Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load coordination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Communication Requirements for Price-Based Grid Coordination

Meeting ambitious goals for carbon reduction and supporting an electric grid with high levels of renewable energy supply will require significant flexibility from the demand side. This paper outlines a system architecture and communication technology infrastructure to enable dynamic pricing to be used to finely tune coordination between the grid and its customers. Taking a cue from the success of Internet architecture, this system — Price-Based Grid Coordination — emphasizes simplicity and universality. It enables a wide variety of ways for prices and other signals to pass from the grid to individual flexible loads, including multiple possible locations for the intelligence that combines price signals with device functional needs. The paper includes a reference data model to describe how information from the utility level can be conveyed to customer devices, but independent of any particular protocol. The paper also summarizes technology standards development needs, and reviews research needs to address the full spectrum of coordination scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Augmented Kalman filter with a reduced mechanical model to estimate tower loads on a land-based wind turbine: a step towards digital-twin simulations

This article presents an application of the Kalman filtering technique to estimate loads on a wind turbine. The approach combines a mechanical model and a set of measurements to estimate signals that are not available in the measurements, such as wind speed, thrust, tower position, and tower loads. The model is severalfold faster than real time and is intended to be run online, for instance, to evaluate real-time fatigue life consumption of a field turbine using a digital twin, perform condition monitoring, or assess loads for dedicated control strategies. The mechanical model is built using a Rayleigh–Ritz approach and a set of joint coordinates. We present a general method and illustrate it using a 2-degrees-of-freedom (DOF) model of a wind turbine and using rotor speed, generator torque, pitch, and tower-top acceleration as measurement signals. The different components of the model are tested individually. The overall method is evaluated by computing the errors in estimated tower-bottom-equivalent moment from a set of simulations. From this preliminary study, it appears that the tower-bottom-equivalent moment is obtained with about 10 % accuracy. The limitation of the model and the required steps forward are discussed.

17 WIND ENERGY↗

A Load Switching Group based Feeder-level Microgrid Energy Management Algorithm for Service Restoration in Power Distribution System

This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to be formed on the feeder and selecting the optimal supply path. Customer comfort is accounted for by maximizing the supply duration in the customer preferred service period and enforcing a minimum service duration. The proposed method is demonstrated on a modified IEEE 33-bus system using actual customer data. Simulation results show that the LSG-EMS successfully coordinates multiple grid-forming sources by selecting an optimal supply topology that maximizes the supply period of both the critical and noncritical loads while minimizing customer service interruptions in the service restoration process.

Hu, Rongxing↗

Systems and methods for randomized energy draw or supply requests

The present disclosure can provide a distributed and anonymous approach to demand response of an electricity system. The approach can conceptualize energy consumption and production of distributed-energy resources (DERs) via discrete energy packets that are coordinated by a cyber computing entity that grants or denies energy packet requests from the DERs. The approach leverages a condition of a DER, which is particularly useful for (1) thermostatically-controlled loads, (2) non-thermostatic conditionally-controlled loads, and (3) bi-directional distributed energy storage systems, among others. In a first aspect of the present approach, each DER independently requests the authority to switch on for a fixed amount of time (i.e., packet duration). The coordinator determines whether to grant or deny each request based electric grid and/or energy or power market conditions. In a second aspect, bi-directional DERs, such as distributed-energy storage systems (DESSs) are further able to request to supply energy to the grid.

Frolik, Jeff↗

EUREICA: Efficient UltRa Endpoint IoT-enabled Coordinated Architecture

The electricity grid has evolved from a physical system to a cyber-physical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) that include renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. The purpose of this project was to develop a framework ((Efficient, Ultra-REsilient, IoT-Coordinated Assets, or EUREICA)for achieving grid resilience through suitably coordinated assets including a network of Internet of Things (IoT) devices, and a local electricity market (LEM) to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. Experiments conducted during this project demonstrated that, with this SA, a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. The demonstrations were carried out using a variety of high-fidelity co-simulation platforms, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

14 SOLAR ENERGY↗

Ethylene oxide functionalization enhances the ionic conductivity of a MOF

Varying the degree of ethylene oxide (EO) functionalization of the zirconium MOF UiO-68 affords two novel MOFs; UiO-68-EO and UiO-68-2EO exhibit solvent-free ionic conductivity upon loading LiTFSI in their pores. Furthermore, incorporating EO chains provides a pathway for lithium ion migration between the coordinated sites and results in an ionic conductivity of 3.8 × 10 –7 S cm –1 and 3.9 × 10 –4 S cm –1 at 90 °C for UiO-68-EO/LiTFSI and UiO-68-2EO/LiTFSI respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hierarchical Distribution System Adaptive Restoration with Diverse Distributed Energy Resources

Distributed energy resources (DERs) can be utilized as alternative power sources for fast service recovery in cases of distribution system outages. However, the diverse characteristics and stochastic nature of DERs impose challenges on the optimal operation of di-verse resources during the restoration phase. Here, we introduce a hierarchical structure to coordinate distribution system entities and propose an adaptive restoration strategy to sustain a reliable power supply to outage loads in an unbalanced distribution system utilizing DERs. An efficient system reconfiguration model is developed to guarantee the radiality of restoration islands. The flexibility of DERs is evaluated by a novel method that focuses on the cumulative energy consumption, the superiority of which is also proven. Model predictive control (MPC) is adopted to enable the adjustment of system topology and DER operation strategies based on up-to-date data. The performance of the proposed restoration model is validated on a modified IEEE 123-bus test system. Moreover, the effectiveness of the proposed novel flexibility assessment and the MPC-based adaptive restoration strategy are verified through comparative studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Transitions Initiative Partnership Project: City and Borough of Sitka, Alaska - Modeling and Controls Assistance and Renewable Energy Resource Assessment [Slides]

This presentation provides a summary of the ETIPP project objectives and findings for Sitka, Alaska, including sizing of wind penetration, dynamic models, and analysis of efficiency of load control, stability and grid control impacts of wind capacity expansions and locations, and wind-hydro control coordination.

17 WIND ENERGY↗

Empirical Assessment of Interregional Coordination to Support Resource Adequacy [Slides]

This study examines where interregional transmission could most effectively support resource adequacy in the contiguous United States. We use hourly load, renewable generation, and real-time price data from 2016–2023 for 18 planning subregions to identify periods of elevated adequacy risk, defined as the top 100 annual hours of net load and wholesale prices in each region. We then measure the temporal coincidence of these peak periods between adjacent regions and compare price patterns to assess the potential for capacity sharing. Results show that NorthernGrid West, a winter-peaking region, has low coincidence of peak net load with its summer-peaking neighbors, indicating high potential for interregional support. In contrast, regions in the Northeast have highly coincident peak periods, suggesting limited adequacy benefits from additional transmission. Price-based analysis shows peak-hour differences in the Midwest and between ERCOT and neighboring regions, indicating potential economic benefits from increased transfers. The findings provide an empirical screening of where transmission may offer the greatest reliability benefits without adding new generation capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Energy Service Interface for Distributed Energy Resources

Renewable energy resources, particularly wind and solar photovoltaic, are becoming significant contributors to electric power generation. These re-sources will contribute towards achieving sustainable electric power systems. However, renewable resources will dramatically increase the demand for flexible power system operations. This paper proposes an energy service interface that will allow aggregated distributed energy resources, such as residential loads and inverter-based systems, to participate in NERC-defined smart energy reliability services. Such cyber-physical systems will increase system flexibility by ensuring match between energy supply and energy demand.Aggregation and coordinated dispatch of millions of distributed energy resources will require development of large-scale computing networks. Several smart grid interface-enabling technologies, including IEEE 2030.5, Common Smart Inverter Profile, SunSpec Modbus, and CTA 2045, are discussed. Residential loads are categorized by their static and dynamic energy characteristics to identify services in which they can participate. The business model for the energy services interface as well as probabilistic modeling for resource estimation are highlighted as future considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bidentate N‐based Ligands for Highly Reusable, Ligand‐coordinated, Supported Pt Hydrosilylation Catalysts

Abstract A significant challenge in designing supported metal‐ligand catalysts for solution‐phase reactions is the stabilization of the metal active sites against leaching into solution. Here, we examine alkene hydrosilylation reactions as model systems to improve the stability of highly dispersed Pt using a metal‐ligand coordination strategy on high surface area oxide supports. By evaluating a series of bidentate N‐based ligands, we demonstrate several design strategies to improve stability of the highly dispersed Pt 2+ centers against leaching, while maintaining a high level of catalytic activity, selectivity, and recyclability for alkene hydrosilylation batch reactions under mild conditions. These involve a bi‐functional approach to ligand design, which considers interaction to the support and a well‐defined coordination environment for the metal active site. Three strategies are reported: modifying ligands for stronger interaction with oxide surfaces, mixing ligands, and pre‐depositing an “anchoring ligand” to the support before loading the metal‐ligand catalyst. Each of these is successful in enhancing Pt recyclability. Particularly, two Pt‐phenanthroline catalysts exhibit excellent reusability for multiple batch reaction cycles, due to high stability of the active Pt species. Addressing the active site leaching problem significantly enhances the utility of ligand‐coordinated supported metal catalysts as highly stable and selective catalysts for solution‐phase reactions.

Chen, Linxiao↗

An unusual Co–S bond links B 12 chaperones in an interprotein complex

Chaperones in trafficking pathways ensure specificity of transition metal loading and protection against adventitious side reactions. In B 12 , an essential cofactor for humans, a cobalt ion is coordinated to a >1.3 kDa tetrapyrrolic scaffold, posing logistical challenges for its translocation. In this study, we report the 3.4 Å crystal structure of the human MMACHC and MMADHC B 12 chaperones, tethered via a rarely seen covalent cobalt–sulfur bond. B 12 is bound in the base-off state to MMACHC, with Cys-261 on MMADHC serving as the upper axial ligand; the lower-axial position is vacant. The propensity of thiolato-cobalamin derivatives bound to MMACHC to undergo spontaneous decomposition via general acid catalysis or reduction/oxidation chemistry is averted in the interprotein complex with MMADHC. An exposed face in the complex suggests an exit route for B 12 . No known clinical variants localize to the interprotein interface, consistent with the cobalt–sulfur bond being key to forming the high-affinity complex.

Science & Technology - Other Topics↗

A Cooperative Game Theory-based Approach to Under-frequency Load Shedding Control

This paper proposes a cooperative game theory-based under-frequency load shedding (UFLS) approach for frequency stability and control in power systems. UFLS is a crucial factor for frequency stability and control especially in power grids with high penetration of renewable energy sources and restructured power systems. Conventional UFLS methods, most of which are off-line, usually shed fixed amounts of predetermined loads based on a predetermined schedule which can lead to over or under curtailment of load. This paper presents a co-operative game theory-based two-stage strategy to effectively and precisely determine locations and amounts of loads to be shed for UFLS control. In the first stage, the total amount of loads to be shed, also referred to as deficit in generation or the disturbance power, is computed using the initial rate of change of frequency (ROCOF) referred to the equivalent inertial center. In the second stage, the Shapley value, one of the solution concepts of cooperative game theory, is used to determine load shedding amounts and locations. The proposed method is implemented on the reduced 9-bus 3-machine Western Electricity Coordinating Council (WECC) system and simulated on Real-time Digital Simulators (RTDS). The results show that the proposed UFLS approach can effectively return the system to normal state after disturbances.

42 ENGINEERING↗

Electrospun Ti–Zr Oxide Heterostructures Enable Strongly Anchored Ultralow-Ir Anodes for Durable Acidic Oxygen Evolution

Proton-exchange-membrane water electrolysis (PEMWE) requires acidic oxygen-evolution-reaction (OER) anodes that combine high activity, high durability, and low Ir loading. Here, we report a Ti-Zr composite electrospun oxide (ESO) nanorod support that enables ultralow-Ir anodes for high-performance PEMWE. Zr-containing Ti oxide heterostructures stabilize anatase-rich TiO2, tune the local oxygen-coordination environment, and strengthen interfacial anchoring of IrOx under acidic anodic conditions. The electrospun nanorod network further creates an open, mechanically coherent catalyst layer that improves Ir utilization, ionomer penetration, and mass transport. At an anode loading of 0.2 mgIr cm-2, the optimized Ir/TiZr20-ESO anode delivers a PEMWE mass activity of 0.99 A mgIr-1 at 1.45 V, 28.3 and 43.0 times higher than commercial Ir black and commercial IrO2/TiO2, respectively. The same anode reaches 3.0 and 4.0 A cm-2 at 1.75 and 1.83 V, respectively, and sustains 2000 h operation at 2.0 A cm-2. Also, accelerated stress tests up to 525 hours over 31,500 cycles confirm promising long-term durability, with an insignificant performance decay of 0.4 μV per cycle. Density functional theory indicates that the Ti-Zr oxide heterostructure suppresses Ti demetallation and strengthens IrO2 interfacial binding, rationalizing the improved high-current-density stability.

25 ENERGY STORAGE↗

Rates of levoglucosanol hydrogenolysis over Brønsted and Lewis acid sites on platinum silica-alumina catalysts synthesized by atomic layer deposition

Nanoscale coatings of AlO x were deposited onto SiO 2 using atomic layer deposition (ALD) to synthesize amorphous silica-alumina (SiAl) catalysts, and these catalysts were investigated for levoglucosanol (Lgol) hydrogenolysis. With decreasing Al 2 O 3 loading, the ratio of Brønsted to Lewis acid sites, measured by NH 3 -TPD and pyridine-FTIR, systematically increases, while the Al coordination, measured by solid state 27 Al NMR, decreases. These structural changes correspond to an increasing mass-normalized rate of Lgol hydrogenolysis. We model the mass-normalized reaction rate as the sum of independent contributions from Brønsted and Lewis sites, showing that Brønsted acid sites on ALD-AlO x /SiO 2 catalysts have a 6-times higher turnover frequency (TOF) than Lewis acid sites on these catalysts. Additionally, Lewis acid sites on ALD-AlO x /SiO 2 catalysts (potentially related to Al(V) species) have a 4-times higher TOF than Lewis acid sites on bulk γ-Al 2 O 3 . The overall mass-normalized reactivity of ALD-AlO x /SiO 2 catalysts is due to Lewis acid sites at the highest Al 2 O 3 loading, while it is predominantly due to Brønsted acid sites at the lowest Al 2 O 3 loadings. In conclusion, this work provides a new approach to synthesize amorphous SiAls with tunable Brønsted/Lewis acid site ratio and reveals differences in the reactivity of Brønsted and Lewis acid sites on these materials.

36 MATERIALS SCIENCE↗

Robust Scheduling of Networked Microgrids for Economics and Resilience Improvement

The benefits of networked microgrids in terms of economics and resilience are investigated and validated in this work. Considering the stochastic unintentional islanding conditions and conventional forecast errors of both renewable generation and loads, a two-stage adaptive robust optimization is proposed to minimize the total operating cost of networked microgrids in the worst scenario of the modeled uncertainties. By coordinating the dispatch of distributed energy resources (DERs) and responsive demand among networked microgrids, the total operating cost is minimized, which includes the start-up and shut-down cost of distributed generators (DGs), the operation and maintenance (O&M) cost of DGs, the cost of buying/selling power from/to the utility grid, the degradation cost of energy storage systems (ESSs), and the cost associated with load shedding. The proposed optimization is solved with the column and constraint generation (C&CG) algorithm. The results of case studies demonstrate the advantages of networked microgrids over independent microgrids in terms of reducing total operating cost and improving the resilience of power supply.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Distribution System Operator with Transactive (DSO+T) Study

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗