At least 199 records · Page 11

Cyber Dynamic Impact Modeling Engine

As the rate, sophistication, and potential damage of cyber attacks continue to grow, the latency of human-speed analysis and response is becoming increasingly costly. Intelligent response to detected attacks and other malicious activity requires both knowledge of the characteristics of the attack as well as how resources involved in the attack related to the mission of the organization. Cydime fills this need by estimating a key component of intrusion detection and response automation: the relationship type and strength between the target organization and the potential attacker.

Source record↗

Project Boeing SGS (Final Report)

Boeing and its partner, PJM Interconnection, teamed to bring advanced “defense-grade” technologies for cyber security to the US regional power grid through demonstration in PJM’s energy management environment. Under this cooperative project with the Department of Energy, Boeing and PJM have developed and demonstrated a host of technologies specifically tailored to the needs of PJM and the electric sector as a whole. The team has demonstrated to the energy industry a combination of processes, techniques and technologies that have been successfully implemented in the commercial, defense, and intelligence communities to identify, mitigate and continuously monitor the cyber security of critical systems. Guided by the results of a Cyber Security Risk-Based Assessment completed in Phase I, the Boeing-PJM team has completed multiple iterations through the Phase II Development and Phase III Deployment phases. Multiple cyber security solutions have been completed across a variety of controls including: Application Security, Enhanced Malware Detection, Security Incident and Event Management (SIEM) Optimization, Continuous Vulnerability Monitoring, SCADA Monitoring/Intrusion Detection, Operational Resiliency, Cyber Range simulations and hands on cyber security personnel training. All of the developed and demonstrated solutions are suitable for replication across the electric sector and/or the energy sector as a whole. Benefits identified include; Improved malware and intrusion detection capability on critical SCADA networks including behavioral-based alerts resulting in improved zero-day threat protection; Improved Security Incident and Event Management system resulting in better threat visibility, thus increasing the likelihood of detecting a serious event; Improved malware detection and zero-day threat response capability; Improved ability to systematically evaluate and secure in house and vendor sourced software applications; Improved ability to continuously monitor and maintain secure configuration of network devices resulting in reduced vulnerabilities for potential exploitation; Improved overall cyber security situational awareness through the integration of multiple discrete security technologies into a single cyber security reporting console; Improved ability to maintain the resiliency of critical systems in the face of a targeted cyber attack of other significant event; Improved ability to model complex networks for penetration testing and advanced training of cyber security personnel

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Dynamic Impact Modeling Engine

As the rate, sophistication, and potential damage of cyber attacks continue to grow, the latency of human-speed analysis and response is becoming increasingly costly. Intelligent response to detected attacks and other malicious activity requires both knowledge of the characteristics of the attack as well as how resources involved in the attack related to the mission of the organization. Cydime fills this need by estimating a key component of intrusion detection and response automation: the relationship type and strength between the target organization and the potential attacker.

Source record↗

An Artificially Intelligent Physical Model-Checking Approach to Detect Switching-Related Attacks on Power Systems

Decentralized and hierarchical microgrid control strategies have lain the groundwork for shaping the future smart grid. Such control approaches require the cooperation between microgrid operators in control centers, intelligent microcontrollers, and remote terminal units via secure and reliable communication networks. In order to enhance the security and complement the work of network intrusion detection systems, this paper presents an artificially intelligent physical model-checking that detects tampered-with circuit breaker switching control commands whether, due to a cyber-attack or human error. In this technique, distributed agents, which are monitoring sectionalized areas of a given microgrid, will be trained and continuously adapted to verify that incoming control commands do not violate the physical system operational standards and do not put the microgrid in an insecure state. The potential of this approach has been tested by deploying agents that monitor circuit breakers status commands on a 14-bus IEEE benchmark system. The results showed the accuracy of the proposed framework in characterizing the power system and successfully detecting malicious and/or erroneous control commands.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detecting Distributed SQL Injection Attacks in a Eucalyptus Cloud Environment

The cloud computing environment offers malicious users the ability to spawn multiple instances of cloud nodes that are similar to virtual machines, except that they can have separate external IP addresses. In this paper we demonstrate how this ability can be exploited by an attacker to distribute his/her attack, in particular SQL injection attacks, in such a way that an intrusion detection system (IDS) could fail to identify this attack. To demonstrate this, we set up a small private cloud, established a vulnerable website in one instance, and placed an IDS within the cloud to monitor the network traffic. We found that an attacker could quite easily defeat the IDS by periodically altering its IP address. To detect such an attacker, we propose to use multi-agent plan recognition, where the multiple source IPs are considered as different agents who are mounting a collaborative attack. We show that such a formulation of this problem yields a more sophisticated approach to detecting SQL injection attacks within a cloud computing environment.

Kebert, Alan↗

False Data Injection and Detection in LQG Systems: A Game Theoretic Approach

Cyber-physical systems are vulnerable to false data injection by adversaries who compromise cyber communication links. In this paper, an infinite horizon linear quadratic Gaussian (LQG) system is considered wherein the control inputs transmitted over cyber links are vulnerable to compromise and false data injection by adversaries. The adversarial cyber-attack is driven to minimize the performance of the LQG system, and the controller is equipped with an intrusion detection system that monitors the sequence of internal physical states to detect adversarial input modification. The problem is formulated as a two-player zero-sum game with the false alarm probability as the reward, wherein the attacker aims to achieve a target increase in controller cost while maximizing the false alarm probability, and a detector who wishes to minimize the false alarm probability while remaining consistent. It is shown that in such a game, an ε-equilibrium exists. The equilibrium attacker strategy is the one that minimizes the Kullback-Leibler distance between legitimate and falsified state dynamics, and the equilibrium detector strategy is the corresponding likelihood-ratio test. Numerical simulations are presented that showcase the equilibrium strategy pair and the intuitive strategies comparisons.

97 MATHEMATICS AND COMPUTING↗

AI-based Detection and Defense Against Cyberattacks in Distributed Energy Resources

This study will provide comprehensive artificial intelligence (AI)-based solution tools for network security, malware prevention, and sensor data anomaly detection for distributed energy resource (DER) research, development, and demonstration. DER technologies are energy systems (e.g., solar panels, wind turbines, and energy storage systems) that are often connected to the internet and thus vulnerable to cyberattacks. Cybersecurity should be of primary concern for DERs, which is why we propose an integrated multi-layer cyber-defense system for DERs. This system encompasses risk assessments, network security, malware prevention, and detection of anomalies in the sensor data. Implementation of a comprehensive risk assessment with an overview of the model architecture should be the primary step, and should include the potential impact of experiencing, at a given time, one or more cyberattacks on the system. The second step is to ensure that the network security includes firewalls, intrusion detection, and malware prevention. The third step is to provide solution tools that enable sensor data anomaly detection for DERs. By incorporating these considerations into DER research, development, and demonstration, organizations can help ensure the safety and security of their systems and protect against potential cyberattacks.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluating lightweight unsupervised online IDS for masquerade attacks in CAN

Vehicular controller area networks (CANs) are susceptible to masquerade attacks by malicious adversaries. In masquerade attacks, adversaries silence a targeted ID and then send malicious frames with forged content at the expected timing of benign frames. As masquerade attacks could seriously harm vehicle functionality and are the stealthiest attacks to detect in CAN, recent work has devoted attention to compare frameworks for detecting masquerade attacks in CAN. However, most existing works report offline evaluations using CAN logs already collected using simulations that do not comply with the domain’s real-time constraints. Here we contribute to advance the state of the art by presenting a comparative evaluation of four different non-deep learning (DL)-based unsupervised online intrusion detection systems (IDS) for masquerade attacks in CAN. Our approach differs from existing comparative evaluations in that we analyze the effect of controlling streaming data conditions in a sliding window setting. In doing so, we use realistic masquerade attacks being replayed from the ROAD dataset. We show that although evaluated IDS are not effective at detecting every attack type, the method that relies on detecting changes in the hierarchical structure of clusters of time series produces the best results at the expense of higher computational overhead. We discuss limitations, open challenges, and how the evaluated methods can be used for practical unsupervised online CAN IDS for masquerade attacks.

Anomaly detection↗

Numerical Investigation of the Electrical Resistivity Tomography for Detecting the Waste Zone beneath an Engineered Surface

Surface barriers are an integral part of waste site remediation that are needed to minimize further contamination spread, allow time for additional radionuclide decay, and decrease risks to workers and the environment. Depending on the type of waste, the design life of a surface barrier varies from decades to millennia. The performance and impacts of surface barriers must be monitored beyond the life of most monitoring instruments; hence, long-term monitoring technologies are needed that can non-intrusively assess barrier impacts both in the near surface and to large depths. Innovative geophysical methods such as the electrical resistivity tomography (ERT) are capable of non-intrusively detecting the distribution of soil wetness and/or contaminant plumes in the soil. However, the application of geophysical methods in monitoring a surface barrier system has been very limited because a surface barrier is often composed of multiple components made of natural (e.g., soil, rocks, asphalt) and manufactured (e.g., plastic, metal) materials. In this study, the E4D numerical simulator, developed at Pacific Northwest National Laboratory for inverting the ERT survey data, was used to evaluate the configuration of electrodes for optimized ERT monitoring of waste zone below a surface barrier. The results indicate that, for high-quality mapping of the conditions below the surface barrier, the ERT method requires that some of the electrodes be installed either beneath the surface barrier or in boreholes around the barrier. In reality, for a surface barrier that is being constructed, some electrodes may be installed beneath the non-conductive layer of the surface barrier before or during barrier construction. For a surface barrier that has already been constructed, some electrodes can be installed in a few vertical boreholes around the barrier boundary.

Zhang, Zhuanfang↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

One-Dimensional Scanning Approach to Shock Sensing

Measurement tools for high speed air flow are sought both in industry and academia. Particular interest is shown in air flows that exhibit aerodynamic shocks. Shocks are accompanied by sudden changes in density, pressure, and temperature. Optical detection and characterization of such shocks can be difficult because the medium is normally transparent air. A variety of techniques to analyze these flows are available, but they often require large windows and optical components as in the case of Schlieren measurements and/or large operating powers which precludes their use for in-flight monitoring and applications. The one-dimensional scanning approach in this work is a compact low power technique that can be used to non-intrusively detect shocks. The shock is detected by analyzing the optical pattern generated by a small diameter laser beam as it passes through the shock. The optical properties of a shock result in diffraction and spreading of the beam as well as interference fringes. To investigate the feasibility of this technique a shock is simulated by a 426 m diameter optical fiber. Analysis of results revealed a direct correlation between the optical fiber or shock location and the beam s diffraction pattern. A plot of the width of the diffraction pattern vs. optical fiber location reveals that the width of the diffraction pattern was maximized when the laser beam is directed at the center of the optical fiber. This work indicates that the one-dimensional scanning approach may be able to determine the location of an actual shock. Near and far field effects associated with a small diameter laser beam striking an optical fiber used as a simulated shock are investigated allowing a proper one-dimensional scanning beam technique.

Tokars, Roger↗

HC-NIDS: signatures and simulations for detecting cyber-attacks aiming to cause damage against cyber-physical energy systems

Physical device safety is typically implemented locally using embedded controllers, while operations safety is primarily performed in control centers. Safe operations can be enhanced by correct design of device-level control algorithms, and protocols, procedures and operator training at the control-room level, but all can fail. Moreover, these elements exchange data and issue commands via vulnerable communication layers. In order to secure these gaps and enhance operational safety, we believe monitoring of command sequences must be combined with an awareness of physical device limitations and automata models that capture safety mechanisms. One way of doing this is by leveraging specification-based intrusion detection to monitor for physical constraint violations. The method can also verify that physical infrastructure state is consistent with monitoring information and control commands exchanged between field devices and control centers. This additional security layer enhances protection from both outsider attacks and insider mistakes. We implemented specification-based SCADA command analyzers using physical constraint algorithms directly in the Bro framework and Broccoli APIs for three separate scenarios: a water heater, an automated distribution system, and an over-current protection scheme. To accomplish this, we added low-level analyzers capable of examining control system-specific protocol packets for both Modbus TCP and DNP3, and also higher-level analyzers able to interpret device command and data streams within the context of each device's physical capabilities and present operational state. Thus the software that we are making available includes the Bro/Broccoli scripts for these three scenarios, as well as simulators, written in C, of those scenarios that generate sample traffic that is monitored by the Bro/Broccoli scripts. In addition, we have also implemented systems to directly pull cyber-physical information from the OSIsoft PI historian system. We have included the Python scripts used to perform that monitoring.

Source record↗

HC-NIDS: signatures and simulations for detecting cyber-attacks aiming to cause damage against cyber-physical energy systems

Physical device safety is typically implemented locally using embedded controllers, while operations safety is primarily performed in control centers. Safe operations can be enhanced by correct design of device-level control algorithms, and protocols, procedures and operator training at the control-room level, but all can fail. Moreover, these elements exchange data and issue commands via vulnerable communication layers. In order to secure these gaps and enhance operational safety, we believe monitoring of command sequences must be combined with an awareness of physical device limitations and automata models that capture safety mechanisms. One way of doing this is by leveraging specification-based intrusion detection to monitor for physical constraint violations. The method can also verify that physical infrastructure state is consistent with monitoring information and control commands exchanged between field devices and control centers. This additional security layer enhances protection from both outsider attacks and insider mistakes. We implemented specification-based SCADA command analyzers using physical constraint algorithms directly in the Bro framework and Broccoli APIs for three separate scenarios: a water heater, an automated distribution system, and an over-current protection scheme. To accomplish this, we added low-level analyzers capable of examining control system-specific protocol packets for both Modbus TCP and DNP3, and also higher-level analyzers able to interpret device command and data streams within the context of each device's physical capabilities and present operational state. Thus the software that we are making available includes the Bro/Broccoli scripts for these three scenarios, as well as simulators, written in C, of those scenarios that generate sample traffic that is monitored by the Bro/Broccoli scripts. In addition, we have also implemented systems to directly pull cyber-physical information from the OSIsoft PI historian system. We have included the Python scripts used to perform that monitoring.

Source record↗

Supporting Cyber Security of Power Distribution Systems by Detecting Differences Between Real-time Micro-Synchrophasor Measurements and Cyber-Reported SCADA (Final Report)

As modern power grids tend towards greater levels of automation and communication, the challenges of identifying and mitigating vulnerabilities to cyber-attacks are ones that are increasingly demanding attention. Today’s power system has evolved to form the foundational bedrock of modern society, and an attack on this infrastructure could prove disastrous. In this project we were tasked to investigate the use of distribution synchrophasors as an independent isolated sensor network with which we can corroborate, or flag potentially spoofed,Supervisory Control And Data Acquisition (SCADA) data. We adapted an approach to marry the underlying physical properties of power systems with the network communications used by power systems in order to offer insights unattainable by either data stream isolation. While the concept of intrusion detection systems (IDS) is well understood for monitoring network traffic and traditional IT computing systems, the approach discussed in this report is motivated by several key notions: first, current SCADA communications alone presents an incomplete view of the grid. Second, the power grid, and the equipment controlling it, is grounded by laws of physics. Given this, we leverage high-frequency physical grid measurements to understand the physical condition of the grid, and combine this with SCADA. While high-frequency physical grid measurements and SCADA communication over Internet Protocol (IP) networks are fundamentally disparate information sources, when collectively examined through appropriate lenses, they offer a much more nuanced depiction of the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Firmware Tampering Detection in Heavy-Duty Vehicles through J1939 CAN Analysis

Modern heavy-duty vehicles rely on complex networks of Electronic Control Units (ECUs) that communicate using the J1939 protocol. While this system makes it easier to update and configure vehicle components, it also opens the door to serious cybersecurity risks if not properly secured. This work investigates the potential for firmware tampering through the J1939 communication protocol, which enables ECU configuration and reprogramming over the Controller Area Network (CAN) bus. By monitoring CAN traffic during legitimate maintenance operations and reverse-engineering OEM diagnostic software, we identified common and proprietary J1939 message identifiers, authentication patterns, and vulnerabilities within Unified Diagnostic Services (UDS). These findings demonstrate that inadequate authentication mechanisms can allow malicious actors to alter ECU firmware or disable safety functions, posing severe operational and safety risks. Our analysis contributes to the development of vehicle intrusion detection systems capable of recognizing abnormal reprogramming activity and future firmware fingerprinting methods to verify software integrity across ECUs. This work highlights the importance of standardizing secure firmware authentication across manufacturers to strengthen cyber resilience in heavy-duty vehicle systems.

33 ADVANCED PROPULSION SYSTEMS↗

Nuclear resonance fluorescence excitations near 2 MeV in {sup 235}U and {sup 239}Pu

A search for nuclear resonance fluorescence excitations in {sup 235}U and {sup 239}Pu within the energy range of 1.0- to 2.5-MeV was performed using a 4-MeV continuous bremsstrahlung source at the High Voltage Research Laboratory at the Massachusetts Institute of Technology. Measurements utilizing high purity Ge detectors at backward angles identified nine photopeaks in {sup 235}U and 12 photopeaks in {sup 239}Pu in this energy range. These resonances provide unique signatures that allow the materials to be nonintrusively detected in a variety of environments including fuel cells, waste drums, vehicles, and containers. The presence and properties of these states may prove useful in understanding the mechanisms for mixing low-lying collective dipole excitations with other states at low excitations in heavy nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summer 2024 INL Intern Poster Session Submission - Brian Schumitz

This LRS submission is my poster for the INL Intern Poster Session, Summer 2024. Abstract: The Software Engineering and Cybersecurity Lab (SECL) at Montana State University has developed PIQUE, a system for evaluating software quality. PIQUE's adaptability allows for language-specific static-analysis operations, including a model for assessing cloud microservice ecosystems. These ecosystems often rely on Docker for efficient deployment and management of containerized services. Our research focuses on evaluating the network quality within these microservice ecosystems. To automate this process, we're utilizing Snort, an open-source intrusion detection system renowned for its ability to detect and log network traffic. By leveraging Snort's customizable rules, we aim to construct comprehensive testing methods for measuring and quantifying the network quality based on traffic between Docker containers. This research aims to enhance the overall security and reliability of cloud microservice ecosystems by providing automated and robust quality evaluation mechanisms, ultimately contributing to the advancement of software engineering practices in these environments

97 MATHEMATICS AND COMPUTING↗

Commercialization of the Transportation-Security, Tracking, and Reporting System (T-STAR)

The Transportation-Security, Tracking, and Reporting System (T-STAR) was developed by the National Nuclear Security Administration, NA-21, Office of Radiological Security (ORS) to provide a transportation security system for detection and tracking during transport of Category 1 and Category 2 radiological material. Few off-the-shelf systems for conveyance tracking offer detection of a cargo compartment breach or a removal of the cargo. Systems that do offer this capability often require permanent installation through modifying of the conveyance itself. This is not sustainable in many countries where ORS is building use, storage, and transport security capacity. The development of T-STAR has moved from fielding robust prototypes deployed in countries ranging from North America, Latin America and Central Asia to a commercially produced product that can now be deployed to provide enhanced security during transit. Each prototype deployment resulted in important lessons learned, which informed the requirements for the final commercial product. T-STAR uses both cellular and Iridium satellite modems to provide redundant communications to provide the configuration, status, and alerts to a server monitoring the shipment, which is accessible using a multilanguage browser-based user interface. A wireless security system employing using Z-wave sensors for intrusion detection located in the conveyance provide low cost but effective solution for a wide range of conveyance types. Additional capabilities include the ability to monitor a vehicles’ CANBUS (Controller Area Network) system, an ethernet port for high throughput sensor information such as video cameras, and the ability to power and use advanced external sensor payloads. These features make the T-STAR a capable and expandable security gateway that can be deployed on a variety of conveyances from box trucks to open trailers. The ability to provide tracking, monitoring, and detection provide a key component in overall best practices designed to protect shipments of radioactive material.

Schultze, Michael [ORNL] (ORCID:0000000283205671)↗