Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Piezoresistive cantilever array sensor for consolidated bioprocess monitoring

Cellulolytic microbes occur in diverse natural niches and are being screened for industrial modification and utility. A microbe for Consolidated bioprocessing (CBP) development can rapidly degrade pure cellulose and then ferment the resulting sugars into fuels. To identify and screen for novel microbes for CBP, we have developed a piezoresistive cantilever array sensor which is capable of simultaneous monitoring of glucose and ethanol concentration changes in a phosphate buffer solution. 4-mercaptophenylboronic acid (4-MPBA) and polyethyleneglycol (PEG)-thiol are employed to functionalize each piezoresistive cantilever for glucose and ethanol sensing, respectively. Successful concentration measurements of glucose and ethanol with minimal interferences are obtained with our cantilever array sensor.

47 OTHER INSTRUMENTATION↗

On Assessing the Robustness of Structural Health Monitoring Technologies

As Structural Health Monitoring (SHM) continues to gain popularity, both as an area of research and as a tool for use in industrial applications, the number of technologies associated with SHM will also continue to grow. As a result, the engineer tasked with developing a SHM system is faced with myriad hardware and software technologies from which to choose, often adopting an ad hoc qualitative approach based on physical intuition or past experience to making such decisions. This paper offers a framework that aims to provide the engineer with a quantitative approach for choosing from among a suite of candidate SHM technologies. The framework is outlined for the general case, where a supervised learning approach to SHM is adopted, and the presentation will focus on applying the framework to two commonly encountered problems: (1) selection of damage-sensitive features and (2) selection of a damage classifier. The data employed for these problems will be drawn from a study that examined the feasibility of applying SHM to the RAPid Telescopes for Optical Response observatory network.

42 ENGINEERING↗

Filterscopes: Spectral line monitors for long-pulse plasma devices

A photomultiplier (PMT)-based diagnostic system for monitoring spectral lines along multiple viewchords, named the 'Filterscope' [R. J. Colchin et al., Rev. Sci. Instrum. 74, 2068 (2003)], is currently in use at the DIII-D, NSTX, and CDX-U fusion plasma devices in the US, and has been installed at the KSTAR device in Korea. This diagnostic has recently been upgraded for application to long-pulse devices, such as KSTAR, EAST in China, and the future ITER in France. A new data acquisition system, employing the PXI instrumentation platform with an embedded Windows microprocessor controller, can simultaneously record up to 72 channels at 100 kHz sampling rates for plasma periods lasting up to 20 min. Based on the average signal level during an adjustable time interval (100 ms in the present DIII-D implementation), the controller digitally adjusts PMT dynode voltage throughout the course of a discharge, thereby maintaining the output signals at a level where they are neither saturated nor dominated by digitizer noise. The new system's ability to accommodate large variations in source strength, discharge to discharge and within a single discharge, has proved particularly valuable during DIII-D operations, since changes between top, bottom, and double-null divertor magnetic configurations lead to large temporal variations in signal brightness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Radiation Weather Station: Development of a Continuous Monitoring System for the Collection, Analysis, and Display of Environmental Radiation Data

Due to heightened fear surrounding the possibility of future terrorism involving nuclear weapons and radiological dispersive devices, compounded by nonroutine nuclear power plant releases such as from emergencies or accidents, interest in contamination levels of environmental radiation has spiked. This project sought to develop a continuously operational radiation-monitoring system, with graphically visualized data easily accessible to the public. Because this continuing project is housed at a university facility, it bears no connection to perceived political or commercial interests, generally increasing the credibility of the endeavor. Outdoor weather and radiation parameters were gathered by sensors installed on the rooftop of a two-story building. A display and cloud service website was used to project the live data in an understandable format. A correlation was observed between weather and visibly heightened levels of gamma radiation. Furthermore, the goal of this paper is to share and highlight the overall hardware selection and the unique software challenges encountered when developing a robust collection and analysis system, along with the challenges of displaying meteorological and radiological data in a clear and concise fashion.

07 ISOTOPE AND RADIATION SOURCES↗

Autonomy Loops for Monitoring, Operational Data Analytics, Feedback, and Response in HPC Operations

Many High Performance Computing (HPC) facilities have developed and deployed frameworks in support of continuous monitoring and operational data analytics (MODA) to help improve efficiency and throughput. Because of the complexity and scale of systems and workflows and the need for low-latency response to address dynamic circumstances, automated feedback and response have the potential to be more effective than current human-in-the-loop approaches which are laborious and error prone. Progress has been limited, however, by factors such as the lack of infrastructure and feedback hooks, and successful deployment is often site- and case-specific. In this position paper we report on the outcomes and plans from a recent Dagstuhl Seminar, seeking to carve a path for community progress in the development of autonomous feedback loops for MODA, based on the established formalism of similar (MAPE-K) loops in autonomous computing and self-adaptive systems. By defining and developing such loops for significant cases experienced across HPC sites, we seek to extract commonalities and develop conventions that will facilitate interoperability and interchangeability with system hardware, software, and applications across different sites, and will motivate vendors and others to provide telemetry interfaces and feedback hooks to enable community development and pervasive deployment of MODA autonomy loops.

autonomy loops↗

Gravity monitoring of CO{sub 2} movement during sequestration: Model studies

Sequestration/enhanced oil recovery (EOR) petroleum reservoirs have relatively thin injection intervals with multiple fluid components (oil, hydrocarbon gas, brine, and carbon dioxide, or CO{sub 2}), whereas brine formations usually have much thicker injection intervals and only two components (brine and CO{sub 2}). Coal formations undergoing methane extraction tend to be thin (3-10 m) but shallow compared to either EOR or brine formations. Injecting CO{sub 2} into an oil reservoir decreases the bulk density in the reservoir. The spatial pattern of the change in the vertical component of gravity (G{sub z}) is correlated directly with the net change in reservoir density. Furthermore, time-lapse changes in the borehole G{sub z} clearly identify the vertical section of the reservoir where fluid saturations are changing. The CO{sub 2}-brine front, on the order of 1 km within a 20-m-thick brine formation at 1900-m depth with 30% CO{sub 2} and 70% brine saturations, respectively, produced a -10-{mu} Gal surface gravity anomaly. Such an anomaly would be detectable in the field. The amount of CO{sub 2} in a coal-bed methane scenario did not produce a large enough surface gravity response; however, we would expect that for an industrial-size injection, the surface gravity response would be measurable. Gravity inversions in all three scenarios illustrate that the general position of density changes caused by CO{sub 2} can be recovered but not the absolute value of the change. Analysis of the spatial resolution and detectability limits shows that gravity measurements could, under certain circumstances, be used as a lower-cost alternative to seismic measurements.

01 COAL, LIGNITE, AND PEAT↗

Data Report for Monitoring at Six West Virginia Marcellus Shale Development Sites using NETL’s Mobile Air Monitoring Laboratory (July–November 2012)

The West Virginia Department of Environmental Protection’s Office of Oil and Gas was directed according to the Natural Gas Horizontal Well Control Act of December 14, 2011 (West Virginia Code §22-6A) to conduct studies of horizontal well drilling activities related to air quality. The planned study, “Noise, Light, Dust, Volatile Organic Compounds Related to Well Location Restrictions,” required determination of the effectiveness of a 625 ft minimum set-back from the center of the pad of a horizontal well drilling site to the nearest occupied dwelling. An investigation was conducted at seven drilling sites by West Virginia University (WVU) and the National Energy Technology Laboratory (NETL) to collect data on dust, hydrocarbon compounds and on noise, radiation, and light levels. NETL’s role in this study was to collect measurements of ambient pollutant concentrations at six of the seven selected sites using NETL’s Mobile Air Monitoring Laboratory. The trailer-based laboratory was situated a distance of 492–1,312 ft from each well pad, on which activities included well pad construction, vertical drilling, horizontal drilling, hydraulic fracturing, and flaring, with the objective of evaluating the air quality impact of each activity for 1–4 weeks per site. Measured pollutants included volatile organic compounds (VOCs), coarse and fine particulate matter (PM 10 and PM 2.5 , respectively), ozone, methane (CH 4 ), carbon dioxide (CO 2 ), carbon isotopes of CH 4 and CO 2 , organic carbon (OC), elemental carbon (EC), oxides of nitrogen (NOx), and sulfur dioxide (SO 2 ).

03 NATURAL GAS↗

CORROSION MONITORING IN HANFORD NUCLEAR WASTE STORAGE TANKS DESIGN AND DATA FROM 241-AN-102 MULTI-PROBE CORROSION MONITORING SYSTEM

In 2008, a new Multi-Probe Corrosion Monitoring System (MPCMS) was installed in double-shell tank 241-AN-102 on the U.S. Department of Energy's Hanford Site in Washington State. Developmental design work included laboratory testing in simulated tank 241-AN-102 waste to evaluate metal performance for installation on the MPCMS as secondary metal reference electrodes. The MPCMS design includes coupon arrays as well as a wired probe which facilitates measurement of tank potential as well as corrosion rate using electrical resistance (ER) sensors. This paper presents the MPCMS design, field data obtained following installation of the MPCMS in tank 241-AN-102, and a comparison between laboratory potential data obtained using simulated waste and tank potential data obtained following field installation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An all-diamond X-ray position and flux monitor using nitrogen-incorporated ultra-nanocrystalline diamond contacts

Diamond X-ray detectors with conducting nitrogen-incorporated ultra-nanocrystalline diamond (N-UNCD) films as electrodes were fabricated to measure X-ray beam flux and position. Structural characterization and functionality tests were performed for these devices. The N-UNCD films grown on unseeded diamond substrates were compared with N-UNCD films grown on a seeded silicon substrate. Here, the feasibility of the N-UNCD films acting as electrodes for X-ray detectors was confirmed by the stable performance in a monochromatic X-ray beam. The fabrication process is able to change the surface status which may influence the signal uniformity under low bias, but this effect can be neglected under full collection bias.

43 PARTICLE ACCELERATORS↗

In situ monitoring of H and O stable isotopes in soil water reveals ecohydrologic dynamics in managed soil systems [Urban ecohydrologic dynamics revealed by in situ monitoring of H and O stable isotopes in soil water]

The water cycle in urban and hydrologically managed settings is subject to perturbations that are dynamic on small spatial and temporal scales; the effects of which may be especially profound in soils. We deploy a membrane inlet-based laser spectroscopy system in conjunction with soil moisture and temperature sensors to monitor soil water dynamics and H and O stable isotope ratios (δ 2 H and δ 18 O values) in a seasonally irrigated urban-landscaped garden soil over the course of 9 months between the cessation of irrigation in the autumn and the onset of irrigation through the summer. Here, we find that soil water δ 2 H and δ 18 O values predominately reflect seasonal precipitation and irrigation inputs. A comparison of total soil water by cryogenic extraction and mobile soil water measured by in situ water vapor probes reveals that initial infiltration events after long periods of soil drying (the autumn season in this case) emplace water into the soil matrix that is not easily replaced by, or mixed with, successive pulses of infiltrating soil water. Tree stem xylem water H and O stable isotope composition did not match that of available water sources. Our findings suggest that partitioning of soil water into mobile and immobile “pools” and resulting ecohydrologic separation may occur in engineered and hydrologically managed soils and not be limited to natural settings. Furthermore, the laser spectroscopy method detailed here has potential to yield insights in a variety of critical zone and vadose zone studies, potential that is heightened by the simplicity and portability of the system.

07 ISOTOPE AND RADIATION SOURCES↗

In-situ monitoring of flow-permeable surface area of high explosive powder using small sample masses

To ensure good performance of high explosive devices over long periods of time, initiating powders need to maintain their specific surface area within allowed margins during the entire duration of deployment. A common diagnostic used in this context is the Fisher sub-sieve surface area (FSSA). Furthermore, commercial permeametry instruments measuring the FSSA requires the utilization of a sample mass equal to the crystal density of the sample material, an amount that is often one or two orders of magnitude larger than the typical masses found in standard detonator applications. Here we develop a customization of the standard device that can utilize just tens of milligram samples, and with simple calibration yield FSSA values at ac curacy levels comparable to the standard apparatus. This necessitated a newly designed sample holder, made from a material of low coefficient of thermal expansion, which is conveniently transferred between an aging chamber and a re-designed permeametry tube. This improves the fidelity of accelerated aging studies by allowing measurement on the same physical sample at various time - instants during the aging process, and by obviating the need for a potentially FSSA-altering powder re-compaction step. We used the customized apparatus to monitor the FSSA evolution of a number of undoped and homolog-doped PETN powder samples that were subjected to artificial aging for several months at elevated temperatures. These results, in conjunction with an Arrhenius-based aging model were used to assess powder-coarsening - rates under long-term storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Background Gamma Spectrometry for the International Monitoring System

PNNL has developed two very low-background gamma detectors housed in a new shallow underground laboratory. This new capability significantly improves our ability to detect trace amounts of airborne particulate that may be present in samples from the IMS field stations. The detectors were custom ordered to be fabricated using very low background materials. The combination of cosmic veto panels, dry nitrogen gas to reduce radon, low background shielding, and the shallow underground laboratory results in a reduction of the background count rate by a factor of 100 compared to an off –the-shelf commercial gamma detector operating above ground at our laboratory. Detection limits are thus reduced an order of magnitude.

gamma specgtroscopy, lo↗

Monitoring the methanol conversion process in H-ZSM-5 using synchrotron X-ray powder diffraction-mass spectrometry

By monitoring the catalytic conversion of methanol using operando synchrotron powder X-ray diffraction (SXRD) and structure refinement, in combination with theoretical calculations, we demonstrate for the first time, that the concerted associative mechanism is responsible for dimethyl ether production via an activated protonated methanol intermediate species over H-ZSM-5 in an early stage of reaction at 200 °C. The minor contribution from the dissociative mechanism of the adsorbed methoxy intermediate species at Brønsted acid sites, renders their accumulation during the late stage of reaction, which leads to a build-up of the ‘hydrocarbon pool’ and eventually to ‘carbon’ through the formation of C-C bonds.

Lo, Benedict T W.↗