Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

New opportunities at the next-generation neutrino experiments I: BSM neutrino physics and dark matter

The combination of the high intensity proton beam facilities and massive detectors for precision measurements of neutrino oscillation parameters including the charge-parity violating (CPV) phase will open the door to help make beyond the standard model (BSM) physics reachable even in low energy regimes in the accelerator-based experiments. Large-mass detectors with highly precise tracking and energy measurements, excellent timing resolution, and low energy thresholds will enable the searches for BSM phenomena from cosmogenic origin, as well. Therefore, it is also conceivable that BSM topics in the next-generation neutrino experiments could be the dominant physics topics in the foreseeable future, as the precision of the neutrino oscillation parameter and CPV measurements continue to improve. This paper reviews the current landscape of BSM theory in neutrino experiments in two selected areas of the BSM topics-dark matter and neutrino related BSM-and summarizes the current results from existing neutrino experiments to set benchmarks for both theory and experiment. This paper then provides a review of upcoming neutrino experiments throughout the next 10 to 15 year time scale and their capabilities to set the foundation for potential reach in BSM physics in the two aforementioned themes. An important outcome of this paper is to ensure theoretical and simulation tools exist to carry out studies of these new areas of physics, from the first day of the experiments, such as Deep Underground Neutrino Experiment in the U.S. and Hyper-Kamiokande Experiment in Japan.

dark sector↗

Description of di-hadron saturation signals within a universal nuclear parton distribution function approach

Di-hadron and di-jet correlation measurements in proton-nucleus (𝑝+𝐴) and electron-nucleus collisions are widely motivated as sensitive probes of novel, nonlinear quantum chromodynamices saturation dynamics in hadrons, which are particularly accessible in the dense nuclear environment at low values of Bjorken-𝑥 (𝑥 A ). Current measurements at the BNL Relativistic Heavy Ion Collider (RHIC) and the CERN Large Hadron Collider (LHC) observe a significant suppression in the per-trigger yield at forward rapidities compared to that in proton-proton collisions, nominally consistent with the “mono-jet” production expected in a saturation scenario. However, the width of the azimuthal correlation remains unmodified, in contradiction to the qualitative expectations from this physics picture. I investigate whether the construction of these observables leaves them sensitive to effects from simple nuclear shadowing as captured by, for example, universal nuclear parton distribution function (nPDF) analyses. I find that modern nPDF sets, informed by recent precision measurements sensitive to the shadowing of low-𝑥 A gluon densities in LHC and other data, can describe all or the majority of the di-hadron/jet suppression effects in 𝑝+𝐴 data at both RHIC and the LHC, while giving a natural explanation for why the azimuthal correlation width is unmodified. Notably, this is achieved via a (𝑥 A ,𝑄 2 )-differential suppression of overall cross sections only, without requiring additional physics dynamics which alter the interevent correlations.

Jets & heavy flavor physics↗

Efficient phase-factor evaluation in quantum signal processing

Quantum signal processing (QSP) is a powerful quantum algorithm to exactly implement matrix polynomials on quantum computers. Asymptotic analysis of quantum algorithms based on QSP has shown that asymptotically optimal results can in principle be obtained for a range of tasks, such as Hamiltonian simulation and the quantum linear system problem. A further benefit of QSP is that it uses a minimal number of ancilla qubits, which facilitates its implementation on near-to-intermediate term quantum architectures. However, there is so far no classically stable algorithm allowing computation of the phase factors that are needed to build QSP circuits. Existing methods require the use of variable precision arithmetic and can only be applied to polynomials of a relatively low degree. We present here an optimization-based method that can accurately compute the phase factors using standard double precision arithmetic operations. We demonstrate the performance of this approach with applications to Hamiltonian simulation, eigenvalue filtering, and quantum linear system problems. Furthermore, our numerical results show that the optimization algorithm can find phase factors to accurately approximate polynomials of a degree larger than 10000 with errors below 10 -12 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

Photonic circuits for laser stabilization with integrated ultra-high Q and Brillouin laser resonators

The integration of stabilized lasers, sources that generate spectrally pure light, will provide compact, low-cost solutions for applications including quantum information sciences, precision navigation and timing, metrology, and high-capacity fiber communications. We report a significant advancement in this field, demonstrating stabilization of an integrated waveguide Brillouin laser to an integrated waveguide reference cavity, where both resonators are fabricated using the same CMOS-compatible integration platform. We demonstrate reduction of the free running Brillouin laser linewidth to a 292 Hz integral linewidth and carrier stabilization to a 4.9 × 10 –13 fractional frequency at 8 ms reaching the cavity-intrinsic thermorefractive noise limit for frequencies down to 80 Hz. We achieve this level of performance using a pair of 56.4 x 10 6 quality factor Si 3 N 4 waveguide ring-resonators that reduce the high-frequency noise by the nonlinear Brillouin process and the low-frequency noise by Pound–Drever–Hall locking to the ultra-low loss resonator. These results represent an important step toward integrated stabilized lasers with reduced sensitivity to environmental disturbances for atomic, molecular, and optical physics (AMO), quantum information processing and sensing, and other precision scientific, sensing, and communications applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sculpting the Plasmonic Responses of Nanoparticles by Directed Electron Beam Irradiation

Spatial confinement of matter in functional nanostructures has propelled these systems to the forefront of nanoscience, both as a playground for exotic physics and quantum phenomena and in multiple applications including plasmonics, optoelectronics, and sensing. In parallel, the emergence of monochromated electron energy loss spectroscopy (EELS) has enabled exploration of local nanoplasmonic functionalities within single nanoparticles and the collective response of nanoparticle assemblies, providing deep insight into associated mechanisms. However, modern synthesis processes for plasmonic nanostructures are often limited in the types of accessible geometry, and materials and are limited to spatial precisions on the order of tens of nm, precluding the direct exploration of critical aspects of the structure-property relationships. Here, the atomic-sized probe of the scanning transmission electron microscope is used to perform precise sculpting and design nanoparticle configurations. Using low-loss EELS, dynamic analyses of the evolution of the plasmonic response are provided. It is shown that within self-assembled systems of nanoparticles, individual nanoparticles can be selectively removed, reshaped, or patterned with nanometer-level resolution, effectively modifying the plasmonic response in both space and energy. This process significantly increases the scope for design possibilities and presents opportunities for unique structure development, which are ultimately the key for nanophotonic design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of High-Temperature Corrosion of Zirconium Alloys Using the eXtended Finite Element Method (X-FEM)

Oxidation modeling in modern nuclear fuel performance codes is currently limited by the lack of coupling with mechanics, thus preventing proper description of how high-temperature oxidation impacts mechanical properties. This is mostly due to the fact that the finite difference formalism adopted in corrosion models is incompatible with the direct coupling with mechanics in the finite element modeling employed in modern nuclear fuel performance codes. In this study, a physically based zirconium alloy corrosion model called the Coupled-Current Charge Compensation (C4) model, which was initially developed for operating temperature conditions, has been updated to include high-temperature corrosion in order to provide additional critical information (e.g., oxygen concentration profile) under loss-of-coolant accident (LOCA) conditions—information lacking in existing empirical models. The C4 model was implemented in the MOOSE finite-element framework developed at Idaho National Laboratory, enabling it to be used in the BISON nuclear fuel performance code based on the MOOSE framework. To precisely track the different interfaces at a relatively low computational cost, the eXtended Finite Element Method (X-FEM) was applied in MOOSE. The model’s results were compared to those of existing empirical models as well as metallographic analysis of high-temperature oxidized Zircaloy-4 coupons. Oxygen diffusivities in the a and ß phases resulting from this comparison closely agree with those found in the literature. The C4 model implemented with X-FEM in MOOSE now has the capability to accurately predict oxide, oxygen-stabilized a, and prior ß phase layer growth kinetics under isothermal exposure at high temperature (1000–1500°C). Furthermore, in contrast with the empirical models, the C4 model accounts for the finite thickness of the fuel cladding. It can predict the oxygen concentration profile evolution through the whole cladding, enabling evaluation of the remaining ductile thickness—a crucial variable for modeling the mechanical behavior of the fuel cladding under LOCA. Furthermore, this implementation allows direct coupling with mechanics, at a low computing cost, using finite-element-based nuclear fuel performance codes such as BISON.

36 MATERIALS SCIENCE↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the nuclear modification factor for muons from charm and bottom hadrons in Pb+Pb collisions at 5.02 TeV with the ATLAS detector

Heavy-flavour hadron production provides information about the transport properties and microscopic structure of the quark–gluon plasma created in ultra-relativistic heavy-ion collisions. A measurement of the muons from semileptonic decays of charm and bottom hadrons produced in Pb+Pb and pp collisions at a nucleon–nucleon centre-of-mass energy of 5.02 TeV with the ATLAS detector at the Large Hadron Collider is presented. The Pb+Pb data were collected in 2015 and 2018 with sampled integrated luminosities of 208 μb –1 and 38 μb –1 , respectively, and pp data with a sampled integrated luminosity of 1.17 pb –1 were collected in 2017. Muons from heavy-flavour semileptonic decays are separated from the light-flavour hadronic background using the momentum imbalance between the inner detector and muon spectrometer measurements, and muons originating from charm and bottom decays are further separated via the muon track's transverse impact parameter. Differential yields in Pb+Pb collisions and differential cross sections in pp collisions for such muons are measured as a function of muon transverse momentum from 4 GeV to 30 GeV in the absolute pseudorapidity interval |n| < 2. Nuclear modification factors for charm and bottom muons are presented as a function of muon transverse momentum in intervals of Pb+Pb collision centrality. The bottom muon results are the most precise measurement of b quark nuclear modification at low transverse momentum where reconstruction of B hadrons is challenging. The measured nuclear modification factors quantify a significant suppression of the yields of muons from decays of charm and bottom hadrons, with stronger effects for muons from charm hadron decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantification of Inactive Lithium and Solid–Electrolyte Interphase Species on Graphite Electrodes after Fast Charging

Rapid charging of Li-ion batteries is limited by lithium plating on graphite anodes, whereby Li+ ions are reduced to Li metal on the graphite particle surface instead of inserting between graphitic layers, which directly contributes to cell capacity loss because of the low reversibility of the Li plating/stripping process. Furthermore, precisely identifying the onset and amount of Li plating is therefore vital in order to remedy these issues. We demonstrate a titration technique with a detection limit of 20 nmol (5 × 10 –4 mAh) of Li that can be used to quantify inactive Li that remains on the graphite electrode after fast charging. The titration is extended to quantify the total amount of solid carbonate species and lithium acetylide (Li 2 C 2 ) within the solid–electrolyte interphase (SEI), and electrochemical modeling is used to determine the Li plating exchange current density (10 A/m 2 ) and stripping efficiency (65%) of plated Li metal on graphite. These techniques provide a highly accurate measure of the onset of Li plating and quantitative insight into graphite SEI evolution during fast charging.

25 ENERGY STORAGE↗

Experimental validation of a collision-radiation dataset for molecular hydrogen in plasmas

Quantitative spectroscopy of molecular hydrogen has generated substantial demand, leading to the accumulation of diverse elementary process data encompassing radiative transitions, electron-impact transitions, predissociations, and quenching. However, their rates currently available are still sparse, and there are inconsistencies among those proposed by different authors. In this study, we demonstrate an experimental validation of such a molecular dataset by composing a collisional-radiative model (CRM) for molecular hydrogen and comparing experimentally obtained vibronic populations across multiple levels. From the population kinetics of molecular hydrogen, the importance of each elementary process in various parameter space is studied. In low-density plasmas (electron density ne≲1017 m−3) the excitation rates from the ground states and radiative decay rates, both of which have been reported previously, determine the excited state population. The inconsistency in the excitation rates affects the population distribution the most significantly in this parameter space. However, in higher density plasmas (ne≳1018 m−3), the excitation rates from excited states become important, which have never been reported in the literature, and may need to be approximated in some way. In order to validate these molecular datasets and approximated rates, we carried out experimental observations for two different hydrogen plasmas; a low-density radio frequency heated plasma (ne≈1016 m−3) and the Large Helical Device (LHD) divertor plasma (ne≳1018 m−3). The visible emission lines from EF1Σg+, HH¯1Σg+, D1Πu±, GK1Σg+, I1Πg±, J1Δg±, h3Σg+, e3Σu+, d3Πu±,g3Σg+, i3Πg±, and j3Δg± states were observed simultaneously and their population distributions were obtained from their intensities. We compared the observed population distributions with the CRM prediction, in particular the CRM with the rates compiled by Janev et al., Miles et al., and those calculated with the molecular convergent close-coupling (MCCC) method. The MCCC prediction gives the best agreement with the experiment, particularly for the emission from the low-density plasma. However, the population distribution in the LHD divertor shows a worse agreement with the CRM than those from low-density plasma, indicating the necessity of the precise excitation rates from excited states. We also found that the rates for the electron attachment is inconsistent with experimental results. This requires further investigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The pathfinder X-Ray axion telescope for the International Axion Observatory (IAXO) and axion searches at the CERN Axion Solar Telescope (CAST)

The axion, a hypothetical pseudo-scalar particle proposed by Peccei and Quinn to resolve the strong CP problem in quantum chromodynamics, remains one of the most compelling dark matter candidates. Axions and Axion-Like Particles (ALPs) are characterized by a broad and largely unconstrained parameter space in mass and coupling strength, motivating extensive experimental searches. The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to achieve over an order of magnitude improvement in sensitivity to the axion-photon coupling constant gaγ relative to previous experiments such as the CERN Axion Solar Telescope (CAST). IAXO will employ large-scale superconducting magnets, precision x-ray optics, and ultra-low-background detectors to search for solar axions produced primarily via the Primakoff effect. This work presents the design and performance of the IAXO pathfinder x-ray optic, a technological demonstrator that validated the optical concepts for IAXO through axion searches at CAST. Comprehensive ray-tracing simulations and experimental measurements were conducted to assess the optic's effective area, detection efficiency, and background suppression capabilities. Deployed at CAST in conjunction with Micromegas and GridPix detectors, the Pathfinder demonstrated record-setting sensitivity to both gaγ and the axion-electron coupling gae, establishing the most stringent laboratory constraints on solar axions to date. These results confirm the viability of the IAXO optical design and detector concept, providing a critical technological benchmark that informs the ongoing development of the BabyIAXO and full-scale IAXO telescopes.

47 OTHER INSTRUMENTATION↗

Fundamental physics with ESPRESSO: a new determination of the D/H ratio towards PKS1937-101

ABSTRACT Primordial abundances of light elements are sensitive to the physics of the early Universe and can directly constrain cosmological quantities, such as the baryon-to-photon ratio $\eta _{10}$, the baryon density, and the number of neutrino families. Deuterium is especially suited for these studies: its primordial abundance is sensitive and monotonically dependent on $\eta _{10}$, allowing an independent measurement of the cosmic baryon density that can be compared, for instance, against the Planck satellite data. The primordial deuterium abundance can be measured in high H i column density absorption systems towards distant quasars. We report here a new measurement, based on high-resolution ESPRESSO data, of the primordial D i abundance of a system at redshift $z \sim 3.572$, towards PKS1937-101. Using only ESPRESSO data, we find a D /H ratio of $2.638\pm 10^{-5}$, while including the available UVES data improves the precision, leading to a ratio of $2.608 \pm 10^{-5}$. The results of this analysis agree with those of the most precise existing measurements. We find that the relatively low column density of this system ($\log {N_{\rm H_I}/ {\rm cm}^{-2}}\sim 18$) introduces modelling uncertainties, which become the main contributor to the error budget.

Guarneri, Francesco (ORCID:0000000347409762)↗

Improved Limit on Tensor Currents in the Weak Interaction from Li 8 β Decay

Here, the electroweak interaction in the standard model is described by a pure vector-axial-vector structure, though any Lorentz-invariant component could contribute. In this Letter, we present the most precise measurement of tensor currents in the low-energy regime by examining the $β-\bar{ν}$ correlation of trapped 8 Li ions with the Beta-decay Paul Trap. We find $a_{β\barν}$ = - 0.3325 ± 0.0013 stat ± 0.0019 syst at 1σ for the case of coupling to right-handed neutrinos (C T = -C$^{'}_{T}$), which is consistent with the standard model prediction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pion electroproduction measurements in the nucleon resonance region

Here, we report new pion electroproduction measurements in the $\Delta (1232)$ resonance, utilizing the SHMS - HMS magnetic spectrometers of Hall C at Jefferson Lab. The data focus on a region that exhibits a strong and rapidly changing interplay of the mesonic cloud and quark-gluon dynamics in the nucleon. The results are in reasonable agreement with models that employ pion cloud effects and chiral effective field theory calculations, but at the same time they suggest that an improvement is required to the theoretical calculations and provide valuable input that will allow their refinements. The data illustrate the potential of the magnetic spectrometers setup in Hall C towards the study the $\Delta (1232)$ resonance. These first reported results will be followed by a series of measurements in Hall C, that will expand the studies of the $\Delta (1232)$ resonance offering a high precision insight within a wide kinematic range from low to high momentum transfers.

13.60.Fz Transition Form Factors↗

Measurement of the transverse momentum distribution of Drell–Yan lepton pairs in proton–proton collisions at √s=13 TeV with the ATLAS detector

This paper describes precision measurements of the transverse momentum $p_\mathrm {T}^{\ell \ell }$ ($\ell =e,\mu $) and of the angular variable $\phi ^{*}_{\eta }$ distributions of Drell–Yan lepton pairs in a mass range of 66–116 GeV. The analysis uses data from 36.1 fb$^{-1}$ of proton–proton collisions at a centre-of-mass energy of $\sqrt{s}=13\,$TeV collected by the ATLAS experiment at the LHC in 2015 and 2016. Measurements in electron-pair and muon-pair final states are performed in the same fiducial volumes, corrected for detector effects, and combined. Compared to previous measurements in proton–proton collisions at $\sqrt{s}=7$ and $8\,$TeV, these new measurements probe perturbative QCD at a higher centre-of-mass energy with a different composition of initial states. They reach a precision of 0.2$\%$ for the normalized spectra at low values of $p_\mathrm {T}^{\ell \ell }$. The data are compared with different QCD predictions, where it is found that predictions based on resummation approaches can describe the full spectrum within uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Luminosity determination in $pp$ collisions at $\sqrt{s}=13$ TeV using the ATLAS detector at the LHC

The luminosity determination for the ATLAS detector at the LHC during Run 2 is presented, with pp collisions at a centre-of-mass energy $\sqrt{s}$ = 13 TeV. The absolute luminosity scale is determined using van der Meer beam separation scans during dedicated running periods in each year, and extrapolated to the physics data-taking regime using complementary measurements from several luminosity-sensitive detectors. The total uncertainties in the integrated luminosity for each individual year of data taking range from 0.9% to 1.1%, and are partially corre lated between years. After standard data-quality selections, the full Run 2 pp data sample corresponds to an integrated luminosity of 140.1 ± 1.2 fb -1 , i.e. an uncertainty of 0.83%. A dedicated sample of low-pileup data recorded in 2017– 2018 for precision Standard Model physics measurements is analysed separately, and has an integrated luminosity of 338.1 ± 3.1 pb -1 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of event position reconstruction based on diffusion in the NEXT-white detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift dis tance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high and low-energy events. Using point-like energy deposits from 83m Kr calibration electron captures (E ~ 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias < 1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E ≥ 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q ββ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗