At least 199 records · Page 11

Measurement of neutral gadolinium oscillator strengths using dual-comb absorption spectroscopy in laser-produced plasmas

The oscillator strengths of 43 transitions of neutral gadolinium from 530 to 535 nm were determined based on high-resolution absorption spectra measured by probing a laser-produced plasma (LPP) using time-resolved dual-comb spectroscopy (DCS). Absorption spectra were measured at various time delays, ranging from 33 to 252 µs after the onset of the plasma formation, over which the temperature and number density varied as the ablation plume evolved. A Boltzmann analysis was used to determine the excitation temperature and column density of Gd in the ablation plume, based on measured absorption from 20 Gd I spectral lines with known oscillator strengths. Oscillator strengths were then determined for additional dipole-allowed Gd I transitions identified in the absorption spectra, 19 of which were previously unreported. Oscillator strengths of all measured transitions were compared with literature values when available and show good agreement in most cases. Time-resolved measurement of atomic absorption in the cooling plasma provides access to a range of excitation temperatures and optical densities for the atoms in the ablation plume, allowing repeated measurements under different conditions, thereby improving confidence in the results. The high spectral bandwidth and resolution capabilities of DCS make it well-suited to measuring the dense optical spectrum of Gd, and the technique is applicable to other elements, especially lanthanides and actinides.

(280.4788) Optical Sensing, (280.5395) Plasma Diag↗

The H + OCS hot atom reaction - CO state distributions and translational energy from time-resolved infrared absorption spectroscopy

Time-resolved infrared diode laser spectroscopy has been used to probe CO internal and translational excitation from the reaction of hot H atoms with OCS. Product distributions should be strongly biased toward the maximum 1.4 eV collision energy obtained from 278 nm pulsed photolysis of HI. Rotations and vibrations are both colder than predicted by statistical density of states theory, as evidenced by large positive surprisal parameters. The bias against rotation is stronger than that against vibration, with measurable population as high as v = 4. The average CO internal excitation is 1920/cm, accounting for only 13 percent of the available energy. Of the energy balance, time-resolved sub-Doppler line shape measurements show that more than 38 percent appears as relative translation of the separating CO and SH fragments. Studies of the relaxation kinetics indicate that some rotational energy transfer occurs on the time scale of our measurements, but the distributions do not relax sufficiently to alter our conclusions. Vibrational distributions are nascent, though vibrational relaxation of excited CO is unusually fast in the OCS bath, with rates approaching 3 percent of gas kinetic for v = 1.

Nickolaisen, Scott L.↗

Near-MHz temperature and H 2 O measurements in post-detonation fireballs of 25 g hemispherical explosives using scanned-wavelength-modulation spectroscopy

A laser absorption spectroscopy diagnostic integrated within a hardened optical probe was used to measure temperature and water mole fraction at 500 kHz in post-detonation fireballs of explosives. In the experiments, an exploding-bridgewire detonator initiated a 25 g hemisphere of explosive (N5 or PETN). This produced a hemispherical fireball that traveled radially towards a hardened measurement probe. The probe contained a pressure transducer and optical equipment to pitch fiber-coupled laser light across a 12.6 cm gap onto a detector. Tunable diode lasers emitting near 7185.6 and 6806 c m − <#comment/> 1 were used to measure the absorbance spectrum of H 2 O utilizing peak-picking scanned-wavelength-modulation spectroscopy with a scan frequency of 500 kHz and modulation frequencies of 35 and 45.5 MHz, respectively. This enabled measurements of temperature and X H 2 O in the shock-heated air and trailing fireball at 500 kHz. Time histories of pressure, temperature, and H 2 O mole fraction were acquired at different standoff distances to quantify how the fireball evolved in space and time as well as to compare measured quantities between PETN and N5 fireballs. The standard deviation of temperature and X H 2 O during one representative test were found to be 17 K (1.3%) and 0.011 (5%), respectively. These measurements demonstrate this diagnostic’s ability to provide rapid and reliable measurements in harsh, highly transient post-detonation environments produced by solid explosives.

Schwartz, Charles J.↗

Neptunium transition probabilities estimated through laser induced breakdown spectroscopy (LIBS) measurements

in tis report calibration free–laser induced breakdown spectroscopy (CF-LIBS) approaches are promising for the analysis of radioactive materials; however, a lack of reported fundamental properties for these materials is an obstacle to implementation. Spectra of laser induced plasmas containing Np and Sr, along with Saha–Boltzmann methods, were used to estimate the first reported transition probabilities (TPs) of Np. These TPs enabled the first attempt at CF-LIBS analysis of radioactive samples to predict Np/Sr ratios with a mean error of 3.86%. The presented methodology of TP estimation will be applied to the study of other actinides and allow broader applications of CF-15 LIBS in the nuclear field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultrafast spectroscopic studies of vibrational energy transfer in energetic materials

Shock-induced detonation is a key property of energetic materials (EM) that remains empirically understood. One proposed mechanism of shock-initiation in EM is “phonon up-pumping” to initiate chemical reactions, where excitation of lattice phonon modes rapidly transfers energy into intramolecular vibrations, ultimately resulting in the breaking of chemical bonds. We are developing novel ultrafast laser spectroscopy techniques to study vibrational energy transfer from phonon modes to intramolecular vibrations (phonon up-pumping), as well as competing energy transfer pathways from intramolecular vibrations to phonon modes (vibrational cooling). Through combinations of plasma- generated supercontinuum infrared, tunable near- and mid-infrared, and terahertz pulses in pump-probe spectroscopy, supplemented with ab inito simulations, we can explore the energy transfer processes on a sub-picosecond time scale to elucidate vibrational energy transfer pathways and lifetimes in EM. In this work, we highlight recent progress, including the spectral and temporal characteristics of the infrared and THz sources as well as preliminary results on select EM.

36 MATERIALS SCIENCE↗

Laser techniques for spectroscopy of core-excited atomic levels

We discuss three techniques which allow the use of tunable lasers for high resolution and picosecond time scale spectroscopy of core-excited atomic levels. These are: anti-Stokes absorption spectroscopy, laser induced emission from metastable levels, and laser designation of selected core-excited levels.

Harris, S. E.↗

High-resolution spectroscopy of uranium laser-produced plasma using saturated absorption spectroscopy

High-resolution spectroscopy of laser ablation plumes or laser-produced plasmas (LPPs) is valuable for various applications, including measuring crowded spectral features, determining spectroscopic constants, characterizing plasmas, and performing isotopic analysis. However, various line broadening mechanisms in plasmas limit its use for several applications. Here, in this study, we present the use of saturated absorption spectroscopy (SAS) for Doppler-free linewidth analysis in a uranium LPP. We demonstrate that SAS is effective in obtaining Doppler-free Lamb dip profiles with linewidths on the order of ≤ 20 MHz. The effects of saturation on the Doppler-broadened absorption and Lamb dip profiles at different pressures and probe intensities are quantified, and their impact on measurements of plasma properties is discussed. Finally, we show that the linewidths of the Lamb dips can be used for quantitative estimates of pressure and natural broadening in the plasma.

Absorption spectroscopy↗

Laser-Induced-Emission Spectroscopy In Hg/Ar Discharge

Laser-induced-emission (LIE) spectroscopy used to probe low-pressure mercury/argon discharge to determine influence of mercury atoms in metastable 6(Sup3)P(Sub2) state on emission of light from discharge. LIE used to study all excitation processes affected by metastable population, including possible effects on excitation of atoms, ions, and buffer gas. Technique applied to emissions of other plasmas. Provides data used to make more-accurate models of such emissions, exploited by lighting and laser industries and by laboratories studying discharges. Also useful in making quantitative measurements of relative rates and cross sections of direct and two-step collisional processes involving metastable level.

Maleki, Lutfollah↗

Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC). Vista Photonics developed the core technology and built the sensor. Nanoracks designed, constructed the enclosure, interfaces, and battery power management circuitry, integrated all subsystems into the enclosure, and then managed the certification tests, documentation and manifesting. The unit was calibrated in the JSC Toxicology Laboratory. The Multi-Gas Monitor is manifested to fly as a technology demonstration to the ISS in November 2013 and will operate for at least 6 months with data sent to the ground for evaluation. The primary goal is to demonstrate long term interference free operation in the real spacecraft environment.

Pilgrim, Jeffrey S.↗

Kinetics and Mechanism of the Singlet Oxygen Atom Reaction with Dimethyl Ether

Here, we combine in situ laser spectroscopy, quantum chemistry, and kinetic calculations to study the reaction of a singlet oxygen atom with dimethyl ether. Infrared laser absorption spectroscopy and Faraday rotation spectroscopy are used for the detection and quantification of the reaction products OH, H 2 O, HO 2 , and CH 2 O on submillisecond time scales. Fitting temporal profiles of products with simulations using an in-house reaction mechanism allows product branching to be quantified at 30, 60, and 150 Torr. The experimentally determined product branching agrees well with master equation calculations based on electronic structure data and transition state theory. The calculations demonstrate that the dimethyl peroxide (CH 3 OOCH 3 ) generated via O-insertion into the C–O bond undergoes subsequent dissociation to CH 3 O + CH 3 O through energetically favored reactions without an intrinsic barrier. This O-insertion mechanism can be important for understanding the fate of biofuels leaking into the atmosphere and for plasma-based biofuel processing technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of deep learning to single-shot gas-phase laser-induced breakdown spectroscopy

Single-shot fs laser-induced breakdown spectroscopy (LIBS) has the potential to capture ns-scale electrode desorption phenomena in pulsed power fusion drivers. However, the successful implementation of the diagnostic for this purpose is challenging, as it requires interpreting single-shot measurements collected from low-density gas mixtures. In this work, we demonstrate the efficacy of a Bayesian-optimized convolutional neural network (CNN) to interpret these measurements. We generated 256 distinct measurement conditions at relevant gas pressures ranging from 80–530 mTorr by mixing 100–250 sccm H 2 and 50–200 sccm CH 4 in increments of 10 sccm. Despite the considerable overlap between signals separated by 20 sccm, the CNN is able to predict the H 2 flow rate with a root-mean-square error (RMSE) of 15.9 sccm and the CH 4 flow rate with an RMSE of 12.0 sccm. The average relative prediction error is <9% for each gas and largely remains below or near 10%.

Brown, Nathan Parnell [Sandia National Lab. (SNL-N↗

Formation of the C 4 H n + ( n = 2–5) ions upon ionization of acetylene clusters in helium droplets

Infrared (IR) spectroscopy using ultracold helium nanodroplet matrices has proven to be a powerful method to interrogate encapsulated ions, molecules, and clusters. Due to the helium droplets’ high ionization potential, optical transparency, and ability to pick up dopant molecules, the droplets offer a unique modality to probe transient chemical species produced via photo- or electron impact ionization. Here, in this work, helium droplets were doped with acetylene molecules and ionized via electron impact. Ion-molecule reactions within the droplet volume yield larger carbo-cations that were studied via IR laser spectroscopy. This work is focused on cations containing four carbon atoms. The spectra of C 4 H 2 + , C 4 H 3 + , and C 4 H 5 + are dominated by diacetylene, vinylacetylene, and methylcyclopropene cations, respectively, which are the lowest energy isomers. On the other hand, the spectrum of C 4 H 4 + ions hints at the presence of several co-existing isomers, the identity of which remains to be elucidated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectra of ammonia

Developments in the spectral analysis of ammonia are highlighted. Experimental techniques of diode laser spectroscopy were reviewed. It is shown that diode lasers give much better spectral resolution than even Fourier transform spectroscopy.

Rao, K. N.↗

Determination of fluorine distribution in shark teeth by laser-induced breakdown spectroscopy

Quantifying the chemical composition of fast-growing hard tissues in the environment can shed valuable information in terms of understanding ecosystems both prehistoric and current. Changes in chemical composition can be correlated with environmental conditions and can provide information about the organism's life. Sharks can lose 0.1 to 1.1 teeth/day, depending on species, which offers a unique opportunity to record environmental changes over a short duration of time. Shark teeth contain a biomineral phase that is made up of fluorapatite [Ca 5 (PO 4 ) 3 F], and the F distribution within the tooth can be correlated to tooth hardness. Typically, this is determined by bulk acid digestion, energy-dispersive X-ray spectroscopy (EDS), or wavelength-dispersive spectroscopy. Here we present laser-induced breakdown spectroscopy (LIBS) as an alternative and faster approach for determining F distribution within shark teeth. Using a two-volume laser ablation chamber (TwoVol3) with innovative embedded collection optics for LIBS, shark teeth were investigated from sand tiger (Carcharias Taurus), tiger (Galeocerdo Cuvier), and hammerhead sharks (Sphyrnidae). Fluorine distribution was mapped using the CaF 603 nm band (CaF, Β 2 Σ + → X 2 Σ + ) and quantified using apatite reference materials. In addition, F measurements were cross referenced with EDS analyses to validate the findings. Distributions of F (603 nm), Na (589 nm), and H (656 nm) within the tooth correlate well with the expected biomineral composition and expected tooth hardness. This rapid methodology could transform the current means of determining F distribution, particularly when large sample specimens (350 mm 2 , presented here) and large quantities of specimens are of interest.

36 MATERIALS SCIENCE↗