Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Synthesis, Structure, and Magnetic Properties of Ni{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} Nanoparticles

Ni{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} precursor solutions with different ratios (where x = 0.0, 0.5, and 1.0) were prepared by sol–gel synthesis using Ni-, Zn-, and Fe-based alkoxides which were dissolved into solvent and chelating agent. Ni{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} nanoparticles, annealed at various temperatures, were observes to determine their doping ratio effects on magnetic and structural properties. The particle size and crystal structure of the nanoparticles were characterized by X-ray diffraction and Size Malvern Instruments Zetasizer Nano-ZS. Magnetic properties of Ni{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} nanoparticles were investigated by a Quantum Design Physical Property Measurement System measurement system. The magnetization and structure of the Ni{sub 1−x}Zn{sub x}Fe{sub 2}O{sub 4} nanoparticles with different doping ratios are presented in this study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A facility for X-ray diffraction in magnetic fields up to 25 T and temperatures between 15 and 295 K

A facility for X-ray diffraction has been developed at the National High Magnetic Field Laboratory. It brings diffraction capability to the 25 T Florida split coil magnet and implements temperature control in a range of 15–295 K using a cold finger helium cryostat. This instrument represents an alternative to pulsed magnetic field systems, and it exceeds the static magnetic fields currently available at synchrotron facilities. Magnetic field compatibility of an X-ray source and detectors with the sizable magnetic fringe fields emanating from the magnet constrained the design of the diffractometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Assembly and Factory Testing of the Jefferson Lab SHMS Spectrometer Quadrupole and Dipole Superconducting Magnets

Jefferson Lab is constructing an 11 Gev/c electron spectrometer called the Super High Momentum Spectrometer (SHMS) as part of the 12 GeV JLAB upgrade for experimental Hall C. Three of the five superconducting(SC) SHMS magnets are under construction at SigmaPhi in Vannes France as a result of an international competition for design and fabrication. The three magnets Q2 and Q3 60 cm bore quadrupoles and the 60 cm warm bore dipole are complete or near complete and have many design features in common. All three magnets share a common superconductor, collaring system, cryostat design, cold to warm support, cryogenic interface, burnout resistant current leads, DC power supply, quench protection, instrumentation and controls. The three magnets are collared, installed in cryostats and welded up and in various stages of final testing. The Q2 quadrupole is due to ship from France to America in August arriving during this ASC conference and has passed all final hipot, leak and pressure tests. The dipole is in leak and pressure testing as of July 2016 while the Q3 quadrupole requires some outer vacuum vessel assembly. Delivery of the Q3 and Dipole magnets will follow the Q2 at about 1 month intervals. Lastly, factory testing have included hipot and electrical tests, magnetic tests at low field, mechanical alignments to center the coils, leak tests and ASME Code required pressure tests. Upon installation in Hall C at JLAB cold testing will commence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Embedded Sensors and Controls to Improve Component Performance and Reliability -- Loop-scale Testbed Design Report

Embedded instrumentation and control systems that can operate in extreme environments are challenging to design and operate. Extreme environments limit the options for sensors and actuators and degrade their performance. Because sensors and actuators are necessary for feedback control, these limitations mean that designing embedded instrumentation and control systems for the challenging environments of nuclear reactors requires advanced technical solutions that are not available commercially. This report details the development of testbed that will be used for cross-cutting embedded instrumentation and control research for nuclear power applications. This research is funded by the Department of Energy's Nuclear Energy Enabling Technology program's Advanced Sensors and Instrumentation topic. The design goal of the loop-scale testbed is to build a low temperature pump that utilizes magnetic bearing that will be incorporated into a water loop to test control system performance and self-sensing techniques. Specifically, this testbed will be used to analyze control system performance in response to nonlinear and cross-coupling fluid effects between the shaft axes of motion, rotordynamics and gyroscopic effects, and impeller disturbances. This testbed will also be used to characterize the performance losses when using self-sensing position measurement techniques. Active magnetic bearings are a technology that can reduce failures and maintenance costs in nuclear power plants. They are particularly relevant to liquid salt reactors that operate at high temperatures (700 C). Pumps used in the extreme environment of liquid salt reactors provide many engineering challenges that can be overcome with magnetic bearings and their associated embedded instrumentation and control. This report will give details of the mechanical design and electromagnetic design of the loop-scale embedded instrumentation and control testbed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Options for Shielding Tokamak Cooling Water Electrical Components against High Magnetic Fields

The Tokamak Cooling Water System (TCWS) Instrumentation and Control (I&C) components of ITER will be located in areas of relatively high magnetic fields. Previous tests on electrical and I&C components have indicated that shielding will be required to protect these components from such magnetic fields. To accomplish this, studies were performed by AREVA Federal Services (AFS) in support of the TCWS Design project with the intent of identifying an optimal solution for shielding I&C components. This report presents a summary of these studies and presents design options for providing magnetic shielding to ITER TCWS I&C components and electrical equipment that are susceptible to the magnetic fields present.

Korsah, Kofi↗

Optimizing the XMaS Beamline for Low energy Operations to Maximize Benefits from the ESRF Upgrade Program

The XMaS beamline at the ESRF has been in regular user operation since April 1998 and operates over an energy range of 2.4-15 keV. It has developed a wide range of unique instrumentation, primarily dedicated to high resolution magnetic and single crystal diffraction. With the upcoming ESRF upgrade program a number of instrumental developments are planned for the beamline to maximize the benefits of the increased photon flux at low energies. Firstly we report on the optimisation of the beamline and its core components. A novel attenuator system which is actuated by fast acting solenoids thereby avoiding problems of gas bursts into the beamline vacuum seen on some commercially available instruments is introduced. Secondly we discuss developments to the low temperature sample environments that have been integrated into the beamline vacuum system, minimizing both air and beryllium absorption. Finally we demonstrate the current capabilities of the beamline by describing preliminary reflectivity measurements that have been made on an [Fe(2ML)Pd(15ML)]x20 multilayer recorded around the Pd L{sub 3} edge using circular polarised light produced from a thin diamond phase plate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A rapid heating and high magnetic field thermal analysis technique

Abstract A new thermal analysis technique is described that allows measurements to be performed on bulk samples at extreme heating and cooling rates and in high magnetic fields. High heating rates, up to 1000 °C min −1 , are achieved through electromagnetic induction heating of a custom-built apparatus fitted with commercial thermal analysis heads and sensor. Rapid cooling rates, up to 100 °C min −1 , are enabled by gas quenching and the small thermal mass of the induction furnace. The custom apparatus is designed to fit inside a superconducting magnet capable of fields up to 9 Tesla. This study demonstrates that the instrument is capable of collecting accurate thermal analysis data in high magnetic fields and rapidly acquiring data for dynamic processes. While the full potential of the technique is still unrealized, currently, it can provide insight into phenomena at time scales relevant to heat treatment in many industrial processes and into little understood effects of high magnetic field processing.

47 OTHER INSTRUMENTATION↗

Design Considerations of Fast-cycling Synchrotrons Based on Superconducting Transmission Line Magnets

Fast-cycling synchrotrons are key instruments for accelerator based nuclear and high-energy physics programs. We explore a possibility to construct fast-cycling synchrotrons by using super-ferric, {approx}2 Tesla B-field dipole magnets powered with a superconducting transmission line. We outline both the low temperature (LTS) and the high temperature (HTS) superconductor design options and consider dynamic power losses for an accelerator with operation cycle of 0.5 Hz. We also briefly outline possible power supply system for such accelerator, and discuss the quench protection system for the magnet string powered by a transmission line conductor.

43 PARTICLE ACCELERATORS↗

Magnetics Testing on Radioisotope Power Systems at the Idaho National Laboratory

National Aeronautics and Space Administration (NASA) uses Radioisotope Power Systems (RPS) to power deep-space and planetary explorations such as Cassini-Huygens, Galileo, New Horizons, Mars Science Laboratory—Curiosity, and most recently Mars 2020--Perseverance. The Space Nuclear Power and Isotope Technologies (SNPIT) division, at Idaho National Laboratory (INL), fuels, tests, and delivers the RPS to ensure it can provide the electrical power needed to complete mission objectives. Some space crafts have instrumentation specifically designed to study the subject’s magnetic field or may have instruments that can be affected by magnetic fields produced by the RPS. Analyzing and measuring the RPS’s magnetic fields ensures the required thresholds are not exceeded and accurate data can be collected for the mission. Magnetics testing provides numerical values of the RPS’s magnetic field. During Magnetics testing at INL, the RPS is placed on a resistive load to simulate actual spacecraft load characteristics (voltage and current). During this simulation, magnetometers are used to measure the magnetic field of the RPS. Raw data is collected and then analyzed to ensure the field created by the RPS is below NASA thresholds or that the magnitude of the field is accounted for to ensure mission success.

42 ENGINEERING↗

DEMAND, a Dimensional Extreme Magnetic Neutron Diffractometer at the High Flux Isotope Reactor

A two-dimensional (2D) Anger camera detector has been used at the HB-3A four-circle single-crystal neutron diffractometer at the High Flux Isotope Reactor (HFIR) since 2013. The 2D detector has enabled the capabilities of measuring sub-mm crystals and spin density maps, enhanced the efficiency of data collection and phase transition detection, and improved the signal-to-noise ratio. Recently, the HB-3A four-circle diffractometer has been undergoing a detector upgrade towards a much larger area, magnetic-field-insensitive, Anger camera detector. The instrument will become capable of doing single-crystal neutron diffraction under ultra-low temperatures (50 mK), magnetic fields (up to 8 T), electric fields (up to 11 kV/mm), and hydrostatic high pressures (up to 45 GPa). Furthermore, half-polarized neutron diffraction is also available to measure weak ferromagnetism and local site magnetic susceptibilities. With the new high-resolution 2D detector, the four-circle diffractometer has become more powerful for studying magnetic materials under extreme sample environment conditions; hence, it has been given a new name: DEMAND.

47 OTHER INSTRUMENTATION↗

Foreword for the special issue on the Tenth International Workshop on Low Energy Electron Microscopy and Photoemission Electron Microscopy

The Tenth International Workshop on Low Energy Electron Microscopy and Photoemission Electron Microscopy (LEEM/PEEM-10) was hosted in Monterey, California on September 11–15, 2016. This Workshop marked the 18th anniversary of the LEEM/PEEM series. The inaugural LEEM Workshop was organized by Ernst Bauer, the inventor of LEEM, and was held 1998 in Tempe, Arizona, USA. Since then this biennial series of meetings was held in locations rotating between America, Asia and Europe. The workshop series is designed to review the status of LEEM, PEEM, SPLEEM, XPEEM and related techniques, and to promote and disseminate applications of cathode lens microscopy to a broad audience of interested scientists. Highlighting the most recent scientific advances and instrumental developments, the LEEM/PEEM-10 meeting was attended by 114 researchers from 17 countries and featured sessions discussing new results on properties of surfaces, thin films, organic films, as well as surface chemistry, magnetism, time resolved methods and instrumental advances and novel applications of LEEM and PEEM to other subject areas.

99 GENERAL AND MISCELLANEOUS↗

Progress on the superconducting undulator for ANKA and on the instrumentation for R and D

Superconducting undulators show a larger magnetic field strength for the same gap and period length, as compared to permanent magnet devices, which allows to generate X-ray beams of higher brilliance and with harder spectrum. The worldwide first short period length superconducting undulator is in operation since 2005 at the synchrotron light source ANKA in Karlsruhe [1]. To further drive the development in this field a research and development program is being carried out. In this contribution we report on the last progress of the construction of a 1.5 m long superconducting undulator with a period length of 15 mm, planned to be installed in ANKA beginning 2010 to be the light source of the new beamline NANO for high resolution X-ray scattering. The key specifications of the system are an undulator parameter K higher than 2 (with a magnetic gap of 5 mm) and a phase error smaller than 3.5 degrees. Cryocoolers will keep the coils at 4.2 K for a beam heat load of 4 W. The ongoing R and D includes improvements in understanding of the magnetic field properties and of the beam heat load mechanisms. The tools and instruments under development to fulfill these tasks are also discussed.

43 PARTICLE ACCELERATORS↗

DVCS - HERMES

The study of Generalised Parton Distributions (GPDs) promises to provide new knowledge of the structure of the nucleon, including, most notably, access to the total angular momentum of quarks within the nucleon. It can be difficult to ascertain new information on the distributions, but amongst all the exclusive processes that can provide access, Deeply Virtual Compton Scattering (DVCS) is relatively simple and experimentally accessible. The HERMES collaboration has the most diverse results pertaining to DVCS of any experiment, extracting asymmetries in the azimuthal distribution of produced photons according to both beam helicity and charge and target spin state. In this talk, we provide an overview of the HERMES DVCS result catalogue and explain how the results are used to improve constraints on the underlying GPDs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Portable 16-channel Magnetic Sensor for Human Magnetocardiographic Experiments

Here, we constructed a portable, low-cost 16-channel magnetic sensor for magnetocardiography (MCG) applications. The sensor is based on a high-sensitivity optically pumped magnetometer (OPM) with a novel configuration of nearly parallel pump and probe laser beams. The OPM-based 16-channel magnetic sensing is realized in a single module by using a fairly large rubidium vapor cell, broad pump/probe laser beams, and a 16-channel photodiode array, leading projected 10-fold reduction of the cost of sensors. The portability of the sensor is achieved by coupling the pump and probe lasers to OPM optics through multi-mode optical fibers. The 16-channel magnetic sensor is surrounded by a non-magnetic enclosure for safe operation. For MCG experiments with the sensor, its main components except lasers are located inside a magnetically shielded room (MSR), which reduces the ambient magnetic noise. The location of lasers and supporting electronics outside the MSR improves the sensitivity of the sensor. We report that the 16-channel magnetic sensor has a magnetic field sensitivity sufficient to directly detect the human cardiac magnetic signals.

16-channel magnetic sensing↗

Electron cyclotron emission detection of neoclassical tearing modes for control for ITER

Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.

Cyclotron radiation↗

Survey of radiation belt energetic electron pitch angle distributions based on the Van Allen Probes MagEIS measurements: Electron Pitch Angle Distributions

A statistical survey of electron pitch angle distributions (PADs) is performed based on the pitch angle-resolved flux observations from the Magnetic Electron Ion Spectrometer (MagEIS) instrument on board the Van Allen Probes during the period from 1 October 2012 to 1 May 2015. By fitting the measured PADs to a sin n α form, where α is the local pitch angle and n is the power law index, we investigate the dependence of PADs on electron kinetic energy, magnetic local time (MLT), the geomagnetic Kp index, and L shell. The difference in electron PADs between the inner and outer belt is distinct. In the outer belt, the common averaged n values are less than 1.5, except for large values of the Kp index and high electron energies. The averaged n values vary considerably with MLT, with a peak in the afternoon sector and an increase with increasing L shell. In the inner belt, the averaged n values are much larger, with a common value greater than 2. The PADs show a slight dependence on MLT, with a weak maximum at noon. A distinct region with steep PADs lies in the outer edge of the inner belt where the electron flux is relatively low. The distance between the inner and outer belt and the intensity of the geomagnetic activity together determine the variation of PADs in the inner belt. Finally, besides being dependent on electron energy, magnetic activity, and L shell, the results show a clear dependence on MLT, with higher n values on the dayside.

79 ASTRONOMY AND ASTROPHYSICS↗

An instrument design for the accurate determination of the electron beam location in the linac coherant light source undulator.

The linac coherent light source (LCLS), currently under design, requires accurate alignment between the electron beam and each undulator's magnetic centerline. A beam finder wire (BFW) instrument has been developed to provide beam location information that is used to move the undulators to their appropriate positions. A BFW instrument is mounted at each of the 33 magnets in the undulator section. Beam detection is achieved by electrons impacting two carbon fiber wires and then sensing the downstream radiation. The wires are mounted vertically and horizontally on a wire card similar to that of a traditional wire scanner instrument. The development of the BFW presents several design challenges due to the need for high accuracy of the wires locations and the need for removal of the wires during actual operation of the LCLS (30 microns repeatability is required for the wire locations). In this paper, we present the technical specification, design criteria, mechanical design, and results from prototype tests for the BFW.

43 PARTICLE ACCELERATORS↗

An Instrument Design for the Accurate Determination of the Electron Beam Location in the Linac Coherent Light Source Undulator

The Linac Coherent Light Source (LCLS), currently under design, requires accurate alignment between the electron beam and each undulator's magnetic centerline. A beam finder wire (BFW) instrument has been developed to provide beam location information that is used to move the undulators to their appropriate positions. A BFW instrument is mounted at each of the 33 magnets in the undulator section. Beam detection is achieved by electrons impacting two carbon fiber wires and then sensing the downstream radiation. The wires are mounted vertically and horizontally on a wire card similar to that of a traditional wire scanner instrument. The development of the BFW presents several design challenges due to the need for high accuracy of the wires locations and the need for removal of the wires during actual operation of the LCLS (30 microns repeatability is required for the wire locations). In this paper, we present the technical specification, design criteria, mechanical design, and results from prototype tests for the BFW.

43 PARTICLE ACCELERATORS↗