Search NASASearch

SEARCH · Search NASA

Results for “Nuclear Engine for Rocket Vehicle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,554 records · Page 11

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

Amphiphilic nanopores that condense undersaturated water vapor and exude water droplets

Condensation of water vapor in confined geometries, known as capillary condensation, is a fundamental phenomenon with far-reaching implications. While hydrophilic pores enable liquid formation from undersaturated vapor without energy input, the condensate typically remains confined, limiting practical utility. Here, we explore the use of amphiphilic nanoporous polymer-infiltrated nanoparticle films that condense and release liquid water under isothermal and undersaturated conditions. By tuning the polymer fraction and nanoparticle size, we optimize condensation and droplet formation. As vapor pressure increases, voids fill with condensate, which subsequently exudes onto the surface as microscopic droplets. This behavior, enabled by a balance of polymer hydrophobicity and capillarity, reveals how amphiphilic nanostructures can drive accessible water collection. Our findings provide design insights for materials supporting energy-efficient water harvesting and heat management without external input.

Science & Technology - Other Topics

Anomalous Spin‐Optical Helical Effect in Ti‐Based Kagome Metal

The kagome lattice stands as a rich platform for hosting a wide array of correlated quantum phenomena, ranging from charge density waves and superconductivity to electron nematicity and loop current states. Direct detection of loop currents in kagome systems has remained a formidable challenge due to their intricate spatial arrangements and the weak magnetic field signatures they produce, and this has made their identification experimentally subtle. This has left their existence and underlying mechanisms a topic of intense debate. In this work, we uncover signatures compatible with loop currents: spin handedness-selective signals that surpass conventional dichroic, spin, and spin-dichroic responses. We observe this phenomenon in the kagome metal CsTi 3 ⁢Bi 5 and we call it the anomalous spin-optical helical effect. This effect arises from the coupling of light's helicity with spin-orbital electron correlations, thereby providing an indirect yet sensitive approach to probe loop-current–related electronic correlations in quantum materials. Our discovery not only enriches the debate surrounding loop currents but also offers new experimental strategies to exploit the electronic phases of quantum materials via light–matter interaction.

anomalous spin-optical helical effect

Fusion Safety Program Peer Review (August 31 and September 1, 1999) [Slides]

The Fusion Safety Program Peer Review conference, held on August 31 and September 1, 1999, focuses on advancing the understanding and management of radioactive and hazardous materials within deuterium-tritium (D-T) fusion machines. The conference aims to investigate the behavior of significant sources of radioactive materials, such as activation products, dust, tritium, and beryllium. Additionally, it seeks to comprehend how various energy sources in fusion facilities—such as magnets, plasma, decay heat, and chemical reactions—can mobilize these materials. A key objective of the conference is to develop integrated, state-of-the-art analytic tools to demonstrate the safety and environmental potential of fusion technology. Furthermore, the conference assesses and evaluates safety and environmental issues associated with emerging fusion concepts, including those in the ARIES, ALPS, APEX, and IFE projects. This comprehensive approach aims to ensure the safe and sustainable advancement of fusion energy.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY