Search NASA⌕ Search

SEARCH · Search NASA

Results for “Log data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Assessing the potential of composite confining systems for secure and long-term CO 2 retention in geosequestration

A potential geologic target for CO 2 storage should ensure secure containment of injected CO 2 . Traditionally, this objective has been achieved by targeting reservoirs with overlying seals-regionally extensive, low permeability units that have been proven capable of retaining buoyant fluid accumulations over geologic time. However, considering that the amount of CO 2 is limited by a decadal injection period, vertical migration of CO 2 can be effectively halted by a composite system of discontinuous shale/silt/mudstone barriers in bedded sedimentary rocks. Here, we studied the impact of depositional architectures in a composite confining system on CO 2 migration and confinement at reservoir scale. We stochastically generated lithologically heterogeneous reservoir models containing discontinuous barriers consistent with statistical distributions of net-sand-to-gross-shale ratio (NTG) and horizontal correlation lengths derived from well log data and observations of producing hydrocarbon fields in Southern Louisiana. We then performed an extensive suite of reservoir simulations of CO 2 injection and post-injection to evaluate the sensitivity of CO 2 plume migration and pressure response of the composite system to a series of geologic and fluid parameters including the lateral continuity of barriers, NTG, permeability anisotropy within the sand body, and capillary pressure contrast between the sand and shale facies. The results indicate that lateral continuity of barriers and NTG are the dominant controls on CO 2 plume geometry and pressure build-up in the reservoir, while the impact of NTG is particularly pronounced. The significance of intraformational barriers becomes apparent as they facilitate the local capillary trapping of CO 2 . Those barriers improve the pore space occupancy by promoting a more dispersed shape of the plume and ultimately retard the buoyancy-driven upward migration of the plume post injection.

58 GEOSCIENCES↗

Direct sunlight facility for testing and research in HCPV

A facility for testing different components for HCPV application has been developed in the framework of 'Fotovoltaico ad Alta Efficienza' (FAE) project funded by the Sicilian Regional Authority (PO FESR Sicilia 2007/2013 4.1.1.1). The testing facility is equipped with an heliostat providing a wide solar beam inside the lab, an optical bench for mounting and aligning the HCPV components, electronic equipments to characterize the I-V curves of multijunction cells operated up to 2000 suns, a system to circulate a fluid in the heat sink at controlled temperature and flow-rate, a data logging system with sensors to measure temperatures in several locations and fluid pressures at the inlet and outlet of the heat sink, and a climatic chamber with large test volume to test assembled HCPV modules.

14 SOLAR ENERGY↗

A statistical method for estimating wood thermal diffusivity and probe geometry using in situ heat response curves from sap flow measurements

The heat pulse method is widely used to measure water flux through plants; it works by inferring the velocity of water through a porous medium from the speed at which a heat pulse is propagated through the system. No systematic, non-destructive calibration procedure exists to determine the site-specific parameters necessary for calculating sap velocity, e.g., wood thermal diffusivity and probe spacing. Such parameter calibration is crucial to obtain the correct transpiration flux density from the sap flow measurements at the plant scale; and consequently, to up-scale tree-level water fluxes to canopy and landscape scales. The purpose of this study is to present a statistical framework for estimating the wood thermal diffusivity and probe spacing simutaneously from in-situ heat response curves collected by the implanted probes of a heat ratio apparatus. Conditioned on the time traces of wood temperature following a heat pulse, the parameters are inferred using a Bayesian inversion technique, based on the Markov chain Monte Carlo sampling method. The primary advantage of the proposed methodology is that it does not require known probe spacing or any further intrusive sampling of sapwood. The Bayesian framework also enables direct quantification of uncertainty in estimated sap flow velocity. Experiments using synthetic data show that repeated tests using the same apparatus are essential to obtain reliable and accurate solutions. When applied to field conditions, these tests are conducted during different seasons and automated using the existing data logging system. The seasonality of wood thermal diffusivity is obtained as a by-product of the parameter estimation process, and it is shown to be affected by both moisture content and temperature. Empirical factors are often introduced to account for the influence of non-ideal probe geometry on the estimation of heat pulse velocity, and they are estimated in this study as well. The proposed methodology can be applied for the calibration of existing heat ratio sap flow systems at other sites. It is especially useful when an alternative transpiration calibration device, such as a lysimeter, is not available.

Bayesian inversion↗

Setting the threshold for high throughput detectors: A mathematical approach for ensembles of dynamic, heterogeneous, probabilistic anomaly detectors

Cyber operations now manage a high volume of heterogeneous log data. Anomaly Detection (AD) in such operations involves multiple (e.g., per IP, per data type) ensembles of detectors modeling heterogeneous characteristics (e.g., rate, size, type) often with adaptive online models producing alerts in near real time. Because of the high data volume, setting the threshold for each detector in such a system is an essential yet underdeveloped configuration issue that, if slightly mistuned, can leave the system useless, either producing a myriad of alerts (and flooding downstream systems) or giving none. In this work, we build on the foundations of Ferragut et al. to provide a set of rigorous results for understanding the relationship between threshold values and alert quantities for probabilistic detectors. This informs an algorithm for setting the threshold of multiple, heterogeneous, possibly dynamic detectors completely a priori, in principle. Indeed, if the underlying distribution of the incoming data is known, the algorithm provides provably manageable thresholds. If the distribution is unknown (poorly estimated), our analysis gives insight into how the model distribution differs from the actual distribution, indicating refitting is necessary. We provide empirical experiments, regulating the alert rate of a system with ≈2,500 adaptive detectors scoring over 1.5M events in 5 hours of timestamps. Further, we demonstrate on real network data and detection framework of Harshaw et al. the alternative case, demonstrating that the inability to regulate alerts indicates how the detection model is not a good fit to the data.

Bridges, Robert↗

Applying Graph Analytics to Understand Compute Core Usage and Publication Trends in a Petascale Supercomputing Facility

The Oak Ridge Leadership Computing Facility (OLCF) runs Titan, the No. 4 supercomputer in the world, to deliver over four billion compute core hours every year to several scientific domains, in their pursuit of leadership science. In this paper, we analyze four years worth of heterogeneous log data sources from the OLCF resource fabric, capturing metadata on entities such as users (2,546), scientific project allocations (674), jobs (1,352,402) and publications (1,146), to derive insights into the trends in core hour usage and publications, across 35 science domains. We have constructed a scalable graph to represent the OLCF entities and apply rich graph analytics for our analysis. Based on this, we have analyzed the metadata across five dimensions, namely (1) quantitative analysis of Titan system usage, (2) quantitative analysis of OLCF publications, (3) correlation analysis between system usage and publications, (4) text analysis to derive OLCF research trends, and (5) utilization of graph mining for association analysis. To the best of our knowledge, our work is the first of its kind to apply graph- based big data techniques to provide comprehensive insights on an HPC center's core hour usage and users' publication trends. Our results provide valuable details into an HPC center's core allocation program, measuring the productivity of scientific domains, the interplay between core usage and research output, accelerating collaboration, and in predicting new connections between resource entities.

Lee, Sangkeun (Matt)↗

Radiation testing of 2.4 micron wavelength extended InGaAs photodiodes for 100 MeV/n carbon ions

We have successfully tested simultaneously 2.4 Micron Wavelength, Extended InGaAs Photodiodes having diameters of 20, 30, 40, 50, 100, 150, 200, 250, and 290 Micron, coupled with a Single Mode Fiber using 100 MeV/n Carbon (C) Ions up to a cumulative dose of ~40 krad. During irradiation, the devices were maintained at dry ice temperature, reverse biased at 100 mV, and their leakage current was continuously monitored in-situ during the run. After the exposure was completed, all nine devices were monitored for any change in their leakage current at 100 mV and room temperature for several weeks to monitor any annealing effects that may occur. Nine Photodiodes with the above varying diameters were radiated with 100 MeV/n Carbon Ions with a fluence of 10 6 , 10 7 , 10 8 , 10 9 , and 10 10 ions/cm 2 at each fluence level. At 100 MeV/n the Linear Energy Transfer (LET) of Carbon Ion is ~0.156 MeV-cm 2 /mg in Extended InGaAs, which is an order magnitude more than Proton (H) and Helium (He) Ions of 100 MeV/n energy. Thus, significant displacement damage is anticipated in the Extended InGaAs Photodiode with 100 MeV/n Carbon Ions with a total fluence of 1 × 1010 ions/cm 2 . Pre- and Post- radiation results were also measured for: (1) Leakage Current Vs. Voltage for the Extended InGaAs Photodiodes; (2) Responsivity (Quantum Efficiency) in A/W for Photodiodes; and (3) Bandwidth of the Photodiodes. All devices were found to be fully functional at the normal operating conditions and at both dry ice and room temperature. The leakage current increased up to a factor of ~2X at lower bias of 100 mV at the highest fluence of 10 10 ions/cm 2 , but not significantly at higher bias of 2 V. Finally, we did not observe any post radiation annealing effect for leakage current at room temperature and 100 mV bias for any of the devices after several weeks of data logging.

2.4 micron wavelength↗

SU-E-T-400: Evaluation of Shielding and Activation at Two Pencil Beam Scanning Proton Facilities

Purpose: To verify acceptably low dose levels around two newly constructed identical pencil beam scanning proton therapy facilities and to evaluate accuracy of pre-construction shielding calculations. Methods: Dose measurements were taken at select points of interest using a WENDI-2 style wide-energy neutron detector. Measurements were compared to pre-construction shielding calculations. Radiation badges with neutron dose measurement capabilities were worn by personnel and also placed at points throughout the facilities. Seven neutron and gamma detectors were permanently installed throughout the facility, continuously logging data. Potential activation hazards have also been investigated. Dose rates near water tanks immediately after prolonged irradiation have been measured. Equipment inside the treatment room and accelerator vault has been surveyed and/or wipe tested. Air filters from air handling units, sticky mats placed outside of the accelerator vault, and water samples from the magnet cooling water loops have also been tested. Results: All radiation badges have been returned with readings below the reporting minimum. Measurements of mats, air filters, cooling water, wipe tests and surveys of equipment that has not been placed in the beam have all come back at background levels. All survey measurements show the analytical shielding calculations to be conservative by at least a factor of 2. No anomalous events have been identified by the building radiation monitoring system. Measurements of dose rates close to scanning water tanks have shown dose rates of approximately 10 mrem/hr with a half-life less than 5 minutes. Measurements around the accelerator show some areas with dose rates slightly higher than 10 mrem/hr. Conclusion: The shielding design is shown to be adequate. Measured dose rates are below those predicted by shielding calculations. Activation hazards are minimal except in certain very well defined areas within the accelerator vault and for objects placed directly in the path of the beam.

60 APPLIED LIFE SCIENCES↗

A Parallel Stochastic Framework for Reservoir Characterization and History Matching

The spatial distribution of parameters that characterize the subsurface is never known to any reasonable level of accuracy required to solve the governing PDEs of multiphase flow or species transport through porous media. This paper presents a numerically cheap, yet efficient, accurate and parallel framework to estimate reservoir parameters, for example, medium permeability, using sensor information from measurements of the solution variables such as phase pressures, phase concentrations, fluxes, and seismic and well log data. Numerical results are presented to demonstrate the method.

Thomas, Sunil G.↗

Replay-Stream

For testing and demonstration purposes, it is often necessary to replay saved network and log data. This library facilitates replaying these saved data streams. This module will take in a stream of JSON strings, read their specified timestamp field, and output according to the given criteria. This can include restricting output to a certain time range, and/or outputting the items with some delay based on their timestamp.

Goodall, John↗

Well Log ETL tool

This is an executable python script which offers two different conversions for well log data: 1) Conversion from a BoreholeLASLogData.xls model to a LAS version 2.0 formatted XML file. 2) Conversion from a LAS 2.0 formatted XML file to an entry in the WellLog Content Model. Example templates for BoreholeLASLogData.xls and WellLogsTemplate.xls can be found in the package after download.

Good, Jessica↗

Sight Version 0.1

Enables applications to emit log information into an output file and produced a structured visual summary of the log data, as well as various statistical analyses of it. This makes it easier for developers to understand the behavior of their applications.

Bronevetsky, G.↗

BACnet Client [SWR-13-26]

The BACnet Client is designed to gather data from building control systems through the BACnet protocol and send to various destinations for data logging and collection.

Long, Nicholas↗

Anno v1

The Anno log annotation system provides tools for creating and querying annotations to supercomputing log data.

Greiner, AnnetteM↗

lumicap v0.1

Automated HDR luminance imaging system designed for daylighting research and building science. It controls a fisheye-lens camera to capture time-lapse bracket sequences, merges them into calibrated HDR images, and runs a full post-processing pipeline — all unattended. Features: - Scheduled LDR bracket capture via gphoto2 - HDR merging with vignetting, ND filter, and fisheye projection corrections - Illuminance and luminance meter integration (Konica Minolta T-10A, LS-100/150) - Daylight glare probability (DGP) and solar position computation - Automated false-color rendering, JPEG thumbnails, and daily time-lapse video - CSV data logging per timestep Uses: - Long-term monitoring of daylight conditions in buildings - Glare analysis for occupant comfort research - Solar irradiance and sky luminance studies Advantages: - End-to-end automation — capture, calibration, analysis, and archiving run without manual intervention - Built on the proven Radiance toolchain, ensuring photometrically accurate HDR output - Hardware-agnostic meter support via serial auto-detection - Lightweight — no GUI overhead, deployable on a headless Raspberry Pi or similar embedded system

Wang, Taoning [Lawrence Berkeley National Laborato↗

Pore characterization of the Marcellus Shale by nitrogen adsorption and prediction of its gas storage capacity

In a shale gas reservoir, pore characterization is an important factor used to determine gas storage capacity. However, the nanometer (nm)-scale pore system in shale is difficult to explore by traditional optical, scanning electron microscopy, or even nuclear magnetic resonance well logging. We have investigated the pore structure and storage capacity of the Marcellus Shale through integration of petrophysical analysis from laboratory and well-logging data and nitrogen adsorption. The isotherm of Marcellus Shale is a composite isotherm, which has features of type I, type II, and type IV isotherms with type H4 of the hysteresis loop, suggesting slit-like pores developed in the Marcellus Shale. Quantitative analysis of pore volumes from the nitrogen adsorption indicates that density porosity may be more properly used to approximate the shale porosity and estimate the shale gas volume. In addition, the specific surface area, micropore, and mesopore volumes have a positive relationship with the kerogen volume and total organic content (TOC). By using the Langmuir and Brunauer-Emmet-Teller models, the simulated result indicates that the higher adsorbed quantity of the Marcellus Shale could be the result of the increase of micropore volume contributed, by the increase of kerogen or TOC content. The proposed equations rapidly compute TOC, a key parameter to predict gas storage capacity in overmature shale such as the Marcellus Shale.

Geochemistry & Geophysics↗

Seismically Detecting Nuclear Reactor Operations Using a Power Spectral Density (PSD) Misfit Detector

To explore the ability to indirectly detect and attribute various operations conducted at a nuclear reactor using waveform data, we investigated the seismic signals recorded near the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory in Oak Ridge, Tennessee. Specifically, we processed seismic data collected from a single seismoacoustic station, WACO, near the HFIR facility, and employed a power spectral density misfit detector to identify signals of interest and associate the detections with operational events. Initial results suggest that this method provides a promising means of regularly detecting at least 19 unique operations. Furthermore, with additional station deployment and more comprehensive data logs, we anticipate that future analysis will offer an additional means to seismically monitor nuclear reactors (such as HFIR) health and performance more accurately.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Southeast-PA-Diabase

Computed tomography and high-resolution core log data associated with the technical report "Computed Tomography Scanning and Geophysical Measurements of the Southeastern Pennsylvania Triassic Diabase Core" Schmitt, R.; Paronish, T.; Crandall, D.; Moore, J.; Neubaum, J.; Andrews, G. "Computed Tomography Scanning and Geophysical Measurements of the Southeastern Pennsylvania Triassic Diabase Core; DOE.NETL-2021.2843; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2021; p 104

Computed Tomography↗

Coldstream 1MH Well

Computed tomography scans and core log data obtained at the National Energy Technology Laboratory. Complimentary to 'Computed Tomography Scanning and Geophysical Measurements of Core from the Coldstream 1MH Well" Technical Report Series, 2018

CT Scans↗