Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Flaming Moe

Current clamp measurements collected on various small electronic devices. Details on the data set can be found in J. M. Vann, T. P. Karnowski, R. Kerekes, C. D. Cooke and A. L. Anderson, A Dimensionally Aligned Signal Projection for Classification of Unintended Radiated Emissions, in IEEE Transactions on Electromagnetic Compatibility, vol. 60, no. 1, pp. 122-131, Feb. 2018, doi: 10.1109/TEMC.2017.2692962.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TAS::89 0927::TAS RECOVERY - The Lean Green Energy Controller Machine

Achieving efficiency improvements and providing demand-response programs have been identified as key elements of our national energy initiative. The residential market is the largest, yet most difficult, segment to engage in efforts to meet these objectives. This project developed Energy Management System that engages the consumer and enables Smart Grid services, applications, and business processes to address this need. Our innovative solution provides smart controller providing dynamic optimization of energy consumption for the residential energy consumer. Our solution extends the technical platform to include a cloud based Internet of Things (IoT) aggregation of data sensors and actuators the go beyond energy management and extend to life style services provided through compelling mobile and console based user experiences.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

QXF Cold Mass Friction Test

The purpose of this test is to determine the longitudinal force on the stainless steel shell that is required to break the friction between the stainless steel shell and the aluminum shell underneath. This is achieved by suspending the short magnet between two backing plates on the eight grade 8 threaded rods which replace the 8 stainless steel toke tie rods in the magnet assembly. Eight hydraulic cylinders are mounted to each backing plate. Six, 22" sections of the stainless steel shell are welded in place on the magnet, each of which has a slightly different developed length, starting from the baseline design, and becoming progressively looser. A pushing flange is mounted to the stainless steel shells via small tack welds. Four load cells are then attached to the flange at designated points, while additional tooling is attached to each of the cylinders to facilitate the transfer of force from the cylinders to the stainless steel shell During the test, the cylinders will be slowly energized to no more than 7000 psi, with a resultant, longitudinal force on the flange of no more than 125,400 lbf. For each set of shells, the test ends when the load cell monitoring software detects a sharp decrease in force. This will indicate that the friction has broken. The cullenders will then be de-energized and the cycle will repeat for the next test. Welding operations outlined in the procedure (US-HiLumi-doc-4200) are outside the scope of the HA as the work is occurring under a previously-issued burn permit by qualified welders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether supplemental dehumidification is a needed and effective investment to promote these long term standards. Data logging equipment was installed at eight test homes in July, 2012 and later at two more test homes in January, 2013. Interior conditions and various end-use loads were monitored until November 7th, 2013. The mechanical systems at each of the 10 homes were commissioned by BSC to ensure consistent operation between each of the homes and to fully comply with the intended mechanical design. PHA-1 to 8 - Energy Savings: 21.8-18.9%, Company: Project Home Again (PHA); Address New Orleans, LA 70112, House Count: 8 BDC-1 - Energy Savings: 28.8%, Company: Broadmoor Development Corporation (BDC); Address New Orleans, LA 70112, House Count: 2

Array↗

Laboratory upwelled radiance and reflectance spectra of Kerr reservoir sediment waters

Reflectance, chromaticity, and several other physical and chemical properties were measured for various water mixtures of bottom sediments taken from two sites at Kerr Reservoir, Virginia. Mixture concentrations ranged from 5 to 1000 ppm by weight of total suspended solids (TSS) in filtered deionized tap water. The two sets of radiance and reflectance spectra obtained were similar in shape and magnitude for comparable values of TSS. Upwelled reflectance was observed to be a nonlinear function of TSS with the degree of curvature a function of wavelength. Sediment from the downstream site contained a greater amount of particulate organic carbon than from the upstream site. No strong conclusions can be made regarding the effects of this difference on the radiance and reflectance spectra. Near-infrared wavelengths appear useful for measuring highly turbid water with concentrations up to 1000 ppm or more. Chromaticity characteristics do not appear useful for monitoring sediment loads above 150 ppm.

Witte, W. G.↗

Behavior of damaged graphite/epoxy laminates under compression loading

The influence of three different resin systems on the damage tolerance of graphite/polymer laminates was evaluated. Testing consisted of both static compression and cyclic compression evaluation of 10.2 by 15.2 by 0.5 cm (4 by 6 by 0.2 in) laminates with circular holes, simulated delaminations, and low velocity impact. Damage growth under steadily increasing compression and cyclic compression loading was monitored. Damage size and impact-induced failures for the three materials were compared. Of the three material systems evaluated, the one most tolerant to impact damage exhibited the least delamination within the cross section due to impact, the highest transverse tension strain to failure, and the largest crack opening force, as determined from double cantilever beam tests.

Byers, B. A.↗

AD-1 oblique wing aircraft program

A NASA program for evaluation of the handling and flying characteristics of the AD-1 oblique wing aircraft is discussed. The vehicle was flown to compare wind tunnel predictions with aerodynamic data, explore the control system requirements, and obtain a preliminary assessment of the aeroelastic effects. The fiberglass sandwich skin aircraft is designed for 8 g positive and 4 g negative loading at 175 knots, while the wing pivot can withstand 25 g loading. Flight monitoring was accomplished with a 41 channel pulse code modulation system for telemetry and by averaging of pilot ratings. Maneuvering tests are outlined, noting that pilot ratings indicated acceptable handling at up to 50 deg sweep. It is concluded that acceptable flying qualities can be achieved with a 60 deg sweep, and that aeroelastic tailoring can be used to satisfy cruise design technology.

Mcmurtry, T. C.↗

Electric-Power System Simulator

Shows different combinations of generation, storage, and load components: display, video monitor with keyboard input to microprocessor, and video monitor for display of load curves and power generation. Planning tool for electric utilities, regulatory agencies, and laymen in understanding basics of electric-power systems operation.

Caldwell, R. W.↗

Development of a Pre-Prototype Power Assisted Glove End Effector for Extravehicular Activity

The purpose of this program was to develop an EVA power tool which is capable of performing a variety of functions while at the same time increasing the EVA crewmember's effectiveness by reducing hand fatigue associated with gripping tools through a pressurized EMU glove. The Power Assisted Glove End Effector (PAGE) preprototype hardware met or exceeded all of its technical requirements and has incorporated acoustic feedback to allow the EVA crewmember to monitor motor loading and speed. If this tool is to be developed for flight use, several issues need to be addressed. These issues are listed.

Source record↗

In Situ Radiography During Tensile Tests

Laboratory system for testing specimens of metal-, ceramic-, and intermetallic-matrix composite materials incorporates both electromechanical tensile-testing subsystem and either of two imaging subsystems that take x-ray photographs of specimens before, during, and after tensile tests. Used to test specimens of reaction-bonded silicon nitride reinforced with silicon carbide fibers (SiC/RBSN) considered for high-temperature service in advanced aircraft turbine engines. Provides data on effects of preexisting flaws (e.g., high-density impurities and local variations of density) on fracture behavior. Accumulated internal damage monitored during loading. X-ray source illuminates specimen in load frame while specimen is pulled. X-ray images on film correlated with stress-vs.-strain data from tensile test.

Baaklini, George Y.↗

A conflict of water and fire: Remote sensing imagery of the Uinkaret Volcanic Field, Grand Canyon, Arizona

The sedimentary geology of the western Grand Canyon consists of gently northeast dipping sandstones, shales, and carbonates. However, due to facies changes within the units, the geomorphology varies from that seen by visitors at the National Park Headquarters. There, the cliff and slope expression of the rocks is replaced in the west by a series of mesas, ridges, and horizontal platforms. The largest of these occurs on the Esplanade Sandstone within the Supai Formation. The Esplanade is formed by slope retreat of the overlying units and resistance to erosion by the underlying limestones. It is onto this platform that the lavas of the Uinkaret Plateau were emplaced. The Uinkaret lava field lies 120 km south of St. George, Utah and is tectonically defined by two major normal faults -- the Hurricane to the west and the Toroweap to the east. The purpose of this investigation was to collect visible, near and thermal infrared data at different periods of the day and year. It is expected that these data will provide the ability to retrieve water temperatures; monitor sediment loads; map and examine any changes in the near shore vegetation communities and understand some of the intricacies of the geology. This paper will serve, to some degree, as a progress report on the Grand Canyon study, since only a fraction of the data has been received and processed thus far. Data from the Thermal Infrared Multispectral Scanner (TIMS) and the Landsat Thematic Mapper simulator (NS001) were acquired simultaneously on April 4, 1994. A second data acquisition occurred on August 27, 1994. Initial analysis of the TIMS data indicates a remarkably noise-free data set with minimal atmospheric attenuation. environments is evident.

Ramsey, Michael S.↗

Space Shuttle Hypergol Load Determination Using Nonintrusive Ultrasonic Flowmeters

Space Shuttle preflight hypergol oxidizer and fuel loading were monitored using a nonintrusive flow measurement system (NFMS) during preflight operation. A pair of 4-megahertz ultrasonic transducers measured the flow rate using a transit-time flow measurement technique. Using wireless cellular phone technology, flow-rate data was monitored and recorded. Excellent correlation was observed between the flow profiles measured using the proposed nonintrusive ultrasonic flowmeters (UFM's) and those made from conventional intrusive turbine meters (TFM). Based on the preliminary tests, it is concluded that the nonintrusive method of flow measurement has the same or higher accuracy, is simpler, and costs less than the existing TFM. Benefits of UFM's include a highly flexible, cost-effective, reliable, hazard free, and streamlined hypergol operation. Redundant installation of ultrasonic flowmeters was recommended for a few more launches prior to the replacement of the existing TFM.

Werlink, Rudolph↗

Randomness fault detection system

A method and apparatus are provided for detecting a fault on a power line carrying a line parameter such as a load current. The apparatus monitors and analyzes the load current to obtain an energy value. The energy value is compared to a threshold value stored in a buffer. If the energy value is greater than the threshold value a counter is incremented. If the energy value is greater than a high value threshold or less than a low value threshold then a second counter is incremented. If the difference between two subsequent energy values is greater than a constant then a third counter is incremented. A fault signal is issued if the counter is greater than a counter limit value and either the second counter is greater than a second limit value or the third counter is greater than a third limit value.

Russell, B. Don↗

Intermountain West Wildland Fires: Mapping Tree Mortality and Burn Patches using NASA Earth Observations to Determine Fire Risk and Inform Fire Management Practices

Within the intermountain west, monitoring fuel loads is a major concern for wildland fire management efforts. To address this concern, we partnered with the U.S. Forest Service to inform the agency which forested areas should be prioritized for prescribed burning and fuel reduction near human communities in the Bridger-Teton National Forest, Wyoming. We created burn maps, fuel load maps, and a tutorial document to identify forest impact trends and provide the partner with the tools to replicate project methods for expansion to other wildfire crisis strategy sites. These end products were made using two NASA Earth observations: Landsat 8 Operational Land Imager and Shuttle Radar Topography Mission. Based on our random forest analysis, our maps identified 998 acres within the Wildland Urban Interface that are predicted to have high fuel loading and high burn severity within the Bridger-Teton National Forest. Forested areas closer to heavily populated areas such as Jackson, Kelly, Moran, New Forks Lake, and Star Valley Ranch should be prioritized for fuel reduction. However, our random forest model analysis was limited to using vegetation and topographical indices with no field data for model validation. Therefore, future studies should use field data for model validation to improve model accuracy and additionally incorporate Global Ecosystem Dynamics Investigation data into models to create better predictions of forested areas with high fuel load and high burn severity.

Remote Sensing↗

Herpesviruses in Saliva and Their Clinical Significance

Saliva has been used as a source of biological markers for a wide spectrum of normal and disease states for a long time. It is a non-invasive, easily accessible, and self-collected body fluid that contains a variety of measurable biological substances. While mostly water, saliva also contains ions, carbohydrates, proteins and peptides, exfoliated cells, nucleic acids, and microorganisms. Saliva can reflect tissue levels of some natural substances and a large variety of molecules introduced for therapeutic use, emotional status; hormonal status, immunological status, neurological effects, and nutritional and metabolic status. It can also be used to monitor a variety of drugs including marijuana, cocaine, and alcohol. It is the most cost-effective approach for screening large population in community mass screening programs and for longitudinal sampling of hospitalized individuals aimed at monitoring viral load dynamics and treatment response. During the COVID-19 pandemic, scientific evidence emerged indicating that molecular tests performed on saliva have diagnostic sensitivity and specificity comparable to those observed with nasopharyngeal swabs for SARS-CoV-2 RNA detection. The presence of IgA and IgG antibodies at the mucosal level has been demonstrated to influence the progression of viral infection and the severity of clinical manifestation. As saliva contains both respiratory secretions and immunological components, it has wide applications, ranging from clinical diagnostics to post-vaccine disease burden and immunity surveillance.

Douglass Diak↗

Hybrid Ground-Source Heat Pump Installations: Experiences, Improvements and Tools

One innovation to ground-source heat pump (GSHP, or geothermal systems is the hybrid GSHP (HyGSHP) system. A HyGSHP system can dramatically decrease the first cost of GSHP systems by using conventional technology (such as a cooling tower or a boiler) to meet a portion of the peak heating or cooling load. We monitored and analyzed three buildings employing HyGSHP systems (two cooling-dominated, one heating-dominated) to demonstrate the performance of the hybrid approach. The buildings were monitored for a year and the measured data was used to validate models of each system. Additionally, we used the models to analyze further improvements to the hybrid approach and established that it has positive impacts, both economically and environmentally. We also documented the lessons learned by those who design and operate the three systems, including discussions of equipment sizing, pump operation, and cooling tower control. Finally, we described the measured data sets and models from this work and have made them freely available for further study of hybrid systems.

15 GEOTHERMAL ENERGY↗

Technology Solutions Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana

The purpose of this project by Building Science Corporation was to evaluate the humidity control performance of new single family high performance homes, and compare the interior conditions and mechanical systems operation between two distinct groups of houses: homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were 10 single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012, and interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space; however, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

BSC↗

Disaggregating Smart Meter Data to Identify Electric Loads and Control Opportunities

As utility data, such as smart meter data, becomes more broadly available, there is general interest in using it to improve utility operations and enable adoption of other advanced technology - such as solar photovoltaics (PV), energy storage, and controls. We explore one such use case - identifying electric resistance water heaters from smart meter data, as well as characterizing their potential for load-shifting to support grid voltage stability under high-penetration PV adoption. This paper shows the limitation of typical 15-minute data, and how shortterm capture of additional 1-minute data is needed to enable the desired application. Results indicate about 4 kWh water heating load can be shifted to align with peak sun hours in a low use home. This methodology is an example, and can be adapted to other grid-integrated efficient building use cases.

14 SOLAR ENERGY↗