Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Elimination LArTPC Simulation Uncertainty

Liquid Argon Time Projection Chambers (LArTPC) are crucial for measuring muons and neutrinos by capturing the paths of fast-moving particles through argon gas. However, these detectors face challenges such as electron-ion recombination, diffusion, and attenuation, which introduce uncertainties in simulation models. This study, conducted by Ka ren Mkrtchyan at FERMILAB, aims to reduce these uncertainties by adjusting the amplitude and width of signals detected by the TPC wires. Initial findings indicate that the current modification algorithm requires further refinement to better align simulations with observed data. Ongoing work focuses on correcting computational bugs and enhancing the simulation model for improved accuracy and statistical confidence.

Mkrtchyan, Ka'ren↗

Uranium particle age dating, aggregation, and model age best estimators

We present important aspects of uranium particle age dating by Large-Geometry Secondary Ion Mass Spectrometry (LG-SIMS) that can introduce bias and increase model age uncertainties, especially for small, young, and/or low-enriched particles. This metrology is important for applications related to International Nuclear Safeguards. We explore influential factors related to model age estimation, including the effects of evolving surface chemistry on inter-element measurements of particles (e.g., Th and U), detector background, and aggregation methods using simulated and actual particle samples. We introduce a new model age estimator, called “mid68”, that supplements 95% confidence intervals, providing a “best estimate” and uncertainty about the most likely age. The mid68 estimator can be calculated using the Feldman and Cousins method or Bayesian methods and provides a value with a symmetric uncertainty that can be used for calculations and approximate aggregation of processed model age values when the raw data and correction factors are not available. For particles yielding low 230 Th counts amidst nonzero detector background, their underlying model age probability distributions are asymmetric, so the mid68 estimator provides additional robust information regarding the underlying model age likelihood. This study provides a comprehensive and timely examination of critical aspects of uranium particle age dating as more laboratories establish particle chronometry capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for New Physics through a Long-Lived Di-Muon Resonance in the NuMI Beam with the ICARUS Detector

Many of the unexplained phenomena in particle physics and cosmology today, such as the microphysical nature of dark matter, the strong CP problem, and the origin of the neutrino masses, can be resolved by the existence of a light (~GeV), weakly-coupled hidden sector of new physics. Such hidden sectors often predict the existence of “long-lived” particles (LLPs) that travel a far distance from production before decaying into Standard Model particles. Neutrino oscillation experiments, which combine intense particle beams with precise imaging detectors, are well equipped to probe LLP models with new sensitivity. This thesis details a search for a long-lived particle decaying to two muons with the ICARUS liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino program at Fermilab. The calibration of the ICARUS time projection chamber (TPC) which enables the search is also presented. Notably, the calibration measures an angular dependence in electron-ion recombination in argon, a novel effect in the detector physics of LArTPCs. The search is performed using data taken with the Neutrinos at the Main Injector (NuMI) beam, with an exposure of 2.41e20 protons on target. No significant excess over background is observed, and we set world-leading limits on two new physics models that predict this process: the Higgs portal scalar and a heavy axion model. We also present the sensitivity in a model-independent way applicable to any new physics model predicting the process K → π + S(→μμ), for a long-lived particle S.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Upgrades of the ATLAS zero degree calorimeter system for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1, were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with H_2-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; a new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new “Reaction Plane Detectors” (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run 3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run 3.

43 PARTICLE ACCELERATORS↗

Nucleon structure studies: DVCS on polarised protons with the CLAS12 experiment, and development of Micromegas detectors for EIC

The quark and gluon structure of nucleons is crucial for understanding the origin of their mass and spin. This information is encoded in structure function such as Generalised Parton Distributions (GPDs), which provide a three-dimensional picture of the nucleon in terms of its constituents. Deeply Virtual Compton Scattering (DVCS) offers the most direct access to GPDs, but their extraction requires high-precision measurements of multiple observables over a wide kinematic range. In 2022 and 2023 the CLAS12 experiment at Jefferson Lab (JLab) collected data from polarised electron scattering on a longitudinally polarised proton target, enabling the first measurement of polarised DVCS asymmetries at JLab 12GeV kinematics. This thesis will present preliminary measurement of the beam, target and double spin DVCS asymmetries from the CLAS12 polarised proton target data. Nucleon structure studies will also constitute a major part of the physics program at the future Electron Ion Collider (EIC). The development of the first detector at the EIC is ongoing and it requires light Micro-Pattern Gaseous Detectors (MPGDs) for its tracking system. This thesis further reports initial tests of Micromegas MPGDs with a two-dimensional readout developed for EIC.

Polcher, Samy [Univ. Paris-Saclay, Gif-sur-Yvette ↗

Fork Experiments in the Hot Cell Using Spent Fuel Rods for International Nuclear Safeguards

This work leveraged the rare availability of 25 full-length pressurized water reactor spent fuel rods and 1 irradiated mixed-oxide rod at an Oak Ridge National Laboratory hot cell. This was done to collect measurement data with two Fork detectors to assess the detectors’ capability of verifying operator declaration data and detecting partial defects in spent fuel, which are the two primary goals of international safeguards on spent nuclear fuel. The data can also be used to benchmark the ORIGEN module, which has been adopted in the International Atomic Energy Agency’s (IAEA’s)/European Atomic Energy Community’s (Euratom’s) Integrated Review and Analysis Program to predict the Fork detector count rates in real time. In this project, the authors first calibrated two Fork detectors—a standard one and a modified one—by using known strong neutron and gamma sources. Then, the authors measured all 26 fuel rods at multiple locations along the length. The fuel rods were then assembled into three arrays—2 × 2, 3 × 3, and 5 × 5—by using specially designed support grids to mimic fuel assemblies and measure the arrays with both detectors. For the 5 × 5 array, 4 and 8 fuel rods of the array were replaced in two separate cases with short stainless-steel rods to mimic two partial defect scenarios, and the arrays were measured before and after the replacements. Polyethylene blocks were used in this experiment to mimic water. The results show that the Fork detectors were able to verify operator declarations and detect partial defects in spent fuel, and the authors were the first to demonstrate this through experiments. A discovery was also made that determined the root cause of the nonlinear response to gamma dose in the ion chambers used in IAEA and Euratom’s Fork detectors. After the experiments, both detectors were retrieved from the hot cell for future use. The data collected in this project will be used in a parallel International Nuclear Safeguards Engagement Program (INSEP) project to enhance the safeguards in the Finnish spent fuel encapsulation plant, and the data will be useful to other projects in the future given the increased safeguards needs due to spent fuel transfer and disposal activities worldwide.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Future Physics Prospects with the CMS Detector at the High-Luminosity LHC

The High-Luminosity Large Hadron Collider is expected to deliver up to 3000 fb ^{-1} − 1 of proton-proton collisions at 14 TeV center-of-mass energy. We present prospects for selected heavy-ion, Standard Model and Higgs sector measurements with the CMS detector at the HL-LHC, and discuss potential sensitivity to several beyond-Standard Model new physics scenarios.

Henderson, Conor↗

TRANSLATE - a Monte Carlo simulation of electron transport in liquid argon

Here, the microphysics of electron and photon propagation in liquid argon is a key component of detector design and calibrations needed to construct and perform measurements within a wide range of particle physics experiments. As experiments grow in scale and complexity, and as the precision of their intended measurements increases, the development of tools to investigate important microphysics effects impacting such detectors becomes necessary. In this paper we present a new time-domain Monte Carlo simulation of electron transport in liquid argon. The simulation models the TRANSport in Liquid Argon of near-Thermal Electrons (TRANSLATE) with the aim of providing a multi-purpose software package for the study and optimization of detector environments, with a particular focus on ongoing and next generation liquid argon neutrino experiments utilizing the time projection chamber technology. TRANSLATE builds on previous work of Wojcik and Tachiya, amongst others, introducing additional processes, including ionization, thus modeling the full range of drift electron scattering interactions. The simulation is validated by benchmarking its performance with swarm parameters from data collected in experimental setups operating in gas and liquid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid MEMS-CMOS ion traps for NISQ computing

Surging interest in engineering quantum computers has stimulated significant and focused research on technologies needed to make them manufacturable and scalable. In the ion trap realm this has led to a transition from bulk three-dimensional macro-scale traps to chip-based ion traps and included important demonstrations of passive and active electronics, waveguides, detectors, and other integrated components. At the same time as these technologies are being developed the system sizes are demanding more ions to run noisy intermediate scale quantum (NISQ) algorithms, growing from around ten ions today to potentially a hundred or more in the near future. To realize the size and features needed for this growth, the geometric and material design space of microfabricated ion traps must expand. In this paper we describe present limitations and the approaches needed to overcome them, including how geometric complexity drives the number of metal levels, why routing congestion affects the size and location of shunting capacitors, and how RF power dissipation can limit the size of the trap array. Finally, we also give recommendations for future research needed to accommodate the demands of NISQ scale ion traps that are integrated with additional technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Design and performance of the Fermilab Constant Fraction Discriminator ASIC

Here, we present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of evolving time-walk corrections throughout the operational lifetime of the detector system. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for LGAD signals with charge ranging between 5 and 26 fC has been measured to vary no more than 10ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is found to be 10ps for signals with charge above 20fC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the ProtoDUNE Horizontal-Drift position reconstruction using a laser system

Forthcoming in the next decade of neutrino physics advancements is the construction of the Deep Underground Neutrino Experiment (DUNE), a long baseline neutrino oscillation experiment which has the potential to answer fundamental questions such as why there is more matter than antimatter in the universe, and ultimately why we exist at all. A prototype of this experiment, ProtoDUNE, sits in a charged particle test beam at the European Organization for Nuclear Research (CERN) and uses Liquid Argon time projection chambers to image interactions of these particles. ProtoDUNE Single-Phase (ProtoDUNESP) had positively charged hadrons as well as positrons in its initial 2018 beam data run. Because ProtoDUNE is a surface-based time projection chamber, it experiences a constant influx of cosmic rays. These cosmic rays ionize the liquid argon within the detector, resulting in an accumulation of slow moving positive ions towards the cathode. This local charge distribution results in electric field non uniformities, which can have a significant effect on the accuracy of the event reconstruction. This paper outlines a monte carlo simulation study which adapts methodology from the MicroBooNE experiment, another neutrino oscillation experiment, to derive electric field correction maps which can correct for distortions of the electric field within the detector. These correction maps accurately estimate the electric field throughout the detector volume and correct for uncertainties in reconstructed event data enabling for physics discoveries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Timelike Compton Scattering from a longitudinally polarised target with CLAS12 at Jefferson Lab

Explorations into the internal dynamics of hadrons are constantly evolving, and the requirement for experimental results to verify theoretical models of hadron structure is paramount. A key area in this field is the study of Generalised Parton Distributions (GPDs), which are functions used to model the momenta of quarks and gluons within hadrons, and the methods to access GPDs experimentally. One such scattering process that allows access to these is Timelike Compton Scattering. TCS complements existing Deeply Virtual Compton Scattering experiments and allows investigation into the universality of GPDs through access to the real and imaginary parts of the parton helicity independent GPD Hq via beam spin asymmetries (BSA), and it provides novel access to the real and imaginary parts of the parton helicity dependent GPD ˜Hq through target polarisation asymmetries (TSA). This thesis work presents a comparative study with the first published BSA for TCS at the Thomas Jefferson National Accelerator Facility (JLab), alongside a first time extraction of a Target Spin Asymmetry with the Summer 2022 data taking run. JLab hosts the Continuous Electron Beam Accelerator Facility (CEBAF) which provides a 12 GeV electron beam to four experimental halls. Hall-B contains the CEBAF Large Acceptance Spectrometer, which took data across three run periods on a longitudinally polarised NH3 and ND3 fixed target from 2022-2023, to extract measurements of electron-proton scattering, from which a TCS signal could be extracted. The thesis discusses work done to understand and eliminate contributions from the non-/low-polarised nuclear background, testing pre-established cuts to eliminate pion background from a dilepton (e+e-) final state and modifying them as needed for the new experimental run, and attempts to hone in on a clean TCS signal from which to extract the two asymmetry observables. A comparison with existing BSA results was performed; however, the statistical errors are too large to draw a significant conclusion as to whether there is agreement across each bin. More data is needed for a multidimensionally binned extraction. A proof of principle was achieved in the TSA measurements, with two out of four kinematic bins showing preliminary agreement in shape with theoretical values. Again, the errors are significant due to the contributions from the nuclear background. To support these conclusions, a further study was done, which takes into account an estimate of the asymmetries with the full available dataset (this thesis is based only on data taken in the summer set; at the time of writing processing was still being conducted for the final two datasets), as well as an estimate including additional future experiment days that were awarded in July 2024. Additional work was done on a secondary project exploring the feasibility of measuring TCS at the upcoming Electron Ion Collider, supporting the design proposal for the detector for the first interaction region and giving a positive outlook for the future of these types of measurements beyond JLab.

Gates, Kayleigh [Univ. of Glasgow, Scotland (Unite↗

Detector requirements and simulation results for the EIC exclusive, diffractive and tagging physics program using the ECCE detector concept

This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC’s exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark–gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detector system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirm the proposed technology and design satisfy the requirements. Further, the projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb -1 of integrated luminosity. Additionally, insights related to a potential second EIC detector are documented, which could serve as a guidepost for future development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A suite of neutron time-of-flight detectors to measure hot-spot motion in direct-drive inertial confinement fusion experiments on OMEGA

A suite of six neutron time of flight detectors capable of measuring the primary DT neutron energy spectrum has recently been completed on the OMEGA Laser System. The detectors are positioned along multiple quasi-orthogonal lines of sight (LOS’s) in either a stand-alone, collinear, or antipodal configuration. The collinear detector configuration enables one to measure the neutron velocity along the detector LOS independent of the neutron-production history, while the antipodal detector configuration enables one to directly measure of the hot-spot velocity along the detector axis and Gamow velocity shift due to the plasma ion temperature. Using these six measurements of the primary DT neutron energy spectrum, the neutron-averaged hot-spot velocity and Gamow velocity shift of DT fusion neutrons have been measured in cryogenic experiments on OMEGA for the first time. Finally, the detector suite is operable between DT neutron yields of 1 × 10 13 to 2 × 10 14 with an uncertainty of ~14 km/s in the neutron-averaged hot-spot velocity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Slicing Newton spheres with a two-camera 3D imaging system

We demonstrate a simple approach to achieve three-dimensional ion momentum imaging. The method employs two complementary metal–oxide–semiconductor cameras in addition to a standard microchannel plates/phosphor screen imaging detector. The two cameras are timed to measure the decay of luminescence excited by ion hits to extract the time of flight. The achieved time resolution is better than 10 ns, which is mainly limited by camera jitters. A better than 5 ns resolution can be achieved when the jitter is suppressed.

Chemistry↗