Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

New capability for neutron transmission measurements at LANSCE: The DICER instrument

A new capability for neutron transmission measurements has been developed at the Los Alamos Neutron Science Center (LANSCE). The DICER (Device for Indirect Capture Experiments on Radionuclides) instrument is designed to tightly constrain neutron-capture cross sections for short-lived radionuclides that are beyond the reach of direct techniques, via measurement and analysis of neutron transmission resonances on these same radionuclides. The innovative DICER apparatus enables simultaneous sample-in and sample-out measurements, thus minimizing the amount of sample material needed and reducing the measurements time by half. A description of the current status of the new transmission station, along with a performance overview and results from known reactions, will be presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the associated particle technique with high-resolution gamma-ray spectroscopy for in-field identification of chemical warfare agents and explosives

In this work, high-resolution prompt γ-ray neutron activation analysis (PGNAA) is performed using the associated particle (AP) technique with a deuterium-tritium neutron generator and high-purity germanium detector. Although the time resolution is inferior compared to similar systems employing fast scintillation γ-ray detectors, the strong background suppression combined with the high γ-ray energy resolution provides an important boost in sensitivity to certain key elements, especially relevant to field measurements of complex chemicals encased within thick layers of metal, such as in the case of recovered chemical warfare (CW) munitions. Results for various CW and explosive simulants contained within mock munitions are presented and compared with results obtained from traditional PGNAA measurements without the aid of the AP technique. Significant improvements in identification and discrimination between certain chemicals are achieved with the high energy resolution AP technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elemental profiling and genome-wide association studies reveal genomic variants modulating ionomic composition in Populus trichocarpa leaves

The ionome represents elemental composition in plant tissues and can be an indicator of nutrient status as well as overall plant performance. Thus, identifying genetic determinants governing elemental uptake and storage is an important goal for breeding and engineering biomass feedstocks with improved performance. In this study, we coupled high-throughput ionome characterization of leaf tissues with high-resolution genome-wide association studies (GWAS) to uncover genetic loci that modulate ionomic composition in leaves of poplar ( Populus trichocarpa ). Significant agreement was observed across the three ionomic profiling platforms tested: inductively coupled plasma-mass spectrometry (ICP-MS), neutron activation analysis (NAA) and laser-induced breakdown spectroscopy (LIBS). Relative quantification of 20 elements using ICP-MS across a population of 584 genotypes, revealed larger variation in micro-nutrients and trace elements content than for macro-nutrients across genotypes. The GWAS performed using a set of high-density (>8.2 million) single nucleotide polymorphisms, identified over 600 loci significantly associated with variations in these mineral elements, pointing to numerous uncharacterized candidate genes. A significant enrichment for genes related to ion homeostasis and transport was observed, including several members of the cation-proton antiporters (CPA) family and MATE efflux transporters, previously reported to be critical for plant growth and fitness in other species. Our results also included a polymorphic copy of the high-affinity molybdenum transporter MOT1 found directly associated to molybdenum content. For the first time in a perennial plant, our results provide evidence of genetic control of mineral content in a model tree species.

59 BASIC BIOLOGICAL SCIENCES↗

New machine protection system at the Spallation Neutron Source – design process and performance analysis

A New Machine Protection System (MPS) at the Spallation Neutron Source (SNS) was developed and implemented on µTCA-based hardware platforms. The system monitors more than 2500 field inputs and shuts off the beam within 10 µs if adverse events occur. We will present system level design process of various firmware and software components as well as the system integration into EPICS environment. The performance analysis of the MPS after two SNS run cycles will also be presented.

Bobrek, Miljko [ORNL] (ORCID:0000000332763451)↗

Real-time neutron multiplicity and source localization for criticality safety during fuel debris removal

Advancing neutron detection and analysis techniques for complex radiation environments is an ongoing focus in nuclear instrumentation and monitoring. This proposal presents research and development of a generalized real-time neutron monitoring and analysis system, applicable to any detector capable of producing time-tagged neutron count data. While the work is demonstrated using the Neutron Multiplication Analysis Detector (NoMAD), a modular 15-tube helium-3 (He-3) array, due to its availability, spatial resolution, and flexible deployment, the methods developed are extensible to other systems, including organic scintillators and fast digital detectors. This research investigates two complementary analytical techniques for real-time characterization of neutron emitting sources: neutron multiplicity estimation based on the Hage-Cifarelli formalism and spatial localization using supervised machine learning applied to spatial count rate patterns. These methods are designed to operate under dynamic, evolving conditions such as fuel debris retrieval or reactor startup, where neutron-emitting material geometries may be partially unknown or changing over time. By integrating statistical neutron emission data with spatial localization, this research aims to develop and evaluate methods for real time neutron monitoring, source characterization, and material verification. Key contributions include implementation of a low-latency data pipeline for continuous neutron multiplicity analysis, development and validation of machine learning models for spatial inference, and experimental evaluation of system performance under variable measurement conditions. The outcomes are intended to support applications in nuclear safeguards, verification, emergency response, and reactor startup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulated Energy Response in a Multiplicity Detector

Neutron multiplicity analysis is used for many applications, including nonproliferation and criticality safety. Multiplicity detectors have advantages over total neutron counting as they provide the ability to assess both multiplication and mass in fissionable material. In addition, multiplicity detectors can generate real-time information, e.g., dose estimation. The ability to evaluate the detector efficiency in each application is of primary importance in producing meaningful analyses. Multiplicity detectors usually house 3 He tubes within a polyethylene moderator. If the tubes are located behind different thickness of polyethylene, they will have different energy responses. This paper assesses 3 He tube efficiency as a function of neutron energy for a specific multiplicity detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise Measurement of the Neutron Magnetic Form Factor Using Super-BigBite Spectrometer at Jefferson Lab

The GMn experiment (E12-09-019) was conducted at Jefferson Laboratory from late 2021 into early 2022. The goal was to make high-precision measurement of the neutron’s magnetic form factor (GMn) at multiple kinematic points, including Q2 = 3.5, 4.5, 6.5, 8.5, 10, 12, 13.5, 16, and 18 (GeV/c)2. Limited data exist for GMn in the region up to about Q2 = 10 (GeV/c)2, with existing data having large systematic uncertainty. In this experiment, the ratio method was employed to reduce systematic uncertainty by measuring the ratio of neutron and proton yields. The experiment took place at Jefferson Laboratory in Hall A, where the BigBite spectrometer was used to detect the scattered electrons, while the HCal in the SuperBigbite spectrometer was used to detect both neutrons and protons. The protons were deflected slightly upwards with the use of a large-aperture dipole magnet named BigBen, allowing for enhanced particle identification. Extraction of GMn requires taking the ratio of proton and neutron yields. Analysis efforts are still currently underway to refine corrections to the data, including detector efficiencies, radiative corrections, neutron and proton mass identification, and charge exchange.

Lashley-Colthirst, Nathaniel↗

Central speed of sound, the trace anomaly, and observables of neutron stars from a perturbative analysis of scaled Tolman-Oppenheimer-Volkoff equations

The central speed of sound (SS) measures the stiffness of the equation of state (EOS) of superdense neutron star (NS) matter. Its variations with density and radial coordinate in NSs in conventional analyses often suffer from uncertainties of the specific nuclear EOS used. Using the central SS and NS mass/radius scaling obtained from solving perturbatively the scaled Tolman-Oppenheimer-Volkoff (TOV) equations, we study the variations of SS, trace anomaly and several closely related properties of NSs in an EOSmodel- independent manner. We find that the SS increases with the reduced central pressure Pˆ c ≡ P c =ε c (scaled by the central energy density εc), and the conformal bound for SS tends to break down for NSs with masses higher than about 1.9M ⊙ . The ratio P=ε is upper bounded as P=ε ≲ 0.374 around the centers of stable NSs. We demonstrate that it is an intrinsic property of strong field gravity and is more relevant than the perturbative QCD bound on it. While a sharp phase transition at high densities characterized by a sudden vanishing of SS in cores of massive NSs are basically excluded, the probability for a continuous crossover signaled by a peaked radial profile of SS is found to be enhanced as Pˆ c decreases, implying it likely happens near the centers of massive NSs. Moreover, a new and more stringent causality boundary as R max =km ≳ 4.73$M$$^{max}_{NS}$ =M ⊙ þ 1.14 for the NS mass-radius curve is found to be excellently consistent with observational data on NS masses and radii. Here, new constraints on the ultimate energy density and pressure allowed in NSs before collapsing into black holes are obtained and compared with earlier predictions in the literature

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive high explosive neutron inspection (PHENIX): a new method to confirm the presence or absence of high explosives for nuclear treaty verification

Advanced instruments and methods need to be developed now to create a technical basis to support the negotiation of future nuclear arms control treaties. One new capability that is anticipated is the ability to confirm either the declared presence or declared absence of high explosive (HE) material in the presence of special nuclear material (SNM). Towards this goal, Passive HE Neutron Inspection (PHENIX) has been developed and demonstrated as a method for confirming the presence or absence of HE in the presence of plutonium. The method exploits the inherent presence of neutrons associated with the decay of plutonium as an internal probe source for performing prompt gamma-ray neutron activation analysis (PGNAA), searching for the presence of HE as revealed by the emission of characteristic gamma rays following neutron absorption in hydrogen and nitrogen which are building blocks of present-day, military-grade HE. Tests using stoichiometrically-correct hemishells of mock HE with plutonium show that a system can be expected to positively confirm the presence or absence of these signatures, supporting determination of HE presence or absence with Pu, in a few hours. To protect other potentially sensitive gamma-ray signatures from a treaty accountable item, an analog information barrier has been conceptualized and tested which physically prevents the collection of gamma-ray spectral data outside of user selected energy windows strategically chosen to view only narrow spectral regions corresponding to the hydrogen (2223.2 keV) and nitrogen (9807.2 keV, 10,318.2 keV, and 10,829.2 keV) PGNAA signatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutronic engine

An internal combustion engine for neutron diffraction analysis is provided. The engine includes an elongated piston chamber formed from an aluminum alloy to ensure maximum neutron visibility into the combustion chamber. An elongated piston assembly reciprocates within the elongated piston chamber, the piston assembly including an upper piston joined to a lower piston. The upper piston and the lower piston are hollow, thereby reducing the reciprocating mass and increasing neutron access to the combustion chamber. The upper piston is lubricated with a neutron-transparent fluorocarbon lubricant such as perfluoropolyether (PFPE), while the lower piston and the crankcase are lubricated with hydrocarbon lubricant. The engine enables 3D and time-resolved measurements of strain, stress, and temperature, as well as phase transformation, texture, and microstructure.

Wissink, Martin L.↗

Application of Gaussian Bayes classifier to differentiate chlorine-based chemical agents

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector. One of the difficult technical challenges is to discriminate the chlorine-based chemical agents. Especially, CN, CNB, CNS and CG have similar chemical compositions to make it hard to discriminate them with a higher confidence. Current identification algorithms for PINS systems with 252-Cf sources have been improved and updated continuously as more field data became available, and new algorithms was studied to complement the current algorithms by adopting the Gaussian Bayes classifier. These new algorithms were intended to be applied to a subset of chlorine-based chemical agents, and their main goal is discriminate CN, CNB, CNS and CG with their ratios of the chlorine neutron inelastic 1763keV peak to the chlorine thermal neutron capture 1959keV peak, which is referred to as the “Cl i/c” or “clic” ratio in this study. The Cl i/c ratios were assumed to follow Gaussian distributions with the means and the standard deviations unique to their corresponding chemical agents. The prior probabilities of these four chemical agents were optimized with a collection of field data to achieve the best performance in terms of precision or positive predictive value (PPV). Finally, their posterior probabilities as functions of the Cl i/c ratio were implemented in the current version of PINS analysis software in order to be tested with more field data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Melt Wire Analyses for the Colorado School of Mines (CSM 16-10584) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors and melt wires irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the Colorado School of Mines (CSM 16-10584) experiment which was conducted in position B5 of the ATR. Neutron fluence monitor results were reported in February 2021 in report Neutron Dosimetry for the Colorado School of Mines (CM 16-10584) Irradiation in ATR. This report presents the analyses of the melt wire capsules that were included along with the neutron fluence monitors. Each capsule was identified by the ID stamp on the bottom, then opened to assess the condition of the Pb and Zn-Al wires as well as the Bi powder. Pictures are included to illustrate the results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

More Tools for Visualization and Analysis of Small-Angle Neutron Scattering Data: Descriptions and Examples

With the adoption of drtsans as the data reduction software for the GP-SANS, Bio-SANS and EQ-SANS instruments at ORNL, tools for data visualization and analysis that can be integrated into drtsans scripts are needed to further improve the user experience. New tools that do not need to be incorporated directly into data reduction scripts can also positively impact users during their experiments. In this report, a new set of tools is presented that complements the previous set released. The set includes tools for both fitting data and for visualizing data.

42 ENGINEERING↗

Interactive automated Bragg peak identification with 3D neutron scattering data

Neutron scattering experiments have undergone significant technological development through large area detectors with concurrent enhancements in neutron transport and electronic functionality. Data collected for neutron events include detector pixel location in 3D, time and associated metadata, such as, sample orientation, neutron wavelength, and environmental conditions. RadiaSoft and Oak Ridge National Laboratory personnel are considering single-crystal diffraction data from the TOPAZ instrument. We are leveraging a new method for rapid, interactive analysis of neutron data using NVIDIA’s IndeX 3D volumetric visualization framework. We have implemented machine learning techniques to automatically identify Bragg peaks and separate them from diffuse backgrounds and analyze the crystalline lattice parameters for further analysis. The implementation of automatic peak identification into IndeX allows scientists to visualize and analyze data in real-time. Our methods include a robust comparison with current analysis techniques which show improvement in a variety of aspects. These improvements will be incorporated into IndeX for visualization to allow scientists an interactive tool for crystal analysis.

Kilpatrick, Matthew↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dispersive optical model analysis of 208 Pb generating a neutron-skin prediction beyond the mean field

In this work, a nonlocal dispersive optical model analysis is carried out for neutrons and protons in 208 Pb. Elastic-scattering angular distributions, total and reaction cross sections, single-particle energies, neutron and proton numbers, the charge distribution, and the binding energy are fitted to extract the neutron and proton self-energies both above and below the Fermi energy. From the single-particle propagator derived from these self-energies, we determine the charge and matter distributions in 208 Pb. The predicted spectroscopic factors are consistent with results from the ($\textit{e,e}'\textit{p}$) reaction and inelastic-electron-scattering data to very high-spin states. Sensible results for the high-momentum content of neutrons and protons are obtained, with protons appearing more correlated, in agreement with experiment and ab initio calculations of asymmetric matter. A neutron skin of 0.25 ± 0.05 fm is deduced. An analysis of several nuclei leads to the conclusion that finite-size effects play a nonnegligible role in the formation of the neutron skin in finite nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗