Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEASURING APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Interfacial Adhesion Mechanism of Anionic Polyelectrolyte Brushes Induced by Oppositely Charged Macromolecular Counterions

Abstract Polyelectrolyte brushes are widely used as model systems for investigating electrostatic interactions at soft interfaces and to achieve exceptional lubrication properties. Previous studies have primarily focused on their behavior in the presence of multivalent counterions, which induce brush collapse, ionic crosslinking, and pronounced changes in interfacial structures. However, interactions between polyelectrolyte brushes and oppositely charged macromolecular counterions, such as polycations, remain poorly understood. Here, we prepare well-defined polystyrene sulfonate (PSS) brushes fabricated via surface-initiated grafting and employ surface forces apparatus measurements to investigate their interactions with oppositely charged polycations. In contrast to multivalent ions, polycations do not induce noticeable brush collapse, but instead generate significant adhesion between symmetric PSS brush layers. This adhesion increases with both contact time and applied load, eventually reaching a steady plateau, indicating that the interaction is governed not simply by electrostatic screening but by the gradual formation of polycation-mediated bridging under confinement. Furthermore, the introduction of monovalent Na+ ions disrupts the adhesive interaction even at very low concentrations, suggesting that the bridging function of the adsorbed polycation is highly sensitive to competitive ionic screening. In comparison, measurements with trivalent counterions reveal the expected brush collapse behavior but minimal dependence of adhesion on contact time, highlighting a clear mechanistic distinction from the polymeric counterion case. Collectively, these results demonstrate that molecular size, configurational restriction, and confinement-induced rearrangement, rather than charge valency alone, govern the interaction behavior of macromolecular counterions at brush interfaces. This work provides new insight into the molecular origins of adhesion and the regulation of interfacial interactions in charged polymer brush systems.

Park, Jinwoo [Argonne National Laboratory , , , ,;↗

Challenges in Rotor Aerodynamic Modeling for Non-Uniform Inflow Conditions

Within an international collaboration framework, the accuracy of rotor aerodynamic models used for design load calculations of wind turbines is being assessed. Where the use of high-fidelity computation fluid dynamics (CFD) and mid-fidelity free-vortex wake (FVW) models has become commonplace within the wind energy community, these still fail to meet the requirements in terms of execution time and computational cost needed for design load calculations. The fast but engineering fidelity blade-element/momentum (BEM) method can therefore still be considered the industry workhorse for design load simulations. At the same time, upscaling of wind turbine rotors makes inflow non-uniformities (e.g. shear, veer, turbulence) more important. The objective of this work is to assess model accuracy in non-uniform inflow conditions, which violate several BEM assumptions. Thereto a comparison in turbulent inflow has been executed including a wide variety of codes, focusing on the DanAero field measurements, where a 2.3-MW turbine was equipped with, among other sensors, a pressure measurement apparatus. The results indicate that, although average load patterns are in good agreement, this does not hold for the unsteady loads that drive fatigue damage and aero-elastic stability. A simplified comparison round in vertical shear was initiated to investigate the observed differences in a more controlled manner. A consistent offset in load amplitude was observed between CFD and free-vortex codes on the one hand and BEM-type codes on the other hand. To shed more light on the observations, dedicated efforts are ongoing to pinpoint the cause for these differences, in the end leading to guidelines for an improved BEM implementation.

17 WIND ENERGY↗

Physical thickness characterization of the FRIB production targets

The FRIB heavy-ion accelerator, commissioned in 2022, is a leading facility for producing rare isotope beams (RIBs) and exploring nuclei beyond the limits of stability. These RIBs are produced via reactions between stable primary beams and a graphite target. Approximately 20–40% of the primary beam power is deposited in the target, requiring efficient thermal dissipation. Currently, FRIB operates with a primary beam power of up to 20 kW. To enhance thermal dissipation efficiency, a single-slice rotating graphite target with a diameter of approximately 30 cm is employed. The effective target region is a 1 cm-wide outer rim of the graphite disc. To achieve high RIB production rates, the areal thickness variation must be constrained within 2%. This paper presents physical thickness characterizations of FRIB production targets with various nominal thicknesses, measured using a custom-built non-contact thickness measurement apparatus.

Instrumentation for radioactive beams (fragmentati↗

Design and Validation of a Cryogenic Dilatometer

This project focuses on the design and development of a cryogenic dilatometer capable of measuring the thermal expansion of materials at extremely low temperatures. Understanding how materials change dimension with temperature is critical for applications involving cryogenic environments, particularly laminated systems housing superconducting magnets, where small dimensional changes can significantly affect performance and reliability. To address this, a dilatometer system was designed to operate within a liquid nitrogen environment while accurately measuring displacements caused by thermal contraction. The purpose of this device is to determine the coefficient of thermal expansion (CTE) of a material. The design process involved defining functional requirements, developing mechanical and thermal concepts for the measurement apparatus, selecting appropriate materials compatible with cryogenic temperatures, and integrating sensors capable of detecting small dimensional changes. The resulting system aims to provide a practical and repeatable method for evaluating material thermal expansion at cryogenic temperatures, supporting research into composite use in superconducting applications that require accurate characterization of material behavior in low-temperature environments.

Schmitt, Nicholas [Northern Illinois U.]↗

Remote probing of the optical strength of atmospheric turbulence and of wind velocity

A procedure for determining the optical strength of turbulence of the atmosphere and the wind velocity at various altitudes by measuring the spatial and temporal covariance of scintillation is developed. Emphasis is placed on the development of the formal relationships that have to be inverted to obtain the desired results. For determination of optical strength of turbulence, it is a linear integral equation that is developed. However, for determination of remote wind velocity, a nonlinear integral equation is obtained. A computer approach for solving each of the equations is suggested. The configuration and performance requirements of the measurement apparatus are discussed.

Fried, D. L.↗

Absolute photon-flux measurements in the vacuum ultraviolet

Absolute photon-flux measurements in the vacuum ultraviolet have extended to short wavelengths by use of rare-gas ionization chambers. The technique involves the measurement of the ion current as a function of the gas pressure in the ion chamber. The true value of the ion current, and hence the absolute photon flux, is obtained by extrapolating the ion current to zero gas pressure. Examples are given at 162 and 266 A. The short-wavelength limit is determined only by the sensitivity of the current-measuring apparatus and by present knowledge of the photoionization processes that occur in the rate gases.

Samson, J. A. R.↗

USDI DCS technical support: Mississippi Test Facility

The objective of the technical support effort is to provide hardware and data processing support to DCS users so that application of the system may be simply and effectively implemented. Technical support at Mississippi Test Facility (MTF) is concerned primarily with on-site hardware. The first objective of the DCP hardware support was to assure that standard measuring apparatus and techniques used by the USGS could be adapted to the DCS. The second objective was to try to standardize the miscellaneous variety of parameters into a standard instrument set. The third objective was to provide the necessary accessories to simplify the use and complement the capabilities of the DCP. The standard USGS sites have been interfaced and are presently operating. These sites are stream gauge, ground water level and line operated quality of water. Evapotranspiration, meteorological and battery operated quality of water sites are planned for near future DCP operation. Three accessories which are under test or development are the Chu antenna, solar power supply and add-on memory. The DCP has proven to be relatively easy to interface with many monitors. The large antenna is awkward to install and transport. The DCS has met the original requirements well; it has and is proving that an operation, satellite-based data collection system is feasible.

Preble, D. M.↗

Development of Skylab medical equipment and flight preparations

The major medical systems in the Skylab orbital workshop are described. They comprise the food system, the waste management system, operational bioinstrumentation, personal hygiene, gas sampling, an inflight medical support system, and a cardiovascular counterpressure garment. Life sciences experiments carried out aboard Skylab are also reviewed; these include an ergometer and metabolic analyzer, a lower-body negative pressure device, an electrode harness and body temperature probe, a blood pressure cuff, a leg volume measuring band, sleep studies, a body-mass measuring device, a rotating litter chair, a blood sample processor, and small-mass measuring apparatus. All performance requirements were met with the equipment, and no failures were encountered.

Johnston, R. S.↗