Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Factors affecting ion kinetic temperature, number density, and containment time in the NASA Lewis bumpy-torus plasma

The degree of toroidal symmetry of the plasma, the number of midplane electrode rings, the configuration of electrode rings, and the location of the diagnostic instruments with respect to the electrode rings used to generate the plasma are discussed. Impurities were deliberately introduced into the plasma, and the effects of the impurity fraction on ion kinetic temperature and electron number density were observed. It is concluded that, if necessary precautions are taken, the plasma communicates extremely well along the magnetic field lines and displays a high degree of symmetry from sector to sector for a wide range of electrode ring configurations and operating conditions. Finally, some characteristic data taken under nonoptimized conditions are presented, which include the highest electron number density and the longest particle containment time (1.9 msec) observed. Also, evidence from a paired comparison test is presented which shows that the electric field acting along the minor radius of the toroidal plasma improves the plasma density and the calculated containment time more than an order of magnitude if the electric field points inward, relative to the values observed when it points (and pushes ions) radially outward.

Roth, J. R.↗

Isotope dependence of transport in ST40 hot ion mode plasmas

The ST40 compact, high-field spherical tokamak, operating at 2.1 T and with 1.8 MW of neutral beam heating, achieved central carbon impurity ion temperatures in excess of 10 keV, surpassing their business milestone of 100 M °C (8.6 keV). The high temperature discharges were in the hot ion mode, with $T_i \gg T_e$, and they were achieved in both hydrogen and deuterium plasmas with deuterium neutral beam injection. In order to achieve the high temperature scenarios, careful wall conditioning and scenario optimization was carried out in $H^0 \rightarrow H^+$, $D^0 \rightarrow H^+$, and finally in $D^0 \rightarrow D^+$ plasmas. The TRANSP transport code was employed to study the dependence of confinement and transport on isotopic mass, and the conditions that led to the high measured central ion temperatures in the $D^0 \rightarrow H^+$ and $D^0 \rightarrow D^+$ plasmas. The kinetic profiles input into TRANSP were inferred from line-of-sight and limited radial measurements as well as consistency with a number of other experimental constraints. The TRANSP results first showed that the main species central ion temperature was only 0.5–1 keV lower than the measured carbon impurity temperature, and thus in the high performance plasmas also surpassed the 100 M °C level. TRANSP also showed that while the electron thermal conduction loss was dominant, reductions in central ion transport, and an effective decoupling of the ions from the electrons, led to an increase in central ion temperatures with increasing plasma mass. In fact, the associated confinement times exhibited a strong dependence on the isotopic mass of the thermal plasma. These preliminary results are foundations for dedicated experiments with full kinetic profile measurements on ST40 in the next run campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hot ion plasma production in HIP-1 using water-cooled hollow cathodes

A steady-state ExB plasma was formed by applying a strong radially inward dc electric field near the mirror throats. Most of the results were for hydrogen, but deuterium and helium plasmas were also studied. Three water-cooled hollow cathodes were operated in the hot-ion plasma mode with the following results: (1) thermally emitting cathodes were not required to achieve the hot-ion mode; (2) steady-state operation (several minutes) was attained; (3) input powers greater than 40 kW were achieved; (4) cathode outside diameters were increased from 1.2 cm (uncooled) to 4.4 cm (water-cooled); (5) steady-state hydrogen plasma with ion temperatures from 185 to 770 eV and electron temperatures from 5 to 21 eV were produced. Scaling relations were empirically obtained for discharge current, ion temperature, electron temperature, and relative ion density as a function of hydrogen gas feed rate, magnetic field, and cathode voltage. Neutrons were produced from deuterium plasma, but it was not established whether thay came from the plasma volume or from the electrode surfaces.

Reinmann, J. J.↗

Hot ion plasma production in HIP-1 using water-cooled hollow cathodes

The paper reports on hot-ion plasma experiments conducted in a magnetic mirror facility. A steady-state E x B plasma was formed by applying a strong radially inward dc electric field near the mirror throats. Most of the results were for hydrogen, but deuterium and helium plasmas were also studied. Three water-cooled hollow cathodes were operated in the hot-ion plasma mode with the following results: (1) thermally emitting cathodes were not required to achieve the hot-ion mode; (2) steady-state operation (several minutes) was attained; (3) input powers greater than 40 kW were achieved; (4) cathode outside diameters were increased from 1.2 cm (uncooled) to 4.4 cm (water-cooled); (5) steady-state hydrogen plasmas with ion temperatures from 185 to 770 eV and electron temperatures from 5 to 21 eV were produced. Scaling relations were empirically obtained for discharge current, ion temperature, electron temperature, and relative ion density as a function of hydrogen gas feed rate, magnetic field, and cathode voltage.

Reinmann, J. J.↗

The effect of discharge chamber wall temperature on ion thruster performance

Experiments conducted on a ring cusp ion thruster that could be maintained at temperatures in the range 80 K to 500 K during operation by cooling it with liquid nitrogen are described. The measured changes in performance induced by discharge chamber wall temperature changes are compared to those predicted by a simple discharge chamber model. Good agreement between the temperature induced effects predicted by the model and measured results are demonstrated. Decreases in wall temperature to about 90 K are shown to effect substantial improvements in performance.

Wilbur, P. J.↗

Microscopic filamentation due to electrothermal instability and plasma heating in time-dependent solar transition layer

Nonlinear equilibrium states of a microscopic current filamentation (electrothermal instability) in the solar atmosphere are explored. This phenomenon occurs for transition zone ion temperature plasmas provided that the electron to ion temperature ratio exceeds 1. It is shown that when the onset condition for the electrothermal instability is satisfied, the instability drives a current filamentation to a nonlinear equilibrium state that has a spatially periodic electron temperature variation with wavelength.

Hinata, Satoshi↗

A two-dimensional model of the ionosphere of Venus - Thermal structure

A spectral model is defined for the electron and ion temperature profiles of the Venus ionosphere. The model is developed using data collected with the retarding potential analyzer on the Pioneer Venus Orbiter, and account is taken of horizontal bulk heat transport and a heat flux saturation effect. Coupled ion and energy equations and thermal flux equations are defined. A finite difference algorithm is applied to solve the equations, assuming an ionopause at 740 km altitude. Horizontal plasma flow velocities of 2.5-5.6 km/sec are found necessary in order to account for a dip in the ion temperature around the terminator and a sharp rise at about 140 deg, i.e., far past the solar zenith angle. An external heat source of 0.0001-0.0002 ergs/sq cm per sec, uniformly distributed around Venus, is required to maintain observed dayside and nightside ion temperatures. The heat source may be the solar wind, which would be sufficient without shocks.

Singhal, R. P.↗

Metallic glass as a temperature sensor during ion plating

The temperature of the interface and/or a superficial layer of a substrate during ion plating was investigated using a metallic glass of the composition Fe67Co18B14Si1 as the substrate and as the temperature sensor. Transmission electron microscopy and diffraction studies determined the microstructure of the ion-plated gold film and the substrate. Results indicate that crystallization occurs not only in the film, but also in the substrate. The grain size of crystals formed during ion plating was 6 to 60 nm in the gold film and 8 to 100 nm in the substrate at a depth of 10 to 15 micrometers from the ion-plated interface. The temperature rise of the substrate during ion plating was approximately 500 C. Discontinuous changes in metallurgical microstructure, and physical, chemical, and mechanical properties during the amorphous to crystalline transition in metallic glasses make metallic glasses extremely useful materials for temperature sensor applications in coating processes.

Miyoshi, K.↗

Metallic glass as a temperature sensor during ion plating

The temperature of the interface and/or a superficial layer of a substrate during ion plating was investigated using a metallic glass of the composition Fe67Co18B14Si1 as the substrate and as the temperature sensor. Transmission electron microscopy and diffraction studies determined the microstructure of the ion-plated gold film and the substrate. Results indicate that crystallization occurs not only in the film, but also in the substrate. The grain size of crystals formed during ion plating was 6 to 60 nm in the gold film and 8 to 100 nm in the substrate at a depth of 10 to 15 micrometers from the ion-plated interface. The temperature rise of the substrate during ion plating was approximately 500 C. Discontinuous changes in metallurgical microstructure, and physical, chemical, and mechanical properties during the amorphous to crystalline transition in metallic glasses make metallic glasses extremely useful materials for temperature sensor applications in coating processes.

Miyoshi, K.↗

Neutron yield enhancement and suppression by magnetization in laser-driven cylindrical implosions

In inertial confinement fusion, an externally applied magnetic field can reduce heat losses in the compressing fuel thereby increasing neutron-averaged ion temperatures and neutron yields. Yet, magnetization is only beneficial if the magnetic pressure remains negligible compared to the fuel pressure. Experiments and three-dimensional magneto-hydrodynamic simulations of cylindrical implosions on the OMEGA laser show ion temperature and neutron yield enhancements of up to 44% and 67%, respectively. As the applied, axial magnetic field is increased to nearly 30T, both experiments and simulations show yield degradation. For magnetized, cylindrical implosions, there exists an optimal magnetic field that maximizes the increase in yield. Limiting the fuel convergence ratio by preheating the fuel can further increase the benefit of magnetization. The findings demonstrate that it is possible to create a plasma with a density of order 1 g/cm 3 and an ion temperature greater than 1 keV with a magnetic pressure comparable to the thermal pressure, a new regime for laser-produced plasmas on OMEGA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Turbulence-reduced high-performance scenarios in Wendelstein 7-X

In the Wendelstein 7-X (W7-X) stellarator, turbulence is the dominant transport mechanism in most discharges. This leads to a 'clamping' of ion temperature over a wide range of heating power, predominantly flat density profiles where hollow profiles driven by neoclassical thermo-diffusion would be expected and by rapid impurity transport in injection experiments. Significantly reduced turbulent transport is observed in the presence of strong core density gradients found transiently after core pellet injection and irregularly after boronisation or boron pellet injection. Density peaking is also achieved in a controlled manner in purely neutral beam heated discharges where particle transport analysis reveals an abrupt reduction in the main-ion particle flux leading to significant density profile peaking not explained by the NBI particle source alone. The plasmas exhibit a heat diffusivity of around $\chi = 0.25 \pm 0.1\,\mathrm{m}^2\ \mathrm{s}^{-1}$ at mid radius, a factor of around 4 lower than ECRH dominated discharges. Despite the improved confinement, the achieved ion temperature is limited by broader heat deposition and the lower power-per-particle given the higher density. This is overcome with limited reintroduction of ECRH power, where the low heat diffusivity diffusivity is maintained, the density rise supressed and ion temperatures above the clamping limit are achieved. The applicability of these plasmas for a high performance scenario on transport relevant time scales is assessed, including initial predictions for planned heating upgrades of W7-X, based on a range of assumptions about particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Solar activity variation of ionospheric plasma temperatures

The present status of understanding and modeling of the variation of electron and ion temperatures with solar activity is reviewed. All atmospheric and ionospheric densities and temperatures are positively correlated with solar activity except the electron temperature, which exhibits a rather complex variation pattern during a solar cycle. The ion temperature at low altitudes closely follows the variation patterns of the neutral temperature. The electron temperature at high altitudes increases with increasing solar activity; the increase is larger during day than during night and exhibits a latitudinal variation. At low altitudes during daytime, tha amplitude of the seasonal variation of the electron temperature increases toward the solar maximum. At 400 km during daytime, the summer electron temperatures for Millstone Hill increase slightly toward higher solar activities, whereas the winter temperatures decrease distinctly. For Arecibo, an opposite trend is noticeable.

Bilitza, D.↗

Survey of electron and ion bulk flows in the distant magnetotail with the Geotail spacecraft

A histogramic survey is reported for the electron and ion bulk flows in Earth's magnetotail at geocentric radial distances in the range of about 10 to 210 R(sub E) from the Comprehensive Plasma Instrumentation on board the Geotail spacecraft. Specifically the X-components of the bulk flows are examined for high ion temperatures, greater than 5 x 10(exp 6) K, and for the lower ion temperatures. This separation of plasmas provides a reasonably effective criterion for identifying the hot plasmas associated with the plasma sheet and its boundary layers and the colder plasmas found in the magnetotail lobes and magnetopause boundary layer. The survey shows that the distributions of earthward bulk flows of ions and electrons are similar for each of the two temperature regimes, respectively. However, average speeds for the ions and electrons as a function of radial distance are dissimilar in that the electron bulk speeds are greater than those for the ions. All average electron and ion bulk flows are directed tailward at geocentric radial distances greater than 30 R(sub E). The most striking dissimilarity in the occurrence frequencies of the bulk flows is the large number with high tailward speeds for the electrons, greater than 500 km/s, relative to those for the ions. It is found that the disparity in bulk flows is due to the presence of two ion velocity distributions, one with high temperatures and a bulk speed similar to that of the electrons and the second, colder distribution with higher number density and considerably lesser bulk flow speed.

Frank, L. A.↗

Dynamic tunability of phase-change material transition temperatures using ions for thermal energy storage

Thermal energy storage (TES) based on phase-change materials (PCMs) has many current and potential applications, such as climate control in buildings, thermal management for batteries and electronics, thermal textiles, and transportation of pharmaceuticals. Despite its promise, the adoption of TES has been limited, in part due to limited tunability of the transition temperature, which hinders TES performance for varying use temperatures. Transition temperature tuning of a material using an external stimulus, such as pressure or an electric field, typically requires very large stimuli. To circumvent this problem, here, we report on the dynamic transition temperature tunability of a PCM using ions. We achieve a transition temperature tunability up to 6°C in polyethylene glycol (PEG) by using the salt lithium oxalatodifluoroborate at a low voltage of 2.5 V, which may enable simpler and safer devices/system designs. We also explain the thermal properties of the salt/PCM solution using the Flory-Huggins theory.

25 ENERGY STORAGE↗