Parallel operation of aerospace static inverters.
Parallel operation of aerospace static inverters with load division effected by locking each inverter in-phase and automatic voltage control
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Parallel operation of aerospace static inverters with load division effected by locking each inverter in-phase and automatic voltage control
Inverter with integrated components and direct coupled inverter circuit not needing transformers for space applications
We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, for small-scale radial microgrids, we demonstrate the ability of IBRs to tune the effective transfer functions of synchronous machines. This enables us to relax the uniform turbine time-constant assumptions and widen the scope of existing synchronization results for proportionally heterogeneous machines.
Power system inertia is the inherent capability of a power system to resist changes in its frequency during disturbances. Real-time inertia estimation technology has become more important due to the low-inertia issues caused by the increasing integration levels of inverter-based resources (IBRs) from renewable energy; however, existing inertia estimation methods hardly consider multiple frequency response controls that act within the same time frame as conventional inertial response, thus making measured inertia values vary under different testing conditions. To resolve this issue, this paper proposes a novel real-time estimation method to simultaneously estimate a power system's inertia constant and frequency response droop constant using a well-designed probing signal. First, we formulate the inertia and frequency response model of a power system with IBRs. Second, through the integration and manipulation of the developed model, we propose a multivariate linear regression- based estimation method that is resilient to measurement noise. Third, we design a probing signal that can be injected by IBRs to incite the required transients for estimation. Finally, we validate the proposed estimation method through comprehensive power- hardware-in-the-loop experiments using inverter hardware and a realistic island power system model. The results demonstrate that the proposed method can accurately estimate the inertia and droop value of the power system with grid-following IBRs and grid-forming IBRs with virtual synchronous machine control.
This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.
Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.
This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.
The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses
This paper presents results and new insights gained from a hardware test campaign on a 2 MVA PV inverter for validating its vendor-supplied EMT model. The test campaign was conducted using a 7 MVA grid simulator and a 2 MW PV emulator. It considered both time-domain transient tests and frequency-domain impedance scan tests. The paper highlights the inadequacy of transient tests in capturing all critical resonance modes of the inverter, and the effectiveness of the frequency scan testing in addressing this problem. The paper shows the frequency scan testing as an effective tool for EMT model validation of IBR units which can highlight inaccuracies in the EMT models that are easy to overlook when model validation is performed using only the time-domain transient tests such as voltage ride-through and phase jump tests.
Uncertainty quantification plays a pivotal role in improving the accuracy and reliability of inverter operation within modern power systems that are increasingly dominated by inverter-based resources (IBRs). IBRs, especially those operating under grid forming (GFM) control, rely heavily on a complex set of control parameters and system measurements to maintain voltage, frequency, and power balance. Traditional deterministic modeling approaches often fail to capture these parameter deviations, potentially resulting in suboptimal control actions, reduced system stability, or even instability under high penetration of IBRs. In this paper, we demonstrate the application of model calibration and uncertainty quantification (UQ) principles to an integrated transmission and distribution (T&D) model involving a GFM converter and provide a framework for prioritizing control improvements, guiding robust design, and informing adaptive strategies that can accommodate real-time variability in system conditions. The proposed approach could be valuable in enhancing the robustness of current and future power systems under increased IBR penetrations.
This data set contains the three phase AC voltage, three phase AC current, DC voltage and DC current. These data sets were captured during fuel cell inverter operation in grid-connected dispatch, islanded load changes, transition from grid-connected mode to islanded mode and vice-versa.
This data set shows the operation of the fuel cell inverter under grid-forming mode of operation, grid-following mode of operation and transition between the two modes.
Non-invertible global symmetry often predicts degeneracy in axion potentials and carries important information about the global form of the gauge group. When these symmetries are spontaneously broken they can lead to the formation of stable axion domain wall networks which support topological degrees of freedom on their worldvolume. Such non-invertible symmetries can be broken by embedding into appropriate larger UV gauge groups where small instanton contributions lift the vacuum degeneracy, and provide a possible solution to the domain wall problem. We explain these ideas in simple illustrative examples and then apply them to the Standard Model, whose gauge algebra and matter content are consistent with several possible global structures. Each possible global structure leads to different selection rules on the axion couplings, and various UV completions of the Standard Model lead to more specific relations. As a proof of principle, we also present an example of a UV embedding of the Standard Model which can solve the axion domain wall problem. The formation and annihilation of the long-lived axion domain walls can lead to observables, such as gravitational wave signals. Observing such signals, in combination with the axion coupling measurements, can provide valuable insight into the global structure of the Standard Model, as well as its UV completion.
We initiate the study of supersymmetry-preserving topological defect lines (TDLs) in the Conway moonshine module V f♮ . We show that the tensor category of such defects, under suitable assumptions, admits a surjective but non-injective ring homomorphism into the ring of $\mathbb{Z}$-linear maps of the Leech lattice into itself. This puts strong constraints on possible defects and their quantum dimensions. We describe a simple construction of non-invertible TDLs from orbifolds of holomorphic (super)vertex operator algebras, which yields non-trivial examples of TDLs satisfying our main theorem. We conjecture a correspondence between four-plane-preserving TDLs in V f♮ and supersymmetry-preserving TDLs in K3 non-linear sigma models, which extends the correspondence between symmetry groups to the level of tensor category symmetry. We establish evidence for this conjecture by constructing non-invertible TDLs in special K3 non-linear sigma models.
Laser-driven “inverted corona” fusion targets have attracted interest as a low-convergence neutron source and platform for studying kinetic physics. The scheme consists of a hollow or gas-filled spherical shell made of deuterated plastic. The shell has one or more laser entrance holes (LEH), resembling a spherical hohlraum. The laser passes through the LEH’s and illuminates the interior surface of the shell, ablating a plasma that travels inward towards the target center. Long ion mean free paths in the converging plasma can lead to significant interpenetration, atomic mix, and other kinetic effects. Here, in this work we report on numerical simulations of inverted corona targets using the kinetic-ion, fluid–electron hybrid particle-in-cell (PIC) approach in 2D RZ geometry. 2D simulations suggest that shape effects do not have a significant impact on plasma evolution and observed yield trends are primarily the result of 1D kinetic mix mechanisms. Simulations are also compared against available experimental data recorded at the OMEGA laser facility. In particular, synthetic x-ray emission images show good qualitative agreement with experimental results, albeit with an apparent timing discrepancy for the two-sided vacuum target. More generally, we demonstrate the potential of hybrid-PIC simulations for full-system modeling and experimental design, including collisional absorption of laser energy, plasma evolution, mix, and fusion burn.
2D-on-3D (2D/3D) perovskite heterostructures with engineered energy landscapes offer the potential to realize efficient and stable inverted solar cells. However, managing the energy landscape using 2D perovskites with thicker inorganic layers n > 1 necessitates the usage of the chemically unstable methylammonium MA + . Here, we synthesized formamidinium (FA)-rich and pure-FA n = 3 Ruddlesden-Popper (RPP) and Dion-Jacobson perovskite (DJP) single crystals by identifying ligands with suitably lattice-matched organic and inorganic components of the 2D lattice. These crystals were translated onto 3D perovskites as capping layers, forming 2D/3D hetero-bilayers (HBs). Degradation studies revealed that HBs with butylammonium-based RPPs as capping layers rapidly phase segregate into non-perovskites under combined extrinsic stressors, compromising the underlying 3D layer, whereas FA-rich DJPs based on 3-aminomethylpiperidine retain their phase stability. The DJP HBs also possess a favorable energy landscape and electron transport at the 2D/3D interface, enabling inverted solar cells with a champion PCE of 25.33% and remarkable stability.
Abstract Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar‐low load conditions. The inability of traditional volt‐VAr control in eliminating all the violations is also well‐known. This article presents a novel coordinated inverter control methodology that leverages system‐wide situational awareness to significantly improve hosting capacity (HC). The methodology employs a real‐time voltage‐reactive power (VQ) sensitivity matrix in an iterative linear optimizer to calculate the minimum reactive power intervention from PV inverters needed for mitigating over‐voltage without resorting to active power curtailing or requiring step voltage regulator setting changes. The algorithm is validated using the EPRI J1 feeder under an extensive set of realistic use cases and is shown to provide 3x improvement in HC under all scenarios.
Research on network microgrids has primarily focused on control and optimization. However, application aspects such as microgrid-to-microgrid synchronization have not been fully addressed in existing literature. This paper first addresses the challenges of networking microgrids with grid-forming inverter in droop control. Then, it proposes a pre-synchronization algorithm to improves the synchronization speed and transient stability. To improve the speed, the phase difference between adjacent microgrids is minimized. Transients such as inrush current and oscillations are effectively mitigated by increasing the virtual impedance during interconnection. The proposed strategy allows smooth transitions when reconfiguration of the microgrids is needed. The applicability of this strategy to today’s microgrid systems is demonstrated through a validation in a 480V three-phase network microgrid testbed with commercial-grade inverters, protective devices, and switchgear.