At least 199 records · Page 11

Eruption of a Multiple-Turn Helical Magnetic Flux Tube in a Large Flare: Evidence for External and Internal Reconnection that Fits the Breakout Model of Solar Magnetic Eruptions

We present observations and an interpretation of a unique multiple-turn spiral flux tube eruption from active region 10030 on 2002 July 15. The TRACE C IV observations clearly show a flux tube that is helical and erupting from within a sheared magnetic field. These observations are interpreted in the context of the breakout model for magnetic field explosions. The initiation of the helix eruption. as determined by a linear backward extrapolation, starts 25 s after the peak of the flare's strongest impulsive spike of microwave gyrosynchrotron radiation early in the flare s explosive phase, implying that the sheared core field is not the site of the initial reconnection. Within the quadrupolar configuration of the active region, the external and internal reconnection sites are identified in each of two consecutive eruptive flares that produce a double coronal mass ejection (CME). The first external breakout reconnection apparently releases an underlying sheared core field and allows it to erupt, leading to internal reconnection in the wake of the erupting helix. This internal reconnection releases the helix and heats the two-ribbon flare. These events lead to the first CME and are followed by a second breakout that initiates a second and larger halo CME. The strong magnetic shear in the region is compatible with the observed rapid proper motion and evolution of the active region. The multiple-turn helix originates from above a sheared-field magnetic inversion line within a filament channel. and starts to erupt only after fast breakout reconnection has started. These observations are counter to the standard flare model and support the breakout model for eruptive flare initiation.

Gary, G. Allen↗

Satellite Power System (SPS) magnetron tube assessment study

The data base was extended with respect to the magnetron directional amplifier and its operating parameters that are pertinent to its application in the solar power satellite. On the basis of the resulting extended data base the design of a magnetron was outlined that would meet the requirements of the SPS application and a technology program was designed that would result in its development. The proposed magnetron design for the SPS is a close scale of the microwave oven magnetron, and resembles it closely physically and electrically.

Brown, W. C.↗

Grating lobe characteristics and associated impacts upon the solar power satellite microwave system

The object of this investigation is to determine the grating lobe characteristics for the SPS (solar power satellite) microwave power beam. Using techniques of Fourier array decomposition, equations, and numerical results are given for the complete SPS microwave antenna pattern (main beam plus grating lobes). In order to ensure the grating lobe peaks are below the environmental guideline of 0.01 mW/sq cm, constraints are defined for the mechanical alignment (tilt) of the SPS antenna and the satellite attitude control system. Two conditions, phase control to the subarray level and to the power module (tube) level, are analyzed as to their effects upon grating lobes.

Kerwin, E. M.↗

Microwave tunable laser source: A stable, precision tunable heterodyne local oscillator

The development and capabilities of a tunable laser source utilizing a wideband electro-optic modulator and a CO2 laser are described. The precision tunability and high stability of the device are demonstrated with examples of laboratory spectroscopy. Heterodyne measurements are also presented to demonstrate the performance of the laser source as a heterodyne local oscillator. With the use of five CO2 isotope lasers and the 8 to 18 GHz sideband offset tunability of the modulator, calculations indicate that 50 percent spectral coverage in the 9 to 12 micron region is achievable. The wavelength accuracy and stability of this laser source is limited by the CO2 laser and is more than adequate for the measurement of narrow Doppler-broadened line profiles. The room-temperature operating capability and the programmability of the microwave tunable laser source are attractive features for its in-the-field implementation. Although heterodyne measurements indicated some S/N degradation when using the device as a local oscillator, there does not appear to be any fundamental limitation to the heterodyne efficiency of this laser source. Through the use of a lower noise-figure traveling wave tube amplifier and optical matching of the output beam with the photomixer, a substantial increase in the heterodyne S/N is expected.

Sachse, G. W.↗

Compact, Highly Stable Ion Atomic Clock

A mercury-ion clock now at the breadboard stage of development (see figure) has a stability comparable to that of a hydrogen-maser clock: In tests, the clock exhibited an Allan deviation of between 2 x 10(exp -13) and 3 x 10(exp -13) at a measurement time of 1 second, averaging to about 10(exp -15) at 1 day. However, the clock occupies a volume of only about 2 liters . about a hundredth of the volume of a hydrogen-maser clock. The ion-handling parts of the apparatus are housed in a sealed vacuum tube, wherein only a getter pump is used to maintain the vacuum. Hence, this apparatus is a prototype of a generation of small, potentially portable high-precision clocks for diverse ground- and space-based navigation and radio science applications. Furthermore, this new ion-clock technology is about 100 times more stable and precise than the rubidium atomic clocks currently in use in the NAV STAR GPS Earth-orbiting satellites. In this clock, mercury ions are shuttled between a quadrupole and a 16-pole linear radio-frequency trap. In the quadrupole trap, the ions are tightly confined and optical state selection from a Hg-202 radio-frequency-discharge ultraviolet lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions resonant at frequency of about 40.507 GHz are interrogated by use of a microwave beam at that frequency. The trapping of ions effectively eliminates the frequency pulling caused by wall collisions inherent to gas-cell clocks. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave- resonance process, so that each of these processes can be optimized independently of the other. The basic ion-shuttling, two-trap scheme as described thus far is not new: it has been the basis of designs of prior larger clocks. The novelty of the present development lies in major redesigns of its physics package (the ion traps and the vacuum and optical subsystems) to effect the desired reduction of size to a volume of no more than a couple of liters. The redesign effort has included selection of materials for the vacuum tube, ion trap, and ultraviolet windows that withstand bakeout at a temperature of approx.450 C in preparation for sealing the tube to contain the vacuum. This part of the redesign effort follows the approach taken in the development of such other vacuum-tube electronic components as flight traveling- wave-tube amplifiers having operational and shelf lives as long as 15 years. The redesign effort has also included a thorough study of residual-gas-induced shifts of the ion-clock frequency and a study of alternative gases as candidates for use as a buffer gas within the sealed tube. It has been found that neon is more suitable than is helium, which has been traditionally used for this purpose, in that the pressure-induced frequency pulling by neon is between a third and a half of that of helium. In addition, because neon diffuses through solids much more slowly than does helium, the loss of neon by diffusion over the operational lifetime is expected to be negligible.

Prestage, John↗

Electron-cyclotron maser emission during flares: Emission in various modes and temporal variations

Absorption of radiation at the electron-cyclotron frequency, OMEGA sub e, generated by the electron-cyclotron maser instability was proposed as a possible mechanism for transporting energy and heating of the corona during flares. Radiation from the same instability but at harmonics of OMEGA sub e is believed to be the source of solar microwave spike bursts. The actual mode and frequency of the dominant emission from the maser instability is shown to be dependent on: (1) the plasma temperature, (2) the form of the energetic electron distribution, and (3) on the ratio of the plasma frequency omega sub p to OMEGA sub e. As a result, the emission along a flux tube can vary, with emission at harmonics being favored in regions where omega sub p/OMEGA sub e approx. equal to or greater than 1. Changes in the plasma density and temperature in the source region associated with the flare can also cause the characteristics of the emission to change in time.

Winglee, R. M.↗

An optimal structure for a 34-meter millimeter-wave center-fed BWG antenna: The Cross-Box concept

An approach to the design of the planned NASA/JPL 34 m elevation-over-azimuth (Az-El) antenna structure at the Venus site (DSS-13) is presented. The antenna structural configuration accommodates a large (2.44 m) beam waveguide (BWG) tube centrally routed through the reflector-alidade structure, an elevation wheel design, and an optimal structural geometry. The design encompasses a cross-box elevation wheel-reflector base substructure that preserves homology while satisfying many constraints, such as structure weight, surface tolerance, stresses, natural frequency, and various functional constraints. The functional requirements are set to ensure that microwave performance at millimeter wavelengths is adequate. The cross-box configuration was modeled, optimized, and found to satisfy all DSN HEF baseline antenna specifications. In addition, the structure design was conceptualized and analyzed with an emphasis on preserving the structure envelope and keeping modifications relative to the HEF antennas to a minimum, thus enabling the transferability of the BWG technology for future retrofitting. Good performance results were obtained.

Chuang, K. L.↗

Power-Efficient, High-Current-Density, Long-Life Thermionic Cathode Developed for Microwave Amplifier Applications

A power-efficient, miniature, easily manufactured, reservoir-type barium-dispenser thermionic cathode has been developed that offers the significant advantages of simultaneous high electron-emission current density (>2 A/sq cm) and very long life (>100,000 hr of continuous operation) when compared with the commonly used impregnated-type barium-dispenser cathodes. Important applications of this cathode are a wide variety of microwave and millimeter-wave vacuum electronic devices, where high output power and reliability (long life) are essential. We also expect it to enable the practical development of higher purveyance electron guns for lower voltage and more reliable device operation. The low cathode heater power and reduced size and mass are expected to be particularly beneficial in traveling-wave-tube amplifiers (TWTA's) for space communications, where future NASA mission requirements include smaller onboard spacecraft systems, higher data transmission rates (high frequency and output power) and greater electrical efficiency.

Wintucky, Edwin G.↗

Making and Inspecting Large Wire Grids

Old techniques refined and combined to make new polarizers. Equipment and procedures developed for fabrication and inspection of large, precisely-spaced, flat grids of wire. Technology includes refinements and combinations of established techniques for winding grids of electron tubes and ruling optical gratings and incorporates recent developments in electronic control and laser/electronic-based metrology. Wire wrapped on frame half translated under automatic control to achieve desired space between turns. Frame halves put together, and excess wire cut away, leaving finished grid mounted in frame. Useful as polarizers and beam splitters for electromagnetic radiation in overlapping ranges of long infrared and microwaves.

Magner, Thomas J.↗

Miniature Low-Mass Drill Actuated by Flextensional Piezo Stack

Recent experiments with a flextensional piezoelectric actuator have led to the development of a sampler with a bit that is designed to produce and capture a full set of sample forms including volatiles, powdered cuttings, and core fragments. The flextensional piezoelectric actuator is a part of a series of devices used to amplify the generated strain from piezoelectric actuators. Other examples include stacks, bimorphs, benders, and cantilevers. These devices combine geometric and resonance amplifications to produce large stroke at high power density. The operation of this sampler/drill was demonstrated using a 3x2x1-cm actuator weighing 12 g using power of about 10-W and a preload of about 10 N. A limestone block was drilled to a depth of about 1 cm in five minutes to produce powdered cuttings. It is generally hard to collect volatiles from random surface profiles found in rocks and sediment, powdered cuttings, and core fragments. Toward the end of collecting volatiles, the actuator and the bit are covered with bellows-shaped shrouds to prevent fines and other debris from reaching the analyzer. A tube with a miniature bellows (to provide flexibility) is connected to the bit and directs the flow of the volatiles to the analyzer. Another modality was conceived where the hose is connected to the bellows wall directly to allow the capture of volatiles generated both inside and outside the bit. A wide variety of commercial bellows used in the vacuum and microwave industries can be used to design the volatiles capture mechanism. The piezoelectric drilling mechanism can potentially be operated in a broad temperature range from about-200 to less than 450 C. The actuators used here are similar to the actuators that are currently baselined to fly as part of the inlet funnel shaking mechanism design of MSL (Mars Science Laboratory). The space qualification of these parts gives this drill a higher potential for inclusion in a future mission, especially when considering its characteristics of low mass, small size, low power, and low axial loads for sampling.

Sherrit, Stewart↗

A Test-Bed Validation of Electromagnetic Surface Wave Propagation Along a Dielectric-Coated Metal Pipe

This paper provides a summary of the results of an attempt at experimental verification of the propagation of electromagnetic surface waves at microwaves frequencies, in and along the uniform dielectric coating of a circular cylindrical metal pipe, based on the previously established theoretical investigation. These experimental results are of value for the diagnostic of anomalies on the surface of tar-coated pipes used in protecting the underground power transmission cables (feeder pipes). A test-bed was designed and implemented using an aluminum tubes (10” diameter) with an acrylic tube coating (0.25” thickness). Two identical wave launcher/receiver arrays, each of 32 elements around the tube for relatively uniform radiation/reception, were designed and fabricated at the frequency of interest (~6 GHz). This arrangement was put in a specially designed small anechoic chamber and attached to a network analyzer. A variety of tests were performed to establish the launch efficiency, prove surface wave propagation along, and reflection from different types of anomalies on the coating. In the paper, a number of test results and supporting graphs will be provided and future work for improving the performance of the launch array and the test-bed arrangement for better results will be outlined.

Gatti, Mark↗

A Ka-Band Wide-Bandgap Solid-State Power Amplifier: Architecture Performance Estimates

Motivated by recent advances in wide-bandgap (WBG) gallium nitride (GaN) semiconductor technology, there is considerable interest in developing efficient solidstate power amplifiers (SSPAs) as an alternative to the traveling-wave tube amplifier (TWTA) for space applications. This article documents the results of a study to investigate power-combining technology and SSPA architectures that can enable a 120-W, 40 percent power-added efficiency (PAE) SSPA. Results of the study indicate that architectures based on at least three power combiner designs are likely to enable the target SSPA. The proposed architectures can power combine 16 to 32 individual monolithic microwave integrated circuits (MMICs) with >80 percent combining efficiency. This corresponds to MMIC requirements of 5- to 10-W output power and >48 percent PAE. For the three proposed architectures [1], detailed analysis and design of the power combiner are presented. The first architecture studied is based on a 16-way septum combiner that offers low loss and high isolation over the design band of 31 to 36 GHz. Analysis of a 2-way prototype septum combiner had an input match >25 dB, output match >30 dB, insertion loss <0.02 dB, and isolation >30 dB over the design band. A 16-way design, based on cascading this combiner in a binary fashion, is documented. The second architecture is based on a 24-way waveguide radial combiner. A prototype 24-way radial base was analyzed to have an input match >30 dB (under equal excitation of all input ports). The match of the mode transducer that forms the output of a radial combiner was found to be >27 dB. The functional bandwidth of the radial base and mode transducer, which together will form a radial combiner/divider, exceeded the design band. The third architecture employs a 32-way, parallel-plate radial combiner. Simulation results indicated an input match >24 dB, output match >22 dB, insertion loss <0.23 dB, and adjacent port isolation >20 dB over the design band. All three architectures utilize a low-loss MMIC amplifier module based on commercial MMIC packaging and a custom microstrip-to-rectangular-waveguide transition. The insertion loss of the module is expected to be 0.45 dB over the design band.

Epp, L.↗

NASA Tech Briefs, December 2013

Topics include: Microwave Kinetic Inductance Detector With; Selective Polarization Coupling; Flexible Microstrip Circuits for; Superconducting Electronics; CFD Extraction Tool for TecPlot From DPLR Solutions; RECOVIR Software for Identifying Viruses; Enhanced Contact Graph Routing (ECGR) MACHETE Simulation Model; Orbital Debris Engineering Model (ORDEM) v.3; Scatter-Reducing Sounding Filtration Using a Genetic Algorithm and Mean Monthly Standard Deviation; Thermo-Mechanical Methodology for Stabilizing Shape Memory Alloy Response; Hermetic Seal Designs for Sample Return Sample Tubes; Silicon Alignment Pins: An Easy Way To Realize a Wafer-to-Wafer Alignment; Positive-Buoyancy Rover for Under Ice Mobility; Electric Machine With Boosted Inductance to Stabilize Current Control; International Space Station-Based Electromagnetic Launcher for Space Science Payloads; Advanced Hybrid Spacesuit Concept Featuring Integrated Open Loop and Closed Loop Ventilation Systems; Data Quality Screening Service.

Source record↗

High efficiency RF sources developments

Calabazas Creek Research, Inc. (CCR) and its collaborators are developing high efficiency RF sources operating from a few hundred MHz to C-Band and power levels from tens to hundreds of kilowatts with the goal of providing MW-relevant sources. The efficiencies approach or exceed 80% with projected costs as low as $0.50/ Watt. Sources under development include magnetrons with phase and amplitude control, single and multi-beam klystrons, multi-beam power grid tubes, and multiple beam IOTs. A magnetron system achieved more than 80% efficiency with fast amplitude control using modulation of the phase locking signal. This would be a low cost, high efficiency RF source for superconducting accelerators. An L-Band, single beam klystron was built with simulated efficiency of 80%. The klystron has yet to be tested to confirm the simulation results. CCR is currently developing a multi-beam klystron to produce more than 200 kW CW at 80% efficiency. Also in development is a multiple beam triode to produce 200 kW CW from 300 MHz to approximately 1 GHz. Not only does the simulated efficiency exceed 75%, but it would be the lowest cost RF source in this frequency range. Finally, CCR recently concluded research for a multiple beam IOT at 700 MHz using third harmonic drive to boost efficiency toward 85%. Successful development and transition to production of these sources will significantly alter the cost/performance landscape for RF power generation.

43 PARTICLE ACCELERATORS↗

Ka-Band Wide-Bandgap Solid-State Power Amplifier: Hardware Validation

Motivated by recent advances in wide-bandgap (WBG) gallium nitride (GaN) semiconductor technology, there is considerable interest in developing efficient solid-state power amplifiers (SSPAs) as an alternative to the traveling-wave tube amplifier (TWTA) for space applications. This article documents proof-of-concept hardware used to validate power-combining technologies that may enable a 120-W, 40 percent power-added efficiency (PAE) SSPA. Results in previous articles [1-3] indicate that architectures based on at least three power combiner designs are likely to enable the target SSPA. Previous architecture performance analyses and estimates indicate that the proposed architectures can power combine 16 to 32 individual monolithic microwave integrated circuits (MMICs) with >80 percent combining efficiency. This combining efficiency would correspond to MMIC requirements of 5- to 10-W output power and >48 percent PAE. In order to validate the performance estimates of the three proposed architectures, measurements of proof-of-concept hardware are reported here.

Epp, L.↗

Compact Microwave Mercury Ion Clock for Deep-Space Applications

We have recently completed a breadboard ion-dock physics package based on Kg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability -1-2xl0-13 at 1 second, averaging to 10-15 at 1 day. This development shows that 8- maser quality stabilities can be produced in a small clock package, comparable in size to an oItra-stable quartz oscillator required for holding 1-2xl0-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only agetter pump was used to maintain vacuum. The vacuum tube containing the traps has now been onder sealed vacuum conditions for nearly two years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow a - 400 C tube bake-out to prepare for tube sealoff. This approach to the vacuum follows the methods used in mght vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved. We use neon as a buffer gas with 2-3 times less pressure induced frequency pulling than helium and, being heavier, negligable diffusion losses will occur over the operation lifetime.

space clock↗

Carbon Nanotubes as Resonators for RF Spectrum Analyzers

Electromechanical resonators of a proposed type would comprise single carbon nanotubes suspended between electrodes (see Figure 1). Depending on the nanotube length, diameter, and tension, these devices will resonate at frequencies in a range from megahertz through gigahertz. Like the carbon-nanotube resonators described in the preceding article, these devices will exhibit high quality factors (Q values), will be compatible with integration with electronic circuits, and, unlike similar devices made from silicone and silicone carbide, will have tunable resonant frequencies as high as several GHz. An efficient electromechanical transduction method for the carbon nanotube resonators is provided by the previously observed variation of carbon nanotube length with charge injection. It was found that injection of electrons or holes, respectively, lengthens or shortens carbon nanotubes, by amounts of the order of a percent at bias levels of a few volts. The charge-dependent length change also enables a simple and direct means of tuning the resonant frequency by varying the DC bias and hence the tension along the tube, much like tuning a guitar string. In its basic form, the invention is a tunable high-Q resonator based on a suspended carbon nanotube bridge with attached electrodes (see Figure 1). An applied DC bias controls the tension and thus the frequency of resonance. If one were to superimpose a radio-frequency (RF) bias on the DC bias, then the resulting rapid variation in tension or length would set the tube into vibration. If, on the other hand, the carbon nanotube were to be set into vibration by interaction between an incident RF electric field and electric charges in the nanotube, then the vibration would give rise to an RF signal output that is proportional to the RF amplitude at the resonance frequency. Because the transduction mechanism is extremely sensitive and the active volume is only a few nanometers in diameter, this device is not well suited for use as a microwave power device. Instead, this carbon nanotube mechanical resonator would be useful primarily as part of a highly precise, sensitive, frequency-selective detector. An array of such devices featuring nanotubes of different lengths (and thus different frequencies) could be made to operate as a highspeed spectrum analyzer (see Figure 2)

Hunt, Brian↗

Compact Microwave Mercury Ion Clock for Space Applications

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approximately 1 - 2 x 10(exp -13) at 1 second, averaging to 10(exp -15) at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1 - 2 x 10(exp -13) at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly three years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow an approximately 400 C bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved.

Atomic Clock↗