operating. The majority of the testing was performed at an ammonia saturation temperature of 30C, but a few tests were done at temperatures above and below this. The testing was highly successful. Details of the tests performed and a discussion of the results will be given in the presentation.

Ottenstein, Laura↗

Blade and Rim Seal Design of a First Stage High Pressure Turbine for a 300 MWe Supercritical CO2 Power Cycle

A first stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design 3D with objectives of increasing efficiency and decreasing heat load to the blade. The National Institute of Standards and Technology Reference Fluid Thermodynamic and Transport Properties Database (NIST REFPROP) [1] data for supercritical CO2 is formatted into tables of bicubic polynomial coefficients for use in condensable gas simulations in FINE/Turbo. Nearly 3000 unique shapes are evaluated via three-dimensional Reynolds Averaged Navier Stokes simulations, yielding increases in efficiency of up to 0.85 percentage points and decreases in heat load of 14%. A final blade, deemed the advanced blade, is chosen for future experimental analysis. Following this, a squealer tip optimization is performed on both the baseline and advanced blade designs. This optimization resulted in a performance gain of 1.25 points in efficiency and 15% reduction in tip heat load compared to the baseline flat tip design at the same clearance. In tandem, an optimization of the rotor-stator platform rim seal is performed using a parametrized geometry allowing for straight, meandering, and knife seal cavities. This multi-objective optimization focuses on decreasing the cooling mass flow and increasing the heat flux from the rotor and stator disk. The optimization resulted in cooling mass flow decreases of up to 26% while maintaining the average heat flux on the rim seal.

Tuite, Logan↗

Aerothermal Analysis of the Rocket Lab Venus Probe Heatshield

This document provides an overview of the aerothermodynamic analyses performed by the Aerothermodynamics Branch at NASA Langley Research Center for the Rocket Lab Venus Probe (RLVP). In addition to defining the baseline heating environment to the heatshield, this document pursues the experimental validation of key physical models at RLVP-relevant conditions. This experimental validation analysis, which captures the model form uncertainty, is used as one of two primary components of the margin assessment, where the other component is the parametric uncertainty. These model form (experimental) and parametric uncertainty components are used to construct a spatial and time varying margin for the heating to the RLVP heatshield. The margin is evaluated as the sum of the parametric and model form uncertainty components. The model form uncertainty is defined as the difference between the RLVP-relevant measurements and their simulations, using the upper limit uncertainty bounds for both the measurements and simulations in the comparisons. The differences in the dominant physics in the stagnation region and flank lead to the separate RLVP-relevant measurements for assessing the model form uncertainty in these two regions. These regions are addressed as follows: Stagnation Region Heating Environment: For the high-temperature stagnation-region, both the radiative heating and impact of blowing on convective heating are significant, while the impacts of turbulence and roughness are negligible. Coupled radiation and ablation LAURA/HARA solutions with ray-tracing provide the radiative heating over the entire vehicle, including the contributions from the Venus atmosphere and ablation species. Non-ablating LAURA simulations provide the convective heating. During the material-response computation typically used for TPS sizing, this non-ablating convective heating is corrected for the impact of ablation using the blowing correction. Coupled ablation LAURA simulations that capture finite-rate sur-face processes show that this blowing correction may be non-conservative over most of the heatshield. This non-conservatism is due to hydrogen recombination in the finite-rate surface model, which tends to increase the coupled ablation convective heating to near the non-ablating values, therefore making any reduction in the non-ablating value through the blowing correction non-conservative. This non-conservatism due to H catalysis is captured in the parametric component of the margin. The best available ground-test measurements that capture the impact of blowing on stagnation region convective heating, at RLVP-relevant conditions, indicate that the current blowing reduction model is non-conservative by up to 20% at RLVP-relevant blowing rates (the coupled blowing simulations were also non-conservative). Because of the relatively low velocity of the ground tests and the non-Venus atmospheric chemistry, these measurements do not capture the chemistry and therefore do not inform the uncertainty due to H catalysis. However, they do capture the fluid mechanics of blowing. The non-conservatism of the blowing correction implied by these measurements is covered by the model form component of the margin, which leads to total margin values over 50%. For the radiative heating, the shock-tube informed bias approach suggests a model form uncertainty of roughly 20%, while the parametric uncertainty analysis suggests values over 100%. The combined stagnation-point radiation margin of over 100% leads to peak margined radiative heating values of over300 W/cm2, which remains small relative to the peak margined convective heating of nearly 2000 W/cm2. Based on this analysis, at the stagnation point, the peak margined heat rate is 2203 W/cm2 and the margined total heat load is 31.5 kJ/cm2 for the current nominal trajectory. Flank Heating Environment: The forebody flank (and near-shoulder) heating environment is dominated by the impact of turbulence, roughness augmentation, and ablation on the convective heating. An extensive collection of ground test measurements with RLVP-relevant turbulence and roughness is studied to show that the maximum difference between the simulated and measured convective heating is 5%. However, with the exception of the Holden measurements from the 1980s, these measurements do not include roughness elements extending into the supersonic region of the boundary layer, which is likely to occur for RLVP (due to the 45 degree sphere-cone geometry). The interaction between the supersonic flow and roughness could cause convective heating augmentation fundamentally different than for locally subsonic flow. Although these Holden measurements are consistent with the other measurements considered, another path was pursued to assure that the rough-ness height extending into supersonic flow does not fundamentally change the roughness augmentation. This additional path was a computational effort to resolve the roughness elements in the CFD grid, so that the interaction be-tween the roughness elements and locally supersonic flow may be simulated in detail. This roughness-resolved CFD simulation is feasible because of the RLVP forebody TPS’s patterned roughness, which may be approximated analytically, and because of the axisymmetric nominal flow field, which allows a narrow surface region to be simulated and therefore make the computational expense feasible. These grid-resolved roughness simulations, which are performed at actual RLVP flight conditions, result in heating augmentation values that are below the design approach for roughness augmentation. This provides evidence that the design approach for RLVP roughness augmentation is sufficient. Based on this analysis, at this flank or near-shoulder location, the peak margined total heat rate is 2088 W/cm2and the margined total heat load is 26.0 kJ/cm2for the current nominal trajectory. Heat flux, shear, pressure and heat transfer coefficient at the RLVP stagnation point and near shoulder location are evaluated for the entire trajectory, and curved fit to a functional form of F=AρB∞UC∞. These simplified relationships for the nominal and margined aerothermal environments are referred to as aerothermal indicators, and presented at the end of this document.

Christopher O Johnston↗

Method Improvements in Thermal Analysis of Mach 10 Leading Edges

Several improvements have recently been made in the thermal analysis methods for leading edges of a hypersonic vehicle. The leading edges of this vehicle undergo exceptionally high heat loads that incorporate extreme spatial gradients as well as severe transients. Due to the varying flight conditions, complex geometry, and need for thermal loads at many points along the trajectory, full computational fluid dynamics (CFD) analysis of the aeroheating; loads is not feasible. Thus, engineering methods must be used to determine the aeroheating on the vehicle surfaces, and that must be utilized in the thermal analysis. Over the last year, the thermal analysis of a hypersonic vehicle has been enhanced in several ways. Two different engineering codes are used to predict aeroheating loads: one over the curve near the stagnation point, and the other on flat surfaces downstream of the leading edge. These two are matched together at the intersection point using a method that allows closer approximation of CFD results. User-developed FORTRAN, which is part of the thermal solver PATRAN Thermal, is used to accomplish this. The customizable FORTRAN code also allows use of many different time- and space-dependent factors, interpolation of the heat load in time and space, and inclusion of both highly swept and unswept grid structures. This FORTRAN is available to other PATRAN users who may want to accomplish a similar objective in analysis. Flux, rather than convective coefficient, is used to define heat loads, which allows more accurate analysis as well as better application of margins. Improvements have also been made in more efficient utilization of imported CAD geometry, by creating faces on solids to facilitate load application.

Amundsen, Ruth M.↗