Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Progress Update on the In Situ Load Retention Aging Vessel

To improve upon our conventional thermally accelerated aging study methods which require periodic interruption of aging to perform load testing in an Instron machine, a new aging system is being developed to: (1) automate/facilitate data acquisition/analysis, (2) improve data quality, and (3) enable uninterrupted aging conditions (compression, temperature, atmosphere) which represents the service condition. In FY24, a thermal aging vessel instrumented with load cells was fabricated and tested. That unit demonstrated the primary function of the vessel: to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary objective, not realized in the unit due to inadequate sealing, was to enable a single initial nitrogen backfill (as opposed to a continuous purge) and gas sampling of the vessel headspace during thermal aging. Heating of the vessel was achieved using a custom heater jacket.

36 MATERIALS SCIENCE↗

Electrical appliance energy consumption control methods and electrical energy consumption systems

Electrical appliance energy consumption control methods and electrical energy consumption systems are described. In one aspect, an electrical appliance energy consumption control method includes providing an electrical appliance coupled with a power distribution system, receiving electrical energy within the appliance from the power distribution system, consuming the received electrical energy using a plurality of loads of the appliance, monitoring electrical energy of the power distribution system, and adjusting an amount of consumption of the received electrical energy via one of the loads of the appliance from an initial level of consumption to an other level of consumption different than the initial level of consumption responsive to the monitoring.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal Performance of Vegetative Roofing Systems

Vegetative roofing, otherwise known as green or garden roofing, has seen tremendous growth in the last decade in the United States. The numerous benefits that green roofs provide have helped to fuel their resurgence in industrial and urban settings. There are many environmental and economical benefits that can be realized by incorporating a vegetative roof into the design of a building. These include storm-water retention, energy conservation, reduction in the urban heat island effect, increased longevity of the roofing membrane, the ability of plants to create biodiversity and filter air contaminants, and beautification of the surroundings by incorporating green space. The vegetative roof research project at Oak Ridge National Laboratory (ORNL) was initiated to quantify the thermal performance of various vegetative roofing systems relative to black and white roofs. Single Ply Roofing Institute (SPRI) continued its long-term commitment to cooperative research with ORNL in this project. Low-slope roof systems for this study were constructed and instrumented for continuous monitoring in the mixed climate of East Tennessee. This report summarizes the results of the annual cooling and heating loads per unit area of three vegetative roofing systems with side-by-side comparison to black and white roofing systems as well as a test section with just the growing media without plants. Results showed vegetative roofs reduced heat gain (reduced cooling loads) compared to the white control system due to the thermal mass, extra insulation, and evapo-transpiration associated with the vegetative roofing systems. The 4-inch and tray systems reduced the heat gain by approximately 61%, while the reduction with the 8-inch vegetative roof was found to be approximately 67%. The vegetative roofing systems were more effective in reducing heat gain than in reducing heat losses (heating loads). The reduction in heat losses for the 4-inch and tray systems were found to be approximately 40% in the mixed climate of East Tennessee. It should be noted that these values are climate dependent. Vegetative roofs also reduced the temperature (heat exposure) and temperature fluctuations (thermal stress) experienced by the membrane. In the cooling season of East Tennessee, the average peak temperature of the 4-inch and tray systems was found to be approximately 94 F cooler than the control black roofing system. The average temperature fluctuations at the membrane for the 4-inch and tray systems were found to be approximately 10 F compared to 125 F for black and 64 F for white systems. As expected, the 8-inch vegetative roof had the lowest fluctuations at approximately 2 F. Future work will include modeling of the energy performance of vegetative roof panels in the test climate of East Tennessee. The validated model then will be used to predict energy use in roofs with different insulation levels and in climates different from the test climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pacific Northwest GridWise™ Testbed Demonstration Projects; Part II. Grid Friendly™ Appliance Project

Fifty residential electric water heaters and 150 new residential clothes dryers were modified to respond to signals received from underfrequency, load-shedding appliance controllers. Each controller monitored the power-grid voltage signal and requested that electrical load be shed by its appliance whenever electric power-grid frequency fell below 59.95 Hz. The controllers and their appliances were installed and monitored for more than a year at residential sites at three locations in Washington and Oregon. The controllers and their appliances responded reliably to each shallow underfrequency event—an average of one event per day—and shed their loads for the durations of these events. Appliance owners reported that the appliance responses were unnoticed and caused little or no inconvenience for the homes’ occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Grid Enabled EVSE

The combined team of GE Global Research, Federal Express, National Renewable Energy Laboratory, and Consolidated Edison has successfully achieved the established goals contained within the Department of Energy’s Smart Grid Capable Electric Vehicle Supply Equipment funding opportunity. The final program product, shown charging two vehicles in Figure 1, reduces by nearly 50% the total installed system cost of the electric vehicle supply equipment (EVSE) as well as enabling a host of new Smart Grid enabled features. These include bi-directional communications, load control, utility message exchange and transaction management information. Using the new charging system, Utilities or energy service providers will now be able to monitor transportation related electrical loads on their distribution networks, send load control commands or preferences to individual systems, and then see measured responses. Installation owners will be able to authorize usage of the stations, monitor operations, and optimally control their electricity consumption. These features and cost reductions have been developed through a total system design solution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

FEMCAM Analysis of SULTAN Test Results for ITER Nb3SN Cable-conduit Conductors

Performance degradation due to filament fracture of Nb3 Sn cable-in-conduit conductors (CICCs) is a critical issue in large-scale magnet designs such as ITER which is currently being constructed in the South of France. The critical current observed in most SULTAN TF CICC samples is significantly lower than expected and the voltage-current characteristic is seen to have a much broader transition from a single strand to the CICC. Moreover, most conductors exhibit the irreversible degradation due to filament fracture and strain relaxation under electromagnetic cyclic loading. With recent success in monitoring thermal strain distribution and its evolution under the electromagnetic cyclic loading from in situ measurement of critical temperature, we apply FEMCAM which includes strand filament breakage and local current sharing effects to SULTAN tested CICCs to study Nb3 Sn strain sensitivity and irreversible performance degradation. FEMCAM combines the thermal bending effect during cool down and the EM bending effect due to locally accumulating Lorentz force during magnet operation. It also includes strand filament fracture and related local current sharing for the calculation of cable n value. In this paper, we model continuous performance degradation under EM cyclic loading based on strain relaxation and the transition broadening upon cyclic loading to the extreme cases seen in SULTAN test data to better quantify conductor performance degradation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of crystallization on micro-mechanical behavior of polyethylene nanocomposites using Raman spectroscopy

Recent work has shown that nanoparticles can be ordered in semicrystalline polymers by controlling the crystallization rate, specifically by forcing them to migrate to the amorphous regions of the lamellar morphology. Here, we study the micromechanical behavior of neat polyethylene and silica/polyethylene nanocomposites filled with 15 nm brush-modified silica in the quenched and slow-crystallized organized state. The molecular response to loading in tension was monitored with Raman spectroscopy using the peaks associated with crystalline and amorphous regions. The addition of nanofillers dramatically reduced the shift in the amorphous peaks, indicating that in addition to carrying some load, the brush-modified nanoparticles may be acting as tie molecules that restrict amorphous deformation. The higher degree of lamellar organization and the organization of the nanoparticles also impacted the crystalline peak shifts, but more subtly.

Polyethylene↗

A Scalable Online Monitoring System Based on Elasticsearch for Distributed Data Acquisition in Cms

The part of the CMS Data Acquisition (DAQ) system responsible for data readout and event building is a complex network of interdependent distributed applications. To ensure successful data taking, these programs have to be constantly monitored in order to facilitate the timeliness of necessary corrections in case of any deviation from specified behaviour. A large number of diverse monitoring data samples are periodically collected from multiple sources across the network. Monitoring data are kept in memory for online operations and optionally stored on disk for post-mortem analysis. We present a generic, reusable solution based on an open source NoSQL database, Elasticsearch, which is fully compatible and non-intrusive with respect to the existing system. The motivation is to benefit from an off the-shelf software to facilitate the development, maintenance and support efforts. Elasticsearch provides failover and data redundancy capabilities as well as a programming language independent JSON-over-HTTP interface. The possibility of horizontal scaling matches the requirements of a DAQ monitoring system. The data load from all sources is balanced by redistribution over an Elasticsearch cluster that can be hosted on a computer cloud. In order to achieve the necessary robustness and to validate the scalability of the approach the above monitoring solution currently runs in parallel with an existing in-house developed DAQ monitoring system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extended Storage of High Burn-up Fuel Cask R and D Project - 16591

Under contract by EPRI and DOE, AREVA Federal Services LLC (AFS) is leading a team consisting of AREVA Inc. and Dominion Virginia Power (Dominion) to develop and conduct a full-scale confirmatory Research project with HBU fuel. A test plan was developed using an existing AREVA Transnuclear (TN) TN-32 bolted storage cask with a modified, specially instrumented lid to be engineered and then loaded with multiple cladding types of HBU pressurized water reactor (PWR) UNF from Dominion's North Anna Power Station (this modified cask is identified as TN-32B). Seven specially designed thermocouple lances, each containing nine detectors, will be inserted into the designated fuel assembly guide tubes through the modified cask lid. The loaded cask with the monitoring system will be placed into dry storage on the existing North Anna Independent Spent Fuel Storage Installation (ISFSI) pad for a period of extended monitoring. In addition, design modifications to the lid have been incorporated to permit periodic gas sampling of the cask internals during the storage period on the ISFSI pad. The fuel selected for this research project ranges in average assembly burnup between 50 GWD/MTU to 67 GWD/MTU. The instrumentation used to collect the thermal data is very similar to in-core thermocouple detectors used at nuclear power plants and is considered very reliable for this application. Prior to cask loading at North Anna, a series of 'fit up' tests will be performed at the fabricator to ensure proper alignment, fit and function of the modified cask and related instrumentation and equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extended Storage of High Burn-up Fuel Cask R and D Project - 17145

Under contract by EPRI and DOE, AREVA Federal Services LLC (AFS) is leading a team consisting of AREVA Inc. and Dominion Virginia Power (Dominion) to develop and conduct a full-scale confirmatory Research project with HBU fuel. A test plan was developed using an existing TN Americas (TN) TN-32 bolted storage cask with a modified, specially instrumented lid to be engineered and then loaded with multiple cladding types of HBU pressurized water reactor (PWR) UNF from Dominion's North Anna Power Station (this modified cask is identified as TN-32B). Seven specially designed thermocouple lances, each containing nine detectors, will be inserted into the designated fuel assembly guide tubes through the modified cask lid. The loaded cask with the monitoring system will be placed into dry storage on the existing North Anna Independent Spent Fuel Storage Installation (ISFSI) pad for a period of extended monitoring. In addition, design modifications to the lid have been incorporated to permit periodic gas sampling of the cask internals during the storage period on the ISFSI pad. The fuel selected for this research project ranges in average assembly burnup between 50 GWD/MTU to 67 GWD/MTU. The instrumentation used to collect the thermal data is very similar to in-core thermocouple detectors used at nuclear power plants and is considered very reliable for this application. Prior to cask loading at North Anna, a series of 'fit up' tests will be performed at the fabricator to ensure proper alignment, fit and function of the modified cask and related instrumentation and equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Cooperative Multi-Agent Deep Reinforcement Learning Framework for Real-Time Residential Load Scheduling

Internet-of-Things (IoT) enabled monitoring and control capabilities are enabling increasing numbers of household users with controllable loads to actively participate in smart grid energy management. Realizing an efficient real-time energy management system that takes advantage of these developments requires novel techniques for managing the increased complexity of the control action space in resolving multiple challenges such as the uncertainty in energy prices and renewable energy output along with the need to satisy physical grid constraints such as transformer capacity. Addressing these challenges, we develop a multi-household energy management framework for residential units connected to the same transformer and containing DERs such as PV, ESS and controllable loads. The goal of our framework is to schedule controllable household appliances and ESS such that the cost of procuring electricity from the utility over a horizon is minimized while physical grid constraints are satisfied at each scheduling step. Traditional energy management frameworks either perform global optimization to satisfy grid constraints but suffer from high computational complexity (for example Integer Program, Mixed Integer Programming frameworks and centralized reinforcement learning) or perform decentralized real-time energy management without satisfying global grid constraints (for example multi-agent reinforcement learning with no cooperation). In contrast, we propose a cooperative multiagent reinforcement learning (MARL) framework that i) operates in real-time, and ii) performs explicit collaboration to satisfy global grid constraints. The novelty in our framework is two fold. Firstly, our framework trains multiple independent learners (IL) for each household in parallel using historical data and performs real-time inferencing of control actions using the most recent system state. Secondly, our framework contains a low complexity knapsack based cooperation agent which combines the outputs of ILs to minimize cost while satisfying grid constraints. Simulation results show that our cooperative MARL approach achieves significant cost improvement over centralized reinforcement learning and day-ahead planning baselines. Moreover, our approach strictly satisfies physical constraints with no apriori knowledge of system dynamics while the baseline approaches have occasional violations. We also measure the training and inference time by ranging the number of households from 1 to 25. Results show that our cooperative MARL approach scales best among various approaches.

14 SOLAR ENERGY↗

Automated instrument for assessing abrasives

An automated instrument for monitoring the destructive compressive load on abrasive grains (measuring 400–1250 μm) between two rotating rollers has been developed. A modernized version of the instrument also permits determination of the grain size, shape, and microgeometric and topographic characteristics of abrasives. Equipped with a photometric unit and a module for processing numerical information, the modernized instrument permits multiple recording of each particle by six cameras (in both directions along three orthogonal axes), with assessment of the microgeometry. Such information regarding the grains, along with identification of their shape (plates, needles, isometric form, etc.), permits their quality assessment; their subsequent separation on vibrational sorters; and their most effective use in the abrasive machining of materials characterized by different hardness, brittleness, and composition, including composites.

36 MATERIALS SCIENCE↗

Energy Implications of In-Line Filtration in California

Occupant concern about indoor air quality (IAQ) issues has led to the increased use of more effective air filters in residential heating and cooling systems. This study performed measurements in ten California houses to determine the effects of changing filter performance and related characteristics on the energy use of the heating and cooling systems. Multiple filters were evaluated covering a wide range of filter effectiveness from simple low filtration fiberglass filters up to high efficiency filters that might be used by occupants concerned about IAQ. Sophisticated analysis and simulation tools used the field-testing results to determine filter impacts for a wide range of parameters and California climates. The results indicate that for MERV 10/11/13 filters the effects on energy use are moderate (<5%) over a wide range of performance conditions and climates. Using higher MERV 16 filters can lead to significantly increased energy use (>5%). The high airflow resistance of MERV 16 filters led to excess noise in some test houses from air bypassing the filter and the blower motor. Filter loading rates varied more from house to house than by MERV rating and overall were quite low in many of the homes. Filter related energy use does not need to be addressed for filters of MERV 10/11/13 and MERV 16 filters should only be used with low leakage tested ducts unless the filter is mounted at the blower compartment. MERV 16 filters should only be used if the filter area is sufficient to prevent noise issues and if the duct system has low air flow resistance and low leakage. Filters should be labeled for their air flow resistance, or static pressure at a particular flow rate, that would allow codes and standards to reference a particular performance specification and allow contractors and homeowners to make informed purchases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗