Swirl Diffuser

Gas diffuser, based on swirling flow, dissipates incoming gas velocity in relatively short distance. Pinwheel nozzle welded to end of inlet pipe creates swirling flow. Diffuser esentially open pipe with pinwheel nozzle, pressure drop in diffuser almost same as open pipe. Applications include fuel burners in room inlets for heating and air-conditioning, and carburetors for internal-combustion engines.

Simon, W. E.↗

SUPIN: A Tool for the Aerodynamic Design and Analysis of Supersonic Inlets

The Supersonic Inlet Design and Analysis Tool (SUPIN) is a computational program that performs geometric modeling and aerodynamic design and analysis of a set of supersonic inlets whose types include the axisymmetric pitot, three-dimensional pitot, axisymmetric, two-dimensional, two-dimensional bifurcated-duct, and streamline-traced inlets. The inlets are modeled by dividing the inlet flowpath into components that start at the freestream and ends at the engine face. The primary components of the inlet include the external supersonic diffuser, throat section, and subsonic diffuser. Each component is characterized by a set of inputs that include geometric and aerodynamic factors. Examples of the geometric factors are angles, lengths, area ratios, and coordinates that describe the geometry of the components. Examples of the aerodynamic factors are Mach numbers, flow ratios, and pressure ratios that set constraints or desired aerodynamic properties of the component. These input factors are specified within a text-based input data file that is read into SUPIN. SUPIN is a Fortran 95 program that performs the inlet design and analysis as a batch or non-interactive process. SUPIN writes output data files describing the inlet geometry and aerodynamic performance. SUPIN uses analytic, empirical, and numerical methods to perform the inlet design and analysis. The inlet geometry is constructed using planar and three-dimensional geometry constructs and is represented by coordinates, angles, areas, profiles, and surfaces. Surfaces are output in the form of a Plot3D surface grid file. SUPIN does have some capability to automatically generate planar and three-dimensional, multi-block, structured grids for computational fluid dynamics (CFD) analysis. The aerodynamic analysis performed by SUPIN computes quasi-one-dimensional properties, such as Mach numbers, pressures, and temperatures, through the inlet flowpath. Planar aerodynamic properties, such as those for shock and Mach waves, are computed for the supersonic compression of the external supersonic diffuser and throat section. The inlet performance is characterized by the inlet flow rates, total pressure recovery, and inlet drag. The primary intent of this document is to describe the usage of SUPIN. The methods used within SUPIN are documented and may serve as a useful reference for understanding the aerodynamic design and analysis of supersonic inlets.

supersonic inlets↗

An Investigation of Convergent-Divergent Diffusers at Mach Number 1.85

An investigation has been conducted in the Cleveland 18- by 18-inch supersonic tunnel at a Mach number of 1.85 and angles of attack from 0 deg to 5 deg to determine optimum design configurations for a convergent-divergent type of supersonic diffuser with a subsonic diffuser of 5 deg included divergence angle. Total pressure recoveries in excess of theoretical recovery across a normal shock at a free-stream Mach number of 1.85 wore obtained with several configurations. The highest recovery for configurations without a cylindrical throat section was obtained with an inlet having an included convergence angle of 20 deg. Insertion of a 2-inch throat section between a 10 deg included angle inlet and the subsonic diffuser stabilized the shock inside the diffuser and resulted in recoveries as high as 0.838 free-stream total pressure at an angle of attack of 0 deg, corresponding to recovery of 92.4 percent of the kinetic energy of the free air stream. Use of the throat section also lessened the reduction in recovery of all configurations due to angle of attack.

Wyatt, Demarquis D↗

Comparison of experimental and theoretical boundary-layer separation for inlets at incidence angle at low-speed conditions

Comparisons between experimental and theoretical Mach number distributions and separation locations are presented for the internal surfaces of four different subsonic inlet geometries with exit diameters of 13.97 centimeters. The free stream Mach number was held constant at 0.127, the one-dimensional throat Mach number ranged from 0.49 to 0.71, and the incidence angle ranged from 0 deg to 50 deg. Generally good agreement was found between the theoretical and experimental surface Mach number distributions as long as no flow separation existed. At high incidence angles, where separation was obvious in the experimental data, the theory predicted separation on the lip. At lower incidence angles, the theoretical results indicated diffuser separation which was not obvious from the experimental surface Mach number distributions. As incidence angle was varied from 0 deg to 50 deg, the predicted separation location shifted from the diffuser region to the inlet highlight. Relatively small total pressure losses were obtained when the predicted separation location was greater than 0.6 of the distance between the highlight and the diffuser exit.

Felderman, E. J.↗

Rotary blood pump

A blood pump that comprises a pump housing having a blood flow path therethrough, a blood inlet, and a blood outlet; a stator mounted to the pump housing, the stator having a stator field winding for producing a stator magnetic field; a flow straightener located within the pump housing, and comprising a flow straightener hub and at least one flow straightener blade attached to the flow straightener hub; a rotor mounted within the pump housing for rotation in response to the stator magnetic field, the rotor comprising an inducer and an impeller; the inducer being located downstream of the flow straightener, and comprising an inducer hub and at least one inducer blade attached to the inducer hub; the impeller being located downstream of the inducer, and comprising an impeller hub and at least one impeller blade attached to the impeller hub; and preferably also comprising a diffuser downstream of the impeller, the diffuser comprising a diffuser hub and at least one diffuser blade. Blood flow stagnation and clot formation within the pump are minimized by, among other things, providing the inducer hub with a diameter greater than the diameter of the flow straightener hub; by optimizing the axial spacing between the flow straightener hub and the inducer hub, and between the impeller hub and the diffuser hub; by optimizing the inlet angle of the diffuser blades; and by providing fillets or curved transitions between the upstream end of the inducer hub and the shaft mounted therein, and between the impeller hub and the shaft mounted therein.

Benkowski, Robert J.↗

Experimental Investigation of a Two-dimensional Split-wing Ram-jet Inlet at Mach Number of 3.85

Performance characteristics of a two-dimensional isentropic diffuser have been experimentally determined at a Mach number of 3.85. At zero angle of attack, a maximum total-pressure recovery of 0.41 was obtained with a supercritical mass-flow ratio of 0.95. As a consequence of the twin-duct arrangement of the diffuser, a large discontinuity in pressure recovery and mass flow with a characteristic hysteresis was encountered between critical and subcritical operation. An asymmetric shock pattern with large-scale separation and flow reversal in one of the passages occurred at reduced mass flows. Pressure and force data presented for an angle-of-attack range from zero to 4 degrees.

DIFFUSERS, SUPERSONIC↗

Velocity and pressure characteristics of a model SSME high pressure fuel turbopump

Under the present effort an experiment rig has been constructed, an instrumentation package developed and a series of mean and rms velocity and pressure measurements made in a turbopump which modelled the first stage of the Space Shuttle Main Engine (SSME) High Pressure Fuel Turbopump. The rig was designed so as to allow initial experiments with a single configuration consisting of a bell-mouth inlet, a flight impeller, a vaneless diffuser and a volute. Allowance was made for components such as inlet guide vanes, exit guide vanes, downstream pumps, etc. to be added in future experiments. This flexibility will provide a clear baseline set of experiments and allow evaluation in later experiments of the effect of adding specific components upon the pump performance properties. The rotational speed of the impeller was varied between 4260 and 7680 rpm which covered the range of scaled SSME rotation speeds when due allowance is made for the differing stagnation temperature, model to full scale. The results at the inlet obtained with rotational speeds of 4260, 6084 and 7680 rpm showed that the axial velocity at the bell-mouth inlet remained roughly constant at 2.2 of the bulk velocity at the exit of the turbopump near the center of the inlet, but it decreased rapidly with increasing radius at all three speeds. Reverse flow occurred at a radius greater than 0.9 R for all three speeds and the maximum negative velocity reduced from 1.3 of the bulk velocity at the exit of the turbopump at 4260 rpm to 0.35 at 7680 rpm, suggesting that operating at a speed closer to the design condition of 8700 rpm improved the inlet characteristics. The reverse flow caused positive prerotation at the impeller inlet which was negligibly small near the center but reached 0.7 of the impeller speed at the outer annulus. The results in the diffuser and the volute obtained at 7680 rpm show that the hub and shroud walls of the diffuser were characterized by regions of transient reverse flow with negative revolution-averaged velocity of 8 percent of the maximum forward revolution-averaged velocity at the center of the diffuser passage near the shroud wall.

Tse, D. G-N.↗

Application of computational fluid dynamics to complex inlet ducts

A three-dimensional parabolic Navier-Stokes code, PEPSIG, was used to analyze the flow in the subsonic diffuser section of a typical modern inlet design. The effect of curvature of the diffuser centerline and transitioning cross sections was studied to determine the primary cause of flow distortion in the duct. Total pressure values at the engine compressor face are reported.

Towne, C. E.↗

Application of computational fluid dynamics to complex inlet ducts

A three-dimensional parabolic Navier-Stokes code, PEPSIG, was used to analyze the flow in the subsonic diffuser section of a typical modern inlet design. The effect of curvature of the diffuser centerline and transitioning cross sections was studied to determine the primary cause of flow distortion in the duct. Total pressure values at the engine compressor face are reported.

Towne, C. E.↗

Exploratory investigation of the use of area suction to eliminate air-flow separation in diffusers having large expansion angles

Tests were made at a mean inlet Mach number of 0.2 with area suction applied to conical diffusers with expansion angles of 30 degrees and 50 degrees and exit to inlet area ratios of 2. Air-flow separation was eliminated with suction mass flows of 3 and 4 percent of the inlet mass flows for the 30 degrees and 50 degrees diffusers, respectively.

DIFFUSERS, SUBSONIC↗

Impeller flow field characterization with a laser two-focus velocimeter

Use of Computational Fluid Dynamics (CFD) codes, prevalent in the rocket engine turbomachinery industry, necessitates data of sufficient quality and quantity to benchmark computational codes. Existing data bases for typical rocket engine configurations, in particular impellers, are limited. In addition, traditional data acquisition methods have several limitations: typically transducer uncertainties are 0.5% of transducer full scale and traditional pressure probes are unable to provide flow characteristics in the circumferential (blade-to-blade) direction. Laser velocimetry circumvents these limitations by providing +0.5% uncertainty in flow velocity and +0.5% uncertainty in flow angle. The percent of uncertainty in flow velocity is based on the measured value, not full range capability. The laser electronics multiple partitioning capability allows data acquired between blades as the impeller rotates, to be analyzed separately, thus providing blade-to-blade flow characterization. Unlike some probes, the non-intrusive measurements made with the laser velocimeter does not disturb the flow. To this end,, and under Contract (NAS8-38864) to the National Aeronautics and Space Administration (NASA) at Marshall Space Flight Center (MSFC), an extensive test program was undertaken at Rocketdyne. Impellers from two different generic rocket engine pump configurations were examined. The impellers represent different spectrums of pump design: the Space Shuttle Main Engine (SSME) high pressure fuel turbopump (HPFTP) impeller was designed in the 1 1970's the Consortium for CFD application in Propulsion Technology Pump Stage Technology Team (Pump Consortium) optimized impeller was designed with the aid of modern computing techniques. The tester configuration for each of the impellers consisted of an axial inlet, an inducer, a diffuser, and a crossover discharge. While the tested configurations were carefully chosen to be representative of generic rocket engine pumps, several features of both testers were intentionally atypical. A crossover discharge, downstream of the impeller, rather than a volute discharge was used to minimize asymmetric flow conditions that might be reflected in the impeller discharge flow data. Impeller shroud wear ring radial clearances were purposely close to minimize leakage flow, thus increasing confidence in using the inlet data as an input to CFD programs. The empirical study extensively examined the flow fields of the two impellers via performance of laser two-focus velocimeter surveys in an axial plane upstream of the impellers and in multiple radial planes downstream of the impellers. Both studies were performed at the impeller design flow coefficients. Inlet laser surveys that provide CFD code inlet boundary conditions were performed in one axial plane, with ten radial locations surveyed. Three wall static pressures, positioned circumferentially around the impeller inlet, were used to identify asymmetrical pressure distributions in the inlet survey plane. The impeller discharge flow characterization consisted of three radial planes for the SSME HPFTP impeller and two radial planes for the Pump Consortium optimized impeller. Housing wall static pressures were placed to correspond to the radial locations surveyed with the laser velocimeter. Between five and thirteen axial stations across the discharge channel width were examined in each radial plane during the extensive flow mapping. The largely successful empirical flow characterization of two different impellers resulted in a substantial contribution to the limited existing data base, and yielded accurate data for CFD code benchmarking.

Brozowski, L. A.↗

Exploratory Investigation of the Effects of Boundary-Layer Control on the Pressure-Recovery Characteristics of a Circular Internal-Contraction Inlet with Translating Centerbody at Mach Numbers of 2.00 and 2.35

Exploratory tests of a circular internal-contraction inlet were made at Mach numbers of 2.00 and 2.35 to determine the effect of a cowl-type boundary-layer control located downstream of the inlet throat. The inlet was designed for a Mach number of 2.5. Tests were also made of the inlet modified to correspond to design Mach numbers of 2.35 and 2.25. Surveys near the minimum area section of the inlet without boundary-layer control indicated maximum averaged pressure recoveries between 0.90 and 0.92 at a free-stream Mach number, M(sub infinity), of 2.35 for the inlets. Farther downstream, after partial subsonic diffusion, a maximum pressure recovery of 0.842 was obtained with the inlet at M(sub infinity) = 2.35. The pressure recovery of the inlet was increased by 0.03 at a Mach number of 2.35 and decreased by 0.02 at a Mach number of 2.00 by the application of cowl-type boundary-layer control. Further investigation with the inlet without bleed demonstrated that an increase of angle of attack from 0 deg to 3 deg reduced the pressure recovery 0.04. The effect of Reynolds number was to increase pressure recovery 0.07 (from 0.785 to 0.855) with an increase in Reynolds number (based on inlet diameter) from 0.79 x 10(exp 6) to 3.19 x 10(exp 6).

Martin, Norman J.↗

Additional testing of the inlets designed for a tandem fan V/STOL nacelle

The wind tunnel testing of a scale model of a tandem fan nacelle designed for a type (subsonic cruise) V/STOL aircraft configuration is discussed. The performance for the isolated front inlet and for the combined front and aft inlets is reported. Model variables include front and aft inlets with aft inlet variations of short and long aft inlet cowls, with a shaft simulator and diffuser vortex generators, cowl lip fillets, and nacelle strakes. Inlet pressure recovery, distortion, and inlet angle-to-attack separation limits were evaluated at tunnel velocity from 0 to 240 knots, angles-of-attack from -10 to +40 degrees and inlet flow rates corresponding to throat Mach number from 0.0 to 0.6. Combined nacelle pitch and yaw runs up to 30 deg. were also made.

Ybarra, A. H.↗

Performance of a short annular dump diffuser using wall trailing-edge suction

A short annular dump (abrupt flow area change) diffuser was tested with suction through wall trailing-edge slots at inlet Mach numbers of 0.19 and 0.27 and at near ambient inlet temperature and pressure, with suction flow varied from zero to 10 percent of the inlet air mass-flow rate. The overall ratio of diffuser exit area to inlet area was 4.0, and the ratio of length to inlet height was 2.0. By applying suction flow separately on either wall or to both walls simultaneously, the original annular jet profile could be altered to either a hub- or tip-biased profile. Diffuser effectiveness was increased from about 25 percent with no suction to 50 percent at 6 percent outer-wall suction and to 52 percent at a combined suction rate on both walls of 10.25 percent. At the same time, diffuser total pressure loss was reduced by one-fourth.

Juhasz, A. J.↗

Investigation of Pressure Recovery of a Single-conical-shock Nose Inlet at Mach Number 5.4

An experimental investigation of the performance of a single-conical-shock diffuser was conducted at a Mach number of 5.4 and a Reynolds number based on model diameter of 375,000. Total-pressure recoveries of 13.7 and 13.1 percent were obtained at angles of attack of 0 degrees and 3 degrees, respectively. The corresponding kinetic energy efficiencies were 86.4 percent at an angle of attack of 0 degrees and 86.0 percent at an angle of attack of 3 degrees.

DIFFUSERS, SUPERSONIC↗

Conical diffuser for fuel cells

Diffuser is inserted into inlet manifold, producing smooth transition of flow from pipe diameter to manifold diameter. Expected pressure gradient and resulting cell-to-cell temperature gradient are reduced. Outlet manifold has nozzle insert that reduces exit losses.

Craft, D. W.↗

Design, development, and test of a laser velocimeter for a small 8:1 pressure ratio centrifugal compressor

The instrument was designed as a diagnostic tool for the basic fluid dynamics of the inducer, impeller, and diffuser regions of this type compressor. The LV instrumentation was optimized to measure instantaneous velocities up to approximately 500 m/s, measured in absolute coordinates, within the rotating compressor impeller and in the two dimensional radial plane of the diffuser. Some measurements were made within the diffuser and the impeller inlet flows; however, attempts to make detailed measurements of the velocity field were not successful. Difficulties in maintaining high seed particle rates within the probe volume and the improper operation of the blade gating optics may explain the lack of success. Recommendations are made to further pursue these problems. At 100% speed the stage attained a total static pressure ratio of 7.5:1 at 75% total-static efficiency. Flow range from choke-to-surge was 6.8% of choking mass flow rate. Performance was lower than the design intent of 8:1 pressure ratio at 77% efficiency and 12% flow range. Detailed measurements of the stage components are presented which show the reasons for the stage performance deficiencies.

Dolan, F. X.↗

Adaptation of a Cascade Impactor to Flight Measurement of Droplet Size in Clouds

A cascade impactor, an instrument for obtaining: the size distribution of droplets borne in a low-velocity air stream, was adapted for flight cloud droplet-size studies. The air containing the droplets was slowed down from flight speed by a diffuser to the inlet-air velocity of the impactor. The droplets that enter the impactor impinge on four slides coated with magnesium oxide. Each slide catches a different size range. The relation between the size of droplet impressions and the droplet size was evaluated so that the droplet-size distributions may be found from these slides. The magnesium oxide coating provides a permanent record. of the droplet impression that is not affected by droplet evaporation after the. droplets have impinged.

Levine, Joseph↗