Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Monte Carlo simulation of the classical two-dimensional one component plasma

Monte Carlo simulation, lattice dynamics in the harmonic approximation, and solution of the hypernetted chain equation were used to study the classical two-dimensional one component plasma. The system consists of a single species of charged particles immersed in a uniform neutralizing background. The particles interact via a l/r potential, where r is the two dimensional separation. Equations of state were calculated for both the liquid and solid phases. Results of calculation of the thermodynamic functions and one and two particle correlation functions are presented.

Gann, R. C.↗

Kinetic Monte Carlo Simulations of Chemical Reactions on Surfaces

Lattice based kinetic Monte Carlo (kMC) simulations are a powerful tool for micro-kinetic modeling. The kinetic Monte Carlo technique stochastically simulates chemical reaction processes (e.g. adsorption, desorption, diffusion), where the probability of a given reaction process being selected is weighted by its rate constant. The open source software package, KMOS1, allows fast construction of kMC simulations by automatically implementing a computationally efficient kMC framework, thus allowing the researcher to focus on accurate parameterization and formulation of the kinetic model. From this, the spatiotemporal evolution (e.g. concentration, surface configuration, turnover frequencies) of crystal surfaces or bulk crystalline structures is obtained. KMOS uses the variable step-size method implementation of kMC. At each step, the VSSM updates available events, calculates the corresponding transition rates and simulation time, and selects one of the available events. The lattice based kMC technique has many potential applications within SRNL where chemical kinetics are of interest. By transitioning through time along a trajectory of configuration space, fundamental insights to a system's dominant reactions and parameters can be gained, leading to improved materials and process design. In this work, we have established capabilities for fast implementation of kMC simulations through the installation and testing of the KMOS software on SRNL high performance computing resources. The parameterization of kMC simulations is often performed from first-principles energetic calculations. For the purposes of this work, the test cases use arbitrary species and thus, have arbitrary parameterization. In order to demonstrate the use of KMOS, two primary test cases are shown. Case 1 involves simple adsorption and desorption. Case 2 involves a slightly more complex mechanism. The evolution of the surface concentration and the final surface configuration for simulation Case 2 is shown. Rate-limiting processes and rate-limiting configurations are not always known or understood, but kMC provides information pertaining to both. The capability to implement efficient micro-kinetic models using the kinetic Monte Carlo technique has been established through the testing and installation of KMOS on SRNL HPC resources.

97 MATHEMATICS AND COMPUTING↗

IB: a Monte Carlo Simulation Tool for Neutron Scattering Instrument Design under Parallel Virtual Machine

IB is a Monte Carlo simulation tool for aiding neutron scattering instrument designs. It is written in C++ and implemented under Parallel Virtual Machine. The program has a few basic components, or modules, that can be used to build a virtual neutron scattering instrument. More complex components, such as neutron guides and multichannel beam benders, can be constructed using the grouping technique unique to IB. Users can specify a collection of modules as a group. For example, a neutron guide can be constructed by grouping four neutron mirrors together that make up the four sides of the guide. IB s simulation engine ensures that neutrons entering a group will be properly operated upon by all members of the group. For simulations that require higher computer speed, the program can be run in parallel mode under the PVM architecture. Initially, the program was written for designing instruments on pulsed neutron sources, it has since been used to simulate reactor based instruments as well.

Monte Carlo Simulations↗

Catastrophic rupture of lunar rocks - A Monte Carlo simulation

A computer model based on Monte Carlo techniques was developed to simulate the destruction of lunar rocks by 'catastrophic rupture' due to meteoroid impact. Energies necessary to accomplish catastrophic rupture were derived from laboratory experiments. A crater-production rate derived from lunar rocks was utilized to calculate absolute time scales. Calculated median survival times for crystalline lunar rocks are 1.9, 4.6, 10.3, and 22 m.y. for rock masses of 10, 100, 1000, and 10,000 g, respectively. Corresponding times of 6, 14.5, 32, and 68 million years are required before the probability of destruction reaches 0.99. These results are consistent with absolute exposure ages measured on returned rocks. Some results also substantiate previous conclusions that the catastrophic-rupture process is significantly more effective in obliterating lunar rocks than mass wasting by single-particle abrasion. The view is also corroborated that most rocks presently on the lunar surface either are exhumed from the regolith or are fragments of much larger boulders rather than primary ejecta excavated from pristine bedrock.

Hoerz, F.↗

Monte Carlo simulation of charged particles upstream of the earth's bow shock

A simple model of the earth's bow shock is presented and compared with ISEE-1 observations of diffuse ions upstream of the shock. Ion behavior is modeled in a test particle simulation using Monte Carlo techniques for a plane parallel shock at which cold solar wind ions are heated sufficiently to allow diffusion back upstream. Fitting of the model to the observations indicates that the diffusion coefficient must increase faster than linearly with velocity, and provides an upper limit to the acceleration efficiency defined as the proportion of incoming solar wind ions accelerated and observed upstream. Results suggest that astrophysical shocks are capable of accelerating ions directly from the thermal plasma without the need for a distinct preenergizing injection stage.

Ellison, D. C.↗

Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation

Purpose: To establish an organ dose database for pediatric and adolescent reference individuals undergoing computed tomography (CT) examinations by using Monte Carlo simulation. The data will permit rapid estimates of organ and effective doses for patients of different age, gender, examination type, and CT scanner model. Methods: The Monte Carlo simulation model of a Siemens Sensation 16 CT scanner previously published was employed as a base CT scanner model. A set of absorbed doses for 33 organs/tissues normalized to the product of 100 mAs and CTDI{sub vol} (mGy/100 mAs mGy) was established by coupling the CT scanner model with age-dependent reference pediatric hybrid phantoms. A series of single axial scans from the top of head to the feet of the phantoms was performed at a slice thickness of 10 mm, and at tube potentials of 80, 100, and 120 kVp. Using the established CTDI{sub vol}- and 100 mAs-normalized dose matrix, organ doses for different pediatric phantoms undergoing head, chest, abdomen-pelvis, and chest-abdomen-pelvis (CAP) scans with the Siemens Sensation 16 scanner were estimated and analyzed. The results were then compared with the values obtained from three independent published methods: CT-Expo software, organ dose for abdominal CT scan derived empirically from patient abdominal circumference, and effective dose per dose-length product (DLP). Results: Organ and effective doses were calculated and normalized to 100 mAs and CTDI{sub vol} for different CT examinations. At the same technical setting, dose to the organs, which were entirely included in the CT beam coverage, were higher by from 40 to 80% for newborn phantoms compared to those of 15-year phantoms. An increase of tube potential from 80 to 120 kVp resulted in 2.5-2.9-fold greater brain dose for head scans. The results from this study were compared with three different published studies and/or techniques. First, organ doses were compared to those given by CT-Expo which revealed dose differences up to several-fold when organs were partially included in the scan coverage. Second, selected organ doses from our calculations agreed to within 20% of values derived from empirical formulae based upon measured patient abdominal circumference. Third, the existing DLP-to-effective dose conversion coefficients tended to be smaller than values given in the present study for all examinations except head scans. Conclusions: A comprehensive organ/effective dose database was established to readily calculate doses for given patients undergoing different CT examinations. The comparisons of our results with the existing studies highlight that use of hybrid phantoms with realistic anatomy is important to improve the accuracy of CT organ dosimetry. The comprehensive pediatric dose data developed here are the first organ-specific pediatric CT scan database based on the realistic pediatric hybrid phantoms which are compliant with the reference data from the International Commission on Radiological Protection (ICRP). The organ dose database is being coupled with an adult organ dose database recently published as part of the development of a user-friendly computer program enabling rapid estimates of organ and effective dose doses for patients of any age, gender, examination types, and CT scanner model.

61 RADIATION PROTECTION AND DOSIMETRY↗

Direct simulation Monte Carlo on petaflop supercomputers and beyond

The gold-standard definition of the Direct Simulation Monte Carlo (DSMC) method is given in the 1994 book by Bird [Molecular Gas Dynamics and the Direct Simulation of Gas Flows (Clarendon Press, Oxford, UK, 1994)], which refined his pioneering earlier papers in which he first formulated the method. In the intervening 25 years, DSMC has become the method of choice for modeling rarefied gas dynamics in a variety of scenarios. The chief concern to applying DSMC to more dense or even continuum flows is its computational expense compared to continuum computational fluid dynamics methods. The dramatic (nearly billion-fold) increase in speed of the largest supercomputers over the last 30 years has thus been a key enabling factor in using DSMC to model a richer variety of flows, due to the method’s inherent parallelism. We have developed the open-source SPARTA DSMC code with the goal of running DSMC efficiently on the largest machines, both current and future. It is largely an implementation of Bird’s 1994 formulation. In this work, we describe algorithms used in SPARTA to enable DSMC to operate in parallel at the scale of many billions of particles or grid cells, or with billions of surface elements. We highlight a few examples of the kinds of fundamental physics questions and engineering applications that DSMC can address at these scales.

97 MATHEMATICS AND COMPUTING↗

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

SU-F-T-159: Monte Carlo Simulation Studies of Three-Dimensional Dose Distribution for Polymer Gel Dosimeter and Radiochromic Gel Dosimeter in a Proton Beam

Purpose: The purpose of this simulation study is to evaluate the proton detectability of gel dosimeters, and estimate the three-dimensional dose distribution of protons in the radiochromic gel and polymer gel dosimeter compared with the dose distribution in water. Methods: The commercial composition ratios of normoxic polymer gel and LCV micelle radiochromic gel were included in this simulation study. The densities of polymer and radiochromic gel were 1.024 and 1.005 g/cm3, respectively. The 50, 80 and 140 MeV proton beam energies were selected. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX 2.7.0, Los Alamos Laboratory). The water equivalent depth profiles and the dose distributions of two gel dosimeters were compared for the water. Results: In case of irradiating 50, 80 and 140 MeV proton beam to water phantom, the reference Bragg-peak depths are represented at 2.22, 5.18 and 13.98 cm, respectively. The difference in the water equivalent depth is represented to about 0.17 and 0.37 cm in the radiochromic gel and polymer gel dosimeter, respectively. The proton absorbed doses in the radiochromic gel dosimeter are calculated to 2.41, 3.92 and 6.90 Gy with increment of incident proton energies. In the polymer gel dosimeter, the absorbed doses are calculated to 2.37, 3.85 and 6.78 Gy with increment of incident proton energies. The relative absorbed dose in radiochromic gel (about 0.47 %) is similar to that of water than the relative absorbed dose of polymer gel (about 2.26 %). In evaluating the proton dose distribution, we found that the dose distribution of both gel dosimeters matched that of water in most cases. Conclusion: As the dosimetry device, the radiochromic gel dosimeter has the potential particle detectability and is feasible to use for quality assurance of proton beam therapy beam.

07 ISOTOPE AND RADIATION SOURCES↗

Monte Carlo simulation of a cesium atom beam in a magnetic field

We present Monte Carlo simulations of the deflection of a beam of {sup 133}Cs atoms in a two wire magnetic field. Our results reveal the relationship between transmission rate of the atoms and incident parameters. Incident angle and position of the beam with maximum transmission are obtained from the simulations. The effect of the deflection field on the spatial distribution (beam profile) of {sup 133}Cs is derived. The method will help with the design of magnetic deflection experiments and to extract the magnetic properties from such experiments.

43 PARTICLE ACCELERATORS↗

Fast and scalable quantum Monte Carlo simulations of electron-phonon models

We introduce methodologies for highly scalable quantum Monte Carlo simulations of electron-phonon models, and report benchmark results for the Holstein model on the square lattice. The determinant quantum Monte Carlo (DQMC) method is a widely used tool for simulating simple electron-phonon models at finite temperatures, but incurs a computational cost that scales cubically with system size. Alternatively, near-linear scaling with system size can be achieved with the hybrid Monte Carlo (HMC) method and an integral representation of the Fermion determinant. Here, we introduce a collection of methodologies that make such simulations even faster. To combat "stiffness" arising from the bosonic action, we review how Fourier acceleration can be combined with time-step splitting. To overcome phonon sampling barriers associated with strongly-bound bipolaron formation, we design global Monte Carlo updates that approximately respect particle-hole symmetry. To accelerate the iterative linear solver, we introduce a preconditioner that becomes exact in the adiabatic limit of infinite atomic mass. Finally, we demonstrate how stochastic measurements can be accelerated using fast Fourier transforms. Here, these methods are all complementary and, combined, may produce multiple orders of magnitude speedup, depending on model details.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying the Effect of Undersampling in Monte Carlo Simulations Using SCALE

This study explores the effect of undersampling in Monte Carlo calculations on tally estimates and tally variance estimates for burnup credit applications. Steady-state Monte Carlo simulations were performed for models of several critical systems with varying degrees of spatial and isotopic complexity and the impact of undersampling on eigenvalue and flux estimates was examined. Using an inadequate number of particle histories in each generation was found to produce an approximately 100 pcm bias in the eigenvalue estimates, and biases that exceeded 10% in fuel pin flux estimates.

bias↗

Path Integral Monte Carlo Simulations of Iron Plasmas (Final Technical Report)

This documents is the final technical report for our grant entitled "Path Integral Monte Carlo Simulations of Iron Plasmas" that focused on developing path integral Monte Carlo (PIMC) computer simulations. This techniques will be developed to study plasmas composed of heavier elements including iron and other third row elements. Equations of state (EOS) and transport properties will be derived in the regime of warm dense matter (WDM) and dense plasmas where existing first-principles methods cannot be applied. While standard density functional theory (DFT) has been used to accurately predict the structure of many solids and liquids up to temperatures on the order of 100,000 K, this method is not applicable at much higher temperature because the number of partially occupied electronic orbitals reaches intractably large numbers or the use of finite-temperature free energy functionals in orbital-free DFT introduces an uncontrolled approximation. Here we focus on PIMC methods that become more and more efficient with increasing temperatures and still include all electronic correlation effects. In this approach, electronic excitations increase the efficiency rather than reduce it. While it had commonly been assumed this method could only be applied to elements without core electrons, we showed that PIMC with free-particle nodes works well for first-row elements (PRL 108 (2012) 115502). Most recently, we extended the applicability range of all-electron PIMC to second-row elements by adopting localized nodal surfaces (PRL 115 (2015) 176403). To simulate third-row elements efficiently under WDM conditions, we propose a new method to remove core electrons by introducing pseudo-nodes. We explain our approach step by step and present preliminary results. We focus our method development on getting PIMC simulations of iron to work because of its fundamental importance for WDM and astrophysics. Then we move on to krypton and copper-doped beryllium, a ICF ablator material. We plan to continue working on key second-row material such as Na, Mg, MgO, Al, silica, and silicon-doped plastic ablators. Our collaborators at LLNL, will use our PIMC EOS data both as comparisons to existing semi-empirical, EOS-generating schemes, and as input for continuum radiation hydrodynamics simulations. We will establish an efficient pipeline from PIMC to macroscopic continuum studies of materials response. An emphasis will be placed on benchmarking such methods for plasmas of heavy elements at the very high temperatures (~100 eV) and low densities that are generated when Hohlraum radiation heats the ablator material in indirect drive laser experiments. Results from changes to the EOS will be of immeasurable importance to the designers at the National Ignition Facility (NIF) and at other facilities. Starting with our EOS of Cu-doped Be, our second collaborator at LLE, will perform real-time simulations of laser fusion experiments at the Omega laser and at the NIF to determine how sensitive the compression path depends on the ablator EOS. Since our collaborator also has experience in performing orbital-free DFT calculations, we propose to compare predictions from this method with PIMC results. In joint publications, we plan to analyze the accuracy of different free-energy functionals in order to understand why existing orbital-free DFT calculations do not predict compression peaks along the shock Hugoniot curve that we see with PIMC. The peaks are caused by the ionization of various electron shells. Their accurate characterization is important to compare with experimental results. We will break new ground by developing PIMC techniques that can simulate iron and all other third row elements in the plasma and WDM regimes. We introduce the concept of pseudo-nodes for the efficient treatment of the core-electrons. The EOS and transport properties will be derived and published online in the form of a new WDM database. Our PIMC EOS calculations will benchmark and possibly replace semi-analytical EOS tables like QEOS or SESAME, which will impact the hydrocode simulation community and will affect the design of NIF targets. Our PIMC results will help to improve the accuracy of orbital-free DFT simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applying Monte Carlo Simulation to Launch Vehicle Design and Requirements Analysis

This Technical Publication (TP) is meant to address a number of topics related to the application of Monte Carlo simulation to launch vehicle design and requirements analysis. Although the focus is on a launch vehicle application, the methods may be applied to other complex systems as well. The TP is organized so that all the important topics are covered in the main text, and detailed derivations are in the appendices. The TP first introduces Monte Carlo simulation and the major topics to be discussed, including discussion of the input distributions for Monte Carlo runs, testing the simulation, how many runs are necessary for verification of requirements, what to do if results are desired for events that happen only rarely, and postprocessing, including analyzing any failed runs, examples of useful output products, and statistical information for generating desired results from the output data. Topics in the appendices include some tables for requirements verification, derivation of the number of runs required and generation of output probabilistic data with consumer risk included, derivation of launch vehicle models to include possible variations of assembled vehicles, minimization of a consumable to achieve a two-dimensional statistical result, recontact probability during staging, ensuring duplicated Monte Carlo random variations, and importance sampling.

Hanson, J. M.↗

Monte Carlo simulation of astronaut light flash observations on Apollo and Skylab missions

Monte Carlo calculations are performed to study the relation between cosmic ray nuclei and visual flashes observed by astronauts, in space. A satisfactory overall fit to all available data excluding the Skylab observations in the South Atlantic Anomaly (SAA) has been achieved by varying three visual system parameters: effective retinal thickness, minimum projected track length inside retina and minimum energy loss rate. All light flash data from space excluding the SAA observations can be understood fully upon the basis of the primary cosmic ray charge and energy spectra together with the fitted values of the three visual system parameters. Monte Carlo simulations of the SAA observations suggest the existence of a previously unobserved multiply-charged component of the inner radiation belt.

Osborne, W. Z.↗

Monte Carlo Simulation of THz Multipliers

Schottky Barrier diode frequency multipliers are critical components in submillimeter and Thz space based earth observation systems. As the operating frequency of these multipliers has increased, the agreement between design predictions and experimental results has become poorer. The multiplier design is usually based on a nonlinear model using a form of harmonic balance and a model for the Schottky barrier diode. Conventional voltage dependent lumped element models do a poor job of predicting THz frequency performance. This paper will describe a large signal Monte Carlo simulation of Schottky barrier multipliers. The simulation is a time dependent particle field Monte Carlo simulation with ohmic and Schottky barrier boundary conditions included that has been combined with a fixed point solution for the nonlinear circuit interaction. The results in the paper will point out some important time constants in varactor operation and will describe the effects of current saturation and nonlinear resistances on multiplier operation.

East, J.↗

Development of Monte Carlo Simulation Code to Model Behavior of Hydrogen Isotopes Loaded into Tungsten Containing Vacancies

The behavior of hydrogen isotopes implanted into tungsten containing vacancies was simulated using a Monte Carlo technique. The correlations between the distribution of implanted deuterium and fluence, trap density and trap distribution were evaluated. Throughout the present study, qualitatively understandable results were obtained. In order to improve the precision of the model and obtain quantitatively reliable results, it is necessary to deal with the following subjects: (1) how to balance long-time irradiation processes with a rapid diffusion process, (2) how to prevent unrealistic accumulation of hydrogen, and (3) how to model the release of hydrogen forcibly loaded into a region where hydrogen densely exist already.

08 HYDROGEN↗

Evaluation of the interindividual human variation in bioactivation of methyleugenol using physiologically based kinetic modeling and Monte Carlo simulations

The present study aims at predicting the level of formation of the ultimate carcinogenic metabolite of methyleugenol, 1′-sulfooxymethyleugenol, in the human population by taking variability in key bioactivation and detoxification reactions into account using Monte Carlo simulations. Depending on the metabolic route, variation was simulated based on kinetic constants obtained from incubations with a range of individual human liver fractions or by combining kinetic constants obtained for specific isoenzymes with literature reported human variation in the activity of these enzymes. The results of the study indicate that formation of 1′-sulfooxymethyleugenol is predominantly affected by variation in i) P450 1A2-catalyzed bioactivation of methyleugenol to 1′-hydroxymethyleugenol, ii) P450 2B6-catalyzed epoxidation of methyleugenol, iii) the apparent kinetic constants for oxidation of 1′-hydroxymethyleugenol, and iv) the apparent kinetic constants for sulfation of 1′-hydroxymethyleugenol. Based on the Monte Carlo simulations a so-called chemical-specific adjustment factor (CSAF) for intraspecies variation could be derived by dividing different percentiles by the 50th percentile of the predicted population distribution for 1′-sulfooxymethyleugenol formation. The obtained CSAF value at the 90th percentile was 3.2, indicating that the default uncertainty factor of 3.16 for human variability in kinetics may adequately cover the variation within 90% of the population. Covering 99% of the population requires a larger uncertainty factor of 6.4. In conclusion, the results showed that adequate predictions on interindividual human variation can be made with Monte Carlo-based PBK modeling. For methyleugenol this variation was observed to be in line with the default variation generally assumed in risk assessment. - Highlights: • Interindividual human differences in methyleugenol bioactivation were simulated. • This was done using in vitro incubations, PBK modeling and Monte Carlo simulations. • Major enzymatic reactions causing interindividual differences were identified. • A chemical-specific adjustment factor (CASF) for intraspecies variation was derived. • The default uncertainty factor for kinetic human variability covers 90% of population.

60 APPLIED LIFE SCIENCES↗