Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTS, LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Definition of experiments and instruments for a communication/navigation research laboratory. Volume 4: Programmatics

Details are provided for scheduling, cost estimates, and support research and technology requirements for a space shuttle supported manned research laboratory to conduct selected communication and navigation experiments. A summary of the candidate program and its time phasing is included, as well as photographs of the 1/20 scale model of the shuttle supported Early Comm/Nav Research Lab showing the baseline, in-bay arrangement and the out-of-bay configuration.

Source record↗

Definition of experiments and instruments for a communication/navigation research laboratory. Volume 1: Executive summary

This study was undertaken to develop conceptual designs for a manned, space shuttle sortie mission laboratory capable of supporting a wide variety of experiments in conjunction with communications and navigation research. This space/laboratory would be one in which man may effectively increase experiment efficiency by certain observations, modifications, setup, calibration, and limited maintenance steps. In addition, man may monitor experiment progress and perform preliminary data evaluation to verify proper equipment functioning and may terminate or redirect experiments to obtain the most desirable end results. The flexibility and unique capabilities of man as an experimenter in such a laboratory will add greatly to the simplification of space experiments and this provides the basis for commonality in many of the supportive subsystems, thus reaping the benefits of reusability and reduced experiment costs. For Vol. 4, see N73-19268.

Source record↗

Instruction manual, Optical Effects Module, Model OEM

The Optical Effects Module Model OEM-1, a laboratory prototype instrument designed for the automated measurement of radiation transmission and scattering through optical samples, is described. The system comprises two main components: the Optical Effects Module Enclosure (OEME) and the Optical Effects Module Electronic Controller and Processor (OEMCP). The OEM is designed for operation in the near UV at approximately 2540A, corresponding to the most intense spectral line activated by the mercury discharge lamp used for illumination. The radiation from this source is detected in transmission and reflection through a number of selectable samples. The basic objective of this operation is to monitor in real time the accretion of possible contamination on the surface of these samples. The optical samples are exposed outside of the OEME proper to define exposure conditions and to separate exposure and measurement environments. Changes in the transmissivity of the sample are attributable to surface contamination or to bulk effects due to radiation. Surface contamination will increase radiation scattering due to Rayleigh-Gans effect or to other phenomena, depending on the characteristics size of the particulate contaminants. Thus, also scattering from the samples becomes a part of the measurement program.

Source record↗

Instrument development for a toxic level hypergolic vapor detector

The development and deployment of technology applicable to the field measurement of hypergolic propellants is discussed. The propellants include hydrazine (H) monomethylhydrazine (MMH), and 1,1-dimethylhydrazine (UDMH) at the parts per billion (PPB) level in air or a diluent gas. Four major areas are reviewed: (1) development of an improved electrochemical sensor for the measurement of hydrazines (H, MMH and UDMH) in air; (2) prototype instrument fabrication and subsequent laboratory evaluation; (3) initial instrument field test results; and (4) future requirements and applications.

Rogers, P. M.↗

Dynamic mechanical analysis and organization/storage of data for polymetric materials

Dynamic mechanical analysis was performed on a variety of temperature resistant polymers and composite resin matrices. Data on glass transition temperatures and degree of cure attained were derived. In addition a laboratory based computer system was installed and data base set up to allow entry of composite data. The laboratory CPU termed TYCHO is based on a DEC PDP 11/44 CPU with a Datatrieve relational data base. The function of TYCHO is integration of chemical laboratory analytical instrumentation and storage of chemical structures for modeling of new polymeric structures and compounds

Rosenberg, M.↗

Solar wind iron abundance variations at solar wind speeds up to 600 km s sup -1, 1972 to 1976

The Fe/H ratios in the peaks of high speed streams (HSS) were analyzed during the decline of Solar Cycle 20 and the following minimum (October 1972 to December 1976). The response of the 50 to 200 keV ion channel of the APL/JHU energetic particle experiment (EPE) on IMP-7 and 8 was utilized to solar wind iron ions at high solar wind speeds (V or = 600 km/sec). Fe measurements with solar wind H and He parameters were compared from the Los Alamos National Laboratory (LANL) instruments on the same spacecraft. In general, the Fe distribution parameters (bulk velocity, flow direction, temperature) are found to be similar to the LANL He parameters. Although the average Fe/H ration in many steady HSS peaks agrees within observational uncertainties with the nominal coronal ratio of 4.7 x 0.00001, abundance variations of a factor of up to 6 are obtained across a given coronal-hole associated HSS.

Mitchell, D. G.↗

Spatial variation of iron abundance in the high speed solar wind, 1972 to 1976

The Fe/H ratios in the peaks of high speed streams (HSS) during the decline of Solar Cycle 20 and the following minimum (October 1972-December 1976) were analyzed. The response of the 50-200 keV ion channel of the APL/JHU energetic particle experiment (EPE) on IMP-7 and 8 to solar wind iron ions at high solar wind speeds and Fe measurements were compared with solar wind H and He parameters from the Los Alamos National Laboratory (LANL) instruments on the same spacecraft. In general, the Fe distribution parameters (bulk velocity, flow direction, temperature) are found to be similar to the LANL He parameters. Although the average Fe/H ratio in many steady HSS peaks agrees within observational uncertainties with the nominal coronal ratio of 4.7 x 10(-5), abundance variations of a factor of up to 6 are obtained across a given coronal-hole associated HSS. Over the period 1973-1976, a steady decrease in the average quiet-time Fe/H ratio by a factor of about 4 is measured on both IMP-7 and 8.

Mitchell, D. G.↗

A water-vapor radiometer error model

The water-vapor radiometer (WVR) is used to calibrate unpredictable delays in the wet component of the troposphere in geodetic microwave techniques such as very-long-baseline interferometry (VLBI) and Global Positioning System (GPS) tracking. Based on experience with Jet Propulsion Laboratory (JPL) instruments, the current level of accuracy in wet-troposphere calibration limits the accuracy of local vertical measurements to 5-10 cm. The goal for the near future is 1-3 cm. Although the WVR is currently the best calibration method, many instruments are prone to systematic error. In this paper, a treatment of WVR data is proposed and evaluated. This treatment reduces the effect of WVR systematic errors by estimating parameters that specify an assumed functional form for the error. The assumed form of the treatment is evaluated by comparing the results of two similar WVR's operating near each other. Finally, the observability of the error parameters is estimated by covariance analysis.

Beckman, B.↗

A portable spectrometer for use from 5 to 15 micrometers

A field portable spectrometer suitable for collecting data relevant to remote sensing applications in the 8 to 12 micrometer atmospheric window has been built at the Jet Propulsion Laboratory. The instrument employs a single cooled HgCdTe detector and a continuously variable filter wheel analyzer. The spectral range covered is 5 to 14.5 micrometers and the resolution is approximately 1.5 percent of the wavelength. A description of the hardware is followed by a discussion of the analysis of the spectral data leading to finished emissivity and radiance spectra. A section is devoted to the evaluation of the instrument performance with respect to spectral resolution, radiometric precision, and accuracy. Several examples of spectra acquired in the field are included.

Hoover, G.↗

New high-resolution electrostatic ion mass analyzer using time of flight

The design of a high-resolution ion-mass analyzer is described, which is based on an accurate measurement of the time of flight (TOF) of ions within a region configured to produce a harmonic potential. In this device, the TOF, which is independent of ion energy, is determined from a start pulse from secondary electrons produced when the ion passes through a thin carbon foil at the entrance of the TOF region and at a stop pulse from the ion striking a microchannel plate upon exciting the region. A laboratory prototype instrument called 'VMASS' was built and was tested at the Goddard Space Flight Center electrostatic accelerator, showing a good mass resolution of the instrument. Sensors of the VMASS type will form part of the WIND Solar Wind and Suprathermal Ion experiment, the Soho mission, and the Advanced Composition Explorer.

Hamilton, D. C.↗

A Miniature Electrical Pressure Gage Utilizing a Stretched Flat Diagram

A variable-air-gap, inductance-type, electrical pressure gage is described that is basically 7/16 inch in diameter and 1/4 inch in thickness. The gage was designed to measure accurately pressures fluctuating at high frequencies and has proved to be a value as a general-purpose electrical gage for aeronautical work where small size and minimum response to acceleration forces are important factors. Design equations and curves are presented which can be used to predict the deflections and fundamental natural frequencies of stretched flat diaphragms.

INSTRUMENTS, LABORATORY↗

A Specially Constructed Metallograph for Use at Elevated Temperatures

A Metallographic microscope was developed with provision for heating a specimen to 1800 F in protective atmospheres, that is, vacuum or gas. A special objective was constructed of reflecting elements with an unusually long working distance (7/16 in.) and a high numerical aperture (0.5). Changes in specimen microstructure were observed and recorded on 35-millimeter motion-picture film. The resulting pictures were projected as motion pictures and individual frames were cut and enlargements made for close observation. Structural changes upon heating a 0.35-percent annealed carbon steel and a 5-percent tin phosphor bronze specimen were observed and recorded. Newly formed microstructure were revealed by selective vacuum etching and specimen relief resulting from recrystallization and varying grain orientation.

INSTRUMENTS, LABORATORY↗

A Multiple-range Self-balancing Thermocouple Potentiometer

A multiple-range potentiometer circuit is described that provides automatic measurement of temperatures or temperature differences with any one of several thermocouple-material pairs. Techniques of automatic reference junction compensation, span adjustment, and zero suppression are described that permit rapid selection of range and wire material, without the necessity for restandardization, by setting of two external tap switches.

INSTRUMENTS, LABORATORY↗

Optical Design of the MOSES Sounding Rocket Experiment

The Multi-Order Solar EUV Spectrograph (MOSES) is a sounding rocket payload now being developed by Montana State University in collaboration with the Goddard Space Flight Center, Lockheed Martin Advanced Technology Center, and Mullard Space Science Laboratory. The instrument utilizes a unique optical design to provide solar EUV measurements with true 2-pixel resolutions of 1.0 arcsec and 60 mA over a full two-dimensional field of view of 1056 x 528 arcsec, all at a time cadence of 10 s. This unprecedented capability is achieved by means of an objective spherical grating 100 mm in diameter, ruled at 833 gr/mm. The concave grating focuses spectrally dispersed solar radiation onto three separate detectors, simultaneously recording the zero-order as well as the plus and minus first-spectral-order images. Data analysis procedures, similar to those used in X-ray tomography reconstructions, can then disentangle the mixed spatial and spectral information recorded by the multiple detectors. A flat folding mirror permits an imaging focal length of 4.74 m to be packaged within the payload's physical length of 2.82 m. Both the objective grating and folding flat have specialized, closely matched, multilayer coatings that strongly enhance their EUV reflectance while also suppressing off-band radiation that would otherwise complicate data inversion. Although the spectral bandpass is rather narrow, several candidate wavelength intervals are available to carry out truly unique scientific studies of the outer solar atmosphere. Initial flights of MOSES, scheduled to begin in 2004, will observe a 10 Angstrom band that covers very strong emission lines characteristic of both the sun's corona (Si XI 303 Angstroms) and transition-region (He II 304 Angstroms). The MOSES program is supported by a grant from NASA's Office of Space Science.

Thomas, Roger J.↗

Fiducial Marks for Location of Particles in Aerogel

If an extraterrestrial sample is captured in aerogel as a collection of particles, it is important to be able to consistently locate individual grains when changing instruments or laboratories. We report on a feasibility study for applying fiducial marks to aerogel nondestructively so that the marks can eventually be used with optical, X-ray or other (manual or automated) location techniques.

Jurewicz, A. J. G.↗

Hummingbird Comet Nucleus Analysis Mission

Hummingbird is a highly focused scientific mission, proposed to NASA s Discovery Program, designed to address the highest priority questions in cometary science-that of the chemical composition of the cometary nucleus. After rendezvous with the comet, Hummingbird would first methodically image and map the comet, then collect and analyze dust, ice and gases from the cometary atmosphere to enrich characterization of the comet and support landing site selection. Then, like its namesake, Hummingbird would carefully descend to a pre-selected surface site obtaining a high-resolution image, gather a surface material sample, acquire surface temperature and then immediately return to orbit for detailed chemical and elemental analyses followed by a high resolution post-sampling image of the site. Hummingbird s analytical laboratory contains instrumentation for a comprehensive molecular and elemental analysis of the cometary nucleus as well as an innovative surface sample acquisition device.

Kojiro, Daniel↗