Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERLOCKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, an aluminum cryostat, an aluminum target vessel shielded with {sup 6}Li-rich plastic, a hydrogen fill/vent line with a passive recirculation loop to establish and maintain the equilibrium ortho-para ratio, a hydrogen relief system coupled to a vent stack, a gas handling system, and an alarm and interlock system. Low Z, nonmagnetic materials were used for the target vessel and cryostat. Pressure and temperature sensors monitored the thermodynamic state of the target. Relative neutron transmission measurements were used to monitor the parahydrogen fraction of the target. The target was thoroughly tested and successfully operated during the first phase of the NPDGamma experiment conducted at the FP12 beam line at Los Alamos Neutron Science Center (LANSCE). An upgraded version of the target system will be used in the next stage of the experiment, which will be performed at the Fundamental Neutron Physics Beam (FnPB) line of the Spallation Neutron Source at Oak Ridge National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tangled Up in Knots: Structures of Inactivated Forms of E. coli Class Ia Ribonucleotide Reductase

Ribonucleotide reductases (RNRs) provide the precursors for DNA biosynthesis and repair and are successful targets for anticancer drugs such as clofarabine and gemcitabine. Recently, we reported that dATP inhibits E. coli class Ia RNR by driving formation of RNR subunits into {alpha}{sub 4}{beta}{sub 4} rings. Here, we present the first X-ray structure of a gemcitabine-inhibited E. coli RNR and show that the previously described {alpha}{sub 4}{beta}{sub 4} rings can interlock to form an unprecedented ({alpha}{sub 4}{beta}{sub 4}){sub 2} megacomplex. This complex is also seen in a higher-resolution dATP-inhibited RNR structure presented here, which employs a distinct crystal lattice from that observed in the gemcitabine-inhibited case. With few reported examples of protein catenanes, we use data from small-angle X-ray scattering and electron microscopy to both understand the solution conditions that contribute to concatenation in RNRs as well as present a mechanism for the formation of these unusual structures.

59 BASIC BIOLOGICAL SCIENCES↗

Structural Basis for Autoregulation of the Zinc Transporter YiiP

Zinc transporters have crucial roles in cellular zinc homeostatic control. The 2.9-A resolution structure of the zinc transporter YiiP from Escherichia coli reveals a richly charged dimer interface stabilized by zinc binding. Site-directed fluorescence resonance energy transfer (FRET) measurements and mutation-activity analysis suggest that zinc binding triggers hinge movements of two electrically repulsive cytoplasmic domains pivoting around four salt bridges situated at the juncture of the cytoplasmic and transmembrane domains. These highly conserved salt bridges interlock transmembrane helices at the dimer interface, where they are well positioned to transmit zinc-induced interdomain movements to reorient transmembrane helices, thereby modulating coordination geometry of the active site for zinc transport. The cytoplasmic domain of YiiP is a structural mimic of metal-trafficking proteins and the metal-binding domains of metal-transporting P-type ATPases. The use of this common structural module to regulate metal coordination chemistry may enable a tunable transport activity in response to cytoplasmic metal fluctuations.

59 BASIC BIOLOGICAL SCIENCES↗

A control system of a negative hydrogen ion sources by using an EPICS-based proportional-integral-derivative

We have developed an EPICS-based control system for a multicusp negative ion source based on a VME IOC software, a sequencer controlling a closed proportional integral (PI) loop, and an interlock. The PI loop was tuned by a step input voltage, and tuning gains of the proportion and integral have been determined. The PI logics, developed by using standard proportional-integral-derivative records, can control the arc current within {+-}1% of a given set value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast triggers for a proton injector at PEFP

A fast timing system has been developed to control transistor transistor logic (TTL) trigger signals which are used to extract the pulsed proton beam from an ion source with the precision of less than submicro seconds. The system has been designed to set a delay and duty of the pulses, respectively, and prohibit the beam pulse by an external interlock signal. The system is based on VME which is composed of VME CPU and fast I/O boards with fan-out modules. The software of the system has been developed by the record/device supports and channel access in the core of the EPICS environments. In the paper, we describe software configurations and hardware drivers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study for 15-20 mA dc H{sup -} multicusp source

Recently, a new H- source and test stand was developed at CIAE. The design of this new source is based on the experience on our previous 10-15 mA H{sup -} ion source and the source at TRIUMF. Major efforts include the study of the virtual filter magnetic field, confining magnetic field, filament shape and location, the vacuum improvement on the extracting area, the extraction optics, new control and interlock system of the power supplies. More than 15 mA of H-beam was obtained for 36 h with stability of {+-}0.5%. The normalized emittance of 0.48{pi} mm mrad (4 rms normalized emittance) were measured with {approx}8 mA dc beam. Further experimental studies are proceeding in an effort to reach 20 mA with reasonable emittance at this moment. More study plans are conducted, e.g., building a longer source body and using cesium injection to get better emittance, which will be presented as a separate paper at this conference.

43 PARTICLE ACCELERATORS↗

Design of microcontroller based system for automation of streak camera

A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical detection of liquid lithium leaks from pipe joints

A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.

42 ENGINEERING↗

Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of EPICS based vacuum control system for variable energy cyclotron centre, Kolkata

The vacuum system of the Room Temperature (K = 130) Cyclotron of Variable Energy Cyclotron Centre is comprised of vacuum systems of main machine and Beam Transport System. The vacuum control system is upgraded to a PLC based Automated system from the initial relay based Manual system. The supervisory control of the vacuum system is implemented in Experimental Physics and Industrial Control System (EPICS). An EPICS embedded ARM based vacuum gauge controller is developed to mitigate the requirement of vendor specific gauge controller for gauges and also for seamless integration of the gauge controllers with the control system. A set of MS-Windows ActiveX components with embedded EPICS Channel Access interface are developed to build operator interfaces with less complex programming and to incorporate typical Windows feature, e.g., user authentication, file handling, better fonts, colors, mouse actions etc. into the operator interfaces. The control parameters, monitoring parameters, and system interlocks of the system are archived in MySQL based EPICS MySQL Archiver developed indigenously. In this paper, we describe the architecture, the implementation details, and the performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The COMPRES/GSECARS gas-loading system for diamond anvil cells at the Advanced Photon Source

We have designed and constructed a new system for loading gases at high pressure into diamond anvil cells at pressures up to 200 MPa. The gases are used either as quasi-hydrostatic pressure media surrounding the sample or as the sample itself. The diamond cell is sealed using a clamping mechanism, which permits nearly any type of diamond anvil cell to be used. Online ruby fluorescence and video imaging systems allow in situ monitoring of the pressure and gasket deformation as the cell is sealed, resulting in a very high success rate in loading cells. The system includes interlocks and computer control that allow it to be safely and easily operated by visiting users at the Advanced Photon Source. We present preliminary X-ray diffraction data on volume compression of single-crystal magnesium oxide (MgO) in helium up to 110 GPa.

43 PARTICLE ACCELERATORS↗

A robust and stable PLC based control system for 40kJ/25kV EMM system

This paper describes the PLC based control system developed for a 40kJ/25kV Electro-magnetic machining (EMM) system. In EMM system large capacitor banks is charged with high voltage to store large energy and the banks is made to discharge into a coil within few milli-seconds using a triggered spark gaps. During discharge of the capacitor large surges and transients are generated in the system. The control system monitors/controls and interlocks all the units of the system for proper operation. The control system is the only subsystem which is electrically connected to all the low and high voltage subsystems. Care should be taken at the signal interfacing with the control system to protect the control system. (author)

43 PARTICLE ACCELERATORS↗

Design of a Large 5 T Superconducting Magnet for Polarized Target for JLAB Hall B 12 GeV Upgrade Clas12 Detector

Hall B at Jefferson Laboratory (JLAB) will need a 5 T, 78 cm bore polarized target magnet with a field uniformity of {Delta}B/B{sub 0} <; 10{sup -4} in a useful cylinder of the dimensions 0.04 m long x 0.02 m in diameter. The large magnet is designed with a superconducting coil that provides the solenoid with nearly perfect self shielding in order to reduce the fringe field at nearby photo multiplier tubes (PMTs) to less than 3.5 mT. Because the solenoid is also very close to the Clas12 Torus, the nearly perfect shielding provided by the self shielded solenoid greatly reduces force, field, and torque interactions with the six-coil Torus magnet. The solenoid coil consists of 18 coil modules which are made of coils mounted in aluminum plate discs. Each coil module consists of dual double pancake coils with main coils and shield coil partitioned into separate winding cavities in the aluminum plate discs to distribute and reduce radial hoop load and radial coil forces. Each coil module is effectively an enclosed aluminum box and this serves to partition the axial load and thus reduces coil axial forces. Since overall coil forces within each coil module are reduced, this will greatly reduce the number coil training quenches. This is a very important consideration for this solenoid coil because the coil cooling is adiabatic, using in-direct conduction cooling by 4.5 K supercritical helium, which will provide only a relatively small temperature stability margin. Super critical helium is used as per JLAB specification. Detail design of the coil structure, coil assembly, cold mass, and cryogenic control will be presented. The magnet protection system shall be capable of the following features: (1) quench and fault detection, (2) fast discharge of the magnet, (3) limit fault voltages to safe values, (4) monitor interlock signals to prevent unsafe operation, and (5) provide control logic necessary for safe operation of the solenoid. The instrument systems shall be capable of the following features: (1) monitors and display temperatures within the solenoid magnet, (2) measure loads or stress on the magnet suspension, (3) monitor voltages within the solenoid magnet and charging bus, (4) monitor pressures and (5) use data logging system to save all sensor data. These systems will be described and a quench analysis presented.

43 PARTICLE ACCELERATORS↗

Investigation of Interfacial Layer for Friction Stir Scribe Welded Aluminum to Steel Joints

Friction stir scribe (FSS) welding as a recent derivative of friction stir welding has successfully fabricated a linear joint between automotive Al and steel sheets. However, there is a lack of understanding on its bonding mechanism. In this paper, the microstructures and phases at the bonding interface of FSS welded Al to ultra-high strength steel joints were studied using scanning electron microscopy and transmission electron microscopy. Based on the microstructural analysis, it is found that both mechanical and chemical bonding occurred simultaneously, and the energy-dispersive X-ray spectroscopy revealed that a thin intermetallic compound (IMC) layer was formed at the interface. Owing to the varied material flow and heat generation, the IMC layer thickness gradually decreased from the advancing side to the retreating side, and two IMCs (i.e. Fe2Al5 and Fe4Al13) were confirmed in different weld regions using diffraction pattern (or 1D fast Fourier transform pattern). Also, a Fe/Al solid solution was noticed in the IMC layer, and several Al fringes were found in the Fe-rich side in the scribe stir zone.

friction stir scribe welding, interfacial layer, i↗

"Defense-in-Depth" Laser Safety and the National Ignition Facility

The National Ignition Facility (NIF) is the largest and most energetic laser in the world contained in a complex the size of a football stadium. From the initial laser pulse, provided by telecommunication style infrared nanoJoule pulsed lasers, to the final 192 laser beams (1.8 Mega Joules total energy in the ultraviolet) converging on a target the size of a pencil eraser, laser safety is of paramount concern. In addition to this, there are numerous high-powered (Class 3B and 4) diagnostic lasers in use that can potentially send their laser radiation travelling throughout the facility. With individual beam paths of up to 1500 meters and a workforce of more than one thousand, the potential for exposure is significant. Simple laser safety practices utilized in typical laser labs just don't apply. To mitigate these hazards, NIF incorporates a multi layered approach to laser safety or 'Defense in Depth.' Most typical high-powered laser operations are contained and controlled within a single room using relatively simplistic controls to protect both the worker and the public. Laser workers are trained, use a standard operating procedure, and are required to wear Personal Protective Equipment (PPE) such as Laser Protective Eyewear (LPE) if the system is not fully enclosed. Non-workers are protected by means of posting the room with a warning sign and a flashing light. In the best of cases, a Safety Interlock System (SIS) will be employed which will 'safe' the laser in the case of unauthorized access. This type of laser operation is relatively easy to employ and manage. As the operation becomes more complex, higher levels of control are required to ensure personnel safety. Examples requiring enhanced controls are outdoor and multi-room laser operations. At the NIF there are 192 beam lines and numerous other Class 4 diagnostic lasers that can potentially deliver their hazardous energy to locations far from the laser source. This presents a serious and complex potential hazard to personnel. Because of this, a multilayered approach to safety is taken. This paper presents the philosophy and approach taken at the NIF in the multi-layered 'defense-in-depth' approach to laser safety.

42 ENGINEERING↗

Infrastructure Development of Single Cell Testing Capability at A0 Facility

The objective of this technical note is to document the details of the infrastructure development process that was realized at the A0 photo injector facility to establish RF cold testing capability for 1.3 GHz superconducting niobium single cell cavities. The activity began the last quarter of CY 2006 and ended the first quarter of CY 2009. The whole process involved addressing various aspects such as design of vertical insert and lifting fixture, modification of existing RF test station and design of new couplers, development of a Temperature Mapping (T-Map) system, radiation considerations for the test location (north cave), update of existing High Pressure Rinse (HPR) system, preparation of necessary safety documents and eventually obtaining an Operational Readiness Clearance (ORC). Figure 1 illustrates the various components of the development process. In the past, the north cave test station at A0 has supported the cold testing 3.9 GHz nine cell and single cell cavities, thus some of the components were available for use and some needed modification. The test dewar had the capacity to accommodate 1.3 GHz single cells although a new vertical insert that could handle both cavity types (1.3 and 3.9 GHz) had to be designed. The existing cryogenic system with an average capacity of {approx} 0.5 g/sec was deemed sufficient. The RF system was updated with broadband components and an additional amplifier with higher power capacity to handle higher gradients usually achieved in 1.3 GHz cavities. The initial testing phase was arbitrated to proceed with fixed power coupling. A new temperature mapping system was developed to provide the diagnostic tool for hot spot studies, quench characterization and field emission studies. The defining feature of this system was the use of diode sensors instead of the traditional carbon resistors as sensing elements. The unidirectional current carrying capacity (forward bias) of the diodes provided for the ease of multiplexing of the system, thus substantially reducing the number of cables required to power the sensors. The high gradient capacity of the 1.3 GHz cavities required a revision of the radiation shielding and interlocks. The cave was updated as per the recommendations of the radiation safety committee. The high pressure rinse system was updated with new adapters to assist the rinsing 1.3 GHz single cell cavities. Finally, a proposal for cold testing 1.3 GHz single cell cavities at A0 north cave was made to the small experiments approval committee, radiation safety committee and the Tevatron cryogenic safety sub-committee for an operational readiness clearance and the same was approved. The project was classified under research and development of single cell cavities (project 18) and was allocated a budget of $200,000 in FY 2007.

43 PARTICLE ACCELERATORS↗

DWPF Melter Off-Gas Flammability Assessment for Sludge Batch 9

The slurry feed to the Defense Waste Processing Facility (DWPF) melter contains several organic carbon species that decompose in the cold cap and produce flammable gases that could accumulate in the off-gas system and create potential flammability hazard. To mitigate such a hazard, DWPF has implemented a strategy to impose the Technical Safety Requirement (TSR) limits on all key operating variables affecting off-gas flammability and operate the melter within those limits using both hardwired/software interlocks and administrative controls. The operating variables that are currently being controlled include; (1) total organic carbon (TOC), (2) air purges for combustion and dilution, (3) melter vapor space temperature, and (4) feed rate. The safety basis limits for these operating variables are determined using two computer models, 4-stage cold cap and Melter Off-Gas (MOG) dynamics models, under the baseline upset scenario - a surge in off-gas flow due to the inherent cold cap instabilities in the slurry-fed melter.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commissioning report of the MuCool 5 Tesla solenoid coupled with helium refrigerator

MuCool 5T solenoid was successfully cooled down and operated coupled with MTA 'Brown' refrigerator. The system performed as designed with substantial performance margin. All process alarms and interlocks, as well as ODH and fire alarms, were active and performed as designed. The cooldown of the refrigerator started from warm conditions and took 44 hours to accumulate liquid helium level and solenoid temperature below 5K. Average liquid nitrogen consumption for the refrigerator precool and solenoid shield was measured as 20 gal/hr (including boil-off). Helium losses were small (below 30 scfh). The system was stable and with sufficient margin of performance and ran stably without wet expansion engine. Quench response demonstrated proper operation of the relieving devices and pointed to necessity of improving tightness of the relieving manifolds. Boil-off test demonstrated average heat load of 3 Watts for the unpowered solenoid. The solenoid can stay up to 48 hours cold and minimally filled if the nitrogen shield is maintained. A list of improvements includes commencing into operations the second helium compressor and completion of improvements and tune-ups for system efficiency.

43 PARTICLE ACCELERATORS↗