Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Integrated simulations of premagnetized and self-magnetizing dynamic screw pinch-driven MagLIF

Magnetically driven implosions such as in magnetized liner inertial fusion (MagLIF) on the Z accelerator suffer from magneto-Rayleigh–Taylor instabilities (MRTI) that dynamically redistribute liner mass during implosion, limiting fusion fuel compression and confinement, which ultimately degrades performance. Driving the implosion with an initially helical drive field that dynamically shifts the direction of the magnetic field surrounding the liner (i.e., a dynamic screw pinch, DSP) is a method proposed to mitigate MRTI in-flight and improve target performance. In DSPs, the axial drive magnetic field component implodes the liner and diffuses through the shocked, melted liner material into the fuel throughout the implosion. Liners can be designed to enable enough axial magnetic flux to diffuse through the liner material to effectively magnetize the fuel region without the need of an initial axial magnetic field (i.e., from external field coils). We present results from three-dimensional radiation-magnetohydrodynamic simulations of MagLIF implosions employing drive magnetic fields composed of axial and azimuthal components (a helical drive field). These simulated DSP-driven MagLIF targets demonstrate improved fuel conditions and thermonuclear yield compared to a traditional MagLIF target implosion. Synthetic x-ray radiography of the imploding liner material and x-ray emission images of the fuel region at the time of peak neutron yield rate indicate superior implosion morphology for DSP-MagLIF implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging Bragg Edge Analysis TooLs for Engineering Structures (iBeatles)

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) provides pulsed neutrons with energies varying from epithermal to cold. In preparation for VENUS, the neutron imaging beamline to be located at beam port 10, we have performed a series of experiments focused on wavelength-dependent radiography and computed tomography for a broad range of applications, from materials science to biological tissues.One of the time-of-flight (TOF) techniques that is of interest to the scientific community is the 2-dimensional mapping of phases and average crystalline plane orientation in samples both ex-situ and during applied stresses such as tensile loading and heating. This technique is known as Bragg edgeimaging and relies on the identification of changes of transmission values, fitting of the edge to measure its displacement, and thus identify the shift in lattice parameter due to stresses. One of the challenges of TOF imaging measurements is the amount of data and the inability to observe Bragg edge shifts in real time during an experiment. Thus, we have been focusing on creating a Python-based interface that allows fast data processing and instantaneous mapping and fitting of the Bragg edges, and their evolution through time. Python libraries and Jupyter notebooks have been implemented to facilitate decision making during an experiment. The advantage of the notebooks is the possibility to guide an experiment as they can quickly process and display Bragg edge data. These notebooks can be used independently, or can be combined in a Python Graphical User Interface (GUI) tool called iBeatles. This interface permits visualization and fitting of the Bragg edges, and ultimately back-projects the fitting results onto the radiographs to display a strain map. Assuming data collection has sufficient statistics, the strain mapping analysis can be performed on a pixel-by-pixel basis. This development is a step forward toward a better user experience at the future VENUS beamline in terms of live feedback and productivity. Analysis that used to take days of switching between different applications can now be done in minutes within the

Bilheux, JeanChristophe [Oak Ridge National Labora↗

Multi-Probe FY25 Omega EP Shot Request [Slides]

The goal of the Multi-Probe experimental campaign is to assess the feasibility of using multiple probe types (x ray, proton, neutron, and electron) in future LANL radiographic facilities. X-ray and proton platforms have been demonstrated. The first attempts at simultaneous radiography were hampered by cross talk, which was the subject of FY23 & FY24 experiments. The major goal for FY25 is to demonstrate simultaneous radiography of both static and dynamic objects.

36 MATERIALS SCIENCE↗

Multi-Probe 23A Pre-Shot report

The Multi-Probe Radiography campaign will field a full day of experiments at the Omega EP laser facility. The experiments will consist of shots that alternate between Omega EP’s two short-pulse laser beams to generate proton and deuteron beams from a variety of film and foam targets. The proton beam is intended to be used as a radiographic source, while the deuteron beam will be used as the pitcher in a pitcher-catcher neutron-generation concept. For the proton beam, our goal is to characterize the angular distribution and energy spectra of unwanted x-rays that are generated during proton acceleration and were found to be problematic for simultaneous radiography in MP-22A. As part of this primary goal, we will test whether an x-ray shield, XBLK, can be used to prevent these x-rays from impacting other x-ray diagnostics. For the deuteron beam, our primary goal is to characterize the energy spectra and beam profile of deuterons accelerated from CD foils and foams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

First graded metal pushered single shell capsule implosions on the National Ignition Facility

Graded metal pushered single shell (PSS) capsules are predicted to be a viable alternative to low-Z capsule indirect drive inertial confinement fusion (ICF) implosions for achieving high fusion yields [MacLaren et al., Phys. Plasmas 28, 122710 (2021)]. The first experiments with Be/Cr-graded metal PSS capsules indicate that the implementation of the principle design feature, the graded density inner metal layer, has succeeded in producing a stable implosion with performance in agreement with predictions. With 50% Cr concentration in the pusher, PSS capsules have greater than ~2× higher shell densities during stagnation for enhanced core confinement and radiation trapping at ~35% lower shell implosion velocities than low-Z capsules. High-energy >30 keV inflight shell radiography recorded 215 km/s implosion velocities and show that implosion Legendre mode P 2 asymmetry can be tuned via inner-to-outer beam wavelength separation, similar to other implosions. Shell radiographs and neutron core images show similar P 2 asymmetry, suggesting no symmetry swings between peak implosion velocity and stagnation times. Despite the modest implosion velocities, gas-filled deuterium–tritium capsule implosions generate 10 15 neutron yields at relatively modest core ion temperatures of 2.75 keV, indicating that in spite of the high-density inner layer, the implosions have been stabilized by the design density gradient. When compared with hydrodynamic simulations, the measured yield-over-simulated is 35% due to fuel–pusher mix and other perturbations such as the capsule fill tube. Finally, simple analytical scalings of hot spot pressure and neutron yield show that PSS implosions reach similar performance at lower implosion velocities and higher shell densities to low-Z ICF capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Overview of the LANL Multi-Probe Radiography Project [Slides]

Future radiographic facilities for the U.S. defense program will be required to provide more information as simulation codes improve in both physics’ fidelity and resolution. A possible approach is to use more types of probe beams in addition to, or instead of X-rays, generated by 20-MeV electron accelerators from a small number of directions. High power short-pulse laser systems can generate beams of protons, neutrons and electrons, as well as X-rays. The cost of these systems is falling rapidly. So, it can be imagined that deploying multiple short-pulse lasers along with other, more traditional probes, will become feasible. In this project, we are following three paths to determine if such an approach will succeed for cm-scale objects. The first is an experimental one to determine if the presence of multiple short-pulse probes cause interference with each other, especially while radiographing dynamic objects. The second leg of this project is to determine if having multiple types of probes really does give more information on composition. Finally, an overall assessment of the viability of this approach will be made. Examples from recent experiments at the Omega EP laser will be presented. The initial approach to evaluating radiographs with multiple probes using the Bayesian Inference Engine (BIE) also will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Causes of fuel–ablator mix inferred from modeling of monochromatic time-gated radiography of OMEGA cryogenic implosions

Here, we present evidence, in the context of OMEGA cryogenic target implosions, that laser imprint, known to be capable of degrading laser-direct-drive target performance, plays a major role in generating fuel–ablator mix. OMEGA cryogenic target implosions show a performance boundary correlated with acceleration-phase shell stability; for sufficiently low adiabats (where the adiabat is the ratio of the pressure to the Fermi pressure) and high in-flight aspect ratios (IFAR's), the neutron-weighted shell areal density and neutron yield relative to the clean simulated values sharply decline. Direct evidence of Rayleigh–Taylor fuel–ablator mixing was previously obtained using a Si Heα backlighter driven by an ~20-ps short pulse generated by OMEGA EP. The shadow cast by the shell shortly prior to stagnation, as diagnosed using backlit radiographs, shows a softening near the limb, which is evidence of an ablator–fuel mix region for a low-adiabat implosion (α ~ 1.9, IFAR = 14) but not for a moderate adiabat implosion (α ~ 2.5, IFAR = 10). We find good agreement between experimental and synthetic radiographs in simulations that model laser imprint and account for uncertainty in the initial ablator thickness. Furthermore, we further explore the role of other mechanisms such as classical instability growth at the fuel–ablator interface, species concentration diffusion, and long-wavelength drive and target asymmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Probe 24A: Post shot Data and Analysis

The Multi-Probe 24A experiments took place on the Omega EP laser in November 2023. The experiments consisted of shots alternating between Omega EP’s two short-pulse laser beams to generate proton and deuteron ion beams from a range of film thicknesses, and x-ray sources from the established CPC+Ta wire targets. The backlighter was used for ion acceleration in the pitcher series, in which deuteron and proton beams characterized as a function of CD film thickness to develop a pitcher for a pitcher-catcher neutron radiographic source, while also characterizing electrons and x-rays emitted perpendicular to the target (i.e. Crosstalk for sidelighter-driven x-ray beams). The sidelighter was used for electron acceleration in the x-ray series, in which the electron acceleration and subsequent x-rays was characterized from the CPC+Ta wire targets and radiography was conducted with and without electro-magnetic electron defection. For the pitcher series, we found that at 500 J and 0.7 ps the 700-800 nm CD films yielded the greatest number and highest energy for both protons and deuterons. For the x-ray series, results demonstrated: a significant number of <100 keV x-rays are produced within the glue that fills the CPC cone, on-axis electron signal from the x-ray targets produce electrons resolvable up to ~10 MeV, and electron deflection (using MIFEDS) has a notable effect radiograph on noise reduction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Physical Sciences Vistas: Issue 4 2021

In this issue of Physical Sciences Vistas we highlight examples of “excellence in nuclear security.” In this issue, highlights of our outstanding work supporting the Laboratory’s nuclear security enterprise include the following: The complete refurbishment of Sigma’s surface finishing lab. Pride in the lab’s revitalized condition on the part of the operations and R&D staff responsible for this complex operation is well justified. Development of advanced materials and processes enabling next-generation weapons designs, much of which has been facilitated by projects supported by the Laboratory Directed Research and Development Program. The use of proton radiography in illuminating elements important to validating high explosive burn models. The experimental series was a collaboration between Los Alamos researchers and staff at Lawrence Livermore and Sandia national laboratories and the United Kingdom’s Atomic Weapons Establishment. Deployment of a sophisticated remote handling unit to safely transfer highly radioactive materials required to support mission-critical projects. The skillful swap of an electrical transformer at the Los Alamos Neutron Science Center (LANSCE). The deliberate operation restored power to the accelerator in less than estimated time. A look at George Goff ’s role in translating fundamental science into applied solutions essential to the Lab’s nuclear security mission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sparse-Data Deep Learning Strategies for Radiographic Non-Destructive Testing

Radiography is an imaging technique used in a variety of applications, such as medical diagnosis, airport security, and nondestructive testing. We present a deep learning system for extracting information from radiographic images. We perform various prediction tasks using our system, including material classification and regression on the dimensions of a given object that is being radiographed. Our system is designed to address the sparse-data issue for radiographic nondestructive testing applications. It uses a radiographic simulation tool for synthetic data augmentation, and it uses transfer learning with a pre-trained convolutional neural network model. Using this system, our preliminary results indicate that the object geometry regression task saw an improvement of 70% in the R-squared value when using a multi-regime model. In addition, we increase the performance of the object material classification tasks by utilizing data from different imaging systems. In particular, using neutron imaging improved the material classification accuracy by 20% when compared to x-ray imaging.

convolutional neural networks↗

Report for LANSCE Futures Spring 2021 Workshop Series

The Los Alamos Neutron Science Center (LANSCE) has a long and successful history of delivering high-impact science for NNSA missions. The breadth of science LANSCE delivers is enabled by a unique combination of beam power, flexibility, and authorization basis. Though LANSCE is entering its 50th year of operations, current plans for the stockpile require LANSCE capabilities beyond 2050. These requirements demand a technical conversation about the accelerator and the long-term scientific vision for the facility, so we convened a set of workshops to initiate that conversation. The LANSCE Futures workshops spanned three capability areas of LANSCE: dynamic radiography, scattering science, and nuclear science. Participants included the relevant experts from the programs sponsoring LANSCE, the experimentalists utilizing the end-stations, and accelerator systems experts. A final workshop combined the three focus areas to begin the conversation about capabilities that could meet future mission needs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Report DE-SC0020773

The DOE/NNSA sought development of innovative portable neutron/x-ray cameras for imaging and, when coupled with a portable source, also for radiography. This project focused on developing such a device that promises to have excellent resolution, while also providing neutron/gamma separation. We developed an Application Specific Integrated Circuit (ASIC) to be employed in conjunction with existing sensor technologies and modern assembly techniques. The concepts developed were a combination of new novel techniques and an innovative implementation of existing methods boosted by technological advances in ASIC performance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Configuration and impurity quantification of AmLi sources using radiography and gamma spectroscopy

This paper presents the non-destructive assay of two AmLi sources used for detector characterization and active interrogation at PNNL, identified as MRC-101 and MRC-103. First, a detailed description of the internal configuration of 2724-BT encapsulated MRC sources is established. X-ray radiographs of the AmLi sources are reported for the first time to verify the dimensions and orientation of the encapsulation. Notably, a density variation was observed as a contrast change across the height of the source cavities. Contrary to commonly made assumptions in literature, it is indirectly observed that the AmLi source/target material only occupies a portion of the source cavity. The intensity of the prompt gamma-rays resulting from the inelastic scatter of alpha particles on 7Li was used to calculate the mass ratios of LiH:AmO2. The gamma-ray spectra revealed the presence of numerous impurities in both source and target material (243Am, 237Np, 154Eu, 23Na, and 9Be). Neutron-gamma production ratios were applied to the intensity of the Doppler-broadened peaks from alpha-induced reactions with 7Li, 9Be, and 23Na to calculate neutron rates for both sources. A neutron/alpha production yield (derived in this work) was then related to the atomic concentration of these isotopes to find the approximate masses within each source. Ultimately, the AmLi source density was estimated with prompt gamma analysis based on partial source volumes as 0.45±0.08 g/cm^3.

DTRA, AmLi, neutron↗

Assessing the performance of MagLIF with 3D MHD simulations

The Magnetized Liner Inertial Fusion (MagLIF) experimental platform at Sandia National Laboratories has realized a number of recent improvements in electrical current and laser preheat coupling but fusion yields are below expectations, based on modeling with clean (that is, simulations with no interfacial instabilities and no mix) two-dimensional (2D) magneto-hydrodynamics (MHD) simulations, by a factor of 5 or more. However, magnetized liner implosions are known to produce helical magneto-Rayleigh–Taylor (MRT) modes and complex stagnation structures that cannot be directly modeled in 2D. This paper presents the results of 3D HYDRA MHD simulations, including helical MRT, showing that degradation from these instabilities can readily reproduce experimental yields, but it is difficult to simultaneously match the yield along with inferred fuel temperature, pressure, and burn history (assessed with x-rays), which are larger in the experiments considered here. Additional analysis methods and future experiments are proposed to help address the discrepancies. The 3D simulations also show, without substantive improvements to stability, changing the applied Bz or preheat is unlikely to increase performance of MagLIF to the same degree as clean 2D simulations. Finally, the first 3D HYDRA simulations with the Hall term show the ab initio production of helical MRT and produce a clear change in stagnation morphology compared to pre-seeded simulations without Hall. In spite of the differences, the simulations still produce comparable fusion performance but with longer, lower power, neutron yield history.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗