Search NASA⌕ Search

SEARCH · Search NASA

Results for “Michelson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Amplitude and intensity spatial interferometry; Proceedings of the Meeting, Tucson, AZ, Feb. 14-16, 1990

Attention is given to such topics as ground interferometers, space interferometers, speckle-based and interferometry-based astronomical observations, adaptive and atmospheric optics, speckle techniques, and instrumentation. Particular papers are presented concerning recent progress on the IR Michelson array; the IOTA interferometer project; a space interferometer concept for the detection of extrasolar earth-like planets; IR speckle imaging at Palomar; optical diameters of stars measured with the Mt. Wilson Mark III interferometer; the IR array camera for interferometry with the cophased Multiple Mirror Telescope; optimization techniques appliesd to the bispectrum of one-dimensional IR astronomical speckle data; and adaptive optical iamging for extended objects.

Breckinridge, Jim B.↗

Optical diameters of stars measured with the Mt. Wilson Mark III interferometer

Reliable stellar angular diameters can now be determined using the Mark III Optical Interferometer located on Mt. Wilson, California. The Mark III is a Michelson Interferometer capable of measuring the interferometric fringe visibility for stars using interferometer baselines varying from 3 to 31.5 meters in length. Angular diameters measured with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm.

Simon, R. S.↗

Multiplex Fabry-Perot interferometer

Attention is given to a Fabry-Perot interferometer (FPI) technique in which one of the etalon plates is moved over a large optical distance while the other remains fixed, thus exploiting the multiplex advantage of the instrument. This technique involves the application of Fourier-transform spectrometer to the multiple harmonics passing through the FPI etalon. It is shown that the multiplex FPI acts as several Michelson interferometers working at the same time, over the same spectral interval, and at different spectral resolutions. A high spectral resolution has been obtained over a large wavenumber interval, while the advantage of a reasonable scan length has been retained.

Hays, Paul B.↗

Infrared spectroscopic remote sensing from the Cassini orbiter

An infrared spectroscopy instrument for infrared remote sensing from the Cassini orbiter is being breadboarded in the laboratory. The Composite Infrared Spectrometer (CIRS) consists of a pair of Fourier Transform Spectrometers (FTS) which together cover the range from 10 - 1400/cm with a spectral resolution up to 0.5/cm. The far-infrared FTS is a polarizing interferometer covering the 10 - 300/cm range. The mid-infrared FTS is a conventional Michelson FTS covering 200 - 1400/cm in three spectral channels. CIRS will retrieve information on the atmospheres of Titan and Saturn with good vertical resolution, from deep in their tropospheres to high in their stratospheres, and into the upper few centimeters of the regoliths of icy objects. The science objectives and design of CIRS are discussed.

Kunde, V.↗

Thermal emission spectroscopy of the middle atmosphere

The general objective of this research is to obtain, via remote sensing, simultaneous measurements of the vertical distributions of stratospheric temperature, ozone, and trace constituents that participate in the catalytic destruction of ozone (NO(sub y): NO, NO2, NO3, HNO3, ClONO2, N2O5, HNO4; Cl(sub x): HOCl), and the source gases for the catalytic cycles (H2O, CH4, N2O, CF2Cl2, CFCl3, CCl4, CH3Cl, CHF2Cl, etc.). Data are collected during a complete diurnal cycle in order to test our present understanding of ozone chemistry and its associate catalytic cycles. The instrumentation employed is an emission-mode, balloon-borne, liquid-nitrogen-cooled Michelson interferometer-spectrometer (SIRIS), covering the mid-infrared range with a spectral resolution of 0.020 cm(exp -1). Cryogenic cooling combined with the use of extrinsic silicon photoconductor detectors allows the detection of weak emission features of stratospheric gaseous species. Vertical distributions of these species are inferred from scans of the thermal emission of the limb in a sequence of elevation angles. The fourth SIRIS balloon flight was carried out from Palestine, Texas on September 15-16, 1986 with 9 hours of nighttime data (40 km). High quality data with spectral resolution 0.022 cm(exp -1), were obtained for numerous limb sequences. Fifteen stratospheric species have been identified to date from this flight: five species from the NO(sub y) family (HNO3, NO2, NO, ClONO2, N2O5), plus CO2, O3, H2O, N2O, CH4, CCl3F, CCl2F2, CHF2Cl, CF4, and CCl4. The nighttime values of N2O5, ClONO2, and total odd nitrogen have been measured for the first time, and compared to model results. Analysis of the diurnal variation of N2O5 within the 1984 and 1986 data sets, and of the 1984 ClONO2 measurements, were presented in the literature. The demonstrated ability of SIRIS to measure all the major NO(sub y) species, and therefore to determine the partitioning of the nitrogen family over a continuous diurnal cycle, is a powerful tool in the verification and improvement of photochemical modeling.

Kunde, V. G.↗

Stratospheric constituent distributions from balloon-based limb thermal emission measurements

This research task deals with an analysis of infrared thermal emission observations of the Earth's atmosphere for determination of trace constituent distributions. Infrared limb thermal emission spectra in the 700-2000 cm(exp -1) region were obtained with a liquid nitrogen cooled Michelson interferometer-spectrometer (SIRIS) on a balloon flight launched from Palestine, Texas, at nighttime on September 15-16, 1986. An important objective of this work is to obtain simultaneously measured vertical mixing ratio profiles of O3, H2O, N2O, NO2, N2O5, HNO3 and ClONO2 and compare with measurements made with a variety of techniques by other groups as well as with photochemical model calculations. A portion of the observed spectra obtained by SIRIS from the balloon flight on September 15-16, 1986, has been analyzed with a focus on calculation of the total nighttime odd nitrogen budget from the simultaneously measured profiles of important members of the NO(sub x) family. The measurements permit first direct determination of the nighttime total odd nitrogen concentrations NO(sub y) and the partitioning of the important elements of the NO(sub x) family.

Abbas, Mian M.↗

EPR experiment and 2-photon interferometry: Report of a 2-photon interference experiment

After a very brief review of the historical Einstein, Podolsky, and Rosen (EPR) experiments, a new two-photon interference type EPR experiment is reported. A two-photon state was generated by optical parametric down conversion. Pairs of light quanta with degenerate frequency but divergent directions of propagation were sent to two independent Michelson interferometers. First and second order interference effectors were studied. Different than other reports, we observed that the second order interference visibility vanished when the optical path difference of the interferometers were much less than the coherence length of the pumping laser beam. However, we also observed that the second order interference behaved differently depending on whether the interferometers were set at equal or different optical path differences.

Shih, Y. H.↗

Nonlinear optical polymers for electro-optic signal processing

Photonics is an emerging technology, slated for rapid growth in communications systems, sensors, imagers, and computers. Its growth is driven by the need for speed, reliability, and low cost. New nonlinear polymeric materials will be a key technology in the new wave of photonics devices. Electron-conjubated polymeric materials offer large electro-optic figures of merit, ease of processing into films and fibers, ruggedness, low cost, and a plethora of design options. Several new broad classes of second-order nonlinear optical polymers were developed at the Navy's Michelson Laboratory at China Lake, California. Polar alignment in thin film waveguides was achieved by electric-field poling and Langmuir-Blodgett processing. Our polymers have high softening temperatures and good aging properties. While most of the films can be photobleached with ultraviolet (UV) light, some have excellent stability in the 500-1600 nm range, and UV stability in the 290-310 nm range. The optical nonlinear response of these polymers is subpicosecond. Electro-optic switches, frequency doublers, light modulators, and optical data storage media are some of the device applications anticipated for these polymers.

Lindsay, Geoffrey A.↗

Thermal expansion behavior of LDEF metal matrix composites

The effects of the space environment on the thermal expansion stability of metal matrix composites (graphite/Al and graphite/Mg) will be presented. A sample from each category of metal matrix composites mounted on the leading and trailing edge was chosen for analysis of the temperature-time-thermal strain histories. Typical thermal expansion curves over the same range of temperature were selected at the beginning, mid, and end of the recording duration. The thermal expansion of selected post-flight LDEF samples were measured over the same range of temperature in the laboratory using a Michelson laser interferometer. The thermal strains were monitored concurrently with a laser interferometer and a mounted strain gage.

Le, T. D.↗

Efficiencies of Rotational Raman, and Rayleigh Techniques for Laser Remote Sensing of the Atmospheric Temperature

Various lidar methods have been developed for measuring the atmospheric temperature, making use of the temperature dependant characteristics of rotational Raman scattering (RRS) from nitrogen and oxygen, and Rayleigh or Rayleigh-Brillowin scattering (RS or RBS). These methods have various advantages and disadvantages as compared to each other but their potential accuracies are principal characteristics of their efficiency. No systematic attempt has been undertaken so far to compare the efficiences, in the above meaning, of different temperature lidar methods. Two RRS techniques have been compared. Here, we do such a comparison using two methods based on the detection and analysis of RS (RBS) spectra. Four methods are considered here for measuring the atmospheric temperature. One of them (Schwiesow and Lading, 1981) is based on an analysis of the RS linewidth with two Michelson interferometers (MI) in parallel. The second method (Shimisu et al., 1986) employs a high-resolution analysis of the RBS line shape. The third method (Cooney, 1972) employs the temperature dependance of the RRS spectrum envelope. The fourth method (Armstrong, 1974) makes use of a scanning Fabry-Perot interferometer (FPI) as a comb filter for processing the periodic RRS spectrum of the nitrogen. Let us denote the corresponding errors in measuring the temperature by sigma(sub MI), sigma(sub HR), sigma(sub ENV), and sigma(sub FPI). Let us also define the ratios chi(sub 1) = sigma(sub MI)/sigma(sub ENV), chi(sub 2) = sigma(sub HR)/sigma(sub ENV), and chi(sub 3) = sigma(sub FPI)/sigma(sub ENV) interpreted as relative errors with respect to sigma(sub ENV).

Ivanova, I. D.↗

Spatial heterodyne spectroscopy for the exploration of diffuse interstellar emission lines at far-ultraviolet wavelengths

Spatial heterodyne spectroscopy (SHS) is a new instrumental technique for interference spectroscopy which promises to extend into the FUV (1200-2000 A) spectral region the large throughput advantage at high spectral resolution usually associated with Fabry-Perot and Michelson interferometers. In addition, SHS systems are compact in size, can be field-widened to increase their throughput even further, have no moving parts, and can be built in all-reflection configurations. SHS appears to be well suited for high resolution, space-based spectroscopy of faint interstellar emission lines in the ultraviolet. This has significant implications for the study of the dynamics and distribution of hot gas within the Galactic disk and halo. For example, a field-widened SHS incorporating 5 x 5 cm gratings could obtain a radial velocity resolved (20 km/s), 3 deg angular resolution map of the high-latitude interstellar C IV 1550 emission in less than 1 year.

Harlander, J.↗

Report of the Science Working Group: Science with a lunar optical interferometer

Resolution is the greatest constraint in observational astronomy. The Earth's atmosphere causes on optical image to blur to about 1 arcsec or greater. Interferometric techniques have been developed to overcome atmospheric limitations for both filled aperture conventional telescopes and for partially filled aperture telescopes, such as the Michelson or the radio interferometer. The Hubble Space Telescope (HST) represents the first step toward space based optical astronomy. The HST represents an immediate short term evolution of observational optical astronomy. A longer time scale of evolution is focused on and the benefits are considered to astronomy of placing an array of telescopes on the Moon at a time when a permanent base may exist there.

Source record↗

Evaluation of integrated tuning elements with SIS devices

The resonance of integrated tuning stubs in combination with SIS detectors is measured and modeled. The predicted resonances are compared with measurements of stubs integrated with Nb/Al2O3/Nb junctions in a log-periodic antenna using a Michelson interferometer. Different stub lengths were made on different substrates (on 200 micron thick quartz and on a 7 micron thick silicon membrane) and the results show a fairly good agreement with the model calculations. Quartz substrates showed resonances up to 580 GHz, silicon membrane stub resonances reach as high as 480 GHz. An observed resonance at 560 GHz is probably a substrate effect from the membrane. The gap frequency for all the samples is 650 GHz and no resonances are detected above this frequency. Up to the maximum detected frequency dispersion is found to be negligible.

Dierichs, M. M. T. M.↗

Sapphire fiber interferometer for microdisplacement measurements at high temperature

Attention is given to the use of a short-length multimode sapphire rod as an extension to a conventional Michelson interferometric configuration, but with operation of Fabry-Perot cavity-based sensor element type. The performance of such a device as an interferometric sensor is demonstrated for a case where the interference between the reflections from the sapphire-air interface and an air-metallic surface is inspected for microdisplacements of the metallic surface. A detailed account is given of the sensor's fabrication procedure; results are presented for the detection of surface-acoustic waves.

Murphy, Kent A.↗

Sapphire fiber interferometer for microdisplacement measurements at high temperatures

We report the use of a short-length, multimode sapphire rod as an extension to a Michelson configuration, but operated as a low-finesse Fabry-Perot cavity. We demonstrate the performance of such a device as an interferometric sensor, where the interference between the reflections from the sapphire-air interface and an air-metallic surface is observed for microdisplacement of the metallic surface which is placed close to the sapphire endface. We describe in detail the fabrication procedure and present results obtained from the detection of temperature changes, applied strain, and surface acoustic waves.

Murphy, Kent A.↗

Long-baseline optical and infrared stellar interferometry

The history and the current status of optical and infrared long-baseline interferometry are reviewed. In particular, attention is given to Michelson interferometry; the Mark III stellar interferometer and its applications to astrometry, measurement of stellar diameters, and observations of binary stars; and advanced techniques. The discussion then focuses on astrometry and imaging with space interferometers. Finally, the future of long-baseline interferometry is briefly discussed with particular reference to the interferometry of the moon.

Shao, M.↗

Fourier Transform Fabry-Perot Interferometer

We are developing a compact, rugged, high-resolution remote sensing instrument with wide spectral scanning capabilities. This relatively new type of instrument, which we have chosen to call the Fourier-Transform Fabry-Perot Interferometer (FT-FPI), is accomplished by mechanically scanning the etalon plates of a Fabry-Perot interferometer (FPI) through a large optical distance while examining the concomitant signal with a Fourier-transform analysis technique similar to that employed by the Michelson interferometer. The FT-FPI will be used initially as a ground-based instrument to study near-infrared atmospheric absorption lines of trace gases using the techniques of solar absorption spectroscopy. Future plans include modifications to allow for measurements of trace gases in the stratosphere using spectral lines at terahertz frequencies.

Snell, Hilary E.↗

Cryogenic optical systems and instruments V; Proceedings of the Meeting, San Diego, CA, July 23, 24, 1992

Topics discussed in this volume include cryogenic system design and optical technology; cryogenic instruments; cryogenic/IR mechanisms, testing, and performance; and space cryogenic dewars and coolers. Papers included are on the SIRTF cryooptics technology plan, the development of the SPIRIT III sensor, the design of a rapidly cooled cryogenic mirror, the cryogenic Michelson interferometer on the Space Shuttle, a reflective optical system for a hemispherical field radiometer, and infrared filters for cryogenic radiometers. Attention is also given to the development of a variable-profile scan mirror mechanism, a direct-drive digitally commutated filter wheel positioning system for cryogenic optical applications, a high-performance chopping secondary mirror for infrared astronomy, recent developments in compressor-based Joule-Thomson cooling, a radiative cryogenic cooler for the pressure modulator IR radiometer, and SIRTF thermal design modifications to increase lifetime.

Melugin, Ramsey K.↗