Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPERATION AND MAINTENANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

2022 Through April 2023 Corrective Measures Implementation and Interim Measures Annual Status Report: Summary of Biosparge System Operation and Maintenance, Interim Measures and Monitoring Mobile Launch Platform Rehabilitation Sites / Vehicle Assembly Building Area (Swmu 056) Kennedy Space Center, Florida

This report presents a summary of the Corrective Measures Implementation (CMI) and Interim Measure (IM) implementation activities that occurred from January 2022 through April 2023 at the Mobile Launch Platform Rehabilitation Sites (MLP)/Vehicle Assembly Building (VAB) Area, Solid Waste Management Unit 056 (SWMU 056), located at the John F. Kennedy Space Center, Florida. The following summaries briefly describe areas within SWMU 056 identified by historical site investigation activities where groundwater monitoring and remedial actions have been implemented to date.

VOCs↗

Normal operation and maintenance safety lessons from the ITER US PbLi test blanket module program for a US FNSF and DEMO

A leading power reactor breeding blanket candidate for a fusion demonstration power plant (DEMO) being pursued by the US Fusion Community is the Dual Coolant Lead Lithium (DCLL) concept. The safety hazards associated with the DCLL concept as a reactor blanket have been examined in several US design studies. These studies identify the largest radiological hazards as those associated with the dust generation by plasma erosion of plasma blanket module first walls, oxidation of blanket structures at high temperature in air or steam, inventories of tritium bred in or permeating through the ferritic steel structures of the blanket module and blanket support systems, and the 210Po and 203Hg produced in the PbLi breeder/coolant. What these studies lack is the scrutiny associated with a licensing review of the DCLL concept. An insight into this process was gained during the US participation in the International Thermonuclear Experimental Reactor (ITER) Test Blanket Module (TBM) Program. In this paper we discuss the lessons learned during this activity and make safety proposals for the design of a Fusion Nuclear Science Facility (FNSF) or a DEMO that employs a lead lithium breeding blanket.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

General description of HTR-PM emergency power system - 18415

The paper will describe the design concept of the emergency power system utilized in the high temperature gas cooled reactor project (HTR-PM) which is currently under construction in Shandong, China. As a class 1E system which is related to the safety feature of the reactor, emergency power system is responsible for providing multiple reliable power sources for nuclear safety class loads. Therefore, the structure, power source deployment, operation, maintenance and alignment of the system should meet several standards and regulations. The paper will give a detailed description about the designing process of the system which include structure design, determination of primary device parameters, and some calculation results of device capacity such as emergency diesel engine, UPS et al. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization

Operation and maintenance costs for nuclear power plants are very large. Reactors are starting to shut down even after their operating licenses have been extended, because they are not price competitive compared to other energy sources. The nuclear industry is witnessing early closure of nuclear power plants due to economic reasons despite excellent safety records. Therefore, it is imperative to reduce costs to prevent these early closures. This paper showcases recent research into advanced fault diagnostics techniques and preventative maintenance optimization to reduce these maintenance costs. This report focuses on the condensate and feedwater system for both pressurized and boiling water reactor systems. The computerized maintenance management system, which contains the plant’s digital record of all the corrective- and preventative-maintenance work orders, was used as a ground truth to locate potential faults and label the process data as healthy or faulty. Various feature extraction techniques were utilized to further differentiate the faults from the healthy data. Support vectors machines were used to categorize other test sets of process data as healthy or faulty through a cross validation procedure. Similar faults were not found within this system leading to preventative maintenance optimization. Unnecessary amounts of preventative maintenance lead to inflated maintenance costs. This paper summarizes the steps for preventative maintenance optimization from component health determination to recommendation for action. This optimization was completed for condensate pumps, condensate booster pumps, and the respective motors that drive them.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Demonstration of the Human and Technology Integration Guidance for the Design of Plant-Specific Advanced Automation and Data Visualization Techniques

Nuclear power continues to be a safe, reliable, and carbon-free electricity generating source for the United States, though the cost of operating and maintaining the current United States nuclear power plant fleet has become uncompetitive with other sources. This gap is attributed to the advent of new digital instrumentation and control technologies that other electricity generating industries are currently leveraging to streamline work and greatly reduce operating, maintenance, and support costs. Digital instrumentation and control systems and control room modernization offers significant opportunities to reduce operating and maintenance costs to ensure the continued operation of the existing United States light-water reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cryogenic Insulation Systems

The results of a comparative study of cryogenic insulation systems performed are presented. The key aspects of thermal insulation relative to cryogenic system design, testing, manufacturing, and maintenance are discussed. An overview of insulation development from an energy conservation perspective is given. Conventional insulation materials for cryogenic applications provide three levels of thermal conductivity. Actual thermal performance of standard multilayer insulation (MLI) is several times less than laboratory performance and often 10 times worse than ideal performance. The cost-effectiveness of the insulation system depends on thermal performance; flexibility and durability; ease of use in handling, installation, and maintenance; and overall cost including operations, maintenance, and life cycle. Results of comprehensive testing of both conventional and novel materials such as aerogel composites using cryostat boil-off methods are given. The development of efficient, robust cryogenic insulation systems that operate at a soft vacuum level is the primary focus of this paper.

Augustynowicz, S. D.↗

Abstract for CRADA between NETL and Electric Power Research Institute (EPRI) (AGMT-1113)

The National Energy Technology Laboratory (NETL) and EPRI (Participant) will collaborate in the investigation of flashovers in electric power distribution maintenance operations. Live line and barehand maintenance techniques are used on overhead transmission lines around the world. While flashovers during this type of work are rare, several unexplained flashovers have occurred in North America. In each case, available evidence suggests these occurred at steady state (60 Hz) system voltage and at voltage stress levels well below that which is known to cause flashover. Understanding the cause of these flashovers is essential so they can be avoided in the future and enhance line worker safety. Some utilities are considering adding sheds to their live line tools (e.g. hot sticks) as a possible mitigation measure. The effect of adding sheds to the hot sticks was modelled and published by Chalmers University. A strong case can be made for sheds if the model can be validated through laboratory testing. This research is envisioned to be a multiple-year project. The work proposed under this agreement represents the initial research steps which will involve reproducing, verifying, and extending the modeling research previously published by Chalmers University.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technology for Water Treatment

There are approximately 500,000 water cooling towers in the United States, all of which must be kept clear of "scale" and corrosion and free of pollutants and bacteria. Electron Pure, Ltd. manufactures a hydro cooling tower conditioner as well as an automatic pool sanitizer. The pool sanitizer consists of two copper/silver electrodes placed in a chamber mounted in the pool's recirculation system. The tower conditioner combines the ionization system with a water conditioner, pump, centrifugal solids separator and timer. The system saves water, eliminates algae and operates maintenance and chemical free. The company has over 100 distributors in the U.S. as well as others in 20 foreign countries. The buildup of scale and corrosion is the most costly maintenance problem in cooling tower operation. Jet Propulsion Laboratory successfully developed a non-chemical system that not only curbed scale and corrosion, but also offered advantages in water conservation, cost savings and the elimination of toxic chemical discharge. In the system, ozone is produced by an on-site generator and introduced to the cooling tower water. Organic impurities are oxidized, and the dissolved ozone removes bacteria and scale. National Water Management, a NASA licensee, has installed its ozone advantage systems at some 200 cooling towers. Customers have saved money and eliminated chemical storage and discharge.

Source record↗