At least 199 records · Page 11

Progress on the Plasmoid Thruster Experiment (PTX)

A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic field (B(sub p) and B(sub t), respectively). An object with B(sub p)/B(sub t), much much more than 1 is called a Field Reverse Configuration (FRC); if B(sub p) approximately equal to B(sub t), it is called a Spheromak. The thruster operates by repetitively producing plasmoids that are accelerated and ejected at high velocity. As this process is inductive, there are no electrodes. Also, the magnetic structure of the plasmoid should suppress thermal and mass losses to the wall, and improve detachment of the plasma exhaust from the thruster. This concept should be capable of producing an Isp in the range of 5,000 - 10,000 s with thrust densities of order 10(exp 5) N per square meters. The current experiment is designed to produce jet powers in the range of 5-10 kW, although the concept should be scalable into the MW range. In PTX, the plasmoid is formed inside of a single turn conical theta-pinch coil (17.58 cone angle). The coil is driven by a 640 nF, 35 kV capacitor bank, which rings at a frequency of 500 kHz. Previous experiments on PTX were conducted with a static-fill of propellant gas (6% H2 in He), and demonstrated reliable ionization over a pressure range of 40 - 200 mTorr. We are now adding a fast gas-puff valve to load the propellant, and a ringing pre-ionization circuit (f = 5 Mhz) to better control the plasmoid formation. An alternate coil (8.58 cone angle) will also be used, so as to investigate the effect of coil shape on performance. In addition, a variety of propellants will be used, including hydrogen, nitrogen, and argon. The plasmoid mass and velocity will be measured with a variety of diagnostics, including external B-dot probes and flux loops, a high-speed framing camera, and a HeNe laser interferometer. Internal B-dot probes and a quadruple Langmuir probe will provide additional measurements of the plasmoid shape and structure, as well as density, and will be described in a companion paper. The experimental results will be compared to calculations made using a 0-D coil-gun model and also a 2-D time dependent MHD code.

Martin, Adam↗

Near Field Probe Measurements in the Plume of a NEXT Ion Thruster

Due to the extremely long lifetime and ground testing complications, such as facility backpressure effects, modeling is a necessary tool for validating mission lifetime requirements. Both NASA's Glenn Research Center and Jet Propulsion Laboratory have developed lifetime validation models for the NEXT ion thruster. The largest uncertainties in these models are due to unknown plasma properties, such as plasma potential, that occur very near to the grid. Previous studies have made measurements in the mid to far field. Here, we make very near field measurements of the plasma properties in the ion beam within 0.1 thruster radii of the grid using various probes. Emissive and triple Langmuir probes are swept through the plume to spatially resolve plasma potential, electron temperature and ion density very near to the grid. The goal is to provide refined inputs to the lifetime modeling efforts and increase the accuracy of the models.

Arthur, Neil↗

Propulsion Instruments for Small Hall Thruster Integration

Planning and development are underway for the propulsion instrumentation necessary for the next AFRL electric propulsion flight project, which includes both a small Hall thruster and a micro-PPT. These instruments characterize the environment induced by the thruster and the associated data constitute part of a 'user's manual' for these thrusters. Several instruments probe the back-flow region of the thruster plume, and the data are intended for comparison with detailed numerical models in this region. Specifically, an ion probe is under development to determine the energy and species distributions, and a Langmuir probe will be employed to characterize the electron density and temperature. Other instruments directly measure the effects of thruster operation on spacecraft thermal control surfaces, optical surfaces, and solar arrays. Specifically, radiometric, photometric, and solar-cell-based sensors are under development. Prototype test data for most sensors should be available, together with details of the instrumentation subsystem and spacecraft interface.

ion probes↗

Current to a moving cylindrical electrostatic probe

The current collection characteristics of a moving cylindrical Langmuir probe are evaluated for a range of probe speeds and potentials which are applicable to earth and planetary measurements. The current expressions derived include the cases of the general accelerated current, sheath area limited current, orbital motion limited current, and retarded current. For the orbital motion limited current, a simple algebraic expression is obtained which includes and generalizes the Mott-Smith and Langmuir expressions for both a stationary probe and a rapidly moving probe. For a rapidly moving probe a single formula adequately represents both the accelerated and the retarded current.

Hoegy, W. R.↗

Current to a moving cylindrical electrostatic probe

The current collection characteristics of a moving cylindrical Langmuir probe are evaluated for a range of probe speeds and potentials which are applicable to earth and planetary measurements. The current expressions derived include the cases of the general accelerated current, sheath area limited current, orbital motion limited current, and retarded current. For the orbital motion limited current, a simple algebric expression is obtained which includes and generalizes the Mott-Smith and Langmuir expressions for both a stationary probe and a rapidly moving probe. For a rapidly moving probe, a single formula adequately represents both the accelerated and the retarded current.

Hoegy, W. R.↗

Plasma Sheath Behavior of the ProSEDS Delta II

The Propulsive Small Expendable Deployer System (ProSEDS) mission is a demonstration of the orbit lowering capabilities of an electrodynamic tether. The system is sequenced through various electrical modes, involving both open circuit and closed circuit configurations, so that the performance capabilities of the system can be studied. Ionospheric electrons are collected on the upper end of the bare tether, conducted through the tether, and returned to the ionosphere at the lower end (Delta I1 2nd stage) via the operation of a Hollow Cathode Plasma Contactor (HCPC). The working gas of the HCPC is xenon. Environmental plasma measurements and sheath potential are obtained from the Differential Ion Flux Probe w/Mass Analysis (DIFPM) and Langmuir Probe and Spacecraft Potential (LPSP) instruments. Each instrument has three sensors symmetrically placed about the strut section of the Delta 2nd stage. A magnetometer is also included in the ProSEDS instrumentation suite. An initial analysis of the rocket stage sheath behavior as a function of ProSEDS configuration (open or closed circuit), ambient ionospheric density, orientation to velocity vector (ram-wake influence), and magnetic field orientation is presented. An initial assessment on how well the plasma contactor grounded the rocket stage is also presented.

Wright, K. H.↗

Laboratory experiments on current flow between stationary and moving electrodes in magnetoplasmas

Laboratory experiments were performed in order to investigate the basic physics of current flow between tethered electrodes in magnetoplasmas. The major findings are summarized. The experiments are performed in an effectively very large laboratory plasma in which not only the nonlinear current collection is addressed but also the propagation and spread of currents, the formation of current wings by moving electrodes, the current closure, and radiation from transmission lines. The laboratory plasma consists of a pulsed dc discharge whose Maxwellian afterglow provides a quiescent, current-free uniform background plasma. Electrodes consisting of collectors and electron emitters are inserted into the plasma and a pulsed voltage is applied between two floating electrodes via insulated transmission lines. Besides the applied current in the wire, the total current density in the plasma is obtained from space and time resolved magnetic probe measurements via Maxwell's law. Langmuir probes yield the plasma parameters.

Stenzel, Reiner L.↗

The Vector Electric Field Investigation on the C/NOFS Satellite

We provide an overview of the Vector Electric Field Investigation (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA/GSFC instrument funded by the Air Force Research Laboratory whose main objectives are to: 1) investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) determine the quasi-DC electric fields associated with abrupt, large amplitude, density depletions, and 3) quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions typically referred to as equatorial spread-F. The VEFI instrument includes a vector electric field double probe detector, a fixed-bias Langmuir probe operating in the ion saturation regime, a flux-gate magnetometer, an optical lightning detector, and associated electronics. The heart of the instrument is the set of detectors designed to measure DC and AC electric fields using 6 identical booms that provide 3 axis, 20-m tip-to-tip orthogonal double probes. Each probe extends a 10 cm diameter sphere containing an embedded preamplifier. VEFI also includes a burst memory that enables snapshots of data from 1-8 channels of selected instruments to be sampled at rates of up to 32 kHz each. The bursts may be triggered by the detection of density depletions, intense electric field wave activity in a given band, lightning detector pulses, or an event at a pre-determined time or location. All VEFI instrument components are working exceptionally well. A description of the instrument, its sensors, and their sampling frequencies and sensitivities will be presented. Representative measurements will be shown.

Pfaff, R.↗