Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Comparison of Mg-based liquid metal ion sources for scalable focused-ion-implantation doping of GaN

We compare the suitability of various magnesium-based liquid metal alloy ion sources (LMAISs) for scalable focused-ion-beam (FIB) implantation doping of GaN. We consider GaMg, MgSO 4 $\bullet$7H 2 O, MgZn, AlMg, and AuMgSi alloys. Although issues of oxidation (GaMg), decomposition (MgSO 4 $\bullet$7H 2 O), and excessive vapor pressure (MgZn and AlMg) were encountered, the AuMgSi alloy LMAIS operating in a Wien-filtered FIB column emits all Mg isotopes in singly and doubly charged ionization states. We discuss the operating conditions to achieve <20 nm spot size Mg FIB implantation and present Mg depth profile data from time-of-flight secondary ion mass spectrometry. We also provide insight into implantation damage and recovery based on cathodoluminescence spectroscopy before and after rapid thermal processing. Prospects for incorporating the Mg LMAIS into high-power electronic device fabrication are also discussed.

36 MATERIALS SCIENCE↗

A status report of the multipurpose superconducting electron cyclotron resonance ion source (invited)

Intense heavy ion beam production with electron cyclotron resonance (ECR) ion sources is a common requirement for many of the accelerators under construction in Europe and elsewhere. An average increase of about one order of magnitude per decade in the performance of ECR ion sources was obtained up to now since the time of pioneering experiment of R. Geller at CEA, Grenoble, and this trend is not deemed to get the saturation at least in the next decade, according to the increased availability of powerful magnets and microwave generators. Electron density above 10{sup 13} cm{sup -3} and very high current of multiply charged ions are expected with the use of 28 GHz microwave heating and of an adequate plasma trap, with a B-minimum shape, according to the high B mode concept [S. Gammino and G. Ciavola, Plasma Sources Sci. Technol. 5, 19 (1996)]. The MS-ECRIS ion source has been designed following this concept and its construction is underway at GSI, Darmstadt. The project is the result of the cooperation of nine European institutions with the partial funding of EU through the sixth Framework Programme. The contribution of different institutions has permitted to build in 2006-2007 each component at high level of expertise. The description of the major components will be given in the following with a view on the planning of the assembly and commissioning phase to be carried out in fall 2007. An outline of the experiments to be done with the MS-ECRIS source in the next two years will be presented.

43 PARTICLE ACCELERATORS↗

Molecular and negative ion production by a standard electron cyclotron resonance ion source

Molecular and negative ion beams, usually produced in special ion sources, play an increasingly important role in fundamental and applied atomic physics. The ATOMKI-ECRIS is a standard ECR ion source, designed to provide highly charged ion (HCI) plasmas and beams. In the present work, H{sup -}, O{sup -}, OH{sup -}, O{sub 2}{sup -}, C{sup -}, C{sub 60}{sup -} negative ions and H{sub 2}{sup +}, H{sub 3}{sup +}, OH{sup +}, H{sub 2}O{sup +}, H{sub 3}O{sup +}, O{sub 2}{sup +} positive molecular ions were generated in this HCI-ECRIS. Without any major modification in the source and without any commonly applied tricks (such as usage of cesium or magnetic filter), negative ion beams of several {mu}A and positive molecular ion beams in the mA range were successfully obtained.

43 PARTICLE ACCELERATORS↗

Investigations on caesium-free alternatives for H{sup −} formation at ion source relevant parameters

Negative hydrogen ions are efficiently produced in ion sources by the application of caesium. Due to a thereby induced lowering of the work function of a converter surface a direct conversion of impinging hydrogen atoms and positive ions into negative ions is maintained. However, due to the complex caesium chemistry and dynamics a long-term behaviour is inherent for the application of caesium that affects the stability and reliability of negative ion sources. To overcome these drawbacks caesium-free alternatives for efficient negative ion formation are investigated at the flexible laboratory setup HOMER (HOMogenous Electron cyclotron Resonance plasma). By the usage of a meshed grid the tandem principle is applied allowing for investigations on material induced negative ion formation under plasma parameters relevant for ion source operation. The effect of different sample materials on the ratio of the negative ion density to the electron density n{sub H{sup −}} /n{sub e} is compared to the effect of a stainless steel reference sample and investigated by means of laser photodetachment in a pressure range from 0.3 to 3 Pa. For the stainless steel sample no surface induced effect on the negative ion density is present and the measured negative ion densities are resulting from pure volume formation and destruction processes. In a first step the dependency of n{sub H{sup −}} /n{sub e} on the sample distance has been investigated for a caesiated stainless steel sample. At a distance of 0.5 cm at 0.3 Pa the density ratio is 3 times enhanced compared to the reference sample confirming the surface production of negative ions. In contrast for the caesium-free material samples, tantalum and tungsten, the same dependency on pressure and distance n{sub H{sup −}} /n{sub e} like for the stainless steel reference sample were obtained within the error margins: A density ratio of around 14.5% is measured at 4.5 cm sample distance and 0.3 Pa, linearly decreasing with decreasing distance to 7% at 1.5 cm. Thus, tantalum and tungsten do not significantly affect the negative ion density. First measurements conducted with LaB{sub 6} as well as with two types of diamond like carbon (DLC) n{sub H{sup −}} /n{sub e} of about 15% at 1 Pa were measured, which is comparable to the density ratio obtained for the stainless steel reference sample. At HOMER a surface induced enhancement of n{sub H{sup −}} is only observed when it exceeds the volume formation of H{sup −} which is also realistic for negative hydrogen ion sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarized ion sources: Status and perspectives

Modern polarized ion sources generate polarized ion beams with high intensity and polarization. Mainly, atomic beam-type and optically pumped polarized ion sources are used to provide polarized ion beams to accelerators. Principles of both methods are outlined in the paper. Characteristics as well as possible improvements of polarized ion sources are considered.

43 PARTICLE ACCELERATORS↗

Solid-State Laser, Resonant Ionization Laser Ion Source (Rilis) and Laser Beam Transport at Radioactive Ion Beam Facilities

The inception of laser resonance ionization spectroscopy and its application as a resonant ionization laser ion source (RILIS) took place merely 20 years ago with pulsed dye lasers [1-5]. By now next generation radioactive ion beam (RIB) facilities are being planned or built. Understanding and considering the unique RILIS requirements in the layout of next generation RIB facilities will allow for cost-effective implementation of this versatile ion source. This discussion touches on laser beam transport and RILIS requirements not necessarily obvious to experts in conventional ion sources.

43 PARTICLE ACCELERATORS↗

Systematic Ion Source Parameter Assessment by Automated Determination of the Distribution of Ion Acceptance (DIA) Using APLI

The determination of the spatially resolved ion signal with atmospheric pressure laser ionization (APLI), which was introduced as distribution of ion acceptance (DIA), serves as a valuable tool for the understanding of complex and highly dynamical conditions in modern atmospheric pressure (AP) ion sources. DIA provides information about fluid dynamics, ion transport, and ion transformation processes in such sources and is an ideal basis for the validation of numerical models of the dynamics in the ion source enclosure. We present a fully automated setup for DIA measurements, which enabled us to acquire a comprehensive dataset of over 700 individual DIA measurements in a commercial AP ion source (Bruker Multi Purpose Ion Source, MPIS). Ion source parameters as voltages, gas heater temperatures and gas flows, were varied, and the effect of those parameters on the DIA of a chemically inert analyte, pyrene, was systematically investigated. It is shown that the response of the DIA is nonlinear and that gas dynamics largely dominates the ion transport in the ion source. Particularly, the position of the heated nebulizer, which is used to introduce one of two gas flows and the analyte into the ion source chamber, had a profound effect on the DIA. This suggests that the gas dynamics in the source switches between different states. The now available comprehensive DIA dataset reveals such critical effects and will guide further numerical modeling efforts to understand the details of the dynamics of ions in the source chamber. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Electric Potential Near The Extraction Region In Negative Ion Sources With Surface Produced Negative Ions

The potential distribution near the extraction region in negative ion sources for the plasma with the surface produced negative ions is studied analytically. The potential is derived analytically by using a plasma-sheath equation, where negative ions produced on the Plasma Grid (PG) surface are considered in addition to positive ions and electrons. A negative potential peak is formed in the sheath region near the PG surface for the case of strong surface production of negative ions or for low energy negative ions. Negative ions are reflected by the negative potential peak near the PG and returned to the PG surface. This reflection mechanism by the negative potential peak possibly becomes a factor in negative ion extraction. It is also indicated that the potential difference between the plasma region and the wall decreases by the surface produced negative ions. This also has the possibility to contribute to the negative ion extraction.

43 PARTICLE ACCELERATORS↗

Negative hydrogen ion beam extracted from a Bernas-type ion source

Negative hydrogen (H{sup -}) ion beam was produced without cesium seeding by a Bernas-type ion source with a coaxial hot cathode. The amount of H{sup -} ion beam current extracted from an original Bernas-type ion source using a hairpin shape filament as a hot cathode was 1 {mu}A with the 0.4 A arc current, while that 300 eV beam energy. In the other hand, H{sup -} ion beam current using the Bernas-type ion source with a coaxial hot cathode reached 4 {mu}A under the same condition. Production efficiency was enhanced by the focused plasma produced by a coaxial hot cathode.

43 PARTICLE ACCELERATORS↗

Modeling of the rf discharge initiation in a negative ion source

The maintenance free rf ion source is expected to be one of the most promising candidates for the negative ion sources of plasma heating for future fusion reactors. As an alternative to the arc-discharge sources, the rf negative ion sources have been developed for H{sup -} production. In order to make clear the condition for the discharge initiation of the rf source, we are developing a numerical model using the finite difference time domain Monte Carlo method to analyze the electron energy distribution function in rf field. The numerical result shows that the discharge is not successfully initiated due to the wall loss unless the wall potential is considered. More self-consistent model including ion dynamics to evaluate the wall potential and the electron loss at the wall will be needed in the future.

43 PARTICLE ACCELERATORS↗

Numerical study of the characteristics of the ion and fast atom beams in an end-Hall ion source

An end-Hall ion source is a cylindrical magnetized device of few centimeters in length able to generate an ion beam with a current of typically 1 A and ion energies in the range of 100 eV. This ion source does not use acceleration grids, has a relatively large ion beam divergence, and is well suited for ion assisted deposition processes. In this paper, a self-consistent two-dimensional quasi-neutral model of an end-Hall ion source is used to understand the parameters controlling the characteristics of the extracted. The model results underline the role of charge exchange collisions on beam properties. The calculated energy distribution functions reveal the existence of groups of slow ions and fast neutrals. Ion mean energy corresponds to roughly 60% of the discharge voltage, while the root mean square deviation from the mean energy corresponds to about 33% of the discharge voltage, as in experiments. The influence of the position of the electron emitting source on the ion angular distribution is also shown.

43 PARTICLE ACCELERATORS↗

Operation of Lanzhou all permanent electron cyclotron resonance ion source No. 2 on 320 kV platform with highly charged ions

The 320 kV platform for multi-discipline research with highly charged ions is a heavy ion beam acceleration instrument developed by Institute of Modern Physics, which is dedicated to basic scientific researches such as plasma, atom, material physics, and astrophysics, etc. The platform has delivered ion beams of 400 species for 36 000 h. The average operation time is around 5000 h/year. With the beams provided by the platform, lots of outstanding progresses were made in various research fields. The ion source of the platform is an all-permanent magnet electron cyclotron resonance ion source, LAPECR2 (Lanzhou All Permanent ECR ion source No. 2). The maximum axial magnetic fields are 1.28 T at injection and 1.07 T at extraction, and the radial magnetic field is up to 1.21 T at the inner wall of the plasma chamber. The ion source is capable to produce low, medium, and high charge state gaseous and metallic ion beams, such as H{sup +}, {sup 40}Ar{sup 8+}, {sup 129}Xe{sup 30+}, {sup 209}Bi{sup 33+}, etc. This paper will present the latest result of LAPECR2 and the routine operation status for the high voltage platform.

43 PARTICLE ACCELERATORS↗

Operation Status of the J-PARC Negative Hydrogen Ion Source

A cesium-free negative hydrogen ion source driven with a lanthanum hexaboride (LaB{sub 6}) filament is being operated without any serious trouble for approximately four years in J-PARC. Although the ion source is capable of producing an H{sup -} ion current of more than 30 mA, the current is routinely restricted to approximately 16 mA at present for the stable operation of the RFQ linac which has serious discharge problem from September 2008. The beam run is performed during 1 month cycle, which consisted of a 4-5 weeks beam operation and a few days down-period interval. At the recent beam run, approximately 700 h continuous operation was achieved. At every runs, the beam interruption time due to the ion source failure is a few hours, which correspond to the ion source availability of more than 99%. The R and D work is being performed in parallel with the operation in order to enhance the further beam current. As a result, the H{sup -} ion current of 61 mA with normalized rms emittance of 0.26 {pi}mm.mrad was obtained by adding a cesium seeding system to a J-PARC test ion source which has the almost same structure with the present J-PARC ion source.

43 PARTICLE ACCELERATORS↗

Study on high-flux laser ion source with applying magnetic field

The laser ion source is a technology where by irradiating a solid target with a pulsed laser of high intensity (10 8 W/cm 2 ~), ablation plasma is generated, and by applying there an external electric field for extracting and accelerating ions, high brightness ion beams are produced. This paper introduced the basic features of laser ion source and recent movement of the control of laser ion source using magnetic field. In the development of heavy ion inertial fusion (HIF) driver, engineers are challenging new tasks of supplying low valence, large current, and low emittance beams. In order to respond to the requirements of large current beams in HIF driver, attempts have been made to control the plasma via magnetic field to further increase the flux. The current of the laser ion source with application of solenoid magnetic field is dramatically improved and its amplification magnification can be adjusted by changing the position, length, and magnetic flux density of the solenoid. In order to further control the laser ion source toward HIF, the authors propose the guiding of plasma via multiple cusp magnetic field, and the guiding effect is being demonstrated through examination. According to the studies so far, the laser ion source can supply ion beams using a simple configuration, so it is suitable for miniaturization and may be adopted at many accelerator facilities. (A.O.)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited)

With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A new regulation method of stable operation of high power cathode ion source

The hot cathode ion source will tend to be unstable when operated with high power and long pulse. In order to achieve stable operation, a new regulation method based on the arc power (discharge power) feedback control was designed and tested on the hot cathode ion source test bed with arc discharge and beam extraction. The results show that the new regulation method can achieve stable arc discharge and beam extraction. It verifies the success of feedback control of arc source with arc power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗