Search NASA⌕ Search

SEARCH · Search NASA

Results for “NIST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Survey of Fire Detection Technologies and System Evaluation/Certification Methodologies and Their Suitability for Aircraft Cargo Compartments

As part of the National Aeronautics and Space Administration (NASA) initiated program on global civil aviation, NIST is assisting Federal Aviation Administration in its research to improve fire detection in aircraft cargo compartments. Aircraft cargo compartment detection certification methods have been reviewed. The Fire Emulator-Detector Evaluator (FE/DE) has been designed to evaluate fire detection technologies such as new sensors, multi-element detectors, and detectors that employ complex algorithms. The FE/DE is a flow tunnel that can reproduce velocity, temperature, smoke, and Combustion gas levels to which a detector might be exposed during a fire. A scientific literature survey and patent search have been conducted relating to existing and emerging fire detection technologies, and the potential use of new fire detection strategies in cargo compartment areas has been assessed. In the near term, improved detector signal processing and multi-sensor detectors based on combinations of smoke measurements, combustion gases and temperature are envisioned as significantly impacting detector system performance.

Cleary, T.↗

Atmospheric and Spectroscopic Research in the Far Infrared

The spectroscopic measurements of molecular parameters constitute one of the major areas of our research program. This part of our program has been conducted in close collaboration with Smithsonian Astrophysical Observatory (SAO) and National Institute of Standards and Technology (NIST). The references on HO2, OH, and O2 that appear on the publication list are examples of this type of work completed during the grant period. These pressure-broadening studies have provided the kind of improvements needed in the database for retrieving atmospheric profiles from far infrared limb sensing data. Authors summarized the laboratory spectroscopic studies conducted during the grant period. We attempted to measure the pressure broadening coefficients of the O2 lines in the 50 and 117/ cm regions. An accurate characterization of these lines using the IBEX detector system was needed to analyze the flight data. These are difficult lines to measure because they arise from weak magnetic dipole transitions. We used a 4-meter absorption cell to obtain the pressure broadening coefficients for the 50 and 83 /cm lines. We also completed the pressure broadening studies including the temperature dependence of two lines of OH at 83 and 118 /cm. These two lines are important not only for the balloon data retrieval work but also for the future project proposals.Another area of focus in our program is the far infrared detector research. The third area of focus deals with data distribution and dissemination.

Park, Kwangjai↗

Intercomparison of Laboratory Radiance Calibration Standards

Several standards for radiometric calibration were measured repeatedly with a spectroradiometer in order to understand how they compared in accuracy and stability. The tested radiance standards included a NIST 1000 W bulb and halon panel, two calibrated and stabilized integrating spheres, and a cavity blackbody. Results indicate good agreement between the blackbody and 1000 W bulb/spectralon panel, If these two radiance sources are assumed correct, then the integrating spheres did not conform. to their manufacturer-reported radiances in several regions of the spectrum. More detailed measurements am underway to investigate the discrepancy.

Pavri, Betina↗

A Technology Demonstration Experiment for Laser Cooled Atomic Clocks in Space

We have been developing a laser-cooling apparatus for flight on the International Space Station (ISS), with the intention of demonstrating linewidths on the cesium clock transition narrower than can be realized on the ground. GLACE (the Glovebox Laser- cooled Atomic Clock Experiment) is scheduled for launch on Utilization Flight 3 (UF3) in 2002, and will be mounted in one of the ISS Glovebox platforms for an anticipated 2-3 week run. Separate flight definition projects funded at NIST and Yale by the Micro- gravity Research Division of NASA as a part of its Laser Cooling and Atomic Physics (LCAP) program will follow GLACE. Core technologies for these and other LCAP missions are being developed at JPL, with the current emphasis on developing components such as the laser and optics subsystem, and non-magnetic vacuum-compatible mechanical shutters. Significant technical challenges in developing a space qualifiable laser cooling apparatus include reducing the volume, mass, and power requirements, while increasing the ruggedness and reliability in order to both withstand typical launch conditions and achieve several months of unattended operation. This work was performed at the Jet Propulsion Laboratory under a contract with the National Aeronautics and Space Administration.

Klipstein, W. M.↗

Endpoint Security Using Biometric Authentication for Secure Remote Mission Operations

We propose a flexible security authentication solution for the spacecraft end-user, which will allow the user to interact over Internet with the spacecraft, its instruments, or with the ground segment from anywhere, anytime based on the user's pre-defined set of privileges. This package includes biometrics authentication products, such as face, voice or fingerprint recognition, authentication services and procedures, such as: user registration and verification over the Internet and user database maintenance, with a configurable schema of spacecraft users' privileges. This fast and reliable user authentication mechanism will become an integral part of end-to-end ground-to-space secure Internet communications and migration from current practice to the future. All modules and services of the proposed package are commercially available and built to the NIST BioAPI standard, which facilitates "pluggability" and interoperability.

Donohue, John T.↗

Performance Monitoring of Distributed Data Processing Systems

Test and checkout systems are essential components in ensuring safety and reliability of aircraft and related systems for space missions. A variety of systems, developed over several years, are in use at the NASA/KSC. Many of these systems are configured as distributed data processing systems with the functionality spread over several multiprocessor nodes interconnected through networks. To be cost-effective, a system should take the least amount of resource and perform a given testing task in the least amount of time. There are two aspects of performance evaluation: monitoring and benchmarking. While monitoring is valuable to system administrators in operating and maintaining, benchmarking is important in designing and upgrading computer-based systems. These two aspects of performance evaluation are the foci of this project. This paper first discusses various issues related to software, hardware, and hybrid performance monitoring as applicable to distributed systems, and specifically to the TCMS (Test Control and Monitoring System). Next, a comparison of several probing instructions are made to show that the hybrid monitoring technique developed by the NIST (National Institutes for Standards and Technology) is the least intrusive and takes only one-fourth of the time taken by software monitoring probes. In the rest of the paper, issues related to benchmarking a distributed system have been discussed and finally a prescription for developing a micro-benchmark for the TCMS has been provided.

Ojha, Anand K.↗

Arctic Gas Phase Water Vapor Measurements from the NASA DC-8 During SOLVE

The NASA Langley / Ames Diode Laser Hygrometer (DLH) was flown aboard the NASA DC-8 during all three arctic deployments of the SOLVE campaign. The DLH measures gas phase H2O in the freestream air between the fuselage and the outer right engine cowling, essentially free from aircraft perturbations. It uses wavelength-modulated near-IR laser radiation at about 1.4 microns to detect the H2O absorption. Calibration is based on short path experiments in the laboratory using a NIST-traceable dewpoint hygrometer with carefully conditioned air at dewpoints between - 10 and + 10 degrees C. The theory of operation of the DLH instrument will be presented, along with a description of the calibration methodology. A simple climatology of H2O observations from SOLVE will be presented.

Podolske, James↗

Mode-Stirred Method Implementation for HIRF Susceptibility Testing and Results Comparison with Anechoic Method

This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.

Nguyen, Truong X.↗

An Overview of NASA's In-Space Cryogenic Propellant Management Technologies

Future mission planning within NASA continues to include cryogenic propellants for in space transportation, with mission durations ranging from days to years. Between 1995 and the present, NASA has pursued a diversified program of ground-based testing to prepare the various technologies associated with in-space cryogenic fluid management (CFM) for implementation. CFM technology areas being addressed include passive insulation, zero gravity pressure control, zero gravity mass gauging, capillary liquid acquisition devices, and zero boiloff storage. NASA CFM technologies are planned, coordinated, and implemented through the Cryogenic Technology Working Group which is comprised of representatives from the various NASA Centers as well as the National Institute of Standards and Technologies (NIST) and, on selected occasions, the Air Force. An overview of the NASA program and Marshall Space Flight Center (MSFC) roles, accomplishments, and near-term activities are presented herein. Basic CFM technology areas being addressed include passive insulation, zero gravity pressure control, zero gravity mass gauging, capillary liquid acquisition devices, and zero boiloff storage. Recent MSFC accomplishments include: the large scale demonstration of a high performance variable density multilayer insulation (MLI) that reduced the boiloff by about half that of standard MLI; utilization of a foam substrate under MLI to eliminate the need for a helium purge bag system; demonstrations of both spray-bar and axial-jet mixer concepts for zero gravity pressure control; and sub-scale testing that verified an optical sensor concept for measuring liquid hydrogen mass in zero gravity. In response to missions requiring cryogenic propellant storage durations on the order of years, a cooperative effort by NASA's Ames Research Center, Glenn Research Center, and MSFC has been implemented to develop and demonstrate zero boiloff concepts for in-space storage of cryogenic propellants. An MSFC contribution to this cooperative effort is a large-scale demonstration of the integrated operation of passive insulation, destratification/pressure control, and cryocooler (commercial unit) subsystems to achieve zero boiloff storage of liquid hydrogen. Testing is expected during the Summer of 2001.

Tucker, Stephen↗

Simulated Space Vacuum Ultraviolet (VUV) Exposure Testing for Polymer Films

Vacuum ultraviolet (VUV) radiation of wavelengths between 115 and 200 nm produced by the sun in the space environment can cause degradation to polymer films producing changes in optical, mechanical, and chemical properties. These effects are particularly important for thin polymer films being considered for ultra-lightweight space structures, because, for most polymers, VUV radiation is absorbed in a thin surface layer. NASA Glenn Research Center has developed facilities and methods for long-term ground testing of polymer films to evaluate space environmental VUV radiation effects. VUV exposure can also be used as part of sequential simulated space environmental exposures to determine combined damaging effects. This paper will describe the effects of VUV on polymer films and the necessity for ground testing. Testing practices used at Glenn Research Center for VUV exposure testing will be described including characterization of the VUV radiation source used, calibration procedures traceable to the National Institute of Standards and Technology (NIST), and testing techniques for VUV exposure of polymer surfaces.

Dever, Joyce A.↗

Modeling Orifice Pulse Tube Coolers

We have developed a calculational model that treats all the components of an orifice pulse tube cooler. We base our analysis on 1-dimensional thermodynamic equations for the regenerator and we assume that all mass flows, pressure oscillations and temperature oscillations are small and sinusoidal. Non-linear pressure drop effects are included in the regenerator to account for finite pressure amplitude effects. The resulting mass flows and pressures are matched at the boundaries with the other components of the cooler: compressor, aftercooler, cold heat exchanger, pulse tube, hot heat exchanger, orifice and reservoir. The results of the calculation are oscillating pressures, mass flows and enthalpy flows in the main components of the cooler. By comparing with the calculations of other available models, we show that our model is very similar to REGEN 3 from NIST and DeltaE from Los Alamos National Lab. Our model is much easier to use than other available models because of its simple graphical interface and the fact that no guesses are required for the operating pressures or mass flows. In addition, the model only requires a few minutes of running time allowing many parameters to be optimized in a reasonable time. A version of the model is available for use over the World Wide Web at http://irtek.arc.nasa.gov. Future enhancements include adding a bypass orifice and including second order terms in steady mass streaming and steady heat transfer. A two-dimensional anelastic approximation of the fluid equations will be used as the basis for the latter analysis. Preliminary results are given in dimensionless numbers appropriate for oscillating compressible flows. The model shows how transverse heat transfer reduces enthalpy flow, particularly for small pulse tubes. The model also clearly shows mass recirculation in the open tube on the order of the tube length. They result from the higher order Reynolds stresses. An interesting result of the linearized approach is that the steady mass streaming does not affect the enthalpy flow at second order. The major effect of recirculating mass streaming is to increase transverse temperature gradients, which leads to higher entropy production and reduced efficiency.

Roach, Kittel P.↗

The Seventh SeaWiFS Intercalibration Round-Robin Experiment (SIRREX-7), March 1999

This report documents the scientific activities during the seventh SeaWiFS Intercalibration Round-Robin Experiment (SIRREX-7) held at Satlantic, Inc. (Halifax, Canada). The overall objective of SIRREX-7 was to determine the uncertainties of radiometric calibrations and measurements at a single calibration facility. Specifically, this involved the estimation of the uncertainties in a) lamp standards, b) plaque standards (including the uncertainties associated with plaque illumination non-uniformity), c) radiance calibrations, and d) irradiance calibrations. The investigation of the uncertainties in lamp standards included a comparison between a calibration of a new FEL by the National Institute of Standards and Technology (NIST) and Optronic Laboratories, Inc. In addition, the rotation and polarization sensitivity of radiometers were determined, and a procedure for transferring an absolute calibration to portable light sources was defined and executed.

Hooker, Stanford B.↗

Calibration and Data Retrieval Algorithms for the NASA Langley/Ames Diode Laser Hygrometer for the NASA Trace-P Mission

This paper describes the procedures and algorithms for the laboratory calibration and the field data retrieval of the NASA Langley / Ames Diode Laser Hygrometer as implemented during the NASA Trace-P mission during February to April 2000. The calibration is based on a NIST traceable dewpoint hygrometer using relatively high humidity and short pathlength. Two water lines of widely different strengths are used to increase the dynamic range of the instrument in the course of a flight. The laboratory results are incorporated into a numerical model of the second harmonic spectrum for each of the two spectral window regions using spectroscopic parameters from the HITRAN database and other sources, allowing water vapor retrieval at upper tropospheric and lower stratospheric temperatures and humidity levels. The data retrieval algorithm is simple, numerically stable, and accurate. A comparison with other water vapor instruments on board the NASA DC-8 and ER-2 aircraft is presented.

Podolske, James R.↗

Heat Flux Sensor Testing

This viewgraph presentation provides information on the following objectives: Developing secondary calibration capabilities for MSFC's (Marshall Space Flight Center) Hot Gas Facility (HGF), a Mach 4 Aerothermal Wind Tunnel; Evaluating ASTM (American Society for Testing and Materials) slug/ thinskin calorimeters against current HGF heat flux sensors; Providing verification of baselined AEDC (Arnold Engineering Development Center) / Medtherm gage calibrations; Addressing future calibration issues involving NIST (National Institute of Standards and Technology) certified radiant gages.

Clark, D. W.↗

Spectroscopic Determination of the Physical Conditions in Hot Optically Thin Sources

The Astrophysics Plasma Emission Code and Database (APEC/APED), developed in part under this grant, have been upgraded to Version 1.3.0 and are now beginning to find widespread applications to X-ray spectral data from Chandra and XMM-Newton. These models represent the best theoretical data currently available and are reasonably complete below about 30 A. We are making significant progress in improving the spectral models between 30 and 90 A, by the addition of HULLAC calculations and NIST wavelengths for L-shell ions of Ne, Mg, Si, S, Ar, and Ca. While the output models are now public, the code itself is not ready for public release. We have made significant progress toward this goal through programming improvements, including optimized error codes, a major (elusive) bug fix, and additions to our testing protocols. Secondarily, we are beginning to investigate limited uses of APEC for X-ray photoionized plasma, as for opacity modeling. Stellar coronae are being used to benchmark the atomic data in APED as part of the Emission Line Project. The models appear to be in good agreement with the observations for most of the strong lines; however, we have identified significant discrepancies in the 3s/3d line ratios not only for Fe XVII, but also for Fe XVIII and XIX. The careful analysis of these high quality X-ray spectra has also shown that there are serious problems with some of the analysis techniques in widespread use. There are several manifestations of the problem, but the main problem is that line-to-continuum ratios may be seriously mismeasured. We continue to collaborate widely with atomic physicists in order to find the best atomic data, and to solicit calculations and measurements that are needed.

Brickhouse, Nancy↗

Properties of the -513 km/s Ejecta in the Spectrum of Eta Carinae

In the spectral region 2400-3160A of Eta Carinae, we have identified approximately 500 absorption lines each with up to twenty velocity components. The -512 kilometers per second component is truely unique as 1) the typical line width is less than 3 kilometers per second, 2) the identified lines are in Fe I, Fe II, V II and Ti II, and 3) the lines originate from lower levels up to 2000 cm-1 above the ground level. We have measured the velocity centers, full width at half maximum and equivalent widths for approximately 100 absorption lines. Initial results were very confusing as we found more variation in central velocities than would be expected from known STIS echelle wavelength standards. Upon further review, we found that the reporteded wavelengths in the NIST and Kurucz databases were not sufficiently accurate. S. Johansson searched FTS laboratory measurements performed at Lund for V II and Ti II and provided much improved wavelength measures. Likewise, we find more variation in column density than expected statistically from the accuracy of the equivalent widths for lines originating from the same energy level. We are reviewing the published gf values and our measurements to improve the measured column densities. Some spectroscopy of the ejecta has already been accomplished at two different epochs. Preliminary measures of equivalent widths indicate there may be some variation with time, but we await measurements planned for July 2003 during the upcoming spectroscopic minimum of Eta Carinae. These observations were accomplished through STScI and funding was from STIS GTO resources.

Danks, Anthony↗

A Generalized Multi-Phase Framework for Modeling Cavitation in Cryogenic Fluids

A generalized multi-phase formulation for cavitation in fluids operating at temperatures elevated relative to their critical temperatures is presented. The thermal effects and the accompanying property variations due to phase change are modeled rigorously. Thermal equilibrium is assumed and fluid thermodynamic properties are specified along the saturation line using the NIST-12 databank. Fundamental changes in the physical characteristics of the cavity when thermal effects become pronounced are identified; the cavity becomes more porous, the interface less distinct, and has increased entrainment when temperature variations are present. Quantitative estimates of temperature and pressure depressions in both liquid nitrogen and liquid hydrogen were computed and compared with experimental data of Hord for hydrofoils. Excellent estimates of the leading edge temperature and pressure depression were obtained while the comparisons in the cavity closure region were reasonable. Liquid nitrogen cavities were consistently found to be in thermal equilibrium while liquid hydrogen cavities exhibited small, but distinct, non-equilibrium effects.

Dorney, Dan↗

High Accuracy Thermal Expansion Measurement At Cryogenic Temperatures

A new, interferometer based system for measuring thermal expansion to an absolute accuracy of 20 ppb or better at cryogenic temperatures has been developed. Data from NIST Copper SRM 736 measured from room temperature to 15 K will be presented along with data from many other materials including beryllium, ULE, Zerodur, and composite materials. Particular attention will be given to a study by the Space Optics Manufacturing Technology Center (SOMTC) investigating the variability of ULE and beryllium materials used in the AMSD program. Approximately 20 samples of each material, tested from room temperature to below 30 K are compared as a function of billet location.

Stallcup, Michael↗