Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Large angle magnetic suspension test fixture

Good progress is being made in several major areas. These include eddy current modelling and analysis, design optimization methods, wind tunnel Magnetic Suspension and Balance Systems (MSBS), payload pointing and vibration isolation systems, and system identification. In addition, another successful International Symposium has been completed, with the Proceedings being printed at the time of writing. These activities continue current work under this Grant and extend previous work on magnetic suspension systems and devices in the Guidance and Control Branch and will permit the demonstration of several new developments in the field of magnetic suspension technology.

Britcher, Colin P.↗

Magnetic suspension system for a laboratory model annular momentum control device

Feasibility of the annular momentum control device (AMCD) for the control and stabilization of spacecraft is presented. The AMCD is momentum storage equipment consisting of a thin rim, magnetically suspended and rotated by noncontacting electromagnetic actuators. The laboratory model AMCD, the rim, and the magnetic suspension system are described, along with their evaluation tests. Because it utilizes permanent magnet flux biased magnetic bearing elements, the original laboratory model magnetic suspension system produced control limitations, and a new suspension system which used zero flux bias was designed and fabricated. Tests of the improved system show that a medium control loop bandwidth is required to achieve stability at low rim velocities, but at higher rim speed the bandwidth of the control loop interacts with bending modes of the rim and causes instability. Decreasing the bandwidth by changing to a precession control mode is discussed, and the results of such a computer simulation are presented.

Groom, N. J.↗

Miniature cyclotron resonance ion source using small permanent magnet

An ion source using the cyclotron resonance principle is described. A miniaturized ion source device is used in an air gap of a small permanent magnet with a substantially uniform field in the air gap of about 0.5 inch. The device and permanent magnet are placed in an enclosure which is maintained at a high vacuum (typically 10 to the minus 7th power) into which a sample gas can be introduced. The ion beam end of the device is placed very close to an aperture through which an ion beam can exit into the apparatus for an experiment.

Anicich, V. G.↗

Paramagnetic-Salt Thermometer With Flux Pump And SQUID's

Paramagnetic-salt low-temperature thermometer incorporates improved superconducting magnetic-flux pump, multiple superconducting quantum interference devices as magnetometers, and feedback stabilization of magnetic flux. Requires much smaller initial magnetizing currents and provides improved temperature resolution via suppression of drift in magnetic induction.

Strayer, Donald M.↗

Large-Area Permanent-Magnet ECR Plasma Source

A 40-cm-diameter plasma device has been developed as a source of ions for material-processing and ion-thruster applications. Like the device described in the immediately preceding article, this device utilizes electron cyclotron resonance (ECR) excited by microwave power in a magnetic field to generate a plasma in an electrodeless (noncontact) manner and without need for an electrically insulating, microwave-transmissive window at the source. Hence, this device offers the same advantages of electrodeless, windowless design - low contamination and long operational life. The device generates a uniform, high-density plasma capable of sustaining uniform ion-current densities at its exit plane while operating at low pressure [<10(exp -4) torr (less than about 1.3 10(exp -2) Pa)] and input power <200 W at a frequency of 2.45 GHz. Though the prototype model operates at 2.45 GHz, operation at higher frequencies can be achieved by straightforward modification to the input microwave waveguide. Higher frequency operation may be desirable in those applications that require even higher background plasma densities. In the design of this ECR plasma source, there are no cumbersome, power-hungry electromagnets. The magnetic field in this device is generated by a permanent-magnet circuit that is optimized to generate resonance surfaces. The microwave power is injected on the centerline of the device. The resulting discharge plasma jumps into a "high mode" when the input power rises above 150 W. This mode is associated with elevated plasma density and high uniformity. The large area and uniformity of the plasma and the low operating pressure are well suited for such material-processing applications as etching and deposition on large silicon wafers. The high exit-plane ion-current density makes it possible to attain a high rate of etching or deposition. The plasma potential is <3 V low enough that there is little likelihood of sputtering, which, in plasma processing, is undesired because it is associated with erosion and contamination. The electron temperature is low and does not vary appreciably with power.

Foster, John E.↗

The Marshall Magnetic Mirror Beam-Plasma Experiment

Plasma propulsion is an advanced propulsion concept with the potential to realize very high specific impulse. Present designs for plasma propulsion devices share a common feature, the incorporation of a magnetic mirror. A magnetic mirror is a plasma confinement scheme whereby charged particles are trapped (or reflected) between two regions of high magnetic field strength. A cylindrical geometry is most often employed to create a magnetic mirror, which is a natural geometry for propulsion devices. To utilize the magnetic mirror configuration in a plasma propulsion device, however, will require efficient coupling of power into the system. With the development of compact and efficient electron sources, such as hollow cathode sources, coupling power into a magnetic mirror using electron beams may be an attractive approach. A system, the Marshall Magnetic Mirror (M3), has been constructed to study the coupling of an electron beam into a magnetic mirror. A description of the M3 device will be provided as well as data from initial beam-plasma coupling experiments.

Schneider, Todd A.↗

Development of a superconductor magnetic suspension and balance prototype facility for studying the feasibility of applying this technique to large scale aerodynamic testing

The basic research and development work towards proving the feasibility of operating an all-superconductor magnetic suspension and balance device for aerodynamic testing is presented. The feasibility of applying a quasi-six-degree-of freedom free support technique to dynamic stability research was studied along with the design concepts and parameters for applying magnetic suspension techniques to large-scale aerodynamic facilities. A prototype aerodynamic test facility was implemented. Relevant aspects of the development of the prototype facility are described in three sections: (1) design characteristics; (2) operational characteristics; and (3) scaling to larger facilities.

Zapata, R. N.↗

Passive Magnetic Bearing

Magnetic bearing for limited rotation devices requires no feedback control system to sense and correct shaft position. Passive Magnetic Torsion Bearing requires no power supply and has no rubbing parts. Torsion wire restrains against axial instability. Magnetic flux geometry chosen to assure lateral stability with radial restoring force that maintains alignment.

Studer, P. A.↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This proposal seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the sensor/actuators. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as the exposure to radiation or infectious agents. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), magnetic particles and metals, and imaging agents. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. These molecules would also be able to administer therapeutics in response to the needs of the astronaut, and act as actuators to remotely manipulate an astronaut as necessary to ensure their safety. The reporting will be accomplished either through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation, or through functional MRI. These nanosensors coupled to NEMS devices could facilitate the success and increase the safety of extended space flight.

Baker, James R., Jr.↗

Contributions of Spherical Harmonics to Magnetic and Gravitational Fields

Gravitational forces are of cardinal importance in the dynamics of spacecraft; magnetic attractions sometime play a significant role also, as was the case with the Long Duration Exposure Facility, and as is now true for the first segment of Space Station Freedom. Both satellites depend on gravitational moment and a device known as a magnetic damper to stabilize their orientation. Magnetic fields are mathematically similar to gravitational fields in one important respect: each can be regarded as a gradient of a potential function that, in turn, can be described as an infinite series of spherical harmonics. Consequently, the two fields can be computed, in part, with quantities that need only be evaluated once, resulting in a savings of time when both fields are needed. The objective of this material is to present magnetic field and gravitational force expressions, and point out the terms that belong to both this is accomplished in Section 1 and 2. Section 3 contains the deductive reasoning with which one obtains the expressions of interest. Finally, examples in Section 4 show these equations can be used to reproduce others that arise in connection with special cases such as the magnetic field produced by a tilted dipole, and gravitational force exerted by an oblate spheroid. The mathematics are discussed in the context of terrestrial fields; however, by substituting appropriate constants, the results can be made applicable to fields belonging to other celestial bodies. The expressions presented here share the characteristics of algorithms set forth for computing gravitational force. In particular, computation is performed speedily by means of recursion formulae, and the expressions do not suffer from the shortcoming of a singularity when evaluated at points that lie on the polar axis.

Roithmayr, Carlos M.↗

Maximum Acceleration Recording Circuit

Coarsely digitized maximum levels recorded in blown fuses. Circuit feeds power to accelerometer and makes nonvolatile record of maximum level to which output of accelerometer rises during measurement interval. In comparison with inertia-type single-preset-trip-point mechanical maximum-acceleration-recording devices, circuit weighs less, occupies less space, and records accelerations within narrower bands of uncertainty. In comparison with prior electronic data-acquisition systems designed for same purpose, circuit simpler, less bulky, consumes less power, costs and analysis of data recorded in magnetic or electronic memory devices. Circuit used, for example, to record accelerations to which commodities subjected during transportation on trucks.

Bozeman, Richard J., Jr.↗

Effect of Alignment on Transport Properties of Carbon Nanotube/Metallic Junctions

Ballistic and spin coherent transport in single walled carbon nanotubes (SWCNT) are predicted to enable high sensitivity single-nanotube devices for strain and magnetic field sensing. Based upon these phenomena, electron beam lithography procedures have been developed to study the transport properties of purified HiPCO single walled carbon nanotubes for development into sensory materials for nondestructive evaluation. Purified nanotubes are dispersed in solvent suspension and then deposited on the device substrate before metallic contacts are defined and deposited through electron beam lithography. This procedure produces randomly dispersed ropes, typically 2 - 20 nm in diameter, of single walled carbon nanotubes. Transport and scanning probe microscopy studies have shown a good correlation between the junction resistance and tube density, alignment, and contact quality. In order to improve transport properties of the junctions a technique has been developed to align and concentrate nanotubes at specific locations on the substrate surface. Lithographic techniques are used to define local areas where high frequency electric fields are to be concentrated. Application of the fields while the substrate is exposed to nanotube-containing solution results in nanotube arrays aligned with the electric field lines. A second electron beam lithography layer is then used to deposit metallic contacts across the aligned tubes. Experimental measurements are presented showing the increased tube alignment and improvement in the transport properties of the junctions.

Wincheski, Buzz↗

Imaging Magnetometer

Imaging magnetometer proposed for scientific, industrial, or military use in detecting underground structures containing magnetic materials and underground machines generating and/or altering magnetic fields. Includes electron-beam tube integrated with phosphor-coated charge-coupled device (CCD). Images formed by magnetic deflection of electron beam. Locations, magnitudes, and directions of identifiable features of magnetic field examined to extract data on locations, sizes, and types of magnetically detected objects.

Moynihan, Philip I.↗

The Rocketdyne Multifunction Tester. Part 1: Test Method

The Rocketdyne Multifunction Tester is a general purpose test apparatus which utilizes axial and radial magnetic bearings as shaft excitation devices. The tester is modular in design so that different seal and bearing packages can be tested on the same test stand. The tester will be used for rotordynamic coefficient extraction, as well as life and fluid/material compatibility evaluations. Use of a magnetic bearing as a shaft excitation device opens up many possibilities for shaft excitation and rotordynamic coefficient extraction. In addition to describing the basic apparatus, some of the excitation and extraction methods are described. Some of the excitation methods to be discussed include random, aperiodic, harmonic, impulse and chirp.

Murphy, Brian T.↗

Magnetic Calorimeter Arrays with High Sensor Inductance and Dense Wiring

We describe prototype arrays of magnetically coupled microcalorimeters fabricated with an approach scalable to very large format arrays. The superconducting interconnections and sensor coils have sufficiently low inductance in the wiring and sufficiently high inductance in the coils in each pixel, to enable arrays containing greater than 4000 sensors and 100,000 X-ray absorbers to be used in future astrophysics missions such as Lynx. We have used projection lithography to create submicron patterns (e.g., 400-nanometer-lines and spaces) in our niobium sensor coils and wiring, integrated with gold-erbium sensor films and gold X-ray absorbers. Our prototype devices will explore the device physics of metallic magnetic calorimeters as feature sizes are reduced to nanoscale.

Magnetism↗

Fabrication of MEMS-Based Microshutter Arrays for Optical Transmission Selection

A MEMS-based programmable aperture mask is under development at the NASA Goddard Space Flight Center. Termed the Microshutter (u-shutter) Array, the device will be used to control the transmission of light, with both high efficiency and contrast, to a multi-object spectrometer on the James Webb Space Telescope. Fabrication of the p-shutter array employs several novel designs and processing techniques. The current generation of micro-shutters consists of 128x64 pixel arrays with unit cell dimensions of 100x200 microns. Shutters are patterned in silicon nitride and sit on a 100 micron silicon frame that is DRIE etched below each shutter. The front and back sides of the device are shown. A magnetic cobalt-iron alloy patterned on top of the shutter allows it to be actuated 90 degrees out-of-plane, into the frame, by an external magnetic field. An electrode on the shutter and a vertical electrode on the sidewall of the frame, approximately 90pm deep, allow them to be electrostatically latched in their rotated position. The vertical electrode is deposited and patterned on the backside of the frame in a single step using a directionally controlled evaporation. Individual addressing of shutters for electrostatic latching is accomplished via a crosspoint addressing scheme, with no on-chip active components. A portion of an array with shutters in the open, latched, and closed positions is shown. Light loss at shutter edges is minimized by an overhanging aluminum light-shield that is anchored to the frame. A photoresist sacrificial layer is used to raise the light-shield up and over the 2 micron gap that surrounds each pixel. After completion, arrays are subjected to life cycle, environmental and optical testing. Fabricated devices have survived 10(exp 6) actuation cycles at both room and cryogenic temperatures and a 14g rms launch-simulation test. Optical testing has shown contrast measurements between open and closed shutters up to 10000:1.

Lynch, Bernard A.↗