Search NASA⌕ Search

SEARCH · Search NASA

Results for “Medical operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Obstructive Sleep Apnea Among Army Aircrew

INTRODUCTION: Obstructive sleep apnea (OSA) is a condition characterized by disrupted sleep and excessive daytime fatigue. Associated cognitive and psychomotor decrements pose a threat to aviators’ performance and flight safety. Additionally, the longer term health effects associated with the disease can jeopardize an aviator’s career and negatively impact operational outputs. This study reviews OSA prevalence, related comorbid conditions in Army aviators, and analyzes the aeromedical dispositions of affected individuals. METHODS: The U.S. Army Aeromedical Electronic Resource Office (AERO) database was interrogated for all cases of OSA from June 2005 through June 2015 using ICD-9 code 327.23. Prevalence rates for OSA and other comorbid conditions were then calculated using the total number of aviators in the AERO database. RESULTS: A total of 663 unique instances of OSA were found among the aviator population ( N = 24,568), giving a point prevalence of 2.69%. Four cases affected women. Mean age of initial presentation was 42.62 yr and mean Body Mass Index was 28.69. The top five most prevalent comorbid conditions were hypertension, lumbago, degeneration of a lumbar or lumbosacral intervertebral disc, PTSD, and testicular hypofunction. DISCUSSION: Prevalence of OSA among aviators is lower than the general population but is not uncommon. A positive diagnosis requires a waiver or can result in suspension if not managed effectively, potentially leading to a reduction in aviator numbers. Aggressive health promotion and robust medical surveillance and aeromedical disposition management by the aeromedical community is essential to reduce OSA numbers, maintain aviator health, and maximize flight safety. Goldie C, Stork B, Bernhardt K, Gaydos SJ, Kelley AM. Obstructive sleep apnea among army aircrew . Aerosp Med Hum Perform. 2022; 93(5):415–420.

Biophysics↗

Visible-to-THz near-field nanoscopy

Optical microscopy has a key role in research, development and quality control across a wide range of scientific, technological and medical fields. However, diffraction limits the spatial resolution of conventional optical instruments to about half the illumination wavelength. A technique that surpasses the diffraction limit in the wide spectral range between visible and terahertz frequencies is scattering-type scanning near-field optical microscopy (s-SNOM). The basis of s-SNOM is an atomic force microscope in which the tip is illuminated with light from the visible to the terahertz spectral range. By recording the elastically tip-scattered light while scanning the sample below the tip, s-SNOM yields near-field optical images with a remarkable resolution of 10 nm, simultaneously with the standard atomic force microscopic topography image. This resolution is independent of the illumination wavelength, rendering s-SNOM a versatile nanoimaging and nanospectroscopy technique for fundamental and applied studies of materials, structures and phenomena. This Review presents an overview of the fundamental principles governing the measurement and interpretation of near-field contrasts and discusses key applications of s-SNOM. We also showcase emerging developments that enable s-SNOM to operate under various environmental conditions, including cryogenic temperatures, electric and magnetic fields, electrical currents, strain and liquid environments. Furthermore, all these recent developments broaden the applicability of s-SNOMs for exploring fundamental solid-state and quantum phenomena, biological matter, catalytic reactions and more.

Hillenbrand, Rainer [CIC nanoGUNE BRTA and Departm↗

A Novel N Staging System for Predicting Survival in Patients with Medullary Thyroid Cancer

Introduction: Despite the crucially prognostic value of lymph node metastasis (LNM) in patients with medullary thyroid cancer (MTC), only the LNM compartment alone was reflected in the 8th edition of the American Joint Committee on Cancer (AJCC) system. Objective: This study aimed to incorporate the metastatic lymph node number and metastatic lymph node ratio to generate a more accurate and appropriate N staging system for patients with MTC based on recursive partitioning analysis. Design, Setting, and Patients: Two cohorts were included in the analysis, including 1374 MTC patients from the Surveillance, Epidemiology, and End Results database as the derivation cohort, and 164 patients from Fudan University Shanghai Cancer Center as the validation cohort. The predictive performance of the alternative proposed N staging system was compared with that of the 8th AJCC system by using the Harrell concordance index (C-index) and the area under the receiver operating characteristic curve (AUC). Results: In the derivation cohort, the C-index and the AUC at 10 years were 0.778 and 0.789, respectively, for the novel N staging system, and 0.749 and 0.741, respectively, for the 8th AJCC N staging system. Similar trends were also observed in the validation cohort. The proposed N staging system had a better prognostic performance. Conclusion: With some improvements, the novel N staging system for MTC suggested from this research may be assessed for potential adoption in the next edition of the AJCC N staging system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resilient GaN-based Power Module with Improved Diagnostic for Future Accelerator

Los Alamos Neutron Science Center (LANSCE) and Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) play a pivotal role in advancing scientific research and national security initiatives. As a premier facility for neutron science, LANSCE and DARHT provide invaluable insights into fundamental research, materials science, nuclear physics, high-energy physics, material science, and medical imaging. Existing (DC) power supply and pulse modulation technologies used in LANSCE and DARHT face limitations in terms of reliability, maintainability, and diagnostics which hinder the progress of these cutting-edge facilities. By proposing improvements to LANL accelerator facilities’ performance and addressing component failure, we aim to enhance scientific outcomes and minimize disruptions, allowing for more efficient and productive research activities while ensuring the continuity of valuable contributions to the user community. This proposal aims to revolutionize (DC) power supply and pulse power systems for future particle accelerators via the development of a resilient GaN-based power module with improved diagnostic and redundant submodules.

43 PARTICLE ACCELERATORS↗

Flow Measurements in Pressurized Helium Gas Cooling Channels: Rev. 1

Compressed helium gas is used to cool the NorthStar Medical Radioisotope (NMR) target system, also called the trident, chosen due to its superior heat transfer capabilities and its inability to react with Molybdenum-100 (Mo-100) during irradiation. To test the housing and NMR target stack at Los Alamos National Laboratory (LANL), two sets of helium gas flow loop facilities have been set-up and tested. One system is used for bench-top experiments to systematically investigate individual components of the NMR target, and the other, larger system is more representative of the system at NMR and is used for testing the full NMR target stack.

43 PARTICLE ACCELERATORS↗

Coupling a recurrent neural network to SPAD TCSPC systems for real-time fluorescence lifetime imaging

Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. Inspired by the concept of Edge Artificial Intelligence (Edge AI), we propose a robust approach that enables fast FLI with no degradation of accuracy. This approach couples a recurrent neural network (RNN), which is trained to estimate the fluorescence lifetime directly from raw timestamps without building histograms, to SPAD TCSPC systems, thereby drastically reducing transfer data volumes and hardware resource utilization, and enabling real-time FLI acquisition. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in the presence of background noise by a large margin. To explore the ultimate limits of the approach, we derive the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. To demonstrate real-time operation, we build a FLI microscope based on an existing SPAD TCSPC system comprising a 32 x 32 SPAD sensor named Piccolo. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on the Xilinx Kintex-7 FPGA that controls the Piccolo. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications, including biological imaging, biomedical diagnostics, and fluorescence-assisted surgery, etc.

47 OTHER INSTRUMENTATION↗

Niowave Neutron Source Converter: Lead-Bismuth-Eutectic (LBE) Windowless Target Design and Evaluation

Los Alamos National Laboratory (LANL) is working with Niowave on the design and evaluation of their lead-bismuth-eutectic (LBE) windowless target (i.e., neutron source converter). Niowave plans to use 200 kW electron beam at 40 MeV beam energy to produce neutrons by photonuclear reaction with LBE. Then, the neutrons undergo fission at the surrounding uranium target assembly (UTA) to produce Molybdenum 99 (Mo-99) as a fission product, which eventually decays to Technetium-99 (Tc-99m). Tc-99m is one of important radioisotopes that is used for medical diagnostics. LANL conducted 3D multiphysics analysis for the Niowave neutron converter design and provided design assessment in thermohydraulic aspects. LANL conducted radiation transport calculations using Monte-Carlo N-Particle (MCNP) code with unstructured meshing scheme. The 3D volumetric heating profiles in the LBE and Stainless-Steel (SS) housing were imported into multiphase computational fluid dynamics (CFD) to obtain 3D temperature profiles of LBE and SS through conjugate heat transfer (CHT) analysis. The key findings are: LBE film thickness at the center of the beam is approximately 1.6 cm with a maximum LBE velocity of approximately 1.8 m/s, which is below a 2 m/s limit to avoid erosion issues on supporting structures; Heat deposition in the LBE peaks at ~1 cm depth from the LBE free-surface because of the forward interactions of electron, photon, and neutron with LBE; LBE maximum temperature is ~360 °C, which is below LBE evaporation initiative temperature, ~450 °C; LBE-SS interface temperature is ~350 °C, which is below the safety thermal limit to prevent severe corrosion on SS. The results indicate that Niowave’s neutron converter design satisfies both hydraulic and thermal criteria for safe operation. By virtue of such computational analysis, Niowave can move toward establishing an experimental setup to experimentally test their LBE neutron converter. The following sections describe the detailed work done by LANL.

43 PARTICLE ACCELERATORS↗

A Simulation Modeling Approach to Optimizing Nuclear Waste Dispositioning

The dispositioning of nuclear waste generated at facilities across the country is an ongoing battle that affects us all. National laboratories and research centers dealing in medical research, clean energy, and other nuclear activities such as the Department of Energy (DOE) facilities face the need to properly manage and dispose of nuclear waste. A dynamic modeling solution would enable the DOE and others to make decisions on waste disposal and technological options. In doing so, this research explores modeling techniques using available data to address these situations. The focus being on developing an initial robust and adaptable discrete event model using the ExtendSim tool. This modeling effort will target the dispositioning of transuranic waste at the Savannah River National Laboratory (SRNL) which can be expanded to represent the current state of disposition process for waste generated at other DOE facilities. The model aims to assess resource allocation and waste processing options to stabilize productivity and cut the backlog of nuclear waste. By assessing the results of different scenarios, this research aims to provide actionable insights for the DOE. This approach has the potential to significantly improve the management of radioactive waste, offering the capability of evaluating options for optimizing the process for nuclear waste disposal. The findings of this study can serve as a valuable resource for decision-makers and other national laboratories, or research entities engaged in nuclear operations by enabling them to make more informed choices.

Andaverde, Alexis↗

Diagnosis, management, and follow-up of upper tract urothelial carcinoma: an interdisciplinary collaboration between urology and radiology

Upper tract urothelial carcinoma (UTUC) is a common and lethal malignancy. Patients diagnosed with this illness often face invasive workups, morbid therapies, and prolonged post-operative surveillance. UTUC represents approximately 5–10% of urothelial malignancies in the United States and affect 4600–7800 new patients annually. Various environmental exposures as well as smoking have been implicated in the development of UTUC. The diagnosis and workup of UTUC relies on heavily on imaging studies, a close working relationship between Urologists and Radiologists, and invasive procedures such as ureteroscopy. Treatments range from renal-sparing endoscopic surgery to radical extirpative surgery depending on the specific clinical situation. Follow-up is crucial as UTUC has a high recurrence rate. Here we review the epidemiology, diagnosis, management strategies, and follow-up of UTUC from an interdisciplinary perspective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compact, high-power superconducting radio-frequency accelerators for environmental applications

Electron-beam irradiation has been proven to destructively reduce or eliminate a wide variety of organic chemicals, viruses and bacteria from wastewater, as well as reducing sulfur and nitrous oxides emission from coal-fired power plants. It is estimated that there are approximately 30,000 such particle accelerators in use worldwide for industrial processes including surface and bulk processing of material, medical sterilization, and environmental remediation. Maximum beam power from accelerators used in these applications is currently limited to less than 500 kW, and a higher beam power is needed to reduce treatment costs. The market availability of continuous-wave (CW) electron-beam accelerators with power of the order of ~100 kW is also very limited. Superconducting radio-frequency (SRF) linear accelerators (linacs) are commonly used at basic research laboratories throughout the world due to their exceptionally high efficiency as compared to current industrial varieties. Recent advances in cryogenics, SRF thin films and high-power magnetrons allow for the design of increasingly compact and efficient CW SRF electron linacs in the energy range 1-10 MeV, with up to 1 MW of beam power. A new class of compact, high-efficiency electron-beam accelerators may provide cost-effective solutions for a range of industrial and environmental remediation applications, particularly with respect to tackling one such class of contaminants so-called “forever chemicals”, including per- and polyfluoroalkyl substances (PFASs), which are ubiquitous in a wide range of products and for which there is currently no effective destruction technology. We have recently demonstrated the key technologies required for such accelerators by: 1) operating a Nb3Sn SRF accelerating cavity cooled by commercial cryocoolers up to an accelerating gradient of 12.4 MV/m and 2) demonstrating the phase-locking as well as a high-efficiency power combining scheme for industrial magnetron transmitters. In this presentation, we will introduce the principles and benefits of MW-class SRF linacs, based on the conduction-cooled SRF technology that we have demonstrated for environmental remediation. We propose the development of a 4 MeV, 20 kW prototype to be built at Jefferson Lab as a first accelerator demonstrator unit. We will also present the results from samples study on the effect of electron-beam irradiation on so-called “forever chemicals” such as 1,4-dioxane and PFAS, using an existing multi-purpose 10 MeV, low-power, CW SRF linac at Jefferson Lab.

Ciovati, Gianluigi↗

Optimization and Multimachine Learning Algorithms to Predict Nanometal Surface Area Transfer Parameters for Gold and Silver Nanoparticles

Interactions between gold metallic nanoparticles and molecular dyes have been well described by the nanometal surface energy transfer (NSET) mechanism. However, the expansion and testing of this model for nanoparticles of different metal composition is needed to develop a greater variety of nanosensors for medical and commercial applications. In this study, the NSET formula was slightly modified in the size-dependent dampening constant and skin depth terms to allow for modeling of different metals as well as testing the quenching effects created by variously sized gold, silver, copper, and platinum nanoparticles. Overall, the metal nanoparticles followed more closely the NSET prediction than for Förster resonance energy transfer, though scattering effects began to occur at 20 nm in the nanoparticle diameter. To further improve the NSET theoretical equation, an attempt was made to set a best-fit line of the NSET theoretical equation curve onto the Au and Ag data points. An exhaustive grid search optimizer was applied in the ranges for two variables, 0.1≤C≤2.0 and 0≤α≤4, representing the metal dampening constant and the orientation of donor to the metal surface, respectively. Three different grid searches, starting from coarse (entire range) to finer (narrower range), resulted in more than one million total calculations with values C=2.0 and α=0.0736. The results improved the calculation, but further analysis needed to be conducted in order to find any additional missing physics. With that motivation, two artificial intelligence/machine learning (AI/ML) algorithms, multilayer perception and least absolute shrinkage and selection operator regression, gave a correlation coefficient, R2, greater than 0.97, indicating that the small dataset was not overfitting and was method-independent. This analysis indicates that an investigation is warranted to focus on deeper physics informed machine learning for the NSET equations.

Demers, Steven M. E. (ORCID:0000000192213246)↗

First-principles Modeling and Design of Solid-State Interfaces for the Protection and Use of Lithium Metal Anodes

Li-ion batteries are one of the most advanced energy storage technologies in use today. Li-ion batteries are used in a multitude of applications ranging from consumer electronics, medical devices, sensors and grid storage. However, improving the capacity and energy density delivered by current Li-ion technology requires advanced materials research into novel chemical systems. In this project we have focused particularly in the use of solid-state electrolytes with lithium metal electrodes. Research into all solid-state batteries (ASSB) with Li metal electrodes has significantly expanded in recent years, however most studies reported experimental findings, which left substantial room for theoretical and modeling work as a tool to understand and determine design principles allowing reliable and safe use of ASSBs with Li metal. Among the remaining obstacles preventing reliable use of ASSBs with a Li metal electrode, the stability of the interface between the solid electrolyte and Li metal, and the propagation/dendrite formation of Li metal and resulting mechanical degradation of the electrolyte are key phenomenon that are yet to be fully understood. In the current project we have addressed these two coupled phenomena using first principles calculations and mesoscale continuum modeling. We have obtained chemical and electrochemical stability windows for several solid electrolyte materials. Additionally, from mathematical and numerical modeling of Li protrusion and dendrite initiation during plating and stripping we have determined design criteria in terms of chemical, electrochemical, and mechanical properties and operating conditions for which stable deposition can occur. We also considered the effects of mixed electronic-ionic conduction in solid electrolytes, which has more recently been suggested as another important mechanism involved in ASSB failure. Throughout our work we have successfully addressed important questions necessary for the use of ASSB’s. We have determined guiding principles for materials properties and operating conditions necessary to operate ASSB’s. And have proposed novel solid electrolyte materials with predicted chemical stability an ionic conductivity. Although this represents significant progress in our understanding, open questions remain in order to fully develop reliable and safely operate ASSBs with Li metal. Future work, building on this project will require further experimental, theoretical and simulation efforts to address remaining questions.

25 ENERGY STORAGE↗

Plasmonic photoconductive terahertz focal-plane array with pixel super-resolution

Abstract Imaging systems operating in the terahertz part of the electromagnetic spectrum are attractive due to their ability to penetrate many opaque materials and provide unique spectral signatures of various chemicals. However, the use of terahertz imagers in real-world applications has been limited by the slow speed, large size, high cost and complexity of present systems, largely due to the lack of suitable terahertz focal-plane array detectors. Here we report a terahertz focal-plane array that can directly provide the spatial amplitude and phase distributions, along with the ultrafast temporal and spectral information of an imaged object. It consists of a two-dimensional array of ~0.3 million plasmonic photoconductive nanoantennas optimized to rapidly detect broadband terahertz radiation with a high signal-to-noise ratio. We utilized the multispectral nature of the amplitude and phase data captured by these plasmonic nanoantennas to image different objects, including super-resolved etched patterns in a silicon substrate and defects in battery electrodes. By eliminating the need for raster scanning and spatial terahertz modulation, our terahertz focal-plane array offers more than a 1,000-fold increase in the imaging speed compared with the state of the art and potentially suits a broad range of applications in industrial inspection, security screening and medical diagnosis, among others.

Optics↗

Enhancing the solubility of SARS-CoV-2 inhibitors to increase future prospects for clinical development

SARS-CoV-2 poses an ongoing threat to human health as variants continue to emerge. Several effective vaccines are available, but a diminishing number of Americans receive the updated vaccines (only 22% received the 2023 update). Public hesitancy towards vaccines and common occurrence of “breakthrough” infections (i.e., infections of vaccinated individuals) highlight the need for alternative methods to reduce viral transmission. SARS-CoV-2 enters cells by fusing its envelope with the target cell membrane in a process mediated by the viral spike protein, S. The S protein operates via a Class I fusion mechanism in which fusion between the viral envelope and host cell membrane is mediated by structural rearrangements of the S trimer. We previously reported lipopeptides derived from the C-terminal heptad repeat (HRC) domain of SARS-CoV-2 S that potently inhibit fusion by SARS-CoV-2, both in vitro and in vivo. These lipopeptides bear an attached cholesterol unit to anchor them in the membrane. Here, to improve prospects for experimental development and future clinical utility, we employed structure-guided design to incorporate charged residues at specific sites in the peptide to enhance aqueous solubility. This effort resulted in two new, potent lipopeptide inhibitors.

36 MATERIALS SCIENCE↗

Enhancing Radionuclide Production Capabilities at the Duke University Medical Center Cyclotron with a Focus on Astatine-211

Radionuclides play an important role in a diverse array of fields including physics, chemistry, agriculture, materials science, national security, medical research and patient care. Establishing a reliable domestic supply of key radionuclides is critical to our national competitiveness in these areas. Regarding medical applications, targeted alpha-particle therapy (TAT) has become of great interest to basic researchers and clinicians alike and is emerging as a valuable and cost-effective approach for cancer treatment. Unfortunately, progress in TAT, particularly with regard to its clinical translation, has been severely hampered by the limited availability of the most promising radionuclides at a reasonable cost, and with appropriate chemical and radiochemical purity. In this project, we have attempted to address this problem by focusing on production of the 7.2-h half-life α-particle emitter, 211 At, which has long been considered to be one of the most promising radionuclides for TAT. We note that he critical importance of improving the supply of 211 At in the United States was noted in the Funding Opportunity Announcement related to this project. At Duke University, we have a CS-30 cyclotron that is one of the few accelerators in the United States that has an alpha-particle beam that has enough energy to make useful quantities of 211 At. With this cyclotron, we have been able to produce more 211 At than anywhere else in the world because of our unique internal cyclotron target system. However, the CS-30 cyclotron is nearly 40 years old and was no longer reliable. In addition, its operation required considerable skill, largely because it had analog control systems, and vital parts including old-fashioned power supplies, were becoming unavailable. For these reasons, the current project was undertaken to evaluate all the subsystems of the CS-30 cyclotron and replace, repair, and update them. With help from our consultant, Ionetix, this has now been accomplished. We believe that because of this work, the CS-30 can reliably supply 211 At for basic research and clinical trials both at Duke and beyond.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NaroNet: Discovery of tumor microenvironment elements from highly multiplexed images

Understanding the spatial interactions between the elements of the tumor microenvironment -i.e. tumor cells. fibroblasts, immune cells- and how these interactions relate to the diagnosis or prognosis of a tumor is one of the goals of computational pathology. We present NaroNet, a deep learning framework that models the multi-scale tumor microenvironment from multiplex-stained cancer tissue images and provides patient-level interpretable predictions using a seamless end-to-end learning pipeline. Trained only with multiplex-stained tissue images and their corresponding patient-level clinical labels, NaroNet unsupervisedly learns which cell phenotypes, cell neighborhoods, and neighborhood interactions have the highest influence to predict the correct label. To this end, NaroNet incorporates several novel and state-of-the-art deep learning techniques, such as patch-level contrastive learning, multi-level graph embeddings, a novel max-sum pooling operation, or a metric that quantifies the relevance that each microenvironment element has in the individual predictions. We validate NaroNet using synthetic data simulating multiplex-immunostained images where a patient label is artificially associated to the -adjustable- probabilistic incidence of different microenvironment elements. We then apply our model to two sets of images of human cancer tissues: 336 seven-color multiplex-immunostained images from 12 high-grade endometrial cancer patients; and 382 35-plex mass cytometry images from 215 breast cancer patients. In both synthetic and real datasets, NaroNet provides outstanding predictions of relevant clinical information while associating those predictions to the presence of specific microenvironment elements.

60 APPLIED LIFE SCIENCES↗

National Emission Standards for Hazardous Air Pollutants – Radionuclide Emissions Calendar Year 2020

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and the North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. Radionuclides in air from NNSS activities have been monitored since the initiation of atmospheric testing. After 1962, testing was limited to underground detonations, which greatly reduced radiation exposure to the public. Since the end of nuclear testing in 1992, radiation monitoring has focused on detecting airborne radionuclides from historically contaminated soils because this sources dominates the potential offsite dose. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of manmade radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP), specifically the National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities (40 CFR 61, Subpart H, 2020) limits the release of radioactivity from a DOE facility to that which would cause 10 millirem per year (mrem/y) effective dose equivalent (EDE) to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as Japan’s Fukushima nuclear power plant, which was damaged in 2011. NNSA/NFO demonstrates compliance with the NESHAP limit by reporting environmental measurements of radionuclide air concentrations at critical receptor locations on the NNSS. This alternative was proposed and formerly submitted to the U.S. Environmental Protection Agency (EPA) in 2001 (EPA 2001a) and has been the method used to demonstrate compliance with the 40 CFR 61.92 dose standard since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are closer to radionuclide releases than where the public resides so they act as protective substitutes for public receptor locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Level (CL) for Environmental Compliance listed in Table 2 of 40 CFR 61, Appendix E. For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. The EPAapproved air transport model, called the Clean Air Package 1988 (CAP88-PC) is also used to calculate the effective dose equivalent to the maximally exposed individual from NNSS air emissions. CAP88-PC was also used to calculate the population dose, or the collective EDE (expressed as person-rem [roentgen equivalent man] per year [person-rem/y]) for all individuals combined who reside within 80 kilometers (km) of NNSS emission sources. In 2020, the potential dose from radiological emissions to air from both current and past NNSS activities was well below the 10 mrem/y dose limit. This is demonstrated by both the air sampling data collected at critical receptor air monitoring stations and CAP88-PC modeling. The average concentrations of radioactivity at air critical receptor stations ranged from 0.2% to a maximum of 4.2% of the allowed NESHAP limit. CAP88-PC modeling of all 2020 NNSS radionuclide emissions showed the maximally exposed individual to be in Amargosa Valley and this individual received a potential dose of 0.063 mrem/y. The collective dose was calculated to be 0.29 person-rem/year for the 521,300 people who lived within 80 km of NNSS emission sources.

99 GENERAL AND MISCELLANEOUS↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗