Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mu2e”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Design and status of the Mu2e electromagnetic calorimeter

Here, the Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5×10 –17 after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF 2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D; studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e Calorimeter Readout System

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: (1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; (2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of 200MHz with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of 20krads , neutron flux of 10 12 n(1MeVeq)/cm 2 , magnetic field of 1T and in vacuum level of 10 -4 Torr . A description of the readout system and qualification tests is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-track reconstruction algorithms in the Mu2e experiment

The Mu2e experiment, under construction at Fermilab, will search for the neutrino-less coherent µ−N → e−N conversion in the field of a 27 Al nucleus, a CLFV process. While the main goal of the experiment is to reconstruct the conversion electron, i.e., an event with a single track, there are motivations to develop an efficient tracking algorithm for reconstructing more simultaneous tracks. This could better constrain the background generated by p¯-annihilation in the Al target and search for Beyond the Standard Model processes. In this paper, we present the algorithms designed to reconstruct multi-particle events.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

The Mu2e Muon Beamline

The muon source for the Mu2e experiment at Fermilab is described in detail. Requirements, design and simulations are described and some possible modifications are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extinction in the Mu2e Beam Line

The proposed Mu2e experiment at Fermilab has very specific requirements for the proton beam which is used to produce muons. It requires short proton bunches (<100 ns FW), separated by 1-2 musec. It is vital that the beam outside of the bunches be suppressed at a level of at least 10{sup 9} relative to the beam in the bunches. This note briefly presents the motivation for this 'extinction' requirement, and then describes how the experiment hopes to achieve it. Finally, possible techniques for measuring the extinction will be discussed.

43 PARTICLE ACCELERATORS↗

Study of thermosiphon cooling scheme for the production solenoid of the Mu2e experiment at Fermilab

A thermosiphon cooling scheme is envisioned for the Production Solenoid of the Mu2e experiment at Fermi National Accelerator Laboratory. The thermosiphon cooling is achieved by indirect cooling with helium at 4.7 K. The siphon tubes are welded to the solenoid outer structure. The anticipated heat loads in the solenoid is presented as well as the cooling scheme design. A thermal model using ANSYS to simulate the temperature gradient is presented. The thermal analysis also makes provisions for including the heat load generated in the coils and structures by the secondary radiation simulated using the MARS 15 code. The impact of the heat loads from supports on the solenoid cooling is studied. The thermosiphon cooling scheme is also validated using pertinent correlations to study flow reversals and the cooling regime.

43 PARTICLE ACCELERATORS↗

Offline Software for the Mu2e Experiment

The Mu2e experiment at Fermilab is in the midst of its R&D and approval processes. To aid and inform this process, a small team has developed an end-to-end Geant4-based simulation package and has developed reconstruction code that is already at the stage of an advanced prototype. Having these tools available at an early stage allows design options and tradeoffs to be studied using high level physics quantities. A key to the success of this effort has been, as much as possible, to acquire software and customize it, rather than to build it in-house.

Kutschke, Robert K.↗

Design, status and test of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The dynamics of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter while aiding the track reconstruction capabilities. The baseline calorimeter configuration consists of two disks each made with ~700 undoped CsI crystals read out by two large area UV-extended Silicon Photomultipliers. Furthermore, these crystals match the requirements for stability of response, high resolution and radiation hardness. In this paper we present the final calorimeter design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Components Qualification for a Possible use in the Mu2e Calorimeter Waveform Digitizer

The Mu2e experiment at Fermilab searches for the charged flavor violating conversion of a muon into an electron in the Coulomb field of a nucleus. The detector consists of a straw tube tracker and a CSI crystal electromagnetic calorimeter, both housed in a superconducting solenoid. Both the front-end and the digital electronics, located inside the cryostat, will be operated in vacuum under a 1 T magnetic field, having to sustain the high flux of neutrons and ionizing particles coming from the muons stopping target. These harsh experimental conditions make the design of the calorimeter waveform digitizer quite challenging. All the selected commercial devices must be tested individually and qualified for radiation hardness and operation in high magnetic field. At the moment the expected particles flux and spectra at the digitizers location are not completely simulated and we are using initial rough estimates to select the components for the first prototype. We are gaining experience in the qualification procedures using the selected components but the choice will be frozen only when dose and neutron flux simulations will be completed. The experimental results of the first qualification campaign are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Wavelength-Shifting Fibers for the Mu2e Cosmic Ray Veto Detector

The cosmic-ray-veto detector (CRV) for the Mu2e experiment consists of four layers of plastic scintillating counters read out by silicon photo-multipliers (SiPM) through wavelength-shifting fibers. This paper reports the light properties of several wavelength-shifting fiber samples with diameters of 1.0 mm, 1.4 mm, and 1.8 mm that were considered for the CRV system. A fiber diameter of 1.4 mm was selected as optimal for the CRV, and measurements of the prototype and production fiber of this diameter are presented. Fiber performance was found to exceed the CRV requirements for >99% of the spools. The measurements are performed using a scanner designed to ensure the fiber quality for the CRV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies on the Magnetic Center of the Mu2e Solenoid System

The definition of the magnetic center in the Mu2e solenoid system is not trivial given the S-shaped nature of the transport solenoid. Moreover, due to the fringe field of the larger bore adjacent magnets-production solenoid and the detector solenoid-the magnetic center does not coincide with the geometric center of the system. The reference magnetic center can be obtained by tracking a low-momentum charged particle through the whole system. This paper will discuss this method and will evaluate the deviations from the nominal magnetic center given the tolerances in the manufacturing and the alignment of the coils. Methods for the correction of the magnetic center will also be presented.

43 PARTICLE ACCELERATORS↗

Thermal design of the Mu2e detector solenoid

The reference design for a superconducting detector solenoid (DS) for the Mu2e experiment has been completed. In this study, the main functions of the DS are to provide a graded field in the region of the stopping target, which ranges from 2 to 1 T and a uniform precision magnetic field of 1 T in a volume large enough to house a tracker downstream of the stopping target. The inner diameter of the magnet cryostat is 1.9 m and the length is 10.9 m. The gradient section of the magnet is about 4 m long and the spectrometer section with a uniform magnetic field is about 6 m long. The inner cryostat wall supports the stopping target, tracker, calorimeter and other equipment installed in the DS. This warm bore volume is under vacuum during operation. It is sealed on one end by the muon beam stop, while it is open on the other end where it interfaces with the Transport Solenoid. The operating temperature of the magnetic coil is 4.7 K and is indirectly cooled with helium flowing in a thermosiphon cooling scheme. This paper describes the thermal design of the solenoid, including the design aspects of the thermosiphon for the coil cooling, forced flow cooling of the thermal shields with 2 phase LN2 (Liquid Nitrogen) and the transient studies of the cool down of the cold mass as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e transport solenoid prototype tests results

The Fermilab Mu2e experiment has been developed to search for evidence of charged lepton flavor violation through the direct conversion of muons into electrons. The transport solenoid is an s-shaped magnet which guides the muons from the source to the stopping target. It consists of fifty-two superconducting coils arranged in twenty-seven coil modules. A full-size prototype coil module, with all the features of a typical module of the full assembly, was successfully manufactured by a collaboration between INFN-Genoa and Fermilab. The prototype contains two coils that can be powered independently. In order to validate the design, the magnet went through an extensive test campaign. Warm tests included magnetic measurements with a vibrating stretched wire, electrical and dimensional checks. As a result, the cold performance was evaluated by a series of power tests as well as temperature dependence and minimum quench energy studies.

43 PARTICLE ACCELERATORS↗

Mu2e transport solenoid prototype design and manufacturing

The Mu2e Transport Solenoid consists of 52 coils arranged in 27 coil modules that form the S-shaped cold mass. Each coil is wound from Al-stabilized NbTi superconductor. The coils are supported by an external structural aluminum shell machined from a forged billet. Most of the coil modules house two coils, with the axis of each coil oriented at an angle of approximately 5° with respect to each other. The coils are indirectly cooled with LHe circulating in tubes welded on the shell. In order to enhance the cooling capacity, pure aluminum sheets connect the inner bore of the coils to the cooling tubes. The coils are placed inside the shell by the means of a shrink-fit procedure. A full-size prototype, with all the features of the full assembly, was successfully manufactured in a collaboration between INFN Genova and Fermilab. In order to ensure an optimal mechanical prestress at the coil-shell interface, the coils are inserted into the shell through a shrink-fitting process. We present the details of the prototype with the design choices as validated by the structural analysis. In conclusion, the fabrication steps are described as well.

43 PARTICLE ACCELERATORS↗

Mu2e Transport Solenoid Cold-Mass Alignment Issues

The Muon-to-electron conversion experiment (Mu2e) at Fermilab is designed to explore charged lepton flavor violation. It is composed of three large superconducting solenoids: the Production Solenoid (PS), the Transport Solenoid (TS) and the Detector Solenoid (DS). The TS is formed by two magnets: TS upstream (TSu) and downstream (TSd). Each has its own cryostat and power supply. Tolerance sensitivity studies of the position and angular alignment of each coil in this magnet system were performed in the past with the objective to demonstrate that the magnet design meets all the field requirements. Furthermore, the alignment of the cold-masses is critical to maximize the transmission of muons and to avoid possible backgrounds that would reduce the sensitivity of the experiment. Each TS magnet cold-mass can be individually aligned. Here, we discuss implications of the alignment of the TS cold-masses in terms of the displacement of the magnetic center. Consideration of the practical mechanical limits are also presented.

43 PARTICLE ACCELERATORS↗

Searches for Sub-GeV Dark Matter with NOvA and LDMX and Performance Studies of the Cosmic-Ray Veto for Mu2e

The constituents of dark matter are still unknown, and the viable possibilities span a very large mass range. Specific scenarios for the origin of dark matter sharpen the focus to within about an MeV to 100 TeV. Most of the stable constituents of known matter have masses in the lower range, and a thermal origin for dark matter works in a simple and predictive manner in this mass range as well. Non-gravitational couplings of dark matter to Standard Model particles would make it possible to produce dark matter at accelerators. Through 120 GeV proton-nucleus collisions, NOvA is effectively a beam dump experiment for producing and detecting dark matter. This thesis presents a search for dark matter – electron scattering in the NOvA near detector from sub-GeV dark matter produced at the target. A future search for sub-GeV dark matter with the Light Dark Matter eXperiment (LDMX) is discussed, along with a study of LDMX's expected sensitivity to visibly decaying dark photons. Additionally, performance studies of the Mu2e cosmic ray veto (CRV) are presented. A calibration procedure for the CRV counters is discussed, along with tests of the efficiency, position resolution, and light yield decline of the CRV counters.

Horoho, Tyler Gregory [Virginia U.] (ORCID:0000000↗

Mu2e Electrostatic Septa Volumetric Exchange of FC-40 Dielectric in High Radiation Environments

Two electrostatic septa (ESS) are being designed for the slow extraction of 8 GeV proton beam for the Mu2e experiment at Fermilab. Special attention is given to the high voltage feedthrough (HVF), which energizes the cathode creating the bending field. The FC-40 dielectric fluid, surrounding the HV cable breaks down from radiation exposure, which reduces its insulating capabilities. The new HVF design focuses on effective replacement of the exposed fluid and eliminating the stagnant areas of low exchange rate. A preliminary test using a fully transparent prototype HVF and water was conducted to understand the volumetric exchange rate of the high radiation region. Here we discuss the results of these tests and further studies using the FC-40.

43 PARTICLE ACCELERATORS↗

Optimizing Mu2e Spill Regulation System Algorithms

A slow extraction system is being developed for the Fermilab’s Delivery Ring to deliver protons to the Mu2e experiment. During the extraction, the beam on target experiences small intensity variations owing to many factors. Various adaptive learning algorithms will be employed for beam regulation to achieve the required spill quality. We discuss here preliminary results of the slow and fast regulation algorithms validation through the computer simulations before their implementation in the FPGA. Particle tracking with sextupole resonance was used to determine the fine shape of the spill profile. Fast semi-analytical simulation schemes and Machine Learning models were used to optimize the fast regulation loop.

43 PARTICLE ACCELERATORS↗