Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Cryogenic Pupil Alignment Test Architecture for Aberrated Pupil Images

A document describes cryogenic test architecture for the James Webb Space Telescope (JWST) integrated science instrument module (ISIM). The ISIM element primarily consists of a mechanical metering structure, three science instruments, and a fine guidance sensor. One of the critical optomechanical alignments is the co-registration of the optical telescope element (OTE) exit pupil with the entrance pupils of the ISIM instruments. The test architecture has been developed to verify that the ISIM element will be properly aligned with the nominal OTE exit pupil when the two elements come together. The architecture measures three of the most critical pupil degrees-of-freedom during optical testing of the ISIM element. The pupil measurement scheme makes use of specularly reflective pupil alignment references located inside the JWST instruments, ground support equipment that contains a pupil imaging module, an OTE simulator, and pupil viewing channels in two of the JWST flight instruments. Pupil alignment references (PARs) are introduced into the instrument, and their reflections are checked using the instrument's mirrors. After the pupil imaging module (PIM) captures a reflected PAR image, the image will be analyzed to determine the relative alignment offset. The instrument pupil alignment preferences are specularly reflective mirrors with non-reflective fiducials, which makes the test architecture feasible. The instrument channels have fairly large fields of view, allowing PAR tip/tilt tolerances on the order of 0.5deg.

Bos, Brent↗

Cardiovascular instrumentation for spaceflight

The observation mechanisms dealing with pressure, flow, morphology, temperature, etc. are discussed. The approach taken in the performance of this study was to (1) review ground and space-flight data on cardiovascular function, including earlier related ground-based and space-flight animal studies, Mercury, Gemini, Apollo, Skylab, and recent bed-rest studies, (2) review cardiovascular measurement parameters required to assess individual performance and physiological alternations during space flight, (3) perform an instrumentation survey including a literature search as well as personal contact with the applicable investigators, (4) assess instrumentation applicability with respect to the established criteria, and (5) recommend future research and development activity. It is concluded that, for the most part, the required instrumentation technology is available but that mission-peculiar criteria will require modifications to adapt the applicable instrumentation to a space-flight configuration.

Schappell, R. T.↗

Shutter Mechanism for Calibration of the Cryogenic Diffused Infrared Background Experiment (DIRBE) Instrument

This paper describes the design requirements, the design, the assembly and alignment, and the test program for a shutter mechanism which must operate at cryogenic temperature and draw less than 1.0 milliwatt. The design solution to meet these requirements is a device that positions a mirror with repeated accuracy, has no wearing surfaces and operates at 2.0 K. The unique feature of this device is the simplicity of the mechanism, thus obtaining high reliability.

Tyler, Allen↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument aboard the Terra (EOS AM-11) satellite and has been operating successfully since December 1999. MODIS has been viewing the entire Earth's surface and gathering data to better understand the global dynamics and processes occurring on land, in the oceans, and in the lower atmosphere. All observations are made through an extremely high resolution, optically and mechanically precise, scan mirror motor/encoder assembly. The reliable performance of this assembly depends on two duplex bearing pairs lubricated with Pennzane, a synthetic hydrocarbon, formulated with lead napthanate. This paper describes the results of accelerated and operational life tests. It also describes the post-test analyses of the disassembled bearings. Analyses were performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of the test stations were in very good condition after accumulating 68, 144, and 209 million revolutions, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument aboard the Terra (EOS AM-1) satellite and has been operating successfully since December 1999. MODIS has been viewing the entire Earth's surface and gathering data to better understand the global dynamics and processes occurring on land, in the oceans, and in the lower atmosphere. All observations are made through an extremely high resolution, optically and mechanically precise, scan mirror motor/encoder assembly. The reliable performance of this assembly depends on two duplex bearing pairs lubricated with Pennzane, a synthetic hydrocarbon, formulated with lead napthanate. This paper describes the results of accelerated and operational life tests. It also describes the post-test analyses of the disassembled bearings. Analyses were performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of the test stations were in very good condition after accumulating 68, 144, and 209 million revolutions, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

Surface composition mapping radiometer instrument

The design, development, and fabrication of a three-channel scanning radiometer are discussed. The instrument was flown on Nimbus 5 satellite and measured infrared energy in the 8.3 to 9.3, 10.2 to 11.2, and 0.8 to 1.1 micron spectral regions. The instrument parameters are presented. Theoretical discussions of the instrument subassemblies are provided. Operational details of the mechanical and electrical portions of the instrument are included.

Source record↗

Investigation of Space Based Solid State Coherent Lidar

This report describes the work performed over the period of October 1, 1997 through March 31, 2001. Under this contract, UAH/CAO participated in defining and designing the SPAce Readiness Coherent Lidar Experiment (SPARCLE) mission, and developed the instrument's optical subsystem. This work was performed in collaborative fashion with NASA/MSFC engineers at both UAH/CAO and NASA/MSFC facilities. Earlier work by the UAH/CAO had produced a preliminary top-level system design for the Shuttle lidar instrument meeting the proposed mission performance requirements and the Space Shuttle Hitchhiker canister volume constraints. The UAH/CAO system design efforts had concentrated on the optical and mechanical designs of the instrument. The instrument electronics were also addressed, and the major electronic components and their interfaces defined. The instrument design concept was mainly based on the state of the transmitter and local oscillator laser development at NASA Langley Research Center and Jet Propulsion Laboratory, and utilized several lidar-related technologies that were either developed or evaluated by the NASA/MSFC and UAH/CAO scientists. UAH/CAO has developed a comprehensive coherent lidar numerical model capable of analyzing the performance of different instrument and mission concepts. This model uses the instrument configuration, atmospheric conditions and current velocity estimation theory to provide prediction of instrument performance during different phases of operation. This model can also optimize the design parameters of the instrument.

Amzajerdian, Farzin↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Two high resolution velocity vector analyzers for cosmic dust particles

Methods are described to measure velocities and angles of incidence of charged cosmic dust particles with precisions of about 1 percent and 1 degree, respectively. Both methods employ four one-dimensional position-sensitive detectors in series. The first method utilizes a charge-dividing technique while the second utilizes a time-of-flight technique for determining the position of a particle inside the instrument. The velocity vectors are measured although mechanical interaction between the particle and the instrument is completely avoided. Applications to cosmic dust composition and collection experiments are discussed. The range of radii of measurable particles is from about 0.01 to 100 microns at velocities from 1 to 80 km/s.

Aver, S.↗

Two high resolution velocity vector analyzers for cosmic dust particles

Two new methods are described to measure velocities and angles of incidence of charged cosmic dust particles with precisions of about 1% and 1 deg, respectively. Both methods employ four one-dimensional position-sensitive detectors in series. The first method utilizes a charge-dividing technique while the second utilizes a time-of-flight technique for determining the position of a particle inside the instrument. The velocity vectors are measured although mechanical interaction between the particle and the instrument is completely avoided. Applications to cosmic dust composition and collection experiments are discussed. The range of radii of measurable particles is from about 0.01 to 100 microns at velocities from 1 to 80 km/sec.

Auer, S.↗

Progress Report on the Spacecraft Atmosphere Monitor’s Development Model

The Spacecraft Atmosphere Monitor (S.A.M.) is a miniature gas chromatograph (GC) mass spectrometer (MS) intended for assessing trace volatile organic compounds and the major constituents in the atmosphere of present (the International Space Station) and future crewed spacecraft. As such, S.A.M. will continuously sample concentrations of major air constituents (CH4, H2O, N2, O2, and CO2) and report results in two-second intervals. The S.A.M. is a technology demonstration planned to launch in 2018 and we report here on recent developments taking place in building a testbed and development model of the instrument. The S.A.M. is mechanically designed to operate under hi-G loads present during launch events and can operate at sub-atmospheric pressures relevant to extra-vehicular activities. Total instrument mass is projected at 9.5 kg with power consumption estimated at 35 W. The S.A.M. instrument will provide on-demand reporting on trace volatile organic compounds (VOC) at ppm to ppb levels of 40+ species relevant for astronaut health.

Darrach, M.↗

Preliminary design report, Large Space Telescope OTA/SI Phase B study: High speed area photometer

A photometer is examined which combines several features from separate instruments into a single package. The design presented has both point and area photometry capability with provision for inserting filters to provide spectral discrimination. The electronics provide for photon counting mode for the point detectors and both photon counting and analog modes for the area detector. The area detector also serves as a target locating device for the point detectors. Topics discussed include: (1) electronic equipment requirements, (2) optical properties, (3) structural housing for the instrument, (4) motors and other mechanical components, (5) ground support equipment, and (6) environment control for the instrument. Engineering drawings and block diagrams are shown.

Source record↗

Mechanical strain isolator mount

Certain devices such as optical instruments must preserve their alignmental integrity while being subjected to mechanical strain. A mechanical strain isolator mount is provided to preserve the alignmental integrity of an alignment sensitive instrument. An alignment sensitive instrument is mounted on a rectangular base. Flexural legs are connected at their proximal ends to the rectangular base. Flexural legs are also spaced parallel to the sides. Mounting pads are connected to the legs at the distal end and the mechanical strain isolator mount is attached to the substrate by means of threaded bolts. When a mounting pad and its respective leg is subjected to lateral strain in either the X or Y direction via the substrate, the respective leg relieves the strain by bending in the direction of the strain. An axial strain on a mounting pad in the Z direction is relieved by a rotational motion of the legs in the direction of the strain. When the substrate is stress free, the flexural legs return to their original condition and thus preserve the original alignment integrity of the alignment sensitive instrument.

James, Gordon E.↗

The Geostationary Fourier Transform Spectrometer

The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for an earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. The GeoFTS instrument is a half meter cube size instrument designed to operate in geostationary orbit as a secondary "hosted" payload on a commercial geostationary satellite mission. The advantage of GEO is the ability to continuously stare at a region of the earth, enabling frequent sampling to capture the diurnal variability of biogenic fluxes and anthropogenic emissions from city to continental scales. The science goal is to obtain a process-based understanding of the carbon cycle from simultaneous high spatial resolution measurements of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) many times per day in the near infrared spectral region to capture their spatial and temporal variations on diurnal, synoptic, seasonal and interannual time scales. The GeoFTS instrument is based on a Michelson interferometer design with a number of advanced features incorporated. Two of the most important advanced features are the focal plane arrays and the optical path difference mechanism. A breadboard GeoFTS instrument has demonstrated functionality for simultaneous measurements in the visible and IR in the laboratory and subsequently in the field at the California Laboratory for Atmospheric Remote Sensing (CLARS) observatory on Mt. Wilson overlooking the Los Angeles basin. A GeoFTS engineering model instrument is being developed which will make simultaneous visible and IR measurements under space flight like environmental conditions (thermal-vacuum at 180 K). This will demonstrate critical instrument capabilities such as optical alignment stability, interferometer modulation efficiency, and high throughput FPA signal processing. This will reduce flight instrument development risk and show that the GeoFTS design is mature and flight ready.

Carbon exchanges↗

Ultrafast disruptive probing: Simultaneously keeping track of tens of reaction pathways

Ultrafast science depends on different implementations of the well-known pump–probe method. Here, we provide a formal description of ultrafast disruptive probing, a method in which the probe pulse disrupts a transient species that may be a metastable ion or a transient state of matter. Disruptive probing has the advantage of allowing for simultaneous tracking of the yield of tens of different processes. Our presentation includes a numerical model and experimental data on multiple products resulting from the strong-field ionization of two different molecules, partially deuterated methanol and norbornene. The correlated enhancement and depletion signals between all the different fragmentation channels offer comprehensive information on photochemical reaction pathways. In combination with ion imaging and/or coincidence momentum imaging or as complementary to atom-specific probing or ultrafast diffraction methods, disruptive probing is a particularly powerful tool for the study of strong-field laser–matter interactions.

47 OTHER INSTRUMENTATION↗

An FTIR spectrometer for remote measurements of atmospheric composition

The JPL IV interferometer, and infrared Michelson interferometer, was built specifically for recording high resolution solar absorption spectra from remote ground-based sites, aircraft and from stratospheric balloons. The instrument is double-passed, with one fixed and one moving corner reflector, allowing up to 200-cm of optical path difference (corresponding to an unapodised spectral resolution of 0.003/cm). The carriage which holds the moving reflector is driven by a flexible nut riding on a lead screw. This arrangement, together with the double-passed optical scheme, makes the instrument resistant to the effects of mechanical distortion and shock. The spectral range of the instrument is covered by two liquid nitrogen-cooled detectors: an InSb photodiode is used for the shorter wavelengths (1.85 to 5.5 microns, 1,800 to 5,500/cm) and a HgCdTe photoconductor for the range (5.5 to 15 microns, 650 to 1,800/cm). For a single spectrum of 0.01/cm resolution, which requires a scan time of 105 seconds, the signal/noise ratio is typically 800:1 over the entire wavelength range.

Farmer, C. B.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

This paper describes the results of accelerated and operational life tests on bearings for the Moderate Resolution Imaging Spectroradiometer (MODIS). It also describes the post test analysis of the disassembled bearings. Analysis was performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of three test stations were in very good condition after accumulating 68, 144, and 209 million cycles, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

Testing the Physical Mechanisms of Gamma-Ray Bursts with Multi-Instrument Time-Resolved Spectroscopy

We have continued the project of time-resolved spectral analyses of gamma-ray bursts observed jointly by the BATSE and the Wide-Field Camera on board BeppoSAX. We are making progress understanding the systematic differences between the two data sets. These data comprise the most important joint analysis set for our project. In several meetings, we have reported on metal efforts to understand the blackbody portion of the time series of spectra from GRB970111. Clearly, a fading thermal component can provide a 'seed' spectrum for Compton upscattering. It is very likely the X-ray excess that has been observed previously in BATSE data alone continues into the X-ray band observed by the WFC. We have also made progress in joint fitting of BATSE Large Area Detector and Spectroscopy Detector data with that of the Total Absorption Scintillation Calorimeter (TASC) of the EGRET experiment on CGRO. The TASC data are important to understanding the high-energy response of the BATSE data. We have produced time-sequences of spectra for two important GRB with data from both instruments. The Summer workshop on GRBs at the Aspen Center for Physics provided an opportunity for in-depth discussion of our on-going work. To aid our effort, we continue to make improvements in our spectral analysis software, RMFIT (rewritten from WINGSPAN).

Briggs, Michael S.↗