Search NASA⌕ Search

SEARCH · Search NASA

Results for “LINEAR ACCELERATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

An Agile/XP software development process for modernizing the accelerator control system at Fermilab

Fermilab is undergoing the most ambitious upgrade to its accelerator control system of the 21st century. As part of the ACORN project, hundreds of legacy control system applications written in C/C++ will be re-imagined and developed from the ground up. In addition, applications to support Fermilab’s new super-conducting linear accelerator are already under construction. To manage the development of modern controls applications, the Controls department has adopted an Agile software development process based on eXtreme Programming. In this paper we will describe our process and detail our experience applying it to the development of two case studies.

Diamond, John [Fermilab]↗

Compact cryomodule for mobile stand-alone superconducting industrial accelerators

Superconducting RF (SRF) accelerators have the potential to be more profitable in comparison with normally conducting accelerators, as long they can be made compact, achieve operational simplicity, autonomy, trans- portability, satisfactory energy efficiency, as well as have reasonable costs. The development of SRF technologies such as Nb 3 Sn coating, conductively-cooled resonators, and high-capacity liquid-helium-free cryocoolers made SRF accelerators mobile and energetically and economically efficient at a beam power of tens of kW. One of the key elements of such an accelerator is the cryomodule, which must have minimal thermal losses to enable operation from low power cryoheads and enable conductive cooling of SRF resonator. In this research we present the design and test results of a compact cryomodule for an industrial stand-alone SRF linear accelerator proto- type, based on 650 MHz elliptical resonators, being developed at Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗

Multiparticle-hole excitations in nuclei near N = Z = 20: $^{41}$K

This experimental study of high-spin structure near the N = Z = 20 region focuses on 41 K and also reports three newly observed γ transitions in 41 Ca from the same reaction. High-spin states were populated using the 26 Mg( 18 O, p2nγ) 41 K and 26 Mg( 18 O, 3nγ) 41 Ca reactions at a beam energy of 50 MeV at the Florida State University John D. Fox Superconducting Linear Accelerator Laboratory, employing the FSU high-purity germanium detector array. The level scheme of 41 K was extended to 12325 keV, possibly up to J π = 25/2 − or 27/2 + , by means of 25 new γ-ray transitions, and that of 41 Ca to 9916 keV. Linear polarization and angular-distribution measurements were used to provide spin and parity information for several states in the 41 K decay scheme. The results are compared with spsdpf cross-shell shell-model calculations using the FSU interaction. Configurations involving zero or one nucleon promoted from the sd to the fp shell reproduce the energies of many known states reasonably well, while multi-particle excitations reveal a more complex interplay of single-particle motion, collective pairing, and deformation, posing an interesting challenge for future theoretical work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Analysis of a Double Wall, Water Cooled Window for Accelerator Based Mo-99 Production

The electron accelerator based Mo-99 production technique requires the use of Rhodotrons to generate 38 MeV, 6.32 mA pulsed electron beams. The introduction of the pulsed beam structure has introduced fatigue concerns in the vacuum-helium windows that did not exist previously for electron beam production via linear accelerators. Previous analysis has shown that temperature fluctuations of approximately 100°C above and below the steady state operating temperature of ~500°C will occur within the windows. A water cooled window will eliminate this concern by reducing the primary mechanical stress due to the 300-psig helium pressure load as well as the secondary thermally induced stress. Although a water cooled window was considered years ago, the complexities of adding an additional water line was unattractive until now. A double wall, water cooled window has been designed and analyzed for this reason. The water cooled window design is shown to decrease the helium-side window temperature to as low as 125°C, while the vacuum-side window is maintained at 161°C at a water flow rate of 3.2 GPM. These low steady state temperatures reduce the thermal stress of the helium-side window significantly. Also, the primary mechanical stress has been reduced by roughly 50% due to the reduced pressure gradient across the helium-side window (150-psig water and 300-psig helium). Considering a Mo-99 production loss of roughly 1%, the water cooled window is a drastic improvement over the previous helium cooled designs and should be greatly considered for future upgrades and redesign.

43 PARTICLE ACCELERATORS↗

MCNP Neutronic Design Optimization of an Accelerator-Driven Subcritical Assembly for Mo-99 Production

Molybdenum-99 (99Mo) has been in short supply in the recent decades. The most common productionmechanism, irradiation in a reactor fueled by highly enriched uranium (HEU), raisesproliferation concerns. Novel efforts are being pursued to meet the demand for 99Mo withoutHEU irradiation, relying on the processing of low-enriched uranium or natural uranium. Onesuch concept is to use an electron linear accelerator to generate bremsstrahlung that, through aphotonuclear reaction, can help multiply neutrons in a subcritical assembly. The goal of this workwas to neutronically optimize the subcritical assembly for keff and 99Mo production. This optimizationis unique for The design was optimized in terms of reflector type, pitch, and LEU andNU mass. Results of the paper show the effects of fuel mass, pitch, and reflector material on keffand the NU fission fraction. keff was found to be mostly driven by LEU mass, and the NU fissionfraction was dependent on several parameters, primarily pitch and mass.

Conant, Andrew↗

High-Efficiency Inductive Output Tubes Using a Third Harmonic Drive on the Grid

In this article, we discuss the use of a third harmonic component to the drive voltage on the grid of an inductive output tube (IOT). High-efficiency IOTs are typically characterized by efficiencies up to 70%–75%. However, the achievement of efficiencies greater than 80% would substantially reduce the operating costs of next-generation accelerators. In order to achieve this goal, we consider the addition of a third harmonic component to the drive signal on the grid of an IOT. The use of a third harmonic drive component in IOT guns has been considered in order to apply such a gun as the injector of radio frequency linear accelerators (RF linacs). Furthermore, we consider that the IOT will be used to provide the rf power to drive RF linacs and apply the third harmonic with the intention of increasing the efficiency of the RF output of the IOT. We consider a model IOT with a 700-MHz resonant cavity and using an annular beam with a voltage of 30 kV, an average current of 6.67 A yielding a perveance of about 1.3 μP. We simulate this IOT using the NEMESIS simulation code which has been successfully validated by comparison with the K5H90W-2 IOT developed by Communications and Power Industries. It is found that the effect of the third harmonic on the efficiency is greatest when the phase of the third harmonic is shifted by radians with respect to the fundamental drive signal and with third harmonic powers greater than about 50% that of the fundamental drive power. For the present example, we show that efficiencies approaching 86% are possible by this means.

43 PARTICLE ACCELERATORS↗

Assessment of 180,182, 183,184,186 W Photonuclear Data

When electron beams from accelerators are stopped in thick targets made of materials with a high atomic number (or high-Z targets), they produce photons through braking radiation (commonly known as bremsstrahlung). The efficiency of photon production increases with the atomic number (Z). Tungsten is commonly chosen as a bremsstrahlung converter in both research and medical linear accelerators due to its high Z, large bremsstrahlung cross section, high melting point, and excellent thermal conductivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton and electron RLA optics design

We describe optics designs of the key components of proton and electron Recirculating Linear Accelerators (RLAs). They are presented in the context of a high-power hadron accelerator being considered at ORNL and a CEBAF electron energy doubling study, FFA@CEBAF, being developed at Jefferson Lab. Both concepts rely on the Fixed-Field Alternating gradient (FFA) arc optics designs where multiple beam passes are transported by a single beam line. Some of the main challenges of the optics design are in synchronization and orbital and linear optics match of the individual passes with the linac straight. To minimize the complexity of the matching sections and make them more practical, it is preferable to complete as much of the orbital and optical match as possible within a single beam line using the FFA approach. The adiabatic matching technique proposed earlier is one such solution, but it requires a large number of cells. We present a much shorter matching section design based on another approach. A compact dog-leg-type section of several bending dipoles and quadrupoles is used to suppress the orbital offset and dispersion coming out of a periodic cell. Additional quadrupoles are used in the section to keep the beta functions under control and simplify their subsequent match to the linac. Initial beam tracking results are presented.

Benesch, J.↗

Test Results of a High-Gradient 2.856-GHz Negative Harmonic Accelerating Waveguide

We report the high-gradient tests results of a novel traveling wave accelerating structure for β=0.3 based on a novel approach of operating at the first negative spatial harmonic. Accelerating gradients of 50 MV/m and peak electric fields of 160 MV/m were achieved in a single structure consisting of 15 coupled cells during tests at the advanced photon source. This work was performed by RadiaBeam, in collaboration with the Argonne National Laboratory, as a part of a Research and Development Program for the development of an ultrahigh-gradient linear accelerator, the Advanced Compact Carbon Ion Linac, for hadron therapy.

42 ENGINEERING↗

Plasma electron contribution to beam emittance growth from Coulomb collisions in plasma-based accelerators

Coulomb collisions with background plasma can cause emittance growth in plasma accelerators. This paper extends the theory to consider collisions with not only motionless plasma ions but also plasma electrons with relativistic motion, based on the Frankel cross section. The theory is verified by particle-in-cell simulations with a Monte Carlo collision module. Further, it is shown that the electron contribution has the same amount as that of ions in linear acceleration regime and may not be negligible in nonlinear regime depending on the plasma electron density and its relativistic bulk velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bridging the gap of storage ring light sources and linac-driven free-electron lasers

High-gain free-electron lasers (FELs) are driven by short, high-charge density electron beams as only produced at dedicated single pass or recirculating linear accelerators. We describe new conceptual, technical, and modeling solutions to produce subpicosecond, up to ~100 μJ-energy extreme ultra-violet and soft x-ray FEL pulses at high- and tunable repetition rates, from diffraction-limited storage ring light source. In contrast to previously proposed schemes, we show that lasing can be simultaneous to the standard multibunch radiation emission from short insertion devices, and that it can be obtained with limited impact on the storage ring infrastructure. By virtue of the high-average power but moderate pulse energy, the storage ring-driven high-gain FEL would open the door to unprecedented accuracy in time-resolved spectroscopic analysis of matter in the linear response regime, in addition to inelastic scattering experiments.

43 PARTICLE ACCELERATORS↗

Recent progress in high-temperature superconducting undulators

Considerable effort has been devoted to the development of superconducting undulators (SCUs) intended for particle accelerator-based light sources, including synchrotrons and free electron laser (FEL) facilities. Recently, a high-temperature superconducting (HTS) undulator prototype, consisting of staggered-array Re-Ba-Cu-O bulks, achieved an on-axis sinusoidal magnetic field profile with a peak amplitude B$_0$ of 2.1 T and a period length of 10 mm, resulting in a deflection parameter K = 1.96. Such a short period HTS undulator not only enables the generation of higher-energy photons, but also supports the construction of economically feasible and compact FELs with shorter linear accelerators (LINACs). This article provides a comprehensive review of recent advances in the staggered-array bulk HTS undulator as well as other types of HTS undulators. Furthermore, it offers insights into the development of engineering HTS undulator prototypes designed for deployment in synchrotron and free electron laser (FEL) facilities. We conclude by discussing opportunities for and the challenges facing the use of HTS undulators in practical applications.

43 PARTICLE ACCELERATORS↗

Dynamic Aperture of the PIP-II Accumulator Ring (PAR)

The Proton Improvement Plan-II (PIP-II) will include a superconducting linear accelerator which will accelerate H- ions to 800MeV, at an intensity never seen before. A proposed PIP-II Accumulator Ring (PAR) can reduce the injection losses to the booster, enhance the ramp up of the Long Baseline Neutrino Facility (LBNF) and support experiments in Dark Sector Physics. When the beam is circulating in PAR at its full intensity, it will then be transferred to the Booster via single turn injection. Strong PAR focusing results in larger phase advances, shorter focal lengths and higher machine tunes, which creates robust beam envelope control. Particles will be able to survive modest excursions from the elliptical phase-space trajectories of linear optics, and any loss of particles would be due to reduced dynamic aperture. The values for tunes and chromaticities are flexible and will continue to evolve as the lattice matures. Since there will be non-linear terms impacting the particles’ trajectories, tracking will include realistic magnetic field errors and installation alignment errors to determine the dynamic aperture as a function of the machine tunes. This will allow us to determine the optimum operating point in phase-space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-linear Wire Rope Isolator Model to Enhance Transportation Simulation of Fragile Equipment

Abstract Introduction Wire rope isolators are often used as means of vibration isolation for the transportation of fragile machine equipment. When deployed as suspension systems in a transportation scenario, a simple spring–damper model is often used to predict the dynamic loads that act on the structure being transported. However, this simple model has proved to be too simplistic to be used in the development of an accurate numerical model that can predict the vibration levels experienced by the inner components of fragile equipment during its transportation. This paper describes the experimental tests conducted on a wire rope isolator used for the transportation of the prototype SSR1 cryomodule. Materials and methods A hysteretic Bouc–Wen model has been used to analytically describe the force–deformation relationship of the wire rope isolators. The developed model of the isolator has been implemented in a larger model to simulate the actual transportation of the prototype SSR1 cryomodule, a section of the new PIP-II linear accelerator under construction at Fermilab. A series of multibody dynamic simulations with rigid and flexible components was used to numerically determine the acceleration of some critical components. Results and conclusions An actual experimental transportation was simulated using two numerical models: the developed Bouc–Wen model and a conventional spring–damper model. It is shown how the Bouc–Wen formulation of the isolator characteristics drastically improves the correspondence between experimental and simulated results if compared to a spring–damper model, especially in the range of 0–30 Hz which is the most critical for transportation problems.

42 ENGINEERING↗

Novel design and diagnostics improvements for increased production capacity and improved reliability at the Los Alamos Isotope Production Facility

The Isotope Production Facility (IPF) at Los Alamos National Laboratory (LANL) is used to produce an array of isotopes for medical, global security, and research applications with an intense beam of protons supplied by the linear accelerator at the Los Alamos Neutron Science Center (LANSCE). An Accelerator Improvement Project (AIP) was recently conducted at IPF to improve facility reliability and reduce programmatic risk while increasing general isotope production capacity and flexibility. This was accomplished through the installation of an improved beam window assembly, more robust beam diagnostics, an active and adjustable collimator, and a new beam rastering system. This paper will highlight the four exciting innovations and how they were designed, validated, and installed in parallel as well as the significant operational advantages they provide to IPF. Key experiments and the increased currents achieved in routine production runs demonstrating the enhanced capability from the AIP will be presented. As a result, the most notable capability enhancements include irradiations with beam currents ranging from 100 nA experimental runs up to 300 μA on routine production targets and utilization of a range of cylindrical target diameters.

100 MeV protons↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗

In-flight production of an isomeric beam of 16 N

In this work, an in-flight beam of 16 N was produced via the single-neutron adding ($\textit{d,p}$) reaction in inverse kinematics at the recently upgraded Argonne Tandem Linear Accelerator System (ATLAS) in-flight system. The amount of the 16 N beam which resided in its excited 0.120 MeV $J^\pi$ = 0 – isomeric state (T 1/2 ≈ 5 μs) was determined to be 40(5)% at a reaction energy of 7.9(3) MeV/$\textit{u}$, and 24(2)% at a reaction energy of 13.2(2) MeV/$\textit{u}$. The isomer measurements took place at an experimental station ≈ 30 m downstream of the production target and utilized an Al beam-stopping foil and a HPGe Clover detector. Composite 16 N beam rate determinations were made at the experimental station and the focal plane of the Argonne in-flight radioactive ion-beam separator (RAISOR) with Si ΔE-E telescopes. A Distorted Wave Born Approximation (DWBA) approach was coupled with the known spectroscopic information on 16 N in order to estimate the relative 16 N isomer yields and composite 16 N beam rates. In addition to the observed reaction-energy dependence of the isomer fraction, a large sensitivity to the angular acceptance of the recoils was also observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗