At least 199 records · Page 11

Summary of the Effort to Use Active-induced Time Correlation Techniques to Measure the Enrichment of HEU

This document summarizes the effort to use active-induced time correlation techniques to measure the enrichment of bulk quantities of enriched uranium. In summary, these techniques use an external source to initiate fission chains, and the time distribution of the detected fission chain neutrons is sensitive to the fissile material enrichment. The number of neutrons emitted from a chain is driven by the multiplication of the item, and the enrichment is closely coupled to the multiplication of the item. As the enrichment increases (decreases), the multiplication increases (decreases) if the geometry is held constant. The time distribution of fission chain neutrons is a complex function of the enrichment and material configuration. The enrichment contributes to the probability of a subsequent fission in a chain via the likelihood of fissioning on an even-numbered isotope versus an odd-numbered isotope. The material configuration contributes to the same probability via solid angle effects for neutrons inducing subsequent fissions and the presence of any moderating material. To simplify the ability to accurately measure the enrichment, an associated particle imaging (API) D-T neutron generator and an array of plastic scintillators are used to simultaneously image the item and detect the fission chain neutrons. The image is used to significantly limit the space of enrichment and material configuration and enable the enrichment to be determined unambiguously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraining a possible time variation of the gravitational constant G with terrestrial nuclear laboratory data

Testing the constancy of the gravitational constant G is a longstanding fundamental question in natural science. As first suggested by Jofre, Reisenegger, and Fernandez (2006, Phys. Rev. Lett. 97, 131102), Dirac's hypothesis of a decreasing gravitational constant G with time caused by the expansion of the Universe would induce changes in the composition of neutron stars, causing dissipation and internal heating. Eventually, neutron stars reach their quasistationary states where cooling, as a result of neutrino and photon emissions, balances the internal heating. The correlation of surface temperatures and radii of some old neutron stars may thus carry useful information about the rate of change of G. Using the density dependence of the nuclear symmetry energy, constrained by recent terrestrial laboratory data on isospin diffusion in heavy-ion reactions at intermediate energies, and the size of neutron skin in {sup 208}Pb, within the gravitochemical heating formalism developed by Jofre et al. (2006, Phys. Rev. Lett. 97, 131102), we obtain an upper limit for the relative time variation |G{center_dot}/G| in the range (4.5-21)x10{sup -12} yr{sup -1}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulsed, Photonuclear-induced, Neutron Measurements of Nuclear Materials with Composite Shielding

Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Feynman-Y Statistic in Relation to Shift-Register Neutron Coincidence Counting: Precision and Dead Time

The Feynman-Y statistic is a type of autocorrelation analysis. It is defined as the excess variance-to-mean ratio, Y = VMR - 1, of the number count distribution formed by sampling a pulse train using a series of non-overlapping gates. It is a measure of the degree of correlation present on the pulse train with Y = 0 for Poisson data. In the context of neutron coincidence counting we show that the same information can be obtained from the accidentals histogram acquired using the multiplicity shift-register method, which is currently the common autocorrelation technique applied in nuclear safeguards. In the case of multiplicity shift register analysis however, overlapping gates, either triggered by the incoming pulse stream or by a periodic clock, are used. The overlap introduces additional covariance but does not alter the expectation values. In this paper we discuss, for a particular data set, the relative merit of the Feynman and shift-register methods in terms of both precision and dead time correction. Traditionally the Feynman approach is applied with a relatively long gate width compared to the dieaway time. The main reason for this is so that the gate utilization factor can be taken as unity rather than being treated as a system parameter to be determined at characterization/calibration. But because the random trigger interval gate utilization factor is slow to saturate this procedure requires a gate width many times the effective 1/e dieaway time. In the traditional approach this limits the number of gates that can be fitted into a given assay duration. We empirically show that much shorter gates, similar in width to those used in traditional shift register analysis can be used. Because the way in which the correlated information present on the pulse train is extracted is different for the moments based method of Feynman and the various shift register based approaches, the dead time losses are manifested differently for these two approaches. The resulting estimates for the dead time corrected first and second order reduced factorial moments should be independent of the method however and this allows the respective dead time formalism to be checked. We discuss how to make dead time corrections in both the shift register and the Feynman approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Fissile Materials through Primary Cosmic Ray Interactions

Experiments performed by an LLNL team at the White Mountain Research center discovered that primary cosmic ray interactions on high-Z material produced large bursts of correlated neutrons. In fissionable material, these neutrons will start fission chains enhancing the neutron signature with a characteristic time signature. This signature could be a unique method for discovering fissionable material in challenging environments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification Data Pattern Recognition and Change Detection at the Neutron Instrument Level

As the pressure on International Atomic Energy Agency (IAEA) safeguards resources increases, there is a drive to essentially “do more with less.” New ways of using current verification instrumentation and visualizing the collected data are needed, coupled with maintaining and sustaining the current safeguards instrumentation fleet. This paper explores how to innovate with current safeguards neutron instrumentation using data-driven algorithms at the instrument level. A concept is described for upgrading current neutron counting systems with modern electronics by leveraging electronics developments in other fields (e.g., high-energy physics) to facilitate full list mode data acquisition and, therefore, expand existing analyses to pattern recognition and change detection at the instrument level. The aim is to advance correlated neutron counting by improving the reliability of detecting nuclear material diversion and, at the same time, to improve the sustainability of those systems. It is likely that upgrading existing systems with new hardware and software is more cost-effective than replacing systems with other novel systems that might meet this need. A specific project example is highlighted in which a system was upgraded by retrofitting the standard uranium neutron collar detector with new electronics; as a result, verification data can be analyzed in new ways. A new neutron analysis method, the “List Mode Response Matrix,” has been developed to analyze every pulse train from the detector array and thus enable the verification of spatial information about the assay item for safeguards inspections. This project has improved the reliability of resolving individual fuel pin locations within a given fresh fuel assembly and the percentage of partial defects detected. Herein, the overall concept of upgrading current neutron counting systems is discussed with respect to the potential increase in analysis capabilities. In addition, the details and results of the list mode collar project are discussed.

Worrall, Louise G.↗

Real-space local self-motion of protonated and deuterated water

Here, we report on the self-part of the Van Hove correlation function, the correlation function describing the dynamics of a single molecule, of water and deuterated water. The correlation function is determined by transforming inelastic scattering spectra of neutrons or x rays over a wide range of momentum transfer Q and energy transfer E to space R and time t. The short-range diffusivity is estimated from the Van Hove correlation function in the framework of the Gaussian approximation. The diffusivity has been found to be different from the long-range macroscopic diffusivity, providing information about local atomic dynamics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlated Temporal and Spectral Variability

The variability of neutron star and black hole X-ray sources has several dimensions, because of the roles played by different important time-scales. The variations on time scales of hours, weeks, and months, ranging from 50% to orders of magnitude, arise out of changes in the flow in the disk. The most important driving forces for those changes are probably various possible instabilities in the disk, though there may be effects with other dominant causes. The changes in the rate of flow appear to be associated with changes in the flow's configuration, as the accreting material approaches the compact object, for there are generally correlated changes in both the Xray spectra and the character of the faster temporal variability. There has been a lot of progress in tracking these correlations, both for Z and Atoll neutron star low-mass X-ray binaries, and for black hole binaries. I will discuss these correlations and review briefly what they tell us about the physical states of the systems.

Swank, Jean H.↗

Real-space investigation of short-range magnetic correlations in fluoride pyrochlores NaCaCo 2 F 7 and NaSrCo 2 F 7 with magnetic pair distribution function analysis

Here, we present time-of-flight neutron total scattering and polarized neutron scattering measurements of the magnetically frustrated compounds NaCaCo 2 F 7 and NaSrCo 2 F 7 , which belong to a class of recently discovered pyrochlore compounds based on transition metals and fluorine. The magnetic pair distribution function (mPDF) technique is used to analyze and model the total scattering data in real space. We find that a previously-proposed model of short-range XY-like correlations with a length scale of 10-15 Å, combined with nearest-neighbor collinear antiferromagnetic correlations, accurately describes the mPDF data at low temperature, confirming the magnetic ground state in these materials. This model is further verified by the polarized neutron scattering data. From an analysis of the temperature dependence of the mPDF and polarized neutron scattering data, we find that short-range correlations persist on the nearest-neighbor length scale up to 200 K, approximately two orders of magnitude higher than the spin freezing temperatures of these compounds. These results highlight the opportunity presented by these new pyrochlore compounds to study the effects of geometric frustration at relatively high temperatures, while also advancing the mPDF technique and providing a novel opportunity to investigate a genuinely short-range-ordered magnetic ground state directly in real space.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron spectroscopy by thermalization light yield measurement in a composite heterogeneous scintillator

An exothermic neutron capture reaction can be used to uniquely identify neutrons in particle detectors. With the use of a capture-gated coincidence technique, the sequence of scatter events that lead to neutron thermalization prior to the neutron capture can also be used to measure neutron energy. We report on the measurement of thermalization light yield via a time-of-flight technique in a polyvinyl toluene-based scintillator EJ-290 within a heterogeneous composite detector that also includes 6Li-doped glass scintillator. The thermalization light output exhibits a strong correlation with neutron energy because of the preference for near-complete energy deposition prior to the 6Li(n,t)4He neutron capture reaction. The nonproportionality of the light yield from nuclear recoils contributes to the observed broadening of the distribution of thermalization light output. The nonproportional dependence of the scintillation light output in the EJ-290 scintillator as a function of proton recoil energy has been characterized in the range of 0.3–14.1 MeV via the Birks parametrization through a combination of time-of-flight measurement and previously conducted measurements with Monoenergetic neutron sources.

6Li-doped scintillator↗

How correlations change the magnetic structure factor of the kagome Hubbard model

The kagome Hubbard model (KHM) is a paradigmatic example of a frustrated two-dimensional model. While its strongly correlated regime, described by a Heisenberg model, is of topical interest due to its enigmatic prospective spin-liquid ground state, the weakly and moderately correlated regimes remain largely unexplored. Motivated by the rapidly growing number of metallic kagome materials (e.g., Mn 3 Sn, Fe 3 Sn 2 , FeSn, Co 3 Sn 2 S 2 , Gd 3 Ru 4 Al 12 , and AV 3 Sb 5 with A = K, Rb, Cs), here we study the respective regimes of the KHM by means of three complementary numerical methods: the dynamical mean-field theory, the dynamical vertex approximation, and determinant quantum Monte Carlo. In contrast to the archetypal square lattice, we find no tendencies toward magnetic ordering, as magnetic correlations remain short-range. Nevertheless, the magnetic correlations undergo a remarkable crossover as the system approaches the metal-to-insulator transition. The Mott transition itself does not affect the magnetic correlations. Our equal-time and dynamical structure factors can be used as a reference for inelastic neutron scattering experiments on the growing family of metallic kagome materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interference analysis of the pion-production volume for hadron-hadron and nucleus-nucleus collisions at primary momenta in the range 3.8-5.2 GeV/c per nucleon

By the method of interference correlations, it was directly proven for the first time that the pion-production volume in neutron-proton (np) interactions at primary momenta in the range 3.8-5.2 GeV/c is not constant. It was shown that the interference patterns for np and MgMg interactions are identical. It was established that the rate of expansion of the pion-production volume does not depend on the type of interacting particles (from np and e{sup +}e{sup -} to PbPb collisions) or on their primary energy (from 3.4 to 200 GeV). It was found that the determination of dimensions is possible only for individual approximately stationary volume elements in their rest frame. A change in the kinematical properties of the subensemble under analysis leads to changes both in the size of the respective element and in its shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection Of Special Nuclear Materials Tagged Neutrons

In order to detect Special Nuclear Materials (SNM) in unattended luggage or cargo containers in the field of homeland security, fissions are induced by 14 MeV neutrons produced by an associated particle DT neutron generator, and prompt fission particles correlated with tagged neutron are detected by plastic scintillators. SMN produce high multiplicity events due to induced fissions, whereas nonnuclear materials produce low multiplicity events due to cross-talk, (n,2n) or (n,n'γ) reactions. The data acquisition electronics is made of compact FPGA boards. The coincidence window is triggered by the alpha particle detection, allowing to tag the emission date and direction of the 14 MeV interrogating neutron. The first part of the paper presents experiment vs. calculation comparisons to validate MCNP-PoliMi simulations and the post-processing tools developed with the data analysis framework ROOT. Measurements have been performed using different targets (iron, lead, graphite), first with small plastic scintillators (10 x 10 x 10 cm{sup 3}) and then with large detectors (10 x 10 x 100 cm{sup 3}) to demonstrate that nuclear materials can be differentiated from nonnuclear dense materials (iron, lead) in iron and wood matrixes. A special attention is paid on SNM detection in abandoned luggage. In the second part of the paper, the performances of a cargo container inspection system are studied by numerical simulation, following previous work reported in. Detectors dimensions and shielding against the neutron generator background are optimized for container inspection. Events not correlated to an alpha particle (uncorrelated background), counting statistics, time and energy resolutions of the data acquisition system are all taken into account in a realistic numerical model. The impact of the container matrix (iron, ceramic, wood) has been investigated by studying the system capability to detect a few kilograms of SNM in different positions in the cargo container, within 10 min acquisitions. (authors)

36 MATERIALS SCIENCE↗

Correlations of neutron multiplicity and γ -ray multiplicity with fragment mass and total kinetic energy in spontaneous fission of Cf 252

The dependence of correlations of neutron multiplicity ν and γ-ray multiplicity M γ in spontaneous fission of 252 Cf on fragment mass A* and total kinetic energy (TKE) have been investigated by employing the ratio of M γ /ν and the form of M γ (ν). We show for the first time that M γ and ν have a complex correlation for heavy fragment masses, while there is a positive dependence of Mγ for light fragment masses and for near-symmetric mass splits. The ratio M γ /ν exhibits strong shell effects for neutron magic number N=50 and near doubly magic number shell closure at Z=50 and N=82. The γ-ray multiplicity Mγ has a maximum for TKE=165-170 MeV. Above 170 MeV M γ (TKE) is approximately linear, while it deviates significantly from a linear dependence at lower TKE. The correlation between the average neutron and γ-ray multiplicities can be partly reproduced by model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studying Short-Range Correlations with the 12 C(e,e'pn) Reaction

We investigated electron-induced two-nucleon emission from carbon with the goal of being sensitive to and studying short-range correlations using the 12 C(e,e'pN) reaction in a triple-coincidence measurement. Two existing high-resolution spectrometers in Hall A at Jefferson Laboratory were used to detect coincident scattered electrons and struck nucleons. A large neutron detector designed and constructed specially for this experiment was used to detect the recoiling neutrons. We performed analysis of the 12 C(e,e'pn) reaction, and made direct observation of short-range correlated n-p pairs. From our analysis we conclude that there are 17.9±4.5 times more n-p short-range correlated pairs than p-p short-range correlated pairs.

43 PARTICLE ACCELERATORS↗

Measurements of n-p correlations in the reaction of relativistic neon with uranium

We report a preliminary measurement of coincident neutron-proton pairs emitted at 45 degrees in the interaction of 400, 530, and 650 MeV/A neon beams incident on uranium. Charged particles were identified by time of flight and momentum, as determined in a magnetic spectrometer. Neutral particles were detected using a thick plastic scintillator, and their time of flight was measured between an entrance scintillator, triggered by a charged particle, and the neutron detector. The scatter plots and contour plots of neutron momentum vs. proton momentum appear to show a slight correlation ridge above an uncorrelated background. The projections of this plane on the n-p momentum difference axis are essentially flat, showing a one standard deviation enhancement for each of the three beams energies. At each beam energy, the calculated momentum correlation function for the neutron-proton pairs is enhanced near zero neutron-proton momentum difference by approximately one standard deviation over the expected value for no correlation. This enhancement is expected to occur as a consequence of the attractive final state interaction between the neutron and proton (i.e., virtual or "singlet" deuterons). The implications of these measurements are discussed.

NASA Program Space Medicine↗

A Lumped Stochastic Model of Coupled Neutronic Assemblies

The objective of the present work is to apply the Harris ansatz to coupled assemblies in a lumped setting, i.e., ignoring the neutron phase dependence, which hitherto has not been considered. A Master equation for the single-time joint distribution of neutron number in each assembly, accounting for transfer of neutrons from one assembly to another via leakage transition probabilities and intercept or view factors is derived from which equations for the mean and variance in each assembly are developed. Because of the neutronic coupling, it is necessary to additionally compute the correlation function between pairs of assemblies which gives an expanded set of moment equations to solve. The reactivity of each assembly is allowed to vary with time, although a formal mechanism that is responsible for reactivity coupling between assemblies is not considered or proposed. Following Harris, it is then hypothesized that the number distribution in each assembly is a gamma distribution with assembly-specific mean and variance computed exactly from the moment equations. Illustrative numerical results are presented for the moments of a system of four coupled assemblies under various reactivity and neutronic coupling scenarios. The gamma distribution is then used to compute the probability that the neutron population exceeds a threshold value in any assembly. The report concludes with a discussion of recommended further work on this problem.