At least 199 records · Page 11

Absorption of wireless radiation in the child versus adult brain and eye from cell phone conversation or virtual reality

Highlights: • More cell phone radiation is absorbed by children's inner brain tissues than adults’. • Children's radiofrequency radiation exposure should be reduced. • Further research to evaluate the risks to the eye from use of VR is urgently needed. • It is biologically relevant and feasible to reduce the standards’ averaging volume. • Current methods to determine wireless device compliance should be revised. Children's brains are more susceptible to hazardous exposures, and are thought to absorb higher doses of radiation from cell phones in some regions of the brain. Globally the numbers and applications of wireless devices are increasing rapidly, but since 1997 safety testing has relied on a large, homogenous, adult male head phantom to simulate exposures; the “Standard Anthropomorphic Mannequin” (SAM) is used to estimate only whether tissue temperature will be increased by more than 1 Celsius degree in the periphery. The present work employs anatomically based modeling currently used to set standards for surgical and medical devices, that incorporates heterogeneous characteristics of age and anatomy. Modeling of a cell phone held to the ear, or of virtual reality devices in front of the eyes, reveals that young eyes and brains absorb substantially higher local radiation doses than adults’. Age-specific simulations indicate the need to apply refined methods for regulatory compliance testing; and for public education regarding manufacturers' advice to keep phones off the body, and prudent use to limit exposures, particularly to protect the young.

54 ENVIRONMENTAL SCIENCES↗

Verification of Spent Nuclear Fuel in Sealed Dry Storage Casks via Measurements of Cosmic-Ray Muon Scattering

Most of the plutonium in the world resides inside spent nuclear reactor fuel rods. This high-level radioactive waste is commonly held in long-term storage within large, heavily shielded casks. Currently, international nuclear safeguards inspectors have no stand-alone method of verifying the amount of reactor fuel stored within a sealed cask. In this paper, we demonstrate experimentally that measurements of the scattering angles of cosmic-ray muons, which pass through a storage cask, can be used to determine if spent fuel assemblies are missing without opening the cask. Finally, this application of technology and methods commonly used in high-energy particle physics provides a potential solution to this long-standing problem in international nuclear safeguards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A comparison of numerical methods for the Rayleigh equation in unbounded domains

A second-order finite difference and two spectral methods, including a Chebyshev tau and a Chebyshev collocation method were implemented to determine the linear hydrodynamic stability of an unbounded shear flow. The velocity profile of the basic flow in the stability analysis mimicks that of a one-stream free mixing layer. Local and global eigenvalue solution methods are used to determine individual eigenvalues and the eigenvalue spectrum, respectively. The calculated eigenvalue spectrum includes a discrete mode, a continuous spectrum associated with the equation singularity and a continuous spectrum associated with the domain unboundedness. The efficiency and the accuracy of these discretization methods in the prediction of the eigensolutions of the discrete mode were evaluated by comparison with a conventional shooting procedure. Their capabilities in mapping out the continuous eigenvalue spectra are also discussed.

Liou, W. W.↗

Diffuse continuum gamma rays from the Galaxy observed by COMPTEL

The diffuse Galactic continuum gamma-ray emission has been studied using the full Sky Survey from COMPTEL on the Compton Observatory CGRO. The diffuse emission appears to be visible in the whole 0.75-30 MeV range covered by the instrument, although a considerable contribution from unresolved point sources cannot be excluded. A correlation analysis using HI and CO surveys of the Galaxy is used to derive the Galactic emissivity spectrum, and this is consistent with a smooth continuation to the spectrum at higher energies derived by a similar analysis of COS-B data. The apparent conversion factor from integrated CO temperature to molecular hydrogen column density can also be determined from the correlation analysis. The value obtained is consistent with results from COS-B and other non-gamma-ray methods. Calculations of the emissivity spectrum from bremsstrahlung from a cosmic-ray electron spectrum based on propagation models are compared with the observations.

Strong, A. W.↗

Cosmic Ray Muon Imaging of Spent Nuclear Fuel in Dry Storage Casks

In this paper, cosmic ray muon radiography has been used to identify the absence of spent nuclear fuel bundles inside a sealed dry storage cask. The large amounts of shielding that dry storage casks use to contain radiation from the highly radioactive contents impedes typical imaging methods, but the penetrating nature of cosmic ray muons allows them to be used as an effective radiographic probe. This technique was able to successfully identify missing fuel bundles inside a sealed Westinghouse MC-10 cask. This method of fuel cask verification may prove useful for international nuclear safeguards inspectors. Finally, muon radiography may find other safety and security or safeguards applications, such as arms control verification.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Opportunistic bone density screening for the abdominal radiologist using colored CT images: a pilot retrospective study

Purpose: The purpose of the study was to develop an accurate and reproducible method for detecting low spinal bone density on abdominal CT images. Methods: For this IRB-approved HIPAA-compliant single-center retrospective study, nonenhanced CT images of the lower abdomen were obtained in 631 African-American participants. Mean attenuation of L3/L4 was associated with quantitative CT bone density (QCT) in a randomly selected training cohort (N = 511), and receiver operating characteristics analysis was used to identify the optimal mean attenuation threshold for differentiating normal from low bone density. Custom image processing software was used to generate grayscale and colored CT images of the midline spine, with green for normal and red for low bone density. Five radiologists independently assessed bone density at L3/L4 in a validation cohort (N = 120) using various methods: QCT, visual assessment of sagittal grayscale images (Grayscale), quantitative measurement of mean attenuation on a midline sagittal image (Attenuation), and visual assessment of a midline sagittal colored image (Color). Accuracy was calculated using the average QCT bone density as a reference standard. Inter-observer agreement was assessed using intraclass correlation coefficient (ICC). Results: The optimal mean attenuation threshold for differentiating normal from low bone density at L3/L4 was 145 Hounsfield Units. The average accuracy of Grayscale, Attenuation, and Color methods was 58, 87, and 91% (p < 0.001), respectively. Inter-observer agreement was poor for Grayscale (ICC: 0.20; 95% CI 0.12, 0.28) and excellent for both Attenuation (ICC: 0.85; 95% CI 0.73, 0.91) and Color methods (ICC: 0.87; 95% CI 0.83, 0.90). Conclusion: Detection of low spinal bone density using colored abdominal CT images was highly accurate and reproducible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Continuum Model of Gas Uptake for Inhomogeneous Fluids

We describe a continuum model of gas uptake for inhomogeneous fluids (CMGIF) and use it to predict fluid adsorption in porous materials directly from gas-substrate interaction energies determined by first principles calculations or accurate effective force fields. The method uses a perturbation approach to correct bulk fluid interactions for local inhomogeneities caused by gas substrate interactions, and predicts local pressure and density of the adsorbed gas. The accuracy and limitations of the model are tested by comparison with the results of Grand Canonical Monte Carlo simulations of hydrogen uptake in metal-organic frameworks (MOFs). We show that the approach provides accurate predictions at room temperature and at low temperatures for less strongly interacting materials. As a result, the speed of the CMGIF method makes it a promising candidate for high-throughput materials discovery in connection with existing databases of nano-porous materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The eigenvalue spectrum of the Rayleigh equation for a plane shear layer

The eigenvalue spectrum of the Rayleigh equation is examined using three different solution techniques. In particular, a simple second-order finite difference scheme and two spectral methods, the Chebyshev tau and Chebyshev collocation methods, are used to discretize the equation. All of the approximation methods are shown to be capable of predicting the discrete spectrum as well as the continuous spectrum associated with the critical point singularity for the Rayleigh equation. The global eigenvalue methods considered here provide an efficient way of obtaining either an approximation to the complete eigenvalue spectrum or initial guesses for a local shooting procedure for the discrete part of the spectrum.

Liou, William W.-W.↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

Analog B ( M 1 ) strengths in the T z = ± 3 2 mirror nuclei Mn 47 and Ti 47

The lifetimes of the first excited 7 2 − states in the T z = ± 3 2 mirror nuclei Mn 47 and Ti 47 have been extracted utilizing the γ -ray line shape method, giving τ = 687 ( 36 ) ps and τ = 331 ( 15 ) ps respectively. Since these transitions are essentially pure M 1 transitions, these results allow for a high-precision comparison of analog M 1 strengths in mirror nuclei. The two analog B ( M 1 ) s are observed to be identical to a precision of about 10 % . The expected dependence of the transition matrix element with T z has been used to extract the separate isoscalar and isovector components of the transition strength, and the results are discussed in the context of predictions, based on the isospin formalism, regarding analog B ( M 1 ) strengths. Published by the American Physical Society 2024

39 ≤ A ≤ 58↗

Design and Analysis of the US ITER Central Solenoid Module Lifting Fixture

The central solenoid (CS) consists of six large high field superconducting magnets (also known as modules) approximately 4 m in diameter and 2 m tall that weigh approximately 120 tonnes each. These large and complex modules create challenges during assembly of the CS that require the development of custom assembly tooling such as the CS lifting fixture. The CS module lifting fixture is designed to lift and stack the six CS modules in the assembly building on the ITER site. Because of its unique design, fabrication, and assembly features, no lifting attachments could be incorporated within or under the CS modules. This limitation motivated the development of a friction-based lift fixture. The design and evaluation of the CS module lifting fixture considered both worker safety and investment protection, and the assessments were performed to international codes and standards. The CS module lifting fixture consists of two principal subassemblies: spider assembly and ring weldment. These subassemblies allow the frictional force to be augmented by the mechanical advantage of shallow-angle wedges. Large radial preloads created by both screw jack assemblies and the weight of a CS module develop frictional forces capable of performing a lift with a safety factor of at least 2. The design effort resulted in the use of low friction linear bearings on angle surfaces to ensure constant pressure, integrated jacks for pretensioning the fixture prior to lifting, and load pin strain gauges for monitoring the normal force. Testing of various materials and surface treatments led to the selection of laminated aluminum and rubber pads as the friction interface on the CS lifting fixture side and a grit-blasted Nitronic 50 stainless steel band on the CS module side. A redundant lifting method using the module slings between the spider and module is also utilized after the initial friction lift. The CS lifting fixture provides a safe and reliable solution for lifting and stacking the CS module during assembly.

Morris, Eric↗

Combining diagnostics, modeling, and control systems for automated alignment of the TES beamline

X-ray beamlines are essential components of all synchrotron light sources. Practical operations involve frequent variation in beamline component positions and orientation, particularly when photon beam parameters shift due to experimental needs, or due to variations in the incoming photon beam. The alignment process can be time consuming and takes away from valuable beam time for experimental data collection. We describe progress in the automation of certain alignment tasks on the tender-energy X-ray spectroscopy (TES) beamline at the National Synchrotron Light Source II (NSLS-II). The beamline is controlled using the BlueSky software in which high level experimental plans guide the beamline components during an experiment. Numerous software packages exist for beamline modeling, and they may be tied to the beamline control system using a package we are continuing to develop called Sirepo-Bluesky. The photon beam distribution may be measured with fluorescent screens, and a relation between beam and machine state can be found by varying the mirror and aperture settings over a multi-dimensional range. We describe the results of such parameter varying measurements and how we are combining Sirepo-Bluesky with machine learning methods and reduced models to automate mirror alignment on the TES beamline.

36 MATERIALS SCIENCE↗

Correlation Function Approach for Diffusion in Confined Geometries

This paper describes a formalism for extracting spatially varying transport coefficients from simulations of a molecular fluid in a nano channel. This approach is applied to self-diffusion of a Lennard-Jones fluid confined between two parallel surfaces. A numerical grid is laid over the domain confining the fluid, and fluid properties are projected onto the grid cells. The time correlation functions between properties in different grid cells are calculated and can be used as the basis for a fitting procedure for extracting spatially varying diffusion coefficients from the simulation. Results for the Lennard-Jones system show that transport behavior varies sharply near the liquid-solid boundary and that the changes depend on the details of the liquid-solid interaction. A quantitative difference between the reduced and detailed models is discussed. It is found that the difference could be associated with assumptions about the form of the transport equations at molecular scales in lieu of problems with the method itself. The study suggests that this approach to fitting molecular simulations to continuum equations may guide the development of appropriate coarse-grained equations to model transport phenomena at nanometer scales.

Nanoscale flow, Transport, molecular simulation↗

Effects of microscopic iron metal on the reflectance spectra of glass and minerals

Maturity, which is a measure of the time lunar soils have been in the upper approximately 1 mm of the surface, is correlated with changes in the soils' optical properties. Mature soil is darker and somewhat redder than immature soil of the same composition, and features in the reflectance spectrum become more subdued with increasing maturity. The maturation process also involves accumulation of agglutinitic glass and submicroscopic metallic iron particles. We have produced submicrometer iron metal blebs on the surface and within glass and mineral grains by the method of high-temperature reduction. This technique has permitted the determination of optical changes in samples much simpler than lunar soil, and offers a useful tool with which to investigate the maturation process.

Allen, C. C.↗

Percutaneous Vertebroplasty for Pain Management in Patients with Multiple Myeloma: Is Radiofrequency Ablation Necessary?

Purpose: This study was designed to investigate the added role of radiofrequency ablation (RFA) to vertebroplasty on the pain management of patients with multiple myeloma (MM). Methods: Thirty-six patients (51–82 years) with vertebral localization of MM were randomly divided into two groups: 18 patients (group A) who underwent RFA and then vertebroplasty, and 18 patients (group B) who underwent only vertebroplasty. Primary endpoints were technical success and pain relief score rate measured by the visual analogue pain scores (VAS) and Roland–Morris Questionnaire (RMQ); secondary endpoint was the amount of administered analgesia. Survival and complications were compared. Results: Technical success was 100 % in both groups. The VAS score (at 24 h and 6 weeks postprocedure) decreased in equal manner for both groups from a mean of 9.1–3.4 and 2.0 for group A and from a mean of 9.3–3.0 and 2.3 for group B; RMQ mean score was 19.8 for group A and 19.9 for group B and decreased to a mean of 9.6 and 8.2 for group A and 9.5 and 8.7 for group B. The amount of medication was equally decreased in the two groups. No statistically significant difference was noted. No major complication occurred and two patients died from other causes. Conclusions: The use of percutaneous vertebroplasty alone appears to be effective for the pain management of the patients with vertebral involvement of multiple myeloma. The use of RFA that includes cost and time does not offer any clear added benefit on the midterm pain management of such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parallel Radioisotope Collection and Analysis in Response to the Fukushima Release

Two independent air samplers were operated at Pacific Northwest National Laboratory in parallel during the collection of samples from the Fukushima reactor releases. One system is an automated aerosol collection and analysis unit, while the other was a manual sampler of higher daily air volume. The samples collected each day showed excellent correlation in radionuclide activity, although some variations were seen. These variations illustrate the reproducibility of the air sample radionuclide measurements made by the Comprehensive Nuclear-Test-Ban Treaty International Monitoring System (IMS) and show a simple way to acquire useful parallel samples for scientific purposes. In particular, a party wishing to have a “copy” of a sample acquired by the verification regime of the treaty could employ this method and have results similar to the IMS station at low cost and even higher sensitivity.

Atmospheric Aerosol Sampling↗

Prostate brachytherapy postimplant dosimetry: Seed orientation and the impact of dosimetric anisotropy in stranded implants

Purpose: In postimplant dosimetry for prostate brachytherapy, dose is commonly calculated using the TG-43 1D formalism, because seed orientations are difficult to determine from CT images, the current standard for the procedure. However, the orientation of stranded seeds soon after implantation is predictable, as these seeds tend to maintain their relative spacing, and orient themselves along the implant trajectory. The aim of this study was to develop a method for determining seed orientations from reconstructed strand trajectories, and to use this information to investigate the dosimetric impact of applying the TG-43 2D formalism to clinical postimplant analysis. Methods: Using in-house software, the preplan to postimplant seed correspondence was determined for a cohort of 30 patients during routine day-0 CT-based postimplant dosimetry. All patients were implanted with stranded-seed trains. Spline curves were fit to each set of seeds composing a strand, with the requirement that the distance along the spline between seeds be equal to the seed spacing within the strand. The orientations of the seeds were estimated by the tangents to the spline at each seed centroid. Dose distributions were then determined using the 1D and 2D TG-43 formalisms. These were compared using the TG-137 recommended dose metrics for the prostate, prostatic urethra, and rectum. Results: Seven hundred and sixty one strands were analyzed in total. Defining the z-axis to be cranial-positive and the x-axis to be left-lateral positive in the CT coordinate system, the average seed had an inclination of 21 deg. {+-} 10 deg. and an azimuth of -81 deg. {+-} 57 deg. These values correspond to the average strand rising anteriorly from apex to base, approximately parallel to the midsagittal plane. Clinically minor but statistically significant differences in dose metrics were noted. Compared to the 2D calculation, the 1D calculation underestimated prostate V100 by 1.1% and D90 by 2.3 Gy, while overestimating V150 and V200 by 1.6% and 1.3%, respectively. Urethral and rectal dose quantifiers tended to be underestimated by the 1D calculation. The most pronounced differences were in the urethral D30 and rectal D2cc, which rose by 3.8 and 1.9 Gy, respectively, using the 2D calculation. The total volume of the 100% isodose region as a percentage of the prostate volume was found to increase by 0.4%. Conclusions: Stranded seeds in the supine patient are not oriented in a uniformly random manner, nor are they aligned along the axis of the CT scanner. Instead, this study identified a consistent anterior pitch that is likely attributable to differences in patient pose between implant and CT imaging. The angle of the ultrasound probe with respect to the patient during implant may have also been a contributing factor. The dose metrics derived using the 1D formalism were found to be within 2%, on average, of those derived using the 2D formalism. For greater accuracy, 2D dosimetry can be pursued using the strand-fitting method described in this work. If a 1D representation is used, integrating over the empirically determined seed orientation density reported here may be more appropriate than assuming that seed inclinations are distributed uniformly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uniform Silicon Isotope Ratios Across the Milky Way Galaxy

We report the relative abundances of the three stable isotopes of silicon, {sup 28}Si, {sup 29}Si, and {sup 30}Si, across the Galaxy using the v=0,J=1→0 transition of silicon monoxide. The chosen sources represent a range in Galactocentric radii (R{sub GC}) from 0 to 9.8 kpc. The high spectral resolution and sensitivity afforded by the Green Bank Telescope permit isotope ratios to be corrected for optical depths. The optical-depth-corrected data indicate that the secondary-to-primary silicon isotope ratios {sup 29}Si/{sup 28}Si and {sup 30}Si/{sup 28}Si vary much less than predicted on the basis of other stable isotope ratio gradients across the Galaxy. Indeed, there is no detectable variation in Si isotope ratios with R{sub GC}. This lack of an isotope ratio gradient stands in stark contrast to the monotonically decreasing trend with R{sub GC} exhibited by published secondary-to-primary oxygen isotope ratios. These results, when considered in the context of the expectations for chemical evolution, suggest that the reported oxygen isotope ratio trends, and perhaps those for carbon as well, require further investigation. The methods developed in this study for SiO isotopologue ratio measurements are equally applicable to Galactic oxygen, carbon, and nitrogen isotope ratio measurements, and should prove useful for future observations of these isotope systems.

79 ASTRONOMY AND ASTROPHYSICS↗