Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONITOR PROGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Annual Groundwater Detection Monitoring Report for the Idaho CERCLA Disposal Facility (2008)

This report presents the data collected for groundwater detection monitoring at the Idaho Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) Disposal Facility (ICDF) during calendar year 2008. The detection-monitoring program developed for the ICDF groundwater-monitoring wells is applicable to six wells completed in the uppermost portion of the Snake River Plain Aquifer - five wells downgradient of the ICDF and one well upgradient. The ICDF detection-monitoring program was established to meet the substantive requirements of Title 40 Code of Federal Regulations (CFR) Parts 264.97 and 264.98, which are applicable or relevant and appropriate requirements under CERCLA. Semiannual groundwater samples were collected and analyzed for indicator parameters in March and September. The indicator parameters focus on constituents that are found in higher concentrations in ICDF leachate than in groundwater (bicarbonate alkalinity, sulfate, U-233, U-234, and U-238). The only detection monitoring limits that were exceeded were for bicarbonate alkalinity. Bicarbonate alkalinity is naturally occurring in groundwater. Bicarbonate alkalinity found in ICDF detection monitoring wells is not a result of waste migration from the ICDF landfill or the evaporation pond. The U.S. Department of Energy will continue with detection monitoring for the ICDF, which is semiannual sampling for indicator parameters.

54 ENVIRONMENTAL SCIENCES↗

Air quality monitor and acid rain networks

The air quality monitor program which consists of two permanent air monitor stations (PAMS's) and four mobile shuttle pollutant air monitor stations (SPAMS's) is evaluated. The PAMS measures SO sub X, NO sub X particulates, CO, O3, and nonmethane hydrocarbons. The SPAMS measures O3, SO2, HCl, and particulates. The collection and analysis of data in the rain monitor program are discussed.

Rudolph, H.↗

Microbial Ecology of NASA Curation Clean Rooms

Clean room standards like ISO 14644 used for facilities that construct spacecraft and store returned samples do not explicitly account for microbial contamination. While there are associated ISO standards for monitoring and controlling bio-contamination in clean rooms it is not always standard practice to do so. The NASA Astromaterials Acquisition and Curation Office maintains seven separate clean labs for storing extraterrestrial samples from the Moon, meteorites, cosmic dust, asteroids, comets, solar wind particles, and microparticle impact samples. These labs are routinely monitored for particulate and trace metal contamination. However, the sample collections are either non-sterile at the time of collection (e.g., meteorites) or are no longer being used to address scientific questions that could be affected by non-sterile conditions (e.g., Lunar samples). Outside of isolated studies there has not been a systematic, longitudinal characterization of the microbial ecology of NASA curation clean rooms. In accordance with the advanced curation initiative, and to prepare for future sample return missions, we have initiated a routine microbiological monitoring program in the Antarctic Meteorite Lab. This monitoring program will be used to determine what microbes are capable of surviving in these oligotrophic environments and whether or not they are capable of altering the sample collections in any significant manner. Repeat sampling will allow us to understand how routine use of these labs affects the microbial ecology over time.

Regberg, A. B.↗

ROLE OF TOXICITY ASSESSMENT AND MONITORING IN MANAGING THE RECOVERY OF A WASTEWATER RECEIVING STREAM

We evaluate the roles of a long-term comprehensive toxicity assessment and monitoring program in management and for ecological recovery of a freshwater receiving stream impacted by industrial discharges and legacy contamination. National Pollution Discharge Elimination Permit (NPDES)-driven whole effluent toxicity (WET) tests using Ceriodaphnia and fathead minnows were conducted for more than twenty years to characterize wastewaters at the US National Nuclear Security Agency s Y-12 National Security Complex in Oak Ridge, Tennessee. Ambient toxicity tests also were conducted to assess water samples from EFPC, the stream receiving the wastewater discharges. The ambient tests were conducted as part of an extensive biological monitoring program that included routine surveys of fish, invertebrate and periphyton communities. WET testing, associated toxicant identification evaluations (TIEs), and ambient toxicity monitoring were instrumental in identifying toxicants and their sources at the Y-12 Complex, guiding modifications to wastewater treatment procedures, and assessing the success of various pollution-abatement actions. Through time, as requirements changed and water quality improved, the toxicity monitoring program became more focused. Ambient testing with Ceriodaphnia and fathead minnow larvae also was supplemented with less-standardized but more-sensitive alternative laboratory and in situ bioassays. The Y-12 Complex biological monitoring experience demonstrates the significant roles effluent and ambient toxicity testing can have in controlling and managing toxic discharges to receiving waters. It also emphasizes the value of supplementing WET and standardized ambient toxicity tests with alternative laboratory and in situ toxicity tests tailored to address specific problems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Verifying PLC Programs via Monitors: Extending the Integration of FRET and PLCverif

Verification of Programmable Logic Controller (PLC) programs requires reasoning about propositions qualified in terms of time. CERN’s PLCverif, an open-source tool for the analysis of safety-critical PLC systems, uses Linear Temporal Logic (LTL) for the specification of properties. Until now, PLCverif depended on third-party tools that accept LTL specifications to perform verification. However, our experience with industrial PLC programs shows that, to overcome analysis limitations, a wide range of techniques are needed to successfully verify complex properties. In this paper, we extend PLCverif to enable PLC program verification of pure-past LTL (PLTL) safety properties with assertion-based verification tools. To this end, we take an algorithm from the runtime-monitoring domain, apply it to bounded model checking of PLC programs, and implement it in PLCverif. We extend the integration of NASA’s Formal Requirements Elicitation Tool (FRET) into PLCverif to use PLTL properties generated with FRET. In addition, we leverage the program structure induced by the PLC scan-cycle for a state-space reduction. Finally, we expose the algorithm to a real-world case study of critical systems at CERN.

Formal verification↗

Performance Metrics for Monitoring Parallel Program Executions

Existing tools for debugging performance of parallel programs either provide graphical representations of program execution or profiles of program executions. However, for performance debugging tools to be useful, such information has to be augmented with information that highlights the cause of poor program performance. Identifying the cause of poor performance necessitates the need for not only determining the significance of various performance problems on the execution time of the program, but also needs to consider the effect of interprocessor communications of individual source level data structures. In this paper, we present a suite of normalized indices which provide a convenient mechanism for focusing on a region of code with poor performance and highlights the cause of the problem in terms of processors, procedures and data structure interactions. All the indices are generated from trace files augmented with data structure information.. Further, we show with the help of examples from the NAS benchmark suite that the indices help in detecting potential cause of poor performance, based on augmented execution traces obtained by monitoring the program.

Sarukkai, Sekkar R.↗

Monitoring Java Programs with Java PathExplorer

We present recent work on the development Java PathExplorer (JPAX), a tool for monitoring the execution of Java programs. JPAX can be used during program testing to gain increased information about program executions, and can potentially furthermore be applied during operation to survey safety critical systems. The tool facilitates automated instrumentation of a program's late code which will then omit events to an observer during its execution. The observer checks the events against user provided high level requirement specifications, for example temporal logic formulae, and against lower level error detection procedures, for example concurrency related such as deadlock and data race algorithms. High level requirement specifications together with their underlying logics are defined in the Maude rewriting logic, and then can either be directly checked using the Maude rewriting engine, or be first translated to efficient data structures and then checked in Java.

Havelund, Klaus↗

First Step in Validating the Radiological Inventories of the Current French Nuclear Fleet - 19000

To anticipate the evolution of the mechanical characteristics of its PWR vessels, EDF developed a vessels fluence monitoring program. This program was based on vessel samples and neutron dosimeters deployed between the fuel assemblies and vessels. These samples and dosimeters are regularly analyzed in laboratories. To calculate the radioactive inventories, we have developed a calculation scheme which includes a 3D mapping of the neutron flux, the calculation of the radiological inventories of the structures of interest, and finally the validation of the results. The validation needs samples to propose calculation/measurement ratios. Unfortunately before the final shut down, the internal and vessel samplings are not possible. To anticipate the decommissioning of the current French nuclear fleet, this paper shows how the samples of the vessels fluence monitoring program can be used to validate the calculated radiological inventories. Using state-of-the-art simulations (i.e. 3D geometric model, 3D neutron sources, 3D neutron propagation, operational fuel loading coupled with effective power distributions) we calculated the radiological inventories of some vessel fluence monitoring program samples. The comparisons between calculated and measured results were done on 'standard chemical elements'. To qualify a chemical element as 'standard', many criteria must be satisfied such as a high concentration level, a low uncertainty about concentration, activation into an expanded cross section range, production of radionuclides having significant half-lives and finally no difficulties measuring the radionuclides produced. The retained 'standard' is Fe which produces, under neutrons flux, Fe-55. The comparisons show that the calculations slightly overestimate the measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Supplemental Assessment of the Y-12 Groundwater Protection Program Using Monitoring and Remediation Optimization System Software

A supplemental quantitative assessment of the Groundwater Protection Program (GWPP) at the Y-12 National Security Complex (Y-12) in Oak Ridge, TN was performed using the Monitoring and Remediation Optimization System (MAROS) software. This application was previously used as part of a similar quantitative assessment of the GWPP completed in December 2005, hereafter referenced as the 'baseline' MAROS assessment (BWXT Y-12 L.L.C. [BWXT] 2005). The MAROS software contains modules that apply statistical analysis techniques to an existing GWPP analytical database in conjunction with hydrogeologic factors, regulatory framework, and the location of potential receptors, to recommend an improved groundwater monitoring network and optimum sampling frequency for individual monitoring locations. The goal of this supplemental MAROS assessment of the Y-12 GWPP is to review and update monitoring network optimization recommendations resulting from the 2005 baseline report using data collected through December 2007. The supplemental MAROS assessment is based on the findings of the baseline MAROS assessment and includes only the groundwater sampling locations (wells and natural springs) currently granted 'Active' status in accordance with the Y-12 GWPP Monitoring Optimization Plan (MOP). The results of the baseline MAROS assessment provided technical rationale regarding the 'Active' status designations defined in the MOP (BWXT 2006). One objective of the current report is to provide a quantitative review of data collected from Active but infrequently sampled wells to confirm concentrations at these locations. This supplemental MAROS assessment does not include the extensive qualitative evaluations similar to those presented in the baseline report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

March 2008 monitoring results for Centralia, Kansas.

In September 2005, periodic sampling of groundwater was initiated by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) in the vicinity of a grain storage facility formerly operated by the CCC/USDA at Centralia, Kansas. The sampling at Centralia is being performed on behalf of the CCC/USDA by Argonne National Laboratory, in accord with a monitoring program approved by the Kansas Department of Health and Environment (KDHE). The objective is to monitor levels of carbon tetrachloride contamination identified in the groundwater at Centralia (Argonne 2003, 2004, 2005a). Under the KDHE-approved monitoring plan (Argonne 2005b), the groundwater is being sampled twice yearly (for a recommended period of two years) for analyses for volatile organic compounds (VOCs), as well as measurement of selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation (reductive dechlorination) processes in the subsurface environment. The sampling is presently conducted in a network of 10 monitoring wells and 6 piezometers (Figure 1.1), at locations approved by the KDHE (Argonne 2006a). The results of groundwater sampling and VOCs analyses in September-October 2005, March 2006, September 2006, March 2007, and September 2007 were documented previously (Argonne 2006a,b, 2007a, 2008). The results have demonstrated the presence of carbon tetrachloride contamination, at levels exceeding the KDHE Tier 2 Risk-Based Screening Level of 5 {micro}g/L for this compound, in a broad groundwater plume that has shown little movement. This report presents the results of the groundwater sampling at Centralia in March 2008, performed in accord with the KDHE-approved monitoring plan (Argonne 2005b). The September 2007 sampling represented the fifth and final monitoring event performed under the recommended two-year monitoring program approved by the KDHE. The March 2008 sampling begins an extension of the approved monitoring that is to continue until the final site remedy has been implemented and a comprehensive program of performance and compliance monitoring has been established at Centralia (KDHE 2008a).

54 ENVIRONMENTAL SCIENCES↗

Need for an Independent Monitoring of Nuclear Waste Repository: Lessons from WIPP Experience - 18130

The Waste Isolation Pilot Plant (WIPP) is the only operating deep geological repository for the permanent disposal of defense transuranic (TRU) waste in the world. The facility recently resumed waste disposal operations after recovering from a February 2014 accident involving a radiological release from a waste container in the WIPP underground. WIPP had been a DOE success story, operating nearly 15 years with no significant incidents or accidents. Many factors contributed to this success, one of the most important being the overwhelming support exhibited by the local community and the local elected officials. One component of the broad public acceptance by the citizens of Southeast New Mexico has been the concept of independent, third party monitoring of environmental effluents at the site. Independent environmental monitoring ensures a role for the local community in ongoing evaluation of the safety and performance of the site. At WIPP this has been achieved through an independent environmental monitoring program operated by the Carlsbad Environmental Monitoring and Research Center (CEMRC). The CEMRC has been conducting independent environmental monitoring activities on and around the WIPP site since 1991 and makes the results of monitoring activities available and easily accessible to members the general public. The public's free and open access to this data and their direct participation in the CEMRC's whole body counting program provides transparency, which is key to maintaining public trust and confidence. The circumstances following the 2014 radiological release event at WIPP reinforced the value of independent environmental monitoring in order to maintain the high level of transparency necessary for long term local acceptance and support for nuclear facilities. Following what was a minor radiological release event, there were understandably fearful reactions from a number of citizens residing in Carlsbad and the nearby communities of Hobbs, Loving, and Artesia. CEMRC's independent environmental monitoring program and their early public engagement proved invaluable in providing timely and accurate environmental data to local community leaders and members of the general public. The data, and open communication from CEMRC, helped reassure citizens in Carlsbad and the surrounding area that the release was extremely low and the extent was very limited. CEMRC further communicated that the probability of any environmental or health impacts from the release was extremely low. It is unlikely the local community would have placed the same level of trust in similar assurances of safety coming from DOE or other State and Federal regulators. The CEMRC's performance in the days following the release meant the local community had access to independent monitoring data and an independent voice in the dialogue with DOE and state officials that shaped the recovery and eventual re-opening of the WIPP facility. The WIPP radiological release event yielded a plethora of lessons learned that will frame the next phase of operational, oversight, and emergency planning surrounding the facility. In this presentation we will be discussing the value and viability of federally-funded, university-housed independent monitoring programs in maintaining trust of state officials and the local communities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Site Environmental Report for Calendar Year 2007: DOE Operations at The Boeing Company, Santa Susana Field Laboratory, Area IV

This Annual Site Environmental Report (ASER) for 2007 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder components. All nuclear work was terminated in 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. In May 2007, the D&D operations in Area IV were suspended until DOE completes the SSFL Area IV Environmental Impact Statement (EIS). The environmental monitoring programs were continued throughout the year. Results of the radiological monitoring program for the calendar year 2007 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling. All radioactive wastes are processed for disposal at DOE disposal sites and/or other licensed sites approved by DOE for radioactive waste disposal. No liquid radioactive wastes were released into the environment in 2007.

54 ENVIRONMENTAL SCIENCES↗

Site Environmental Report for Calendar Year 2008. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

This Annual Site Environmental Report (ASER) for 2008 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. In May 2007, the D&D operations in Area IV were suspended by the DOE. The environmental monitoring programs were continued throughout the year. Results of the radiological monitoring program for the calendar year 2008 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

Liu, Ning↗

The Swift-BAT Hard X-ray Transient Monitor

The Burst Alert Telescope (BAT) on the Swift satellite is a large field of view instrument that continually monitors the sky to provide the gamma-ray burst trigger for Swift. An average of more than 70% of the sky is observed on a daily basis. The survey mode data is processed on two sets on time scales: from one minute to one day as part of the transient monitor program, and from one spacecraft pointing (approx.20 minutes) to the full mission duration for the hard X-ray survey program. The transient monitor has recently become public through the web site http:// swift.gsfc.nasa.gov/docs/swift/results/transients/. Sky images are processed to detect astrophysical sources in the 15-50 keV energy band and the detected flux or upper limit is calculated for >100 sources on time scales up to one day. Light curves are updated each time that new BAT data becomes available (approx.10 times daily). In addition, the monitor is sensitive to an outburst from a new or unknown source. Sensitivity as a function of time scale for catalog and unknown sources will be presented. The daily exposure for a typical source is approx.1500-3000 seconds, with a 1-sigma sensitivity of approx.4 mCrab. 90% of the sources are sampled at least every 16 days, but many sources are sampled daily. It is expected that the Swift-BAT transient monitor will become an important resource for the high energy astrophysics community.

Krimm, Hans↗

In Situ Monitoring of Groundwater Contamination for Sustainable Remediation Using the Kalman Filter - 18423

Groundwater monitoring is critical for nuclear-related facilities as well as radioactively contaminated sites. Recent advances in sensing, data analytics and simulation capabilities provide substantial opportunities to improve and change current monitoring procedures. In particular, we need a paradigm shift from contaminant-only or compliance-only monitoring programs to comprehensive monitoring, i.e., including other ancillary environmental variables for a holistic understanding of the groundwater systems and plume behaviors. Such new approaches are needed for the effective implementation of sustainable remediation (enhanced and natural attenuation), and they have great potential for cost reduction in site monitoring. This paper reviews recent developments for improving long-term monitoring, with focus on the effective use of in situ sensors, data analytics and simulation capabilities. In particular, we highlight a recent application of the Kalman filter algorithm to estimate contaminant concentrations continuously in real time, based on in-situ measured water quality parameters (e.g. electrical conductance and pH) and sparse groundwater sampling. The results show that we can reduce the groundwater sampling frequency significantly, while capturing the dynamics of short- and long-term contaminant concentration changes. Such advanced and integrated monitoring systems will be beneficial for local residents (e.g., to ensure the safety by detecting adverse events early, enabling a swift response) as well as for site operators (e.g., to gain/improve public acceptance, to be better prepared for litigations and false claims, and to reduce overall monitoring cost). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the IUE program of monitoring the ultraviolet emission line fluxes of four binary systems: HR 1099, 2 Peg, AR Lac and By Dra

A program to obtain IUE spectra and optical photometry and spectra of three RS CVn-type binaries (HR 1099, II Peg, and AR Lac) and the prototype BY Dra system is reported. The systems were monitored for at least one orbital phase, and periodic variations in emission line flux from II Peg and HR 1099, indicative of notational modulation of an active region on these stars were detected. It is found that for II Peg the active region is in phase with photometric minimum as expected, but for HR 1099 ultraviolet emission maximum occurs at the time of photometric maximum.

Marstad, M.↗

Progress in Monitoring Strategies for Risk Reduction in Geologic CO2 Storage

Abstract: This geophysical monitoring review is intended to lay the ground work for an approach to integrating monitoring strategies with risk assessment and risk reduction and to summarize work conducted by U.S. Department of Energy's National Risk Assessment Partnership (NRAP) participants that addresses key questions related to monitoring strategies. Commercial, demonstration and pilot geologic CO2 storage (GCS) projects have provided a wealth of practical experience in monitoring technologies. In this manuscript we review a few key projects, specific geophysical methods, well-based methods, geophysical workflows and some suggested best practices. These practices are often driven and governed by regulatory requirements (e.g. U.S. Environmental Protection Agency [US-EPA] Class VI underground injection regulation) and the need for effective reservoir management of pressures and volumes as well as the site-specific risks to containment, plume migration, and underground sources of drinking water. Reducing uncertainty in monitoring is likely to lead to reducing uncertainty in risk. One of our conclusions is the need for field experiment testing that is risk-driven. It is notable that GCS pilot projects have been designed for safe storage, and to date they have been successful. Technical challenges at all geologic CO2 storage sites include assuring injectivity and capacity predictions are reliable, the fate and subsurface topology of the CO2 plume is acceptable, regulatory permitting and compliance are accomplished in a timely manner, needed business assurances are supported by quantitative technical data, and the storage operation is acceptable to stakeholders. There is risk associated with all of these challenges necessitating a monitoring program utilizing both direct and indirect monitoring methods. Because of the direct association of risk and monitoring in GCS, geophysical monitoring is viewed as a key component in approaching risk assessment. To address monitoring in the context of risk assessment the U.S. Department of Energy's National Risk Assessment Partnership (NRAP) has undertaken a review of work related to monitoring storage sites. In this review we provide a framework for monitoring and then present some specific monitoring tools that may be useful for regulatory compliance, as well as technologies that are applicable to leakage detection.

Harbert, William↗