Results for “Low threshold detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

188 records · Page 11

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

Here, in this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

47 OTHER INSTRUMENTATION↗

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Impact of composition and symmetry energy on the temperature of quasiprojectiles simulated with antisymmetrized molecular dynamics

The equation of state describes the emergent physical properties of matter. Experimental data is needed to help constrain the equation of state for nuclear matter. These constraints can help distinguish between an “asy-stiff” and an “asy-soft” equation of state, which has astrophysical implications. One path to help constrain the models is to analyze the nuclear caloric curve; some experiments have shown dependence on neutron excess, and may thus be sensitive to the asymmetry. A difference in the caloric curve based on the asymmetry of the reconstructed quasiprojectile (QP) had been observed using 70 Zn on 70 Zn at 35 MeV/nucleon taken with the NIMROD array. Antisymmetrized molecular dynamics calculations were performed for the same system and deexcited with gemini++. Both Gogny (asy-soft) and Gogny-as (asy-stiff) data sets were generated. The particles were then filtered based on detector geometric acceptance and thresholds. From the accepted particles, the excitation energy and temperature were calculated in the same way as for experimental data. Additionally, filter effects on the observed nuclear caloric curves were investigated. A tendency for the asy-stiff nuclear caloric curves to have higher temperatures than their asy-soft counterparts was observed for a number of probes. In addition, some probes may show sensitivity to the reconstructed composition of the QP, but this is inconclusive due to high statistical fluctuations and a large dependence on the exact method of event selection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Pixel response characterization of the ARCADIA fully depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

Particle tracking detectors↗

The structure of low-lying 1 - states in 90,94 Zr from (α,α'γ) and (p,p'γ) reactions

The low-lying dipole strength in the 90,94 Zr nuclei was investigated via (ρ,ρ'γ) at 80 MeV and (α, α', γ) at 130 MeV. The experiments, made at RCNP, used the magnetic spectrometer Grand Raiden for the scattered particles and the array CAGRA with HPGe detectors for the γ-decay. For 94 Zr these are the first data for both reactions and for 90 Zr these are the first data with (ρ,ρ'γ) and the first ones at high resolution for (α, α', γ). The comparison of the present results for the two nuclei with existing (γ, γ') data shows that both nuclear probes produce an excitation pattern different than that of the electromagnetic probes. DWBA calculations were made using form factors deduced from transition densities, based on RPA calculations, characterized by a strong neutron component at the nuclear surface. A combined analysis of the two reactions was performed for the first time to investigate the isoscalar character of the 1 - states in 90,94 Zr. The (ρ,ρ'γ) cross section was calculated using values for the isoscalar electric dipole energy-weighted sum rule (E1 ISEWSR) obtained from the (α, α', γ) data. The isoscalar strength for 90 Zr was found to exhaust 20 ± 2.5% of the EWSR in the energy range up to 12 MeV. In case of 94 Zr, a strength of 9 ± 1.1% of the EWSR was found in the range up to 8.5 MeV. Although an overall general description was obtained in the studied energy intervals, not all proton cross sections were well reproduced using the isoscalar strength from (α, α', γ). This might suggest mixing of isoscalar and isovector components and that this mixing and the degree of collectivity are not the same for all the 1 - states below the particle binding energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Configuration, Performance, and Commissioning of the ATLAS b-jet Triggers for the 2022 and 2023 LHC data-taking periods

In 2022 and 2023, the Large Hadron Collider produced approximately two billion hadronic interactions each second from bunches of protons that collide at a rate of 40 MHz. The ATLAS trigger system is used to reduce this rate to a few kHz for recording. Selections based on hadronic jets, their energy, and event topology reduce the rate to 𝒪(10) kHz while maintaining high efficiencies for important signatures resulting in b-quarks, but to reach the desired recording rate of hundreds of Hz, additional real-time selections based on the identification of jets containing b-hadrons (b-jets) are employed to achieve low thresholds on the jet transverse momentum at the High-Level Trigger. The configuration, commissioning, and performance of the real-time ATLAS b-jet identification algorithms for the early LHC Run 3 collision data are presented. These recent developments provide substantial gains in signal efficiency for critical signatures; for the Standard Model production of Higgs boson pairs, a 50% improvement in selection efficiency is observed in final states with four b-quarks or two b-quarks and two hadronically decaying τ-leptons.

47 OTHER INSTRUMENTATION↗