Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIQUID LEVEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Experimental Evaluation of White Light Fabry-Perot Interferometry Fiber-Optic Strain Gages when Measuring Small Strains

An experimental study was conducted to evaluate whether fiber optic strain gages (FOSG) are "better" sensors than typical foil gages. A particularly attractive feature of FOSG was their specified resolution of 0.01% of full-scale (0.1 micro strain for 1000 micro strain full-scale). This feature would make FOSG practical tank level sensors, by measuring very small strains on the support structure of a tank. A specific application in mind was to measure liquid oxygen tank level, with support beams that were predicted to contract approximately 11 micro strain as the tank goes from empty to full. Among various fiber optic technologies currently available, Fabry-Perot Interferometry using white light was selected. This technology exhibits highly desirable feature such as absolute strain measurement, linearity over its full-scale, and temperature compensation. However, experiment results suggest that the resolution is 0.8 micro strain, at best, calibration from one sensor to another can be off by 2.4 - 11.2%, and that temperature compensation is not fully predictable, with errors of up to 3.5 micro strain over an 11C range. Hence, when compared with classic foil gages, FOSG possess less accuracy, similar resolution and repeatability (precision), and superior linearity over their entire operating range. They are immune to EMI and their signals suffer minimal degradation over long distances. It is also expected that drift with time will be minimal in FOSG whereas the gage factor of foil sensors changes over time when exposed to varying environmental conditions. In conclusion, FOSG are "better" than foil gages as long as the application allows calibration of individual units as installed for operation.

St.Cyr, William↗

A surface-based cloud observing system

The paper describes a surface-based system, called the Cloud Observing System (COS), that was developed for measurements of the dynamical and thermodynamical properties of clouds and of their interaction with the large-scale environment, by combining several remote sensors and in situ systems. The atmospheric parameters that will be measured by COS include precipitation, the velocity and direction of wind, the cloud liquid water, the low-level winds and turbulence structure, integrated liquid and vapor quantities, the temperature and water profiles, the cloud radiance and the cloud base temperature, irradiances at the surface, the low-level temperature profile, the cloud-base height, and the cloud fraction; video cameras will provide visual records of clouds.

Albrecht, B. A.↗

Measured and predicted effects of gravity level on directional dendritic solidification of NH4Cl-H2O

Dendritic growth front rates during vertical directional solidification are predicted for gravity levels of 10 exp 0 g sub e (where e is earth gravity), 10 exp -1 g sub e, 10 exp -2 g sub e, 10 exp -3 g sub e, 10 exp -4 g sub e, and 10 exp -5 g sub e (microgravity) for the physical conditions used for a recent ammonium chloride-water solidification experiment on the International Microgravity Laboratory I (IMLI). The growth front rates at 10 exp 0 g sub e and 10 exp -5 g sub e are validated using ground based laboratory and IMLI experimental data. As the gravity decreases, the growth rates increase until they approach a maximum at approximately 10 exp -4 g sub e. The 10 exp -4 and 10 exp -5 levels are equivalent. Liquid concentration and volume fraction, temperature profiles and fluid flow velocities are also calculated. Kinetic energy calculations for each of the six gravity levels indicate that the threshold for fluid flow to affect the growth front rate is in the range of 10 exp -8 ergs.

Mccay, T. D.↗

Thermocryogenic buckling and stress analyses of a partially filled cryogenic tank subjected to cylindrical strip heating

Thermocryogenic buckling and stress analyses were conducted on a horizontally oriented cryogenic tank using the finite element method. The tank is a finite-length circular cylindrical shell with its two ends capped with hemispherical shells. The tank is subjected to cylindrical strip heating in the region above the liquid-cryogen fill level and to cryogenic cooling below the fill level (i.e., under thermocryogenic loading). The effects of cryogen fill level on the buckling temperature and thermocryogenic stress field were investigated in detail. Both the buckling temperature and stress magnitudes were relatively insensitive to the cryogen fill level. The buckling temperature, however, was quite sensitive to the radius-to-thickness ratio. A mechanical stress analysis of the tank also was conducted when the tank was under: (1) cryogen liquid pressure loading; (2) internal pressure loading; and (3) tank-wall inertia loading. Deformed shapes of the cryogenic tanks under different loading conditions were shown, and high-stress domains were mapped on the tank wall for the strain-gage installations. The accuracies of solutions from different finite element models were compared.

Ko, William L.↗

Results of Liquid Motion Experiment Analyzed

About half of all scientific and commercial spacecraft spin during some part of their mission. Although spinning has many benefits (increasing stability, controlling the location of liquid propellants, and distributing solar heat loads), it also creates problems because a precession (or wobble) motion is unavoidable. For modern spacecraft, by far the largest source of wobble is energy dissipation in the liquid of partially filled tanks. The liquid s energy dissipation cannot, however, be quantified adequately by any ground test. Current analytical models are also inadequate because fundamental data on fluid motion in low gravity are needed to validate them. Consequently, spacecraft attitude-control systems are designed and operated very conservatively. Nonetheless, spacecraft often still perform poorly in orbit, and some have been lost because of a rapid increase of the wobble rate. The Liquid Motion Experiment (LME) was designed to provide spacecraft designers accurate data on the wobble dynamics of spacecraft that contain large quantities of mobile liquids. LME, which was flown on the space shuttle mission STS-84, was built under contract to the NASA Lewis Research Center by the Southwest Research Institute of San Antonio, Texas. Major accomplishments for 1998 include reduction of the flight data and publication of the experimental results. LME was essentially a spin table that created a realistic nutation motion of scale-model tanks containing liquid. Two spherical and two cylindrical transparent tanks were tested simultaneously, and three sets of such tanks were employed to vary liquid viscosity, fill level, and propellant management device (PMD) design. All the tanks were approximately 4.5 in. in diameter. The primary test measurements were the radial and tangential torques exerted on the tanks by the liquid. These torques could not be measured on the ground because of the masking effects of gravity.

Chato, David J.↗

Variable-gravity anti-vortex and vapor-ingestion-suppression device

A liquid propellant management device for placement in a liquid storage tank adjacent an outlet of the storage tank to substantially reduce or eliminate the formation of a dip and vortex in the liquid of the tank, as well as prevent vapor ingestion into the outlet, as the liquid drains out through the outlet. The liquid propellant management device has a first member adapted to suppress the formation of a vortex of a liquid exiting the storage tank. A plate is affixed generally perpendicular to the first member, wherein the plate is adapted to suppress vapor ingestion into the outlet by reducing a dip in a surface level of the liquid leaving the tank. A second member is affixed to the second side of the plate. The second member ensures that the plate is wet with liquid and assists in positioning bubbles away from the outlet.

Grayson, Gary D.↗

Scale Model Thruster Acoustic Measurement Results

Subscale rocket acoustic data is used to predict acoustic environments for full scale rockets. Over the last several years acoustic data has been collected during horizontal tests of solid rocket motors. Space Launch System (SLS) Scale Model Acoustic Test (SMAT) was designed to evaluate the acoustics of the SLS vehicle including the liquid engines and solid rocket boosters. SMAT is comprised of liquid thrusters scalable to the Space Shuttle Main engines (SSME) and Rocket Assisted Take Off (RATO) motors scalable to the 5-segment Reusable Solid Rocket Motor (RSTMV). Horizontal testing of the liquid thrusters provided an opportunity to collect acoustic data from liquid thrusters to characterize the acoustic environments. Acoustic data was collected during the horizontal firings of a single thruster and a 4-thruster (Quad) configuration. Presentation scope. Discuss the results of the single and 4-thruster acoustic measurements. Compare the measured acoustic levels of the liquid thrusters to the Solid Rocket Test Motor V - Nozzle 2 (SRTMV-N2).

Kenny, R. Jeremy↗

Current Ground Test Options for Nuclear Thermal Propulsion (NTP)

About 20 different NTP engines/ reactors were tested from 1959 to 1972 as part of the Rover and Nuclear Engine for Rocket Vehicle Application (NERVA) program. Most were tested in open air at test cell A or test cell C, at the Nevada Test Site (NTS). Even after serious engine breakdowns of the reactor (e.g., Phoebus 1A), the test cells were cleaned up for other engine tests. The engine test stand (ETS) was made for high altitude (approximately 1 psia) testing of an NTP engine with a flight configuration, but still had the exhaust released to open air. The Rover/NERVA program became aware of new environmental regulations which would prohibit the release of any significant quantity of radioactive particulates and noble gases into the open air. The nuclear furnace (NF-1) was the last reactor tested before the program was cancelled in 1973, but successfully demonstrated a scrubber concept on how to filter the NTP exhaust. The NF-1 was demonstrated in the summer of 1972. The NF-1 used a 44MW reactor and operated each run for approximately 90 minutes. The system cooled the hot hydrogen exhaust from the engine with a water spray before entering a particle filter. The exhaust then passed through a series of heat exchangers and water separators to help remove water from the exhaust and further reduce the exhaust temperatures. The exhaust was next prepared for the charcoal trap by passing through a dryer and effluent cooler to bring exhaust temperatures close to liquid nitrogen. At those low temperatures, most of the noble gases (e.g., Xe and Kr made from fission products) get captured in the charcoal trap. The filtered hydrogen is finally passed through a flare stack and released to the air. The concept was overall successful but did show a La plating on some surfaces and had multiple recommendations for improvement. The most recent detailed study on the NTP scrubber concept was performed by the ARES Corporation in 2006. The concept is based on a 50,000 lbf thrust engine (approximately 1 GW) with a maximum burn time of 1 hour. The concept utilized lessons learned from NF-1. The strategy breaks down the exhaust into parallel paths to allow flexibility with engine size and mass flow of exhaust. Similar to NF-1, the exhaust is slowed down, cooled, filtered of particulates, filtered of noble gases, and then the clean hydrogen is flared to open air. Another concept proposed by Steve Howe (currently Director of the Center for Space Nuclear Research) to simplify the NTP exhaust filtering is to run the hydrogen exhaust into boreholes underground to filter the exhaust. The two borehole site locations proposed are at the NTS and at the Idaho National Laboratory (INL). At NTS, the boreholes are 8' diameter and 1200' deep. The permeability of hydrogen through the soil and its buoyancy will allow it to rise up through the soil and allow the filtering of noble gases and radioactive particulates. The exhaust needs to be cooled to 600C before entering the borehole to avoid soil glazing. Preliminary analysis shows a small buildup of back pressure with time which depends on permeability. Noble gases entering the borehole walls deep can take a long time before reaching the surface. Other factors affecting permeability include borehole pressure, water saturation, and turbulence. Also, a possible need to pump out contaminated water collected at the bottom of the borehole. At INL, the borehole concept is slightly different. The underground borehole has openings to the soil at special depths which have impermeable interbeds above the water table and below the surface to allow the exhaust to travel horizontal between the impermeable layers. Preliminary results indicate better permeability than at NTS. The last option is total containment of the exhaust during the test run. The concept involves slowing down the flow to subsonic in a water cooled diffuser. The hydrogen is burned off in an oxygen rich afterburner with the only products being steam, oxygen, and some noble gases. A heat exchanger and water spray pulls heat from the steam and lowers the temperature for condensation. The optimum ratio between the two is being investigated, with a goal to minimize the total volume of the water hold tanks. A water tank farm collects the contaminated water. The amount of water produced from burning the hydrogen is approximately 100,000 gallons (not including cooling water) for a 25k lbf engine operating for 50 minutes. Residual gases (e.g., oxygen and some noble gases) can be captured at cryogenic levels with a liquid nitrogen cooled dewar. After a few weeks post-test, the radiation levels can drop to more favorable levels before slowly draining each capture tank and using existing filters. With today's environmental regulations, the NTP exhaust is filtered to meet 10 mrem/year exposure to the general public (at a DOE site) or 100 mrem/year (via NRC when tested elsewhere), when natural background radiation exposure to the general public is 300- 600 mrem per year. The current society feels more comfortable with filtering even lower to as low as reasonably achievable (ALARA).

Gerrish, Harold P., Jr.↗

Containerless processing of undercooled melts

All practical solidification processes involve some level of melt undercooling. Usually in bulk liquids crystallization is initiated at a heterogeneous nucleation site at low undercooling. The realization of appreciable levels of liquid undercooling requires some control over the kinetics of crystal nucleation. One level of control is available in containerless processing where the capability to melt and solidify samples without a container removes a major source of impurities and heterogeneous nucleation sites which can be effective in promoting large undercooling and in studying other potential nucleants. The microgravity environment offers a unique opportunity for containerless processing of large liquid samples with negligible melt disturbance and continuous temperature measurement throughout processing. Perhaps the most important potential for microgravity containerless processing lies in the significant structural control to develop distinct microstructures and metastable phases during solidification at high undercooling.

Perepezko, J. H.↗

Exhaust emissions from a premixing, prevaporizing flame tube using liquid jet A fuel

Emissions of nitrogen oxides, carbon monoxide, and unburned hydrocarbons were measured in a burner where liquid Jet A fuel was sprayed into the heated air stream and vaporized upstream of a perforated plate flameholder. The burner was tested at inlet air temperatures at 640, 800, and 833 K, an inlet pressure of 5.6 X 100,000 N/m squared, a reference velocity of 25 m/sec, and equivalence ratios from lean blowout to 0.7. Nitrogen oxide levels of below 1.0 g NO2/kg fuel were obtained at combustion efficiencies greater than 99 percent. The measured emission levels for the liquid fuel agreed well with previously reported premixed gaseous propane data and agreed with well stirred reactor predictions. Autoignition of the premixed fuel air mixture was a problem at inlet temperatures above 650 K with 104 msec premixing time.

Marek, C. J.↗

Liquid Acquisition Device Design Sensitivity Study

In-space propulsion often necessitates the use of a capillary liquid acquisition device (LAD) to assure that gas-free liquid propellant is available to support engine restarts in microgravity. If a capillary screen-channel device is chosen, then the designer must determine the appropriate combination screen mesh and channel geometry. A screen mesh selection which results in the smallest LAD width when compared to any other screen candidate (for a constant length) is desirable; however, no best screen exists for all LAD design requirements. Flow rate, percent fill, and acceleration are the most influential drivers for determining screen widths. Increased flow rates and reduced percent fills increase the through-the-screen flow pressure losses, which drive the LAD to increased widths regardless of screen choice. Similarly, increased acceleration levels and corresponding liquid head pressures drive the screen mesh selection toward a higher bubble point (liquid retention capability). After ruling out some screens on the basis of acceleration requirements alone, candidates can be identified by examining screens with small flow-loss-to-bubble point ratios for a given condition (i.e., comparing screens at certain flow rates and fill levels). Within the same flow rate and fill level, the screen constants inertia resistance coefficient, void fraction, screen pore or opening diameter, and bubble point can become the driving forces in identifying the smaller flow-loss-to-bubble point ratios.

VanDyke, M. K.↗

Ignition delay of a gas mixture above a liquid fuel pool

A computational study has been made of transient heat transfer and fluid flow of an axisymmetric two-layer gas-and-liquid system heated from above by a small hot spot (e.g., a hot wire or pilot flame) located close to the liquid surface. The gas phase is unconfined above the liquid pool. The effects of varying gravity level (0.0001 to 1 gn), liquid pool height, and heater height are investigated. Thermocapillary convection induced by the nonuniform heating of the liquid surface combines with buoyancy forces to affect the heat transfer and the transport of fuel vapor toward the heat source. At reduced gravity, gas-phase conduction is comparable to the incident radiation at the liquid surface, whereas at 1 gn, buoyant convection carries the heat upward from the heat source and, therefore, the liquid is heated primarily by radiation.

Schiller, D. N.↗

Structures Self-Assembled Through Directional Solidification

Nanotechnology has created a demand for new fabrication methods with an emphasis on simple, low-cost techniques. Directional solidification of eutectics (DSE) is an unconventional approach in comparison to low-temperature biomimetic approaches. A technical challenge for DSE is producing microstructural architectures on the nanometer scale. In both processes, the driving force is the minimization of Gibb's free energy. Selfassembly by biomimetic approaches depends on weak interaction forces between organic molecules to define the architectural structure. The architectural structure for solidification depends on strong chemical bonding between atoms. Constituents partition into atomic-level arrangements at the liquid-solid interface to form polyphase structures, and this atomic-level arrangement at the liquid-solid interface is controlled by atomic diffusion and total undercooling due to composition (diffusion), kinetics, and curvature of the boundary phases. Judicious selection of the materials system and control of the total undercooling are the keys to producing structures on the nanometer scale. The silicon-titanium silicide (Si-TiSi2) eutectic forms a rod structure under isothermal cooling conditions. At the NASA Glenn Research Center, directional solidification was employed along with a thermal gradient to promote uniform rods oriented with the thermal gradient. The preceding photomicrograph shows the typical transverse microstructure of a solidified Si-TiSi2 eutectic composition. The dark and light gray regions are Si and TiSi2, respectively. Preferred rod orientation along the thermal gradient was poor. The ordered TiSi2 rods have a narrow distribution in diameter of 2 to 3 m, as shown. The rod diameter showed a weak dependence on process conditions. Anisotropic etch behavior between different phases provides the opportunity to fabricate structures with high aspect ratios. The photomicrographs show the resulting microstructure after a wet chemical etch and a dry plasma etch. The wet chemical etches the silicon away, exposing the TiSi2 rods, whereas plasma etching preferentially etches the Si-TiSi2 interface to form a crater. The porous architectures are applicable to fabricating microdevices or creating templates for part fabrication. The porous rod structure can serve as a platform for fabricating microplasma devices for propulsion or microheat exchangers and for fabricating microfilters for miniatured chemical reactors. Although more work is required, self-assembly from DSE can have a role in microdevice fabrication.

Dynys, Frederick W.↗

Radiative Susceptibility of Cloudy Atmospheres to Droplet Number Perturbations: 1. Theoretical Analysis and Examples from MODIS

Theoretical and satellite-based assessments of the sensitivity of broadband shortwave radiative fluxes in cloudy atmospheres to small perturbations in the cloud droplet number concentration (N) of liquid water clouds under constant water conditions are performed. Two approaches to study this sensitivity are adopted: absolute increases in N, for which the radiative response is referred to as absolute cloud susceptibility, and relative increases in N or relative cloud susceptibility. Estimating the former is more challenging as it requires an assumed value for either cloud liquid water content or geometrical thickness; both susceptibilities require an assumed relationship between the droplet volume and effective radius. Expanding upon previous susceptibility studies, present radiative calculations include the effect of AN perturbations on droplet asymmetry parameter and single-scattering albedo, in addition to extinction. Absolute cloud susceptibility has a strong nonlinear dependence on the droplet effective radius as expected, while relative cloud susceptibility is primarily dependent on optical thickness. Molecular absorption and reflecting surfaces both reduce the relative contribution of the cloud to the top-of-atmosphere (TOA) flux and therefore also reduce the TOA albedo susceptibility. Transmittance susceptibilities are negative with absolute values similar to albedo susceptibility, while atmospheric absorptance susceptibilities are about an order of magnitude smaller than albedo susceptibilities and can be either positive or negative. Observation-based susceptibility calculations are derived from MODIS pixel-level retrievals of liquid water cloud optical thickness, effective radius, and cloud top temperature; two data granule examples are shown. Susceptibility quantifies the aerosol indirect effect sensitivity in a way that can be easily computed from model fields. As such, susceptibilities derived from MODIS observations provide a higher-order test of model cloud properties used for indirect effect studies. MODIS-derived global distributions of cloud susceptibility and radiative forcing calculations are presented in a companion paper.

Platnick, Steven↗

Adjustable Lid Aids Silicon-Ribbon Growth

Closely-spaced crucible cover speeds up solidification. Growth rate of dendritic-web silicon ribbon from molten silicon increased by controlling distance between crucible susceptor lid and liquid/solid interface. Lid held in relatively high position when crucible newly filled with chunks of polycrystalline silicon. As silicon melts and forms pool of liquid at lower level, lid gradually lowered.

Mchugh, J. P.↗

High temperature superconducting magnetic energy storage for future NASA missions

Several NASA sponsored studies based on 'conventional' liquid helium temperature level superconductivity technology have concluded that superconducting magnetic energy storage has considerable potential for space applications. The advent of high temperature superconductivity (HTSC) may provide additional benefits over conventional superconductivity technology, making magnetic energy storage even more attractive. The proposed NASA space station is a possible candidate for the application of HTSC energy storage. Alternative energy storage technologies for this and other low Earth orbit missions are compared.

Faymon, Karl A.↗

Statistical retrieval of precipitation cell-top altitude using passive 118-GHz observations

A nonlinear statistical-retrieval operator for precipitation cell-top altitude using high-spatial-resolution passive 118-GHz O2 brightness spectra is demonstrated. The retrieval operator consists of a Karhunen-Loeve transformation followed by a rank reduction, a linearization, and a linear minimum mean-square-error estimator. Information from the 118-GHz data on the ambient atmospheric-temperature profile and the precipitation cell size is also incorporated into the linear stage of the retrieval operator. The rms retrieval error is 1.5 km for cumulus-stage cells with tops ranging from 1.5 to 16 km. The sensitivity of nadiral 118-GHz spectra to the cell-top altitude is predominantly due to the scattering and absorption of radiation originating from low, warm atmospheric levels by colder liquid and frozen precipitation This effect causes cold perturbations in the brightness spectrum, which typically become stronger with increasing cell-top altitude.

Gasiewski, A. J.↗

Evolution of a phase separated gravity independent bioreactor

The evolution of a phase-separated gravity-independent bioreactor is described. The initial prototype, a zero head-space manifold silicone membrane based reactor, maintained large diffusional resistances. Obtaining oxygen transfer rates needed to support carbon-recycling aerobic microbes is impossible if large resistances are maintained. Next generation designs (Mark I and II) mimic heat exchanger design to promote turbulence at the tubing-liquid interface, thereby reducing liquid and gas side diffusional resistances. While oxygen transfer rates increased by a factor of ten, liquid channeling prevented further increases. To overcome these problems, a Mark III reactor was developed which maintains inverted phases, i.e., media flows inside the silicone tubing, oxygen gas is applied external to the tubing. This enhances design through changes in gas side driving force concentration and liquid side turbulence levels. Combining an applied external pressure of 4 atm with increased Reynolds numbers resulted in oxygen transfer intensities of 232 mmol O2/l per hr (1000 times greater than the first prototype and comparable to a conventional fermenter). A 1.0 liter Mark III reactor can potentially deliver oxygen supplies necessary to support cell cultures needed to recycle a 10-astronaut carbon load continuously.

Villeneuve, Peter E.↗