Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

X-ray ablation of hyaluronan hydrogels: Fabrication of three-dimensional microchannel networks

We present a simple and highly versatile protocol for polymer ablation: hard x-ray irradiation makes it possible to rapidly depolymerize hyaluronan hydrogels and fabricate three-dimensional network of microchannels. Photodynamic and photochemical analyses show that x-ray irradiation directly cleaves the polymer backbone and the total dose controls the degradation kinetics. This nonthermal ablation protocol may offer opportunities for processing organic polymers and biological materials.

36 MATERIALS SCIENCE↗

Monte Carlo Simulations of Microchannel Plate Detectors II: Pulsed Voltage Results

This paper is part of a continuing study of straight-channel microchannel plate (MCP)–based x-ray detectors. Such detectors are a useful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy. To interpret the data from such detectors, it is critical to develop a better understanding of the behavior of MCPs biased with subnanosecond voltage pulses. The subject of this paper is a Monte Carlo computer code that simulates the electron cascade in a MCP channel under an arbitrary pulsed voltage, particularly those pulses with widths comparable to the transit time of the electron cascade in the MCP under DC voltage bias. We use this code to study the gain as a function of time (also called the gate profile or optical gate) for various voltage pulse shapes, including pulses measured along the MCP. In addition, experimental data of MCP behavior in pulsed mode are obtained with a short-pulse UV laser. Comparisons between the simulations and experimental data show excellent agreement for both the gate profile and the peak relative sensitivity along the MCP strips. We report that the dependence of relative gain on peak voltage increases in sensitivity in pulsed mode when the width of the high-voltage waveform is smaller than the transit time of cascading electrons in the MCP.

Kruschwitz, Craig A.↗

High precision particle mass sensing using microchannel resonators in the second vibration mode

An intrinsic uncertainty in particle mass sensing with the suspended microchannel resonator results from variation in a particle's position near the free end of the resonator. To circumvent this error we employ the second flexural bending mode. This mode exhibits additional frequency peaks while particles pass over the antinode, a point where the frequency shift is insensitive to the lateral position of the particle. We measure polystyrene beads with the first and second modes and confirm that the second mode sensing provides a narrower mass histogram. For 3 {mu}m diameter beads, second mode sensing at the antinode improves the coefficient of variation in buoyant mass from 1.76% to 1.05% for population measurements and from 1.40% to 0.53% for a single trapped particle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Precision viscosity measurement using suspended microchannel resonators

We report the characterization of a suspended microchannel resonator (SMR) for viscosity measurements in a low viscosity regime (<10 mPa s) using two measurement schemes. First, the quality factor (Q-factor) of the SMR was characterized with glycerol-water mixtures. The measured Q-factor at 20 Degree-Sign C exhibits a bilinear behavior with the sensitivity of 1281 (mPa s){sup -1} for a lower (1-4 mPa s) and 355 (mPa s){sup -1} for a higher viscosity range (4-8 mPa s), respectively. The second scheme is the vibration amplitude monitoring of the SMR running in a closed loop feedback. When compared in terms of the measurement time, the amplitude-based measurement takes only 0.1 {approx} 1 ms while the Q-factor-based measurement takes {approx}30 s. However, the viscosity resolution of the Q-factor-based measurement is at least three times better than the amplitude-based measurement. By comparing the Q-factors of heavy water and 9.65 wt.% glycerol-water mixture that have very similar viscosities but different densities, we confirmed that the SMR can measure the dynamic viscosity without the density correction. The obtained results demonstrate that the SMR can measure the fluid viscosity with high precision and even real-time monitoring of the viscosity change is possible with the amplitude-based measurement scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kelvin probe characterization of buried graphitic microchannels in single-crystal diamond

In this work, we present an investigation by Kelvin Probe Microscopy (KPM) of buried graphitic microchannels fabricated in single-crystal diamond by direct MeV ion microbeam writing. Metal deposition of variable-thickness masks was adopted to implant channels with emerging endpoints and high temperature annealing was performed in order to induce the graphitization of the highly-damaged buried region. When an electrical current was flowing through the biased buried channel, the structure was clearly evidenced by KPM maps of the electrical potential of the surface region overlying the channel at increasing distances from the grounded electrode. The KPM profiling shows regions of opposite contrast located at different distances from the endpoints of the channel. This effect is attributed to the different electrical conduction properties of the surface and of the buried graphitic layer. The model adopted to interpret these KPM maps and profiles proved to be suitable for the electronic characterization of buried conductive channels, providing a non-invasive method to measure the local resistivity with a micrometer resolution. The results demonstrate the potential of the technique as a powerful diagnostic tool to monitor the functionality of all-carbon graphite/diamond devices to be fabricated by MeV ion beam lithography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Macroscopic strain controlled ion current in an elastomeric microchannel

We report on the fabrication of an ultra-high aspect ratio ionically conductive single microchannel with tunable diameter from ≈ 20 μm to fully closed. The 4 mm-long channel is fabricated in a Polydimethylsiloxane (PDMS) mold and its cross-sectional area is controlled by applying macroscopic compressive strain to the mold in a direction perpendicular to the channel length. We investigated the ionic conduction properties of the channel. For a wide range of compressive strain up to ≈ 0.27, the strain dependence of the resistance is monotonic and fully reversible. For strain > 0.27, ionic conduction suddenly shuts off and the system becomes hysteretic (whereby a finite strain reduction is required to reopen the channel). Upon unloading, the original behavior is retrieved. This reversible behavior is observed over 200 compression cycles. The cross-sectional area of the channel can be inferred from the ion current measurement, as confirmed by a Nano-Computed Tomography investigation. We show that the cross-sectional area decreases monotonically with the applied compressive strain in the reversible range, in qualitative agreement with linear elasticity theory. We find that the shut-off strain is affected by the spatial extent of the applied strain, which provides additional tunability. Our tunable channel is well-suited for multiple applications in micro/nano-fluidic devices.

36 MATERIALS SCIENCE↗

Heat capacity measurements of sub-nanoliter volumes of liquids using bimaterial microchannel cantilevers

Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which is dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ∼10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g{sup −1 }K{sup −1}) and a resolution of 23 mJ/(g K) for ∼150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of X-ray radiation from a plasma in a microchannel of a copper target located in the air under the action of soft-focused femtosecond laser pulses with an intensity of 100 TW cm{sup −2}

We have studied the dependence of X-ray radiation yield in the range of more than 3 keV from a microchannel in a copper target on the laser pulse number at a (0.7 – 4.0) × 10{sup 14} W cm{sup −2} intensities of femtosecond laser radiation. A technique for estimating the intensity of laser radiation acting on the target using the slope of the X-ray bremsstrahlung spectrum is proposed. A possibility of using this technique for estimating the intensity in a femtosecond laser filament is considered. (interaction of laser radiation with matter. laser plasma)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Anode Square Microchannel Plate Photomultiplier Tube

Photek has developed a high performance 4096-anode photomultiplier tube using microchannel plates as the gain medium. Additionally, the detector has been designed in a square format to maximise the active area and allow for easy tiling to cover large areas using multiple units. This paper analyses the detector performance in terms of gain and photocathode uniformity, single photon timing accuracy, count rate capability, cross talk and magnetic field susceptibility.

47 OTHER INSTRUMENTATION↗

Imaging of large-area microchannel plates using phosphor screens

A testing system was built, using UV illumination at 254 nm and a cathodoluminescent phosphor screen, to measure the gain uniformity of large area (20 x 20 cm(2)) microchannel plates. The phosphor screen image is captured with a wide-angle CMOS digital camera (4032 x 3024 pixels) and analyzed. First a reference MCP is illuminated and the generated phosphor screen image is captured with a CCD camera. In a second step, another image is captured with the MCP under test inserted between the reference MCP and the phosphor screen. The ratio of the two images is analyzed and provides a quantitative measure of the relative gain uniformity of the MCP under test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Response of Microchannel Plate and Channel Electron Multiplier Detectors to Penetrating Radiation in Space

Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Here, our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area of multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency ε γ for 662 keVγ -rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Lastly, background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.

79 ASTRONOMY AND ASTROPHYSICS↗

A Microchannel Heat Exchanger Produced From a Metal Matrix Composite by Hybrid Laser Powder Bed Fusion and Inkjet Printing

Abstract This paper explores the production of an oxide dispersion strengthened (ODS) 304L stainless steel microchannel heat exchanger (HX) using a hybrid additive manufacturing process of laser powder bed fusion and inkjet printing. The study investigates the capabilities and economics of the hybrid inkjet-laser powder bed fusion (LPBF) process and evaluates the dimensional accuracy, functionality, and mechanical properties of the resulting ODS alloy. The effectiveness and pressure drop of the ODS heat exchangers produced by the hybrid LPBF tool are also determined. Results show that the inkjet-doped samples have a lower mean channel height with higher standard deviation than samples produced by LPBF alone. This is attributed to greater absorption of laser energy for the powder coated with the oxide precursor. The economic analysis shows that the hybrid process has a potential for reducing the unit cost of the heat exchanger based on cost modeling assumptions.

Engineering↗

Structural characteristics of a gas–liquid flow in a microchannel with a T-shaped mixer

The results of experimental studies of the structural characteristics of a nitrogen–water mixture flow in a horizontal microchannel provided with a T-shaped mixer are presented. The experiments are performed in a channel with a rectangular cross section of 250 × 315 μm under the conditions of a dominating influence of capillary forces. Structural characteristics of the flow are determined using the two-beam laser scanning and high-speed video capture at a distance of 500 calibers from the inlet in a wide range of reduced gas- and liquid-flow rates. A new method for the identification of flow regimes is proposed based on the statistical treatment of the laser-scanning data, and a map of flow patterns is constructed.

42 ENGINEERING↗

Progress Report on Model Development for the Transport of Aerosol through Microchannels

This report summarizes the current progress in the development of a phenomenological model of aerosol transport, deposition, and plugging through microchannels. The purpose is to introduce a generic, reliable numerical model for the prediction of aerosol transport, deposition, and plugging in leak paths while accounting for potential plugging formation, to a user community involving researchers, regulators, and industry. In that regard, a Graphical User Interface (GUI) was generated by integrating the individual MATLAB scripts that make up the model and adding additional features to aid the general understanding of the problem to a user. This report focuses on the model development and features included. Further, predictions from the GUI are compared with experimental data for validation. The strength of the GUI is the ability of a user to plug in basic parameters such as the initial pressure conditions and canister model specifications in order to obtain a first principal approximation of vital information such as the blowdown pressure differential, aerosol penetration, and deposition as a function of time. The user can obtain this without the know-how of the underlying MATLAB scripts and thus enables the model to be readily applied by regulators, industry, and shareholders to reduce the uncertainty in the off-site radiological consequences. The report also lists future tasks under this work scope. This includes ongoing efforts to include additional crack geometries (divergent and divergent-convergent slots) to the model; GUI development and improvement based on feedback from users, and integration of aerosol source term data from Sibling Pin tests into the model as we approach realistic canister stress corrosion cracking–induced aerosol release scenarios.

54 ENVIRONMENTAL SCIENCES↗

A Study of the Gain of Microchannel Plates in the Ionization Profile Monitors at Fermilab

One of the on-going issues with the use of microchannel plates (MCP) in the ionization profile monitors (IPM) at Fermilab is the significant decrease in gain over time. There are several possible issues that can cause this. Historically, the assumption has been that this is aging, where the secondary emission yield (SEY) of the pore surface changes after some amount of extracted charge. Recent literature searches have brought to light the possibility that this is an initial ‘scrubbing’ effect whereby adsorbed gasses are removed from the MCP pores by the removal of charge from the MCP. This paper discusses the results of studies conducted on the IPMs in the Main Injector at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electrocatalytically Upgrading Methane to Benzene in a Highly Compacted Microchannel Protonic Ceramic Membrane Reactor

This project aims to develop highly compacted microchannel protonic ceramic membrane reactors (HCM-PCMRs) for efficient and cost-effective methane dehydrogenation to aromatics (MDA, e.g., benzene). The integration of single-atom catalysis, electrocatalysis, membrane catalysis, membrane separation, and advanced manufacturing is designed to fulfill this goal. This project's success will ultimately develop a new cost-effective, efficient, and highly compacted infrastructure technology to address the flare and venting issue during oil and gas operations and other gas-to-liquid technologies. The key objectives for the three budget periods (BPs) are as follows.

02 PETROLEUM↗