Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Analysis of the neutron time-of-flight spectra from inertial confinement fusion experiments

Neutron time-of-flight diagnostics have long been used to characterize the neutron spectrum produced by inertial confinement fusion experiments. The primary diagnostic goals are to extract the d + t → n + α (DT) and d + d → n + {sup 3}He (DD) neutron yields and peak widths, and the amount DT scattering relative to its unscattered yield, also known as the down-scatter ratio (DSR). These quantities are used to infer yield weighted plasma conditions, such as ion temperature (T{sub ion}) and cold fuel areal density. We report on novel methodologies used to determine neutron yield, apparent T{sub ion}, and DSR. These methods invoke a single temperature, static fluid model to describe the neutron peaks from DD and DT reactions and a spline description of the DT spectrum to determine the DSR. Both measurements are performed using a forward modeling technique that includes corrections for line-of-sight attenuation and impulse response of the detection system. These methods produce typical uncertainties for DT T{sub ion} of 250 eV, 7% for DSR, and 9% for the DT neutron yield. For the DD values, the uncertainties are 290 eV for T{sub ion} and 10% for the neutron yield.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Design of a New Pulsed-Neutron Die--Away Experiments with Absorbers (IER-552 CED-1)

This report presents the preliminary design (CED-1) of IER-552, pulsed-neutron die-away (PNDA) experiments with absorbers, to be conducted by Lawrence Livermore National Laboratory (LLNL). The goal of the PNDA experiments with absorbing materials is to produce high-quality, low-cost integral benchmarks that can be used to validate cross sections that are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). PNDA experiments can be used to generate nuclear data validation benchmarks quickly and cheaply, as they do not require fissile material or a nuclear facility to conduct them. The original PNDA experiments were set up at LLNL under IER-501. Extending the PNDA experiments to include absorbing materials leverages existing facilities and resources at LLNL to validate cross sections, with a basic experiment design that uses a neutron generator to impinge a short, mono-energetic neutron pulse on a poisoned, moderating target sample. The neutron pulse lasts 100 µs, after which the neutron population in the sample reaches thermal equilibrium and later spatial equilibrium. In this fully equilibrized state, the neutron population has a characteristic decay-time eigenvalue. The eigenvalue can be used as an integral parameter to validate nuclear data involved with neutron scattering and absorption. Two observables can be measured: the neutron population and the population of secondary γ-rays produced by inelastic and capture reactions. This report explores the feasibility of both approaches. For γ-ray measurements, this allows for direct measurement of reactions of interest for validation. During the neutron burst time, inelastic (prompt) γ-rays dominate, and these data can be isolated for validation of neutron inelastic scattering data. After the pulse ends, neutron capture (delayed) γ-rays dominate and are produced by many reaction channels as neutrons slow down to thermal energies. Two sets of γ-ray spectra (inelastic, capture) can be produced for validation. Additionally, the time-dependent decay of the capture γ-ray population when the neutron population is thermalized and in its fundamental mode can be used for validation. Two experiments can be imagined where pulsed neutrons are used to validate the nuclear data of absorbing materials. The first integrates well into the existing PNDA testbed at LLNL. The absorber material would be introduced into a moderating target and the same neutron generator, neutron detectors, electronics, and shielding box used for IER-501 would be employed. From the same experimental setup, many absorbing materials can be validated by simply changing the neutron poison in the moderator. The only significant modification would be the introduction of a γ-ray detector. Such an experiment would primarily serve to validate nuclear data in the thermal energy range. The second kind of experiment would validate the fast and epithermal energy range. It would involve pulsing neutron into a bare assembly of the absorber material and measuring the die-away of neutrons. The fast leakage of such an assembly requires nanosecond neutron-generator pulse widths and fast detectors/electronics that could measure ~200 ns die-away curves. This kind of experiment would ideally be performed at a cyclotron, like that available at Lawrence Berkeley National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Possible Neutron-Antineutron Oscillation Experiment at PF1B at the Institut Laue Langevin

We consider a possible neutron–antineutron ($n-\overline{n}$) oscillation experiment at the PF1B instrument at Institut Laue Langevin. It can improve the best existing constraint on the transition rate and also allow the testing of the methods and instrumentation which would be needed for a later larger-scale experiment at ESS. The main gain factors over the most competitive experiment, performed earlier at PF1 instrument at ILL, are: a more intense neutron beam and a new operating mode based on coherent n and $\overline{n}$ mirror reflections. The installation of such an experiment would need a temporary replacement of the existing ballistic neutron guide by a specially designed n/$\overline{n}$ guide with a gradually increasing cross section and a specially selected coating as well as the development and construction of an advanced $\overline{n}$ annihilation detector with a high efficiency and low background. The overall gain factor could reach up to an order of magnitude and depends on the chosen experiment configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity Analysis of H 2 O Pulsed Neutron Die Away Experiments to the H-H 2 O Thermal Scattering Law

Lawrence Livermore National Laboratory is conducting new Pulsed-Neutron Die-Away (PNDA) benchmark experiments to validate neutron thermal scattering laws (TSLs). TSLs are important data for modeling thermal fission reactors, criticality safety scenarios, and radiation protection and detection, i.e. any application with thermal neutrons. These simulations require high-quality nuclear data, with confidence in their quality established through validation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data-Driven and Precursor-Group Uncertainty Propagation of Lattice Kinetic Parameters in UAM Benchmark

A new data-driven sampling-based framework was developed for uncertainty quantification (UQ) of the homogenized kinetic parameters calculated by lattice physics codes such as TRITON and Polaris. In this study, extension of the database for the delayed neutron data (DND) is performed by exploring more delayed neutron experiments and adding additional isotopes/actinides to the data libraries. Afterwards, the framework is utilized to obtain a deeper knowledge of the kinetic parameters’ sensitivity and uncertainty. The kinetic parameters include precursor-group-wise delayed neutron fraction (DNF) and decay constant. Input uncertainties include nuclear data (i.e., cross-sections) and DND (i.e., precursor group parameters and fractional delayed neutron yield). It is found that kinetic parameters, especially DNFs, have large uncertainties. The DNF uncertainty is driven by the cross-section uncertainties for LWR designs, while decay constant uncertainty is dominated by the DND uncertainties. The usage of correlated U-235 thermal DND in the UQ process significantly reduces the DND uncertainty contribution on the kinetic parameters. Large void fraction and presence of neutron absorber (e.g., control rod) increase the DNF uncertainty due to the hardening of neutron spectrum. High correlation between the DNF groups ( β 1 , . . , β 6 ) is observed, while the decay constant groups ( λ 1 , . . , λ 6 ) show weak correlation to each other and also to DNF groups. The DNF uncertainties of the dominant precursor group 4 for PWR, BWR, and VVER are about 7.5%, 9.4%, and 7.6%, respectively. The DNF uncertainty grows to larger values after fuel burnup. Kinetic parameters’ values and uncertainties provided here can be efficiently used in subsequent core calculations, point reactor kinetics, and other applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Automatic information extraction from neutron radiography imaging to estimate axial fuel expansion in $\mathrm{EBR-II}$

Approximately 130,000 metal fuel pins were irradiated in the Experimental Breeder Reactor II (EBR-II) during its 30 years of operation to develop and characterize existing and prospective fuels. For many of the metal fuel irradiation experiments, neutron radiography imaging was performed to characterize fuel behavior, like fuel swelling. However, due to the lack of technology or resources, many of the images have not been processed or were processed manually through visual examination. This paper represents first-attempt to develop an image processing algorithm capable of automatically extracting information regarding the degree of fuel swelling from neutron radiography imaging. The algorithm was applied to 120 images of three different metallic fuel pin compositions—U-10Zr, U-8Pu-10Zr, and U-19Pu-10Zr. The algorithm performs operations of image intensity adjustment, image binarization, region finding, and labeling to extract information about fuel swelling. The average growth for U-10Zr was found to be 8.49% with 95% Confidence Interval (CI) [8.33 –8.66%], for U-8Pu-10Zr — 7.50% with 95% CI [7.23 – 7.78%], and for U-19Pu-10Zr — 3.15%, with 95% CI [2.40 – 3.91%]. The results obtained by applying this automatic image processing algorithm are consistent with previously reported studies of the same types of fuels. The automatic image processing algorithm will be expanded to include thousands of available neutron radiography images and different types of fuels to investigate empirical dependencies of fuel swelling, which can be subsequently applied to advanced fuel modeling. Results from this study can later be compared to BISON simulations to further benchmark modeling efforts and develop assessment cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER 501: Pulsed Neutron Die-Away Experiments at LLNL [Slides]

Pulsed neutron die away experiments occur as follows: (1) a pulse of neutrons is injected into a target material via a D-T neutron generator, (2) neutrons thermalize, (3) neutrons spatially equilibrate, and (4) exponential decay is measured in fundamental mode.

43 PARTICLE ACCELERATORS↗

Spin canting and orbital order in spinel vanadate thin films

Here, we report on the epitaxial film growth and characterization of CoV 2 O 4 , a near-itinerant spinel vanadate, grown on (001) SrTiO 3 . The symmetry lowering of the unit cell from cubic in the bulk to orthorhombic in the films results in dramatic differences in the magnetic anisotropy compared to bulk, as determined from structural and magnetic characterization. Bulk cubic CoV 2 O 4 has been found to defy predictions by showing orbital degeneracy seemingly lasting to very low temperatures, with only small anomalies in magnetization and neutron experiments signaling a possible spin/orbital glass transition at T = 90 K. In epitaxial thin films presented in this paper, structurally tuning the CoV 2 O 4 away from cubic symmetry leads to a completely different low temperature noncollinear ground state. Via magnetization and neutron scattering measurements we show that the 90-K transition is associated with a major spin reorientation away from the ferrimagnetic easy axis [001] to the [110] direction. Furthermore, the V spins cant away from this direction with extracted perpendicular moments providing evidence of a larger canting angle compared to bulk. This result indicates that compressive strain pushes the system deeper into the insulating state, i.e., away from the localized-itinerant crossover regime.

36 MATERIALS SCIENCE↗

A super-resolution technique to analyze single-crystal inelastic neutron scattering measurements using direct-geometry chopper spectrometers

Direct-geometry time-of-flight chopper neutron spectroscopy is instrumental in studying dynamics in liquid, powder, and single crystal systems. We report here that real-space techniques in optical imagery can be adapted to obtain reciprocal-space super resolution dispersion for phonon or magnetic excitations from single-crystal neutron spectroscopy measurements. The procedure to reconstruct super-resolution energy dispersion of excitations relies on an accurate determination of the momentum and energy-dependent point spread function and a dispersion correction technique inspired by an image disparity calculation technique commonly used in stereo imaging. Here by, applying these methods to spinwave dispersion data from a virtual neutron experiment demonstrates ~5-fold improvement over nominal energy resolution.

47 OTHER INSTRUMENTATION↗

Particle Swarm Optimisation for group structure optimization for radiotherapy shielding

Neutron transport simulations are ubiquitous in nuclear engineering because they allow one to model experimental systems and render a model platform for easy perturbation of experimental designs. In addition, simulations allow one to gain experimental insight without actually having to go through the trouble of building a physical experiment. Neutron transport simulations can be stochastic or deterministic based. Stochastic neutron transport simulations are typically simulated using the Monte Carlo method and yield very accurate solutions but are computationally expensive, while deterministic methods are typically faster but can be less accurate. Here we focus on optimizing the accuracy of deterministic neutron transport simulations for radiotherapy simulations. Deterministic neutron transport requires discretization of angle, energy, and space to appropriately analyze the system one is trying to model. Discretization of energy is challenging because of the highly variable neutron flux at certain neutron energies. Improper discretization of energy in the transport model can lead to erroneous results and therefore inaccurate interpretations of the solution. In this study, we evaluate Particle Swarm Optimization (PSO) as a mechanism for selecting optimal group structures for radiotherapy shielding. We tested the particle swarm optimization algorithm on radiotherapy shielding problems using Los Alamos National Laboratory's (LANL) main deterministic transport code PARTISN. Results show that the optimized energy group structures generated from the optimization algorithm outperformed LANL's standard energy group structures, and therefore demonstrate utility in using PSO to expedite computation times due to the increased accuracy obtained with a smaller but optimized group structure. (authors)

43 PARTICLE ACCELERATORS↗

From Interfaces to Bulk: Experimental-Computational Studies Across Time and Length Scales of Multi-Functional Ionic Polymers

Neutron experiments coupled with computational components have resulted in unprecedented understanding of the factors that impact the behavior of ionic structured polymers. Additionally, new computational tools to study macromolecules, were developed. In parallel, this DOE funding have enabled the education of the next generation of material researchers who are able to take the advantage neutron tools offer to the understanding and design of advanced materials. Our research has provided unprecedented insight into one of the major factors that limits the use of ionizable polymers, combining the macroscopic view obtained from the experimental techniques with molecular insight extracted from computational studies leading to transformative knowledge that will impact the design of nano-structured, materials. With the focus on model systems, of broad interest to the scientific community and to industry, the research addressed challenges that cut across a large number of polymers, independent of the specific chemical structure or the transported species.

36 MATERIALS SCIENCE↗

Intrinsic value of the international benchmark projects, ICSBEP and IRPhEP, for advanced reactor development

The International Criticality Safety Benchmark Evaluation Project, a sanctioned program under the auspices of the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development, has been a highly successful and productive collaboration, now encompassing over 5,000 evaluated experimental benchmarks trusted and relied upon throughout the international nuclear communities. The success of this project led to the development of the International Reactor Physics Experiment Evaluation Project, which is dedicated to the evaluation of benchmark experiment data to sustain current and future reactor physics validation needs. These exemplary programs, and their widely utilized handbooks, serve as gold standards to which other databases strive to emulate. The purpose of the two projects is to preserve modern and legacy experimental data and evaluate it in a standardized handbook format to provide quality benchmarks to support modern and future criticality safety and reactor physics validation. These two projects have often served as the mechanism through which historic and modern neutronics experiments are evaluated and shared across international borders, to best provide unique, high-quality peer-reviewed, and often otherwise unavailable, benchmark data. The contents of these handbooks are utilized not only in validating criticality safety, reactor physics, and advanced reactor calculations, but are used to validate neutronics calculations and nuclear data for most other nuclear applications. This paper discusses both international programs and available content to enable advanced reactor design validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of the parity-violating triton emission asymmetry in the reaction {sup 6}Li(n,{alpha}){sup 3}H with polarized cold neutrons

We describe measurements of the parity-violating (P-odd) triton emission asymmetry coefficient a{sub P-odd} in the {sup 6}Li(n,{alpha}){sup 3}H reaction with polarized cold neutrons. Experiments were carried out at the Petersburg Nuclear Physics Institute (Gatchina, Russia) and at the Institut Laue-Langevin (Grenoble, France). We employed an ionisation chamber in a configuration allowing us to suppress the left-right asymmetry well below 10{sup -8}. An additional test for a false asymmetry due to eventual target impurities (''zero test'') resulted in a{sub 0-test}=(0.0{+-}0.5)x10{sup -8}. As final result of this series of experiments we obtained a{sub P-odd}=(-8.8{+-}2.1)x10{sup -8}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Neutron Emission Rates of Commercial 252 Cf Sources

Accurate knowledge of 252 Cf neutron emission rates is critical for modeling and fast-neutron experiments, yet commercial sources are often supplied without traceable calibration or uncertainty estimates. This report describes a method to characterize 252 Cf sources using a pulse-shape-discrimination (PSD) scintillator. The scintillator was efficiency-calibrated against a time-tagged 252 Cf fission chamber manufactured at ORNL over 40 years ago. Isotopic evolution of the calibration source was modeled using Bateman equations to account for changes in the effective average neutrons per fission at the time of measurement. The calibrated scintillator was then used to measure absolute emission rates of several commercial 252 Cf sources, revealing deviations of up to 12% from nominal manufacturer values. This methodology provides a practical approach for establishing uncertainty-quantified 252 Cf neutron emission rates, improving fidelity in simulations and supporting the accurate interpretation of measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗