The development and testing of a regenerable CO2 and humidity control system for Shuttle

A regenerable CO2 and humidity control system is presently being developed for potential use on Shuttle as an alternate to the baseline lithium hydroxide (LiOH) system. The system utilizes a sorbent material (designated 'HS-C') to adsorb CO2 and water vapor from the cabin atmosphere and desorb the CO2 and water vapor overboard when exposed to a space vacuum. Continuous operation is achieved by utilizing two beds which are alternately cycled between adsorption and desorption. This paper presents the significant hardware development and test accomplishments of the past year. A half-size breadboard system utilizing a flight configuration canister was successfully performance tested in simulated Shuttle missions. A vacuum desorption test provided considerable insight into the desorption phenomena and allowed a significant reduction of the Shuttle vacuum duct size. The fabrication and testing of a flight prototype canister and flight prototype vacuum valves have proven the feasibility of these full-size, flight-weight components.

Boehm, A. M.↗

Flight prototype CO2 and humidity control system

A regenerable CO2 and humidity control system is presently being developed for potential use on the space shuttle as an alternative to the baseline lithium hydroxide system. The system utilizes a sorbent material (designated HS-C) to adsorb CO2 and water vapor from the cabin atmosphere and desorb the CO2 and water vapor overboard when exposed to a space vacuum. Continuous operation is achieved by utilizing two beds which are alternately cycled between adsorption and desorption. A shuttle vehicle integration study showed that the HS-C system offers substantial weight advantages compared to the baseline shuttle orbiter expendable lithium hydroxide CO2 removal system for extended missions beyond the nominal design of four men for seven days. This study defined a system packaging envelope in the area presently occupied by the LiOH cartridges.

Rudy, K. M.↗

The effect of ambient temperature and humidity on the carbon monoxide emissions of an idling gas turbine

Changes in ambient temperature and humidity affect the exhaust emissions of a gas turbine engine. The results of a test program employing a JT8D combustor are presented which quantize the effect of these changes on carbon monoxide emissions at simulated idle operating conditions. Analytical results generated by a kinetic model of the combustion process and reflecting changing ambient conditions are given. It is shown that for a complete range of possible ambient variations, significant changes do occur in the amount of carbon monoxide emitted by a gas turbine engine.

Kauffman, C. W.↗

The Temperature Humidity Infrared Radiometer (THIR) subsystem

The infrared radiation from the earth in two spectral bands during both day and night portions of the orbit is measured. Pictures of cloud cover, three dimensional mappings of cloud cover, temperature mappings of clouds, land, and ocean surface, cirrus cloud content, atmospheric contamination, and relative humidity are provided.

Cherrix, G. T.↗

High resolution vertical profiles of wind, temperature and humidity obtained by computer processing and digital filtering of radiosonde and radar tracking data from the ITCZ experiment of 1977

Results are presented from computer processing and digital filtering of radiosonde and radar tracking data obtained during the ITCZ experiment when coordinated measurements were taken daily over a 16 day period across the Panama Canal Zone. The temperature relative humidity and wind velocity profiles are discussed.

Danielson, E. F.↗

Kinetics of the Humid Aging of Magnetic Recording Tape

The kinetics of the hydrolysis of polyester urethane binders of magnetic recording tape is described. Kinetic data were generated from measurements of acetone-extractable hydrolyzed binder products versus time for various humidity-temperature environments. These data can be described by a linear, single product, reversible rate equation. This equation, coupled with measurements on the effect of hydrolysis on recorded tape performance, is used to predict proper environmental storage conditions for magnetic tape.

Bertram, H. N.↗

Investigation of some effects of humidity on aerodynamic characteristics on a 10-percent-thick NASA supercritical airfoil

An investigation was conducted in the Langley 8-foot transonic pressure tunnel to determine the effects of wind-tunnel humidity on the aerodynamic characteristics of a 10-percent-thick NASA supercritical airfoil. Effects of dewpoint variation from 267 K (20 F) to 294 K (70 F) were investigated. The tunnel stagnation temperature was 322 K (120 F) and the stagnation pressure was 0.1013 MN/09 m (1 atm).

Jordan, F. L., Jr.↗

Investigation at near-sonic speed of some effects of humidity on the longitudinal aerodynamic characteristics of an NASA supercritical wing research airplane model

The Langley 8-foot transonic pressure tunnel was used in an effort to determine the effects of humidity at near-sonic speed on the longitudinal aerodynamic characteristics and wing pressure distributions of an area-rule research airplane model with an NASA supercritical wing. Effects of dewpoint at the normal tunnel operating stagnation temperature of 48.9 C (120 F) and effects of stagnation temperature at a relatively high dewpoint of 15.6 C (60 F) were investigated. The test tunnel stagnation pressure was 101 325 N/sq m (1 atmosphere).

Jordan, F. L., Jr.↗

Validation of Nimbus-7 temperature-humidity infrared radiometer estimates of cloud type and amount

Estimates of clear and low, middle and high cloud amount in fixed geographical regions approximately (160 km) squared are being made routinely from 11.5 micron radiance measurements of the Nimbus-7 Temperature-Humidity Infrared Radiometer (THIR). The purpose of validation is to determine the accuracy of the THIR cloud estimates. Validation requires that a comparison be made between the THIR estimates of cloudiness and the 'true' cloudiness. The validation results reported in this paper use human analysis of concurrent but independent satellite images with surface meteorological and radiosonde observations to approximate the 'true' cloudiness. Regression and error analyses are used to estimate the systematic and random errors of THIR derived clear amount.

Stowe, L. L.↗

Determining Monthly Mean Humidities From Satellite Data

Report describes statistical study to estimate monthly average humidity of marine surface layer of atmosphere from measurements by radiometers on satellites. Study part of continuing effort to determine flux density of latent heat due to evaporation at ocean surface. Such observations and measurements important because latent-heat flux affects weather and temperature and salinity of upper ocean layers.

Liu, W. Y. T.↗

Water permeation and dielectric breakdown. Water permeability in Pub Tedlar. Pub/Tedlar as a function of temperature and humidity

Moisture transport and dielectric breakdown of polyvinyl butyral (PVB), Tedlar, and PVB/Tedlar composites were addressed. Data for the temperature range between 20 and 80 C showed that the moisture flux through the composite is governed by the slower material; and that the composite permeability is intermediate to those of the component material, as predicted by theory. Data for Tedlar at 71 C, showing the dependence of moisture flux on relative humidity, was also presented. Dielectric breakdown data were less precise and less conclusive. The generally applied theoretical model does not match the experimental data. The PVB/Tedlar composite exhibited greater voltage breakdown resistance than either component. Testing of EVA and EVA/Tedlar composites is underway.

Orehotsky, J.↗

A Meteorological (humidity, temperature, aerosols)) mobile dial system: Concepts and design

Since 1982 a program was conducted to develop a mobile meteorological (humidity, temperature, aerosols) Differential Absorption Lidar (DIAL) devoted to the studies of the nuclear power plant atmospheric surroundings. The measurement objectives are defined according to the user needs and the lidar feasibility. The concepts and design adopted to meet both the requirement and the measurement objectives are described. Each sub-system is addressed sequentially: transmitting system, receiving system, detection system, and post detection.

Cahen, C.↗

Statistical relation between monthly mean precipitable water and surface-level humidity over global oceans

Monthly summaries of atmospheric soundings taken over 17 years from 49 midocean stations at small islands and weather ships distributed over major oceans are examined. Over tropical oceans, precipitable water is found to be a better predictor of surface-level humidity than surface-level air temperature. A statistical relation in the form of a polynomial is derived; from this relation, the monthly-mean, surface-level mixing ratio can be computed from monthly-mean precipitable water. The root-mean-square differences between the measured and derived values were found to be less than 8 x 10 to the -4th over most ocean areas. Such a relation is useful in deriving large-scale evaporation and latent heat flux data from the ocean, using spaceborne observations. The temporal and spatial variabilities of data deviations from this relation are examined. This relation is found to be applicable to all major ocean basins and can be used to monitor interannual variability. Boundary-layer thermodynamics of different air masses are suggested as an explanation of some characteristics of this relation.

Liu, W. T.↗

Temperature, Humidity, And Polymer Aging

Report presents analysis of experimental data on electrical resistivity of polymer (polyvinyl butyral) as function of temperature and relative humidity. Resulting theoretical expression for electrical resistivity resembles generally accepted empirical law for the corrosion rate.

Cuddihy, Edward F.↗

Development of a regenerable humidity and CO2 control system for an advanced EMU

A 5-h-regenerable nonventing humidity and CO2 control subsystem (HCCS) technology demonstration unit is being developed for potential use in an Advanced Extravehicular Mobility Unit for Space Station application. The HCCS incorporates a weak-base-anion exchange resin packed in a metal-foam-matrix heat exchanger. This system simultaneously removes CO2 and water vapor, with the resulting exothermic heat of reaction rejected to the heat exchanger. The system has no moving parts, resulting in a highly reliable simple configuration. Regeneration may be accomplished via internal heating and vacuum.

Nalette, Timothy A.↗

Deterioration of ZnO/SiO2 diode packages in high humidity

A case study is reported in which the ZnO/SiO2 glass used to package a power rectifier combined with the design to produce a catastropic corrosion failure of the system. Metallic Zn inclusions, present in the glass, played a critical role in creating a conductive path for corrosion currents. Actual equipment failure was the result of an open circuit trace created by corrosion. It is concluded that the presence of Zn inclusions in the glass of this type of package may result in long-term reliability problems for equipment used in high humidity environments.

Evans, John↗

Vibrational-vibrational coupling in air at low humidities

Calculations of sound absorption in air are traditionally based on the assumption that molecular relaxations in N2 and O2 are independent. In binary mixtures of these two gases, however, they are not independent; rather, molecular relaxation is known to be controlled by a very strong vibrational-vibrational (V-V) coupling, which influences both the relaxation frequencies and the relaxation strengths. This article shows that small concentrations of the air constituents CO2 and H2O, which themselves possess a strong V-V coupling to N2 and O2, serve to decouple the N2 and O2 relaxations. To characterize the N2-O2 coupling a coupling strength is derived which depends upon the constituent concentrations and the related reaction rate constants. It is found that the molecular relaxations associated with N2 and O2 in air experience a gradual transition from strong to weak coupling as the humidity increases beyond approximately 0.001 mole percent.

Zuckerwar, Allan J.↗

Development of an advanced solid amine humidity and CO2 control system for potential Space Station Extravehicular Activity application

A system for removing metabolic carbon dioxide and water vapor from breathing air within a space suit during NASA Space Station EVA is discussed. The solid amine compound used is packed within a water-cooled metal foam matrix heat-exchanger to remove the exothermic heat of chemical reaction. Details of the design of a canister for humidity and carbon dioxide control and performance of the system are presented.

Nalette, Timothy A.↗