Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Ultrafast Laser Pulse Generation by Mode Locking: MATLAB-Based Demonstrations

Ultrafast laser spectroscopy is a valuable and increasingly accessible technique for studies of rapid chemical reactions. Critical to ultrafast spectroscopy is the concept of mode locking, a technique that enables a fixed phase relationship between laser modes, resulting in laser pulses with very short duration (in the fs or ps range). Despite the increasing importance of ultrafast lasers in chemistry, the introduction of key concepts behind their operation into the undergraduate and graduate chemistry coursework has been limited. To help the incorporation of these topics into chemistry courses, we report here a hands-on activity that helps students develop an intuitive understanding of the factors that impact electromagnetic wave evolution in optical cavities and the process of mode locking. We first provide the theoretical background by introducing cavity modes and contrasting them with well-known propagating electromagnetic waves. We then explore what happens when modes are added and how the relative phase between the modes affects their behavior. In the second section of this report, three teaching modules are provided, along with associated MATLAB codes and animated images, that can be used in the classroom to introduce concepts of cavity modes and mode locking. These teaching modules start by contrasting propagating electromagnetic waves with cavity modes and then illustrate what happens when multiple modes are present in the cavity and how the relative phase between the modes affects the overall electromagnetic field in the cavity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray microlaminography with polycapillary optics

We demonstrate layer-by-layer x-ray microimaging using polycapillary optics. The depth resolution is achieved without sample or source rotation and in a way similar to classical tomography or laminography. The method takes advantage from large angular apertures of polycapillary optics and from their specific microstructure, which is treated as a coded aperture. The imaging geometry is compatible with polychromatic x-ray sources and with scanning and confocal x-ray fluorescence setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing on green long persistent Eu{sup 2+}/Dy{sup 3+} doped Sr{sub 3}SiAl{sub 4}O{sub 11} emerging phosphor for security applications

Herein, a novel green emitting long-persistent Sr{sub 3}SiAl{sub 4}O{sub 11}:Eu{sup 2+}/Dy{sup 3+} phosphor was synthesized in a single phase form using facile solid state reaction method under the reducing atmosphere of 10% H{sub 2} and 90% N{sub 2}. The resulting phosphor exhibits hyper-sensitive strong broad green emission, peaking at 510 nm upon 340 nm excitation wavelength, which is attributed to the 4f{sup 6}5d{sup 1}-4f{sup 7} transitions of emission center of europium (Eu{sup 2+}) ions. Moreover, the incorporation of dysprosium (Dy{sup 3+}) ions, which act as effective hole trap centers with appropriate depth, largely enhances the photoluminescence characteristics and greatly improves the persistent intense luminescence behavior of Sr{sub 3}SiAl{sub 4}O{sub 11}:Eu{sup 2+}/Dy{sup 3+} phosphor under ultraviolet (UV) excitation. In addition, with the optimum doping concentration and sufficient UV excitation time period, the as-synthesized phosphor can be persisted afterglow for time duration ∼4 h with maximum luminescence intensity. Thus, these results suggest that this phosphor could be expected as an ultimate choice for next generation advanced luminescent materials in security applications such as latent finger-marks detection, photo-masking induced phosphorescent images, and security code detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MTIP Single Particle Imaging (Spinifel) v0.1.0

Performs Multi-Tiered Iterative Phasing for Single Particle Imaging. The Spinifel code uses distributed computing (using MPI and Legion) to spread work across many compute nodes. On-node computation is accelerated using GPGPUs (using CuPy, and CUDA).

Blaschke, Johannes↗

Experiments at Scale with In-Situ Visualization Using ParaView/Catalyst in RAGE

In this paper I describe some numerical experiments performed using the ParaView/Catalyst in-situ visualization infrastructure deployed in the Los Alamos RAGE radiation-hydrodynamics code to produce images from a running large scale 3D ICF simulation on the Cielo supercomputer at Los Alamos. The detailed procedures for the creation of the visualizations using ParaView/Catalyst are discussed and several images sequences from the ICF simulation problem produced with the in-situ method are presented. My impressions and conclusions concerning the use of the in-situ visualization method in RAGE are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-Situ Visualization Experiments with ParaView Cinema in RAGE

A previous paper described some numerical experiments performed using the ParaView/Catalyst in-situ visualization infrastructure deployed in the Los Alamos RAGE radiation-hydrodynamics code to produce images from a running large scale 3D ICF simulation. One challenge of the in-situ approach apparent in these experiments was the difficulty of choosing parameters likes isosurface values for the visualizations to be produced from the running simulation without the benefit of prior knowledge of the simulation results and the resultant cost of recomputing in-situ generated images when parameters are chosen suboptimally. A proposed method of addressing this difficulty is to simply render multiple images at runtime with a range of possible parameter values to produce a large database of images and to provide the user with a tool for managing the resulting database of imagery. Recently, ParaView/Catalyst has been extended to include such a capability via the so-called Cinema framework. Here I describe some initial experiments with the first delivery of Cinema and make some recommendations for future extensions of Cinema’s capabilities.

in-situ visualization↗

Design and Evaluation of a Pixelated PSD-capable Scintillator Detector with SiPM Readout

We present the detector response comparison between a 10x10 pixellated array of scintillator read out with Anger logic using four 2" Hamamatsu R7724-100 super bialkali photomultiplier tubes (PMT) and a custom Silicon photomultiplier (SiPM) board consisting of 100 C-series 6x6 mm SiPMs from SensL. An array of these pixellated detectors are currently used in the Neutron Coded Aperture (NCA) imaging system. The energy, timing and pulse shape discrimination response using both readout schemes are presented, along with an analysis of multiple scatter events occurring within the block. An evaluation of the impact of photodetector readout on the overall detection efficiency and imaging accuracy is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Peregrine

The purpose of “Peregrine” is to perform in-situ quality control of the additive manufacturing process in powder bed systems. The software is an AI-based method to automatically detect and map multiple classes of defects present in the top layer of a powder bed system, either after material deposition, i.e. raking, or after printing the layer. Relying on image data or sensing modalities that can be converted into image data, the code allows for: (1) various steps of pre-processing of the data (registration, distortion correction, etc), (2) annotation of training datasets, (3) processing of data inline or offline, (4) creating 3D rendering of the defect map, and (5) implementation of corrective actions if allowed by the manufacturing platform.

Paquit, Vincent C↗

Parallel Infrastructure Modeling and Inversion Module for E4D

Electrical resistivity tomography ERT is a method of imaging the electrical conductivity of the subsurface. Electrical conductivity is a useful metric for understanding the subsurface because it is governed by geomechanical and geochemical properties that drive subsurface systems. ERT works by injecting current into the subsurface across a pair of electrodes, and measuring the corresponding electrical potential response across another pair of electrodes. Many such measurements are strategically taken across an array of electrodes to produce an ERT data set. These data are then processed through a computationally demanding process known as inversion to produce an image of the subsurface conductivity structure that gave rise to the measurements. Data can be inverted to provide 2D images, 3D images, or in the case of time-lapse 3D imaging, 4D images. ERT is generally not well suited for environments with buried electrically conductive infrastructure such as pipes, tanks, or well casings, because these features tend to dominate and degrade ERT images. This reduces or eliminates the utility of ERT imaging where it would otherwise be highly useful for, for example, imaging fluid migration from leaking pipes, imaging soil contamination beneath leaking subsurface tanks, and monitoring contaminant migration in locations with dense network of metal cased monitoring wells. The location and dimension of buried metallic infrastructure is often known. If so, then the effects of the infrastructure can be explicitly modeled within the ERT imaging algorithm, and thereby removed from the corresponding ERT image. However, there are a number of obstacles limiting this application. 1) Metallic infrastructure cannot be accurately modeled with standard codes because of the large contrast in conductivity between the metal and host material. 2) Modeling infrastructure in true dimension requires the computational mesh to be highly refined near the metal inclusions, which increases computational demands. 3) The ERT imaging algorithm requires specialized modifications to accommodate high conductivity inclusions within the computational mesh. The solution to each of these challenges was implemented within E4D (formerly FERM3D), which is a parallel ERT imaging code developed at PNNL (IPID #30249). The infrastructure modeling module implement in E4D uses a method of decoupling the model at the metallic interface(s) boundaries, into several well posed sub-problems (one for each distinct metallic inclusion) that are subsequently solved and recombined to form the global solution. The approach is based on the immersed interface method, with has been applied for similar problems in other fields (e.g. semiconductor industry). Comparisons to analytic solutions have shown the results to be very accurate, addressing item 1 above. The solution is implemented about an unstructured mesh, which enables arbitrary shapes to be efficiently modelled, thereby addressing item 2 above. In addition, the algorithm is written in parallel and shows excellent scalability, which also addresses equation 2 above. Finally, because only the boundaries of metallic inclusions are modeled, there are no high conductivity cells within the modeling mesh, and the problem described by item 3 above is no longer applicable.

Johnson, TimC.↗

Spherical time-encoded radiation imaging simulations

Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. Furthermore, these polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts

Purpose: Develop a computer-aided detection method and investigate its feasibility for detection of breast cancer in automated 3D ultrasound images of women with dense breasts. Methods: The HIPAA compliant study involved a dataset of volumetric ultrasound image data, “views,” acquired with an automated U-Systems Somo•V{sup ®} ABUS system for 185 asymptomatic women with dense breasts (BI-RADS Composition/Density 3 or 4). For each patient, three whole-breast views (3D image volumes) per breast were acquired. A total of 52 patients had breast cancer (61 cancers), diagnosed through any follow-up at most 365 days after the original screening mammogram. Thirty-one of these patients (32 cancers) had a screening-mammogram with a clinically assigned BI-RADS Assessment Category 1 or 2, i.e., were mammographically negative. All software used for analysis was developed in-house and involved 3 steps: (1) detection of initial tumor candidates, (2) characterization of candidates, and (3) elimination of false-positive candidates. Performance was assessed by calculating the cancer detection sensitivity as a function of the number of “marks” (detections) per view. Results: At a single mark per view, i.e., six marks per patient, the median detection sensitivity by cancer was 50.0% (16/32) ± 6% for patients with a screening mammogram-assigned BI-RADS category 1 or 2—similar to radiologists’ performance sensitivity (49.9%) for this dataset from a prior reader study—and 45.9% (28/61) ± 4% for all patients. Conclusions: Promising detection sensitivity was obtained for the computer on a 3D ultrasound dataset of women with dense breasts at a rate of false-positive detections that may be acceptable for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Apparatus and method to achieve high-resolution microscopy with non-diffracting or refracting radiation

An imaging system employing a coded aperture mask having multiple pinholes is provided. The coded aperture mask is placed at a radiation source to pass the radiation through. The radiation impinges on, and passes through an object, which alters the radiation by absorption and/or scattering. Upon passing through the object, the radiation is detected at a detector plane to form an encoded image, which includes information on the absorption and/or scattering caused by the material and structural attributes of the object. The encoded image is decoded to provide a reconstructed image of the object. Because the coded aperture mask includes multiple pinholes, the radiation intensity is greater than a comparable system employing a single pinhole, thereby enabling a higher resolution. Further, the decoding of the encoded image can be performed to generate multiple images of the object at different distances from the detector plane. Methods and programs for operating the imaging system are also disclosed.

47 OTHER INSTRUMENTATION↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tomographic Image Reconstruction for the Parallel-Slit Ring Collimator Fast Neutron Emission Tomography System

For the past three years, Oak Ridge National Laboratory (ORNL) has been developing a passive fast-neutron emission tomography capability. The goal of this development is the ability to quantify the neutron source strength of individual fuel pins (rods) in spent nuclear fuel assemblies. Such a system could be used to measure the burnup of each fuel pin in a spent fuel assembly in order to take burnup credit when loading dry storage casks or to count individual fuel pins in spent fuel assemblies for safeguards purposes. At present, a laboratory prototype imager is under construction. The purpose of this prototype is to demonstrate imaging capability sufficient to resolve individual fuel pins in spent fuel assemblies. This report documents the development of the iterative reconstruction code used to perform tomographic image reconstruction, the imager response calculation used by the reconstruction code, and the results of reconstructions of simulated tomographic imaging measurements for the prototype imager design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coded-mask-based X-ray phase-contrast and dark-field imaging

Phase contrast and dark-field X-ray imaging enable imaging of objects that absorb or reflect very little X-ray light. Disclosed is a method and systems for performing coded-mask-based multi-contrast imaging (CMMI). The method includes providing radiation to a coded mask that has a known phase and absorption profile according to a pre-determined pattern. The radiation is then impingent upon a sample, and the radiation is detected to perform phase-reconstruction and image processing. The method and associated systems allow for the use of maximum-likelihood and machine learning methods for reconstruction images of the sample from the detected radiation.

Shi, Xianbo↗