Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Imaging arrangement and microscope

An embodiment of the present invention is an imaging arrangement that includes imaging optics, a fiducial light source, and a control system. In operation, the imaging optics separate light into first and second tight by wavelength and project the first and second light onto first and second areas within first and second detector regions, respectively. The imaging optics separate fiducial light from the fiducial light source into first and second fiducial light and project the first and second fiducial light onto third and fourth areas within the first and second detector regions, respectively. The control system adjusts alignment of the imaging optics so that the first and second fiducial light projected onto the first and second detector regions maintain relatively constant positions within the first and second detector regions, respectively. Another embodiment of the present invention is a microscope that includes the imaging arrangement.

42 ENGINEERING↗

Non parametric denoising methods based on wavelets: Application to electron microscopy images in low exposure time

The 3D reconstruction of the Cryo-Transmission Electron Microscopy (Cryo-TEM) and Energy Filtering TEM images (EFTEM) hampered by the noisy nature of these images, so that their alignment becomes so difficult. This noise refers to the collision between the frozen hydrated biological samples and the electrons beam, where the specimen is exposed to the radiation with a high exposure time. This sensitivity to the electrons beam led specialists to obtain the specimen projection images at very low exposure time, which resulting the emergence of a new problem, an extremely low signal-to-noise ratio (SNR). This paper investigates the problem of TEM images denoising when they are acquired at very low exposure time. So, our main objective is to enhance the quality of TEM images to improve the alignment process which will in turn improve the three dimensional tomography reconstructions. We have done multiple tests on special TEM images acquired at different exposure time 0.5s, 0.2s, 0.1s and 1s (i.e. with different values of SNR)) and equipped by Golding beads for helping us in the assessment step. We herein, propose a structure to combine multiple noisy copies of the TEM images. The structure is based on four different denoising methods, to combine the multiple noisy TEM images copies. Namely, the four different methods are Soft, the Hard as Wavelet-Thresholding methods, Bilateral Filter as a non-linear technique able to maintain the edges neatly, and the Bayesian approach in the wavelet domain, in which context modeling is used to estimate the parameter for each coefficient. To ensure getting a high signal-to-noise ratio, we have guaranteed that we are using the appropriate wavelet family at the appropriate level. So we have chosen âĂIJsym8âĂİ wavelet at level 3 as the most appropriate parameter. Whereas, for the bilateral filtering many tests are done in order to determine the proper filter parameters represented by the size of the filter, the range parameter and the spatial parameter respectively. The experiments reported in this paper demonstrate the performance of the Bilateral Filtering and the Bayesian approaches in terms of improving the SNRout and the image quality. Taken together, these results suggest that the Bayesian process has a potential to outperform all the used methods, where in the multiple noisy copies structure it gave us the best SNRout without change of the golden beads diameter. The Bayesian approach yielded enhanced average image without needing a huge amount of copies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fine alignment of a large segmented mirror

A system for aligning a segmented mirror includes a source of radiation directed along a first axis to the segmented mirror and a beamsplitter removably inserted along the first axis for redirecting radiation from the first axis to a second axis, substantially perpendicular to the first axis. An imaging array is positioned along the second axis for imaging the redirected radiation, and a knife-edge configured for cutting the redirected radiation is serially positioned to occlude and not occlude the redirected radiation, effectively providing a variable radiation pattern detected by the imaging array for aligning the segmented mirror.

Dey, Thomas William↗

TU-C-12A-02: Development of a Multiparametric Statistical Response Map for Quantitative Imaging

Purpose: Quantitative imaging biomarkers (QIB) are becoming increasingly utilized in early phase clinical trials as a means of non-invasively assessing treatment response and associated response heterogeneity. The aim of this study was to develop a flexible multiparametric statistical framework to predict voxel-by-voxel response of several potential MRI QIBs. Methods: Patients with histologically proven glioblastomas (n=11) were treated with chemoradiation (with/without bevacizumab) and underwent one baseline and two mid-treatment (3–4wks) MRIs. Dynamic contrast-enhanced (3D FSPGR, 6.3sec/phase, 0.1 mmol/kg Gd-DTPA), dynamic susceptibility contrast (2D GRE-EPI, 1.5sec/phase, 0.2mmol/kg Gd-DTPA), and diffusion tensor (2D DW-EPI, b=0, 1200 s/mm{sup 2}, 27 directions) imaging acquisitions were obtained during each study. Mid-treatment and pre-treatment images were rigidly aligned, and regions of partial response (PR), stable disease (SD), and progressive disease (PD) were contoured in consensus by two experienced radiation oncologists. Voxels in these categories were used to train ordinal (PR<SD<PD) and logistic (PR/SD<PD) models incorporating the apparent diffusion coefficient, fractional anisotropy, Ktrans, ve, vp, and relative cerebral blood volume imaging biomarkers, as well as treatment type. Leave-one-out cross-validation was performed at the patient level to assess model prediction accuracy. Results: Ordinal regression resulted in model prediction accuracies of 60% (PR), 0% (SD), 81% (PD), and 69% (overall), with coefficients of variation (COV) of 9.4%, 9.6%, and 23.6%, respectively. Logistic regression resulted in accuracies of 82.0% (PR/SD), 46.2% (PD), and 76.2% (overall) with COVs of 22.4%, 45.7%, and 23.8%, respectively. Conclusion: Despite limited patient numbers, this feasibility pilot study demonstrates that ordinal and logistic regression models potentially provide a flexible statistical framework for incorporating longitudinal multiparametric quantitative imaging data and, for these particular data, can potentially distinguish PR from PD. Additional training data exhibiting a full range of treatment responses is expected to allow prediction of all three treatment outcomes. Moreover, these models are extensible to multi-modality, multiparametric analyses.

60 APPLIED LIFE SCIENCES↗

Mapping by VESGEN of Blood Vessels in the Retinas of Astronauts Pre- and Post-Flight to the ISS

Research by NASA [1] established that significant risks for visual and ocular impairments associated with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions. It is well established in physiology and pathology that a fundamental role of the microvasculature is to mediate fluid transfers and remodel actively in response to environmental, immune and other stresses. We therefore hypothesize that remodeling of retinal blood vessels necessarily occurs during accommodation of microgravity-induced fluid shifts prior to subsequent development of visual and ocular impairments. Potential contributions of retinal vascular remodeling to VIIP etiology are therefore being investigated by NASA's innovative VESsel GENeration Analysis (VESGEN) software for two studies: (1) U.S. crew members before and after ISS missions, and (2) head-down tilt in human subjects before and after 70 days of bed rest. We anticipate that results of the two studies will be complete by the Investigators Workshop (January 22, 2017). METHODS: For the 2013 NASA NRA award, we are concluding the analysis of 30 degree infrared (IR) Heidelberg Spectralis images of retinal blood vessels by VESGEN (patents pending), a mature, automated software developed as a translational and basic vascular research discovery tool, particularly for retinal vascular disease. Subjects of our retrospective study include eight ISS crew members monitored for routine occupational surveillance pre- and post-flight, who provided their study consents to NASAs Lifetime Surveillance of Astronaut Health (LSAH) in coordination with approval of the VESGEN retrospective study protocol by NASAs Institutional Review Board (IRB). The ophthalmic retinal images (average image resolution, approximately 5.6 microns per pixel) are blinded as to pre and post ISS status until the second portion of our study, when VESGEN results will be correlated with other ophthalmic and medical findings for the crew members. Due to image resolution challenges, a novel Matlab tool was developed for aligning pre and post images, and comparing (querying) the two images for differences in the morphology of small vessels. RESULTS: During the past year, LSAH approved the release of all astronaut retinal images to our study for VESGEN analysis. Substantial progress on the initial blinded portion of the study is in place. We anticipate that VESGEN analysis of the 32 Spectralis IR retinal images will be complete for presentation at the 2017 IWS meeting. CONCLUSIONS: Modified retinal vascular patterning may offer early-stage predictions of ocular changes resulting in decreased visual acuity for the VIIP syndrome. Novel insights provided by VESGEN into progressively pathological and blinding vascular remodeling in the human retina currently help to guide other NIH- and NASA-supported therapeutic studies of retinal disease and modeling of the VIIP risk. Results of our vascular investigation of the retinas of astronauts pre- and post-flight may help advance the understanding of both healthy and pathological adaptations to fluid shifts in microgravity associated with the VIIP syndrome. Preliminary results indicate that imaging of higher resolution, such as the new OCT angiography (OCT-A) technology, will be required to determine conclusively the role of the smaller retinal and choroidal vessels in VIIP etiology.

VESGEN↗

SU-E-J-08: A Hybrid Three Dimensional Registration Framework for Image-Guided Accurate Radiotherapy System ARTS-IGRT

Purpose: The purpose of this work was to develop a registration framework and method based on the software platform of ARTS-IGRT and implement in C++ based on ITK libraries to register CT images and CBCT images. ARTS-IGRT was a part of our self-developed accurate radiation planning system ARTS. Methods: Mutual information (MI) registration treated each voxel equally. Actually, different voxels even having same intensity should be treated differently in the registration procedure. According to their importance values calculated from self-information, a similarity measure was proposed which combined the spatial importance of a voxel with MI (S-MI). For lung registration, Firstly, a global alignment method was adopted to minimize the margin error and achieve the alignment of these two images on the whole. The result obtained at the low resolution level was then interpolated to become the initial conditions for the higher resolution computation. Secondly, a new similarity measurement S-MI was established to quantify how close the two input image volumes were to each other. Finally, Demons model was applied to compute the deformable map. Results: Registration tools were tested for head-neck and lung images and the average region was 128*128*49. The rigid registration took approximately 2 min and converged 10% faster than traditional MI algorithm, the accuracy reached 1mm for head-neck images. For lung images, the improved symmetric Demons registration process was completed in an average of 5 min using a 2.4GHz dual core CPU. Conclusion: A registration framework was developed to correct patient's setup according to register the planning CT volume data and the daily reconstructed 3D CBCT data. The experiments showed that the spatial MI algorithm can be adopted for head-neck images. The improved Demons deformable registration was more suitable to lung images, and rigid alignment should be applied before deformable registration to get more accurate result. Supported by National Natural Science Foundation of China (NO.81101132) and Natural Science Foundation of Anhui Province (NO.11040606Q55)

60 APPLIED LIFE SCIENCES↗

The Complex Spin State of 103P-Hartley 2: Kinematics and Orientation in Space

We derive the spin state of the nucleus of Comet 103P/Hartley 2, its orientation in space, and its short-term temporal evolution from a mixture of observations taken from the DIXI (Deep Impact Extended Investigation) spacecraft and radar observations. The nucleus is found to spin in an excited long-axis mode (LAM) with its rotational angular momentum per unit mass, M, and rotational energy per unit mass, E, slowly decreasing while the degree of excitation in the spin increases through perihelion passage. M is directed toward (RA, Dec; J2000) = 8+/-+/- 4 deg., 54 +/- 1 deg. (obliquity = 48 +/- 1 deg.). This direction is likely changing, but the change is probably <6 deg. on the sky over the approx. 81.6 days of the DIXI encounter. The magnitudes of M and E at closest approach (JD 2455505.0831866 2011-11-04 13:59:47.310) are 30.0 +/- 0.2 sq. m/s and (1.56 +/- 0.02) X 10(exp -3) sq. m /sq. s respectively. The period of rotation about the instantaneous spin vector, which points in the direction (RA, Dec; J2000) = 300 +/- 3.2deg., 67 +/- 1.3 deg. at the time of closest approach, was 14.1 +/- 0.3 h. The instantaneous spin vector circulates around M, inclined at an average angle of 33.2 +/- 1.3 deg. with an average period of 18.40 +/- 0.13 h at the time of closest approach. The period of roll around the principal axis of minimum inertia (''long'' axis) at that time is 26.72 +/- 0.06 h. The long axis is inclined to M by approx. 81.2 +/- 0.6 deg. on average, slowly decreasing through encounter. We infer that there is a periodic nodding motion of the long axis with half the roll period, i.e., 13.36+/- 0.03 h, with amplitude of 1 again decreasing through encounter. The periodic variability in the circulation and roll rates during a cycle was at the 2% and 10-14% level respectively. During the encounter there was a secular lengthening of the circulation period of the long axis by 1.3 +/- 0.2 min/d, in agreement with ground-based estimates, while the period of roll around the long axis changed by approx. -4.4 min/d at perihelion. M decreased at a rate of 0.038 (sq m/s) per day in a roughly linear fashion. Assuming a bulk density between 230-300 kg/m3 and a total volume for the nucleus of 8.09 X 10(exp 8) cubic m, the net torque acting on the nucleus was in the range 0.8-1.1 X 10(exp 5) kg m(exp 2) /s(exp 2). In order to bring the spacecraft photometric and imaging data into alignment on the direction of M, the directions of the intermediate and short principal axes of inertia had to be adjusted by 33 deg (on the sky) from the values indicated by the shape model with an assumed homogeneous interior. The adjusted direction of the intermediate axis is RA, Dec = 302 deg., -16.5 deg.. The morning and evening terminators in the images are identified, and the variation of the insolation at three regions on the nucleus associated with active areas calculated. The plume of water vapor observed in the inner coma is found to be directed close to the direction of local gravity over the sub-solar region for a range of reasonable bulk densities. The plume does not follow the projected normal to the surface at the sub-solar point.

Comets↗

Multiple Radially Aligned Plasmaspheric Structures as Evidence of Standing Hydromagnetic Waves: IMAGE EUV Observations and Forward Modeling

The IMAGE EUV imager has observed several instances where the outer plasmasphere is populated by multiple radially aligned structures resembling "plasmaspheric fingers". The observation of these plasmaspheric structures suggests the presence of an azimuthal standing hydromagnetic wave mode. Eiganmodes appear to explain finger-like. nearly radial density structures that sometimes divide into two structures with increasing radial distance. The implication is of boundaries at fixed local times, which results in a widening "box" in which standing waves are developed. The structures also suggest a single driving frequency for the source of the waves. We present EUV observations of plasmaspheric fingers observed on August 2000 as well as plasmaspheric modeling of azimuthal wave modes in an effort to quantify the origin of these observed structures

Gallagher, D. L.↗

SU-F-T-634: Feasibility Study of Respiratory Gated RapidArc SBRT Using a 6MV FFF Photon Beam

Purpose: To conduct a feasibility study on retrospective respiratory gating and marker tracking for lung stereotactic body radiotherapy (SBRT) with a gated RapidArc delivery using a 6MV flattened filter free photon mode. Methods: A CIRS dynamic thorax phantom Model 008A with different inserts was used for treatment planning and respiratory gating. 4D CT had a free breathing simulation followed by a respiration gated, ten phased CT using a Philips Brilliance CT with a Varian RPM respiratory gating system. The internal target volume was created from the ten phase gated CT images, followed by exporting to a Varian Eclipse TPS v11 for treatment planning on the free breath images. Both MIP and AIP were also generated for comparison of planning and target motion tracking. The planned dose was delivered with a 6MV FFF photon beam from a Varian TrueBeam accelerator. Gated target motion was also verified by tracking the implanted makers during delivery using continuous kV imaging in addition to CBCT, kV and MV localization and verification. Results: Gating was studied in three situations of lower, normal, and faster breathing at a respiratory cycle of 5, 15 and 25 breaths per minute, respectively. 4D treatment planning was performed at a normal breathing of 15 breaths per minute. The gated patterns obtained using the TrueBeam IR camera were compared with the planned ones while gating operation was added prior to delivery . Gating was realized only when the measured respiratory patterns matched to the planned ones. The gated target motion was verified within the tolerance by kV and MV imaging. Either free breathing CT or averaged CT images were studied to be good for image guidance to align the target. Conclusion: Gated RapidArc SBRT delivered with a 6MV FFF photon beam is realized using a dynamic lung phantom.

60 APPLIED LIFE SCIENCES↗

Development of Software to Model AXAF-I Image Quality

This draft final report describes the work performed under the delivery order number 145 from May 1995 through August 1996. The scope of work included a number of software development tasks for the performance modeling of AXAF-I. A number of new capabilities and functions have been added to the GT software, which is the command mode version of the GRAZTRACE software, originally developed by MSFC. A structural data interface has been developed for the EAL (old SPAR) finite element analysis FEA program, which is being used by MSFC Structural Analysis group for the analysis of AXAF-I. This interface utility can read the structural deformation file from the EAL and other finite element analysis programs such as NASTRAN and COSMOS/M, and convert the data to a suitable format that can be used for the deformation ray-tracing to predict the image quality for a distorted mirror. There is a provision in this utility to expand the data from finite element models assuming 180 degrees symmetry. This utility has been used to predict image characteristics for the AXAF-I HRMA, when subjected to gravity effects in the horizontal x-ray ground test configuration. The development of the metrology data processing interface software has also been completed. It can read the HDOS FITS format surface map files, manipulate and filter the metrology data, and produce a deformation file, which can be used by GT for ray tracing for the mirror surface figure errors. This utility has been used to determine the optimum alignment (axial spacing and clocking) for the four pairs of AXAF-I mirrors. Based on this optimized alignment, the geometric images and effective focal lengths for the as built mirrors were predicted to cross check the results obtained by Kodak.

Ahmad, Anees↗

Low-complexity atlas-based prostate segmentation by combining global, regional, and local metrics

Purpose: To improve the efficiency of atlas-based segmentation without compromising accuracy, and to demonstrate the validity of the proposed method on MRI-based prostate segmentation application. Methods: Accurate and efficient automatic structure segmentation is an important task in medical image processing. Atlas-based methods, as the state-of-the-art, provide good segmentation at the cost of a large number of computationally intensive nonrigid registrations, for anatomical sites/structures that are subject to deformation. In this study, the authors propose to utilize a combination of global, regional, and local metrics to improve the accuracy yet significantly reduce the number of required nonrigid registrations. The authors first perform an affine registration to minimize the global mean squared error (gMSE) to coarsely align each atlas image to the target. Subsequently, atarget-specific regional MSE (rMSE), demonstrated to be a good surrogate for dice similarity coefficient (DSC), is used to select a relevant subset from the training atlas. Only within this subset are nonrigid registrations performed between the training images and the target image, to minimize a weighted combination of gMSE and rMSE. Finally, structure labels are propagated from the selected training samples to the target via the estimated deformation fields, and label fusion is performed based on a weighted combination of rMSE and local MSE (lMSE) discrepancy, with proper total-variation-based spatial regularization. Results: The proposed method was applied to a public database of 30 prostate MR images with expert-segmented structures. The authors’ method, utilizing only eight nonrigid registrations, achieved a performance with a median/mean DSC of over 0.87/0.86, outperforming the state-of-the-art full-fledged atlas-based segmentation approach of which the median/mean DSC was 0.84/0.82 when applying to their data set. Conclusions: The proposed method requires a fixed number of nonrigid registrations, independent of atlas size, providing desirable scalability especially important for a large or growing atlas. When applied to prostate segmentation, the method achieved better performance to the state-of-the-art atlas-based approaches, with significant improvement in computation efficiency. The proposed rationale of utilizing jointly global, regional, and local metrics, based on the information characteristic and surrogate behavior for registration and fusion subtasks, can be extended naturally to similarity metrics beyond MSE, such as correlation or mutual information types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

60 APPLIED LIFE SCIENCES↗

Rapid alignment of nanotomography data using joint iterative reconstruction and reprojection

As x-ray and electron tomography is pushed farther into the nanoscale, the limitations of rotation stages become more apparent leading to challenges in the alignment of the acquired projection images. Here we present an approach for rapid post-acquisition alignment of these projections to obtain high quality 3D images. Our approach is based on a joint estimation of alignment errors, and the object, using an iterative refinement procedure. We characterize convergence in simulations, and show its application in x-ray and electron nanotomography.

47 OTHER INSTRUMENTATION↗

X-ray imaging of a filament eruption with the Solar Maximum Mission satellite

Soft X-ray observations of a filament located near NOAA AR 4640 were obtained with the Flat Crystal Spectrometer (FCS) on board the Solar Maximum Mission satellite on April 3-12, 1985. On April 7 the filament partially lifted off. At the same time and location an enhancement was imaged in soft X-rays. A total of 16 h of FCS observations, including 25 raster images, were made of the filament prior to the eruption, and over 40 h of observations, including 57 raster images, were made following the eruption. Careful alignment of H-alpha images taken during the same period has made possible the calculation of the integrated soft X-ray emission around the filament channel before, during, and after the eruption. Kitt Peak magnetograms have also been examined for this period to determine the corresponding magnetic field structure. A time history of the eruption in X-ray and optical wavelengths, and the development of the magnetic-field structure are presented. Evidence is seen for X-ray brightening in preexisting magnetic-field loops over the filament.

Slater, G. L.↗

WE-AB-BRA-07: Quantitative Evaluation of 2D-2D and 2D-3D Image Guided Radiation Therapy for Clinical Trial Credentialing, NRG Oncology/RTOG

Purpose: 2D-2D kV image guided radiation therapy (IGRT) credentialing evaluation for clinical trial qualification was historically qualitative through submitting screen captures of the fusion process. However, as quantitative DICOM 2D-2D and 2D-3D image registration tools are implemented in clinical practice for better precision, especially in centers that treat patients with protons, better IGRT credentialing techniques are needed. The aim of this work is to establish methodologies for quantitatively reviewing IGRT submissions based on DICOM 2D-2D and 2D-3D image registration and to test the methodologies in reviewing 2D-2D and 2D-3D IGRT submissions for RTOG/NRG Oncology clinical trials qualifications. Methods: DICOM 2D-2D and 2D-3D automated and manual image registration have been tested using the Harmony tool in MIM software. 2D kV orthogonal portal images are fused with the reference digital reconstructed radiographs (DRR) in the 2D-2D registration while the 2D portal images are fused with DICOM planning CT image in the 2D-3D registration. The Harmony tool allows alignment of the two images used in the registration process and also calculates the required shifts. Shifts calculated using MIM are compared with those submitted by institutions for IGRT credentialing. Reported shifts are considered to be acceptable if differences are less than 3mm. Results: Several tests have been performed on the 2D-2D and 2D-3D registration. The results indicated good agreement between submitted and calculated shifts. A workflow for reviewing these IGRT submissions has been developed and will eventually be used to review IGRT submissions. Conclusion: The IROC Philadelphia RTQA center has developed and tested a new workflow for reviewing DICOM 2D-2D and 2D-3D IGRT credentialing submissions made by different cancer clinical centers, especially proton centers. NRG Center for Innovation in Radiation Oncology (CIRO) and IROC RTQA center continue their collaborative efforts to enhance quality assurance services and to be consistently adaptive to the new advances in radiation therapy. This project was supported by NCI grants U10CA180868, U10CA180822, U24CA180803, U24CA12014 and PA CURE Grant.

60 APPLIED LIFE SCIENCES↗

Deep narrow band imagery of the diffuse ISM in M33

Very deep narrow band images were obtained for several fields in the local group spiral galaxy M33 using a wide field reimaging Charge Coupled Device (CCD) camera on the 1.5 m telescope at Palomar Observatory. The reimaging system uses a 306 mm collimator and a 58 mm camera lens to put a 16 minute by 16 minute field onto a Texas Instruments 800 x 800 pixel CCD at a resolution of 1.2 arcseconds pixel (-1). The overall system is f/1.65. Images were obtained in the light of H alpha (S II) lambda lambda 6717, 6731, (O III) lambda 5007, and line-free continuum bands 100A wide, centered at 6450A and 5100A. Assuming a distance of 600 kpc to M33 (Humphreys 1980, Ap. J., 241, 587), this corresponds to a linear scale of 3.5 pc pixel (-1), and a field size of 2.8 kpc x 2.8 kpc. Researchers discuss the H alpha imagery of a field centered approx. equal to 8 minutes NE of the nucleus, including the supergiant HII region complex NGC 604. Two 2000 second H alpha images and two 300 second red continuum images were obtained of two slightly offset fields. The fields were offset to allow for discrimination between real emission and possible artifacts in the images. All images were resampled to align them with one of the H alpha frames. The continuum images were normalized to the line images using the results of aperture photometry on a grid of stars in the field, then the rescaled continuum data were directly subtracted from the line data.

Hester, J. Jeff↗

Micro-beam Laue alignment of multi-reflection Bragg coherent diffraction imaging measurements

Multi-reflection Bragg coherent diffraction imaging has the potential to allow three-dimensional (3D) resolved measurements of the full lattice strain tensor in specific micro-crystals. Until now such measurements were hampered by the need for laborious, time-intensive alignment procedures. Here, in this paper, a different approach is demonstrated, using micro-beam Laue X-ray diffraction to first determine the lattice orientation of the micro-crystal. This information is then used to rapidly align coherent diffraction measurements of three or more reflections from the crystal. Based on these, 3D strain and stress fields in the crystal are successfully determined. This approach is demonstrated on a focused ion beam milled micro-crystal from which six reflections could be measured. Since information from more than three independent reflections is available, the reliability of the phases retrieved from the coherent diffraction data can be assessed. Lastly, our results show that rapid, reliable 3D coherent diffraction measurements of the full lattice strain tensor in specific micro-crystals are now feasible and can be successfully carried out even in heavily distorted samples.

36 MATERIALS SCIENCE↗